Search PubMed⌕ Search

Biomedical subjects

K Scheffler

Publications and source records attributed to K Scheffler.

41 records · Page 3Linked to original sources

Hydro-MRI for the visualization of gastric wall motility using RARE magnetic resonance imaging sequences.

BACKGROUND: Although different imaging techniques such as conventional X-ray, ultrasonography, and hydro-computed tomography are available for the imaging of the stomach, none can depict this organ in full size without radiation. Therefore, the study of the entire gastric wall motility of the stomach is difficult and in principle only performable with rapid magnetic resonance imaging (MRI) techniques. T1-weighted imaging sequences have been used for the dynamic study of gastric wall motility. This technique was combined with the oral intake of para- or superparamagnetic contrast agents to achieve sufficient intraluminal contrast. The technique described in the present study is based on a different contrast mechanism. METHODS: The stomach was filled with 500 mL of 10% of aqueous dextrose solution, and a strongly T2-weighted fast rapid acquisition with relaxation enhancement (RARE) type imaging sequence was used for data acquisition. No other contrast agents were applied. An ultrafast RARE imaging sequence with an asymmetric phase-encoding scheme was developed to achieve a high temporal and spatial resolution. The scanning time per image was approximately 1 s. RESULTS: The stomach was imaged in full size. The concentric constrictor rings moved from the proximal part of the body toward the antrum. The mean duration for one contraction cycle was approximately 17.9 +/- 2.5 s, the mean contractile frequency was 3.4 +/- 0.5 s, and the mean spreading velocity was 65.5 +/- 3.6 cm/min. CONCLUSIONS: The purpose of this study was to demonstrate a new technical approach for a noninvasive dynamic study of gastric motor function with hydro-MRI. This robust method may have clinical application, e.g., in the diagnosis of gastroparesis, and may be extended to the rest of the gastrointestinal tract.

Administration, Oral↗

Tomographic imaging with nonuniform angular sampling.

A new class of polar sampling patterns for projection imaging is described. In contrast to conventional techniques, a nonuniform variation of the angular increments between consecutive projections is introduced. The proposed method allows adaptation of the polar sampling pattern to different shapes of the object. Numerical simulations and MR experiments verify that angular sampling density can be varied according to the radial extension of the object, resulting in a reduction of the total number of required projections (and X-ray exposure) compared with conventional circular field-of-view imaging.

Technology, Radiologic↗

Contrast-enhanced subtraction MR angiography in occlusive disease of the pelvic and lower limb arteries: results of a prospective intraindividual comparative study with digital subtraction angiography in 76 patients.

PURPOSE: The purpose of this work was to evaluate the feasibility and clinical use of MR angiography (MRA) for examining the pelvic and lower limb arteries in patients with arterial occlusive disease. METHOD: Seventy-six patients with clinical signs of peripheral arterial occlusive disease were included in the study. MRA was performed using a fast contrast-enhanced high-resolution 3D technique that covered the area from the distal abdominal aorta to the distal lower limbs in two examination steps. RESULTS: In all patients, diagnostic images comparable with those of conventional intraarterial digital subtraction angiography (DSA) could be obtained. No false-negative findings were seen in the iliac, femoral, or popliteal arteries. Ten to 16% of the mild stenoses and 6-14% of the severe stenoses, mainly in the crural vessels, were overgraded compared with intraarterial DSA. Particularly in patients with proximal severe obstructions or occlusions, the crural segments could be depicted more clearly due to decreased arterial runoff in conventional angiography. CONCLUSION: The consistency of the excellent depiction of the vascular territories of the distal aorta and the pelvic and lower limb arteries in a standardized setting suggests great potential for the use of MRA in the primary diagnosis of peripheral arterial occlusive disease.

Aged↗

Optimization of contrast-enhanced MR angiography of the hands with a timing bolus and elliptically reordered 3D pulse sequence.

Our objective was to optimize bolus administration and sequence setting in gadolinium-enhanced magnetic resonance (MR) angiography of the hands. Elliptically reordered three-dimensional (3D) spoiled gradient-echo sequence with non-slab-selective radio frequency excitation was optimized according to the measurements of arterial and venous time-signal curves in 21 patients. Great variations in bolus arrival time and arterio-venous transit time could be observed. In most patients high-quality arterial depiction could be obtained with minor venous contamination. Contrast-to-noise, spatial resolution, and selective arterial filling is still a challenge for 3D MR angiography of the hand but can be optimized using Gadolinium-BOPTA and a dedicated pulse sequence setting with exact bolus timing.

Adolescent↗

Flavin enzymes, mitochondrial radicals and reduced glutathione in daily rhythmic dependency.

The diurnal rhythms of the microsomal flavoprotein NADPH-cytochrome c reductase activity, of diaphorase and of succinic dehydrogenase are presented. Minimum levels are ascertained at 09(00), maximum levels at 21(00). The concentration of mitochondrial radicals as a function of the time of day is also demonstrated. Here too the minimum is at 09(00) and the maximum between 15(00) and 21(00). On the other hand, GSH levels are found to be high between 09(00) and 12(00) and low in the evening. Thus a causative relationship between the concentration of cellular radicals, which originate in flavin enzymes, and the concentration of the tripeptide glutathione is assumed.

Animals↗