Search PubMed⌕ Search

Biomedical subjects

Johan Roeraade

Publications and source records attributed to Johan Roeraade.

28 records · Page 2Linked to original sources

Improved method for peak picking in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry.

A method for peak picking for matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) is described. The method is based on the assumption that two sets of ions are formed during the ionization stage, which have Gaussian distributions but different velocity profiles. This gives rise to a certain degree of peak skewness. Our algorithm deconvolutes the peak and utilizes the fast velocity, bulk ion distribution for peak picking. Evaluation of the performance of the new method was conducted using peptide peaks from a bovine serum albumin (BSA) digest, and compared with the commercial peak-picking algorithms Centroid and SNAP. When using the new two-Gaussian algorithm, for strong signals the mass accuracy was equal to or marginally better than the results obtained from the commercial algorithms. However, for weak, distorted peaks, considerable improvement in both mass accuracy and precision was obtained. This improvement should be particularly useful in proteomics, where a lack of signal strength is often encountered when dealing with weakly expressed proteins. Finally, since the new peak-picking method uses information from the entire signal, no adjustments of parameters related to peak height have to be made, which simplifies its practical use.

Animals↗

Matrix-assisted and polymer-assisted laser desorption/ionization time-of-flight mass spectrometric analysis of low molecular weight polystyrenes and polyethylene glycols.

Recently, matrices based on oligomers of dioxin and thiophene (polymer-assisted laser desorption/ionization (PALDI)) have been described for mass spectrometric (MS) analysis of low molecular weight compounds (Woldegiorgis A, von Kieseritzky F, Dahlstedt E, Hellberg J, Brinck T, Roeraade J. Rapid Commun. Mass Spectrom. 2004; 18: 841-852). In this paper, we report the use of PALDI matrices for low molecular weight polymers. An evaluation with polystyrene and polyethylene glycol showed that no charge transfer ionization occurs. Ionization is mediated through metal ion adduction. Comparison of matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) data for two very low molecular weight polymers with data obtained from size-exclusion chromatography (SEC) revealed a systematic difference regarding mean molecular weight and dispersity. Further, the mass spectra obtained with PALDI matrices had a higher signal-to-noise ratio than the spectra obtained with conventional matrices. For polymers with higher molecular weights (>1500 Da), the conventional matrices gave better performance. For evaluation of the MALDI spectra, three non-linear mathematical models were evaluated to model the cumulative distributions of the different oligomers and their maximal values of Mw, Mn and PDI. Models based on sigmoidal or Boltzmann equations proved to be most suitable. Objective modeling tools are necessary to compare different sample and instrumental conditions during method optimization of MALDI analysis of polymers, since the bias between MALDI and SEC data can be misleading.

Biopolymers↗

Evaluation of generic chiral liquid chromatography screens for pharmaceutical analysis.

Two different automated generic liquid chromatography screens for the separation of chiral compounds of pharmaceutical interest have been evaluated. The test set comprised 53 chemically diverse chiral compounds involving 55 enantiomeric pairs from the pharmaceutical industry (i.e. starting materials, synthetic intermediates and drug substances). The first screen utilised four polysaccharide-based columns with five mobile phases and showed enantioselectivity for 87% of the test compounds. The second screen employed three macrocyclic glycopeptide columns with two mobile phases and showed enantioselectivity for 65% of the test compounds. Merging of the two screening procedures resulted in an enantioselectivity for 96% of the chiral compounds. It is anticipated that the systematic use of the automated chiral HPLC screens described in this report will substantially reduce the necessary time for method development of pharmaceutically related chiral analytical methods.

Chromatography, High Pressure Liquid↗

Quantitative accuracy in the gas chromatographic analysis of solvent mixtures.

Quantitative accuracy is of great importance in the analysis of bulk mixtures of solvents, particularly when the analysis is related to quality control of very large product volumes like in solvent recovery plants. Serious errors can be made if the effects of density differences between the pure solvents and volume contractions are not properly addressed. In earlier work, the use of an iterative process for correcting such errors has been suggested. However, in the case of volume contractions and mixtures of several solvents, this procedure is difficult to apply. In the present paper, we describe a simple procedure where calibration curves based on mass concentration are utilized. The densities of calibration mixtures of known compositions are determined with a density meter, in order to provide for correction factors caused by volume contractions. Model experiments with mixtures of water, ethanol, acetone and methanol showed a significant improvement in quantitative accuracy. when the suggested calibration strategy was applied.

Chromatography, Gas↗

Continuous segmented-flow polymerase chain reaction for high-throughput miniaturized DNA amplification.

A continuous segmented-flow method for sequential DNA amplification is described in order to provide a basis for high-throughput genetic analysis. The approach allows an immediate distinction between amplified and nonamplified products. A mixture of sample and reagents are loaded in the form of small segments one after another in a 15-m-long narrow-bore Teflon tube, coiled such as to be repeatedly exposed to three different temperature zones. After having passed the heated zones, the samples are mixed with an intercalating dye by flow injection and sequentially detected on-line by laser-induced fluorescence. The aqueous samples travel as separate segments in a continuous flow of an immiscible, organic liquid. Perfluorodecalin was shown to be particularly suitable due to its hydrophobicity and inert properties. To reduce carryover between samples, an intermediate water plug between two consecutive samples was required. Selected regions from human genomic DNA were successfully amplified in 300-nL volumes after 30 passes through the heated zones. The total reaction time was approximately 45 min, and the detection interval between individual samples was 1 min. Automation and the possibility to further reduce sample volumes, as well as to employ many reaction columns simultaneously, should provide a platform for an extremely high throughput.

Automation↗

Characterization of micromachined hollow tips for two-dimensional nanoelectrospray mass spectrometry.

In this work an improved design of chip-based nanoelectrospray nozzles is reported. Two-dimensional matrices of out-of-plane 10 microm i.d. silicon dioxide tips with a tapered shape were manufactured using deep reactive ion etching technology. Using a peptide sample, six micromachined tips and six commercially pulled silica capillary tips were compared employing an ion trap mass spectrometer. At a flow rate of 100 nL/min, the detectability obtained was approximately the same for the two types of tips. The relative standard deviation of the signal-to-noise ratio for the peptides between six different tips was on average 22% for the micromachined tips and 45% for the pulled capillary tips. The usefulness of the micromachined tips for analysis of non-covalent protein-ligand complexes was demonstrated by the analysis of a sample of RNase A and cytidine 2'-monophosphate. In another test, analyzing a tryptic digest of 1 pmol/microL cytochrome C, 18 peptides corresponding to a 82% sequence coverage were detected. Using MS/MS, the whole sequence of an 11 amino acid cytochrome C fragment was obtained. Computer simulations were performed on the shape and magnitude of the electrical field around micromachined and pulled capillary tips. To reach the threshold electric field density at the tip apex required to initiate an electrospray, a higher electrospray voltage was needed for the chip-based tips compared with pulled capillary tips. This is due to the influence of the chip base.

Animals↗

Automated nano-electrospray mass spectrometry for protein-ligand screening by noncovalent interaction applied to human H-FABP and A-FABP.

A method for ligand screening by automated nano-electrospray ionization mass spectrometry (nano-ESI/MS) is described. The core of the system consisted of a chip-based platform for automated sample delivery from a 96-well plate and subsequent analysis based on noncovalent interactions. Human fatty acid binding protein, H-FABP (heart) and A-FABP (adipose), with small potential ligands was analyzed. The technique has been compared with a previously reported method based on nuclear magnetic resonance (NMR), and excellent correlation with the found hits was obtained. In the current MS screening method, the cycle time per sample was 1.1 min, which is approximately 50 times faster than NMR for single compounds and approximately 5 times faster for compound mixtures. High reproducibility was achieved, and the protein consumption was in the range of 88 to 100 picomoles per sample. Futhermore, a novel protocol for preparation of A-FABP without the natural ligand is presented. The described screening approach is suitable for ligand screening very early in the drug discovery process before conventional high-throughput screens (HTS) are developed and/or used as a secondary screening for ligands identified by HTS.

Adipocytes↗

Multiplex high-throughput solid-phase minisequencing by capillary electrophoresis and liquid core waveguide fluorescence detection.

Minisequencing, solid-phase single-nucleotide primer extension reaction, is a robust method for performing multiplex single-nucleotide polymorphism (SNP) analysis. We have combined this technology with capillary gel electrophoresis in a multicapillary format, using liquid core waveguide (LCW) fluorescence detection. Polymerase chain reaction (PCR) amplification of multiple DNA targets is performed with one primer for each target biotinylated. Separation of the complementary strands, minisequencing and washing steps are carried out using streptavidin-coated magnetic beads. Dideoxynucleotides analogues labelled with different fluorophores are used for the extension of the minisequencing primers. The extended oligonucleotides, the length of which defines the position on the target and the color the identity of the polymorphism, are then separated in a gel-filled array of capillaries, coated on the outside with a layer of a fluoropolymer to provide the liquid core waveguide characteristics. The technology has a potential for extremely high throughputs when a combination of multiplex PCR-minisequencing is used together with a large array of capillaries, four-color detection and high-speed separation.

DNA↗

On-line microdialysis for enhanced resolution and sensitivity during electrospray mass spectrometry of non-covalent complexes and competitive binding studies.

Many proteins and macromolecules easily form metal adduct ions which impairs their analysis by mass spectrometry. The present study describes how the formation of undesired adducts can be minimized by on-line microdialysis for non-covalent binding studies of macromolecules with low molecular mass ligands with electrospray ionization mass spectrometry (ESI-MS). The technique was indispensable for protein-ligand studies due to reduction of unwanted adduct ions, and thus gave excellent resolution and a sensitivity improvement of at least 5 times. The core of the analytical system was a modified microdialysis device, which was operated in countercurrent mode. A novel technique based on microdialysis for competitive binding studies is also presented. The non-covalent complex between a protein and a ligand was formed in the sample vial prior to analysis. The complex was injected into an on-line microdialysis system where a competitive ligand was administered in the dialysis buffer outside of the fiber. The second ligand competitively displaced the first ligand through transport via the wall of the dialysis fiber, and the intact complexes were detected by ESI-MS.

Animals↗

Characterization of proteinases from Antarctic krill (Euphausia superba).

Fractions of three trypsin-like proteinases, TL I, TL II, and TL III, a chymotrypsin-like proteinase, CL, two carboxypeptidase A enzymes, CPA I and CPA II and two carboxypeptidase B enzymes, CPB I and CPB II, from Antarctic krill (Euphausia superba) have been characterized with respect to purity by the means of capillary electrophoresis, CE, and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS). The masses of the trypsin-like and chymotrypsin-like proteinases were determined to be 25,020, 25,070, 25,060, and 26,260Da for TL I, TL II, TL III, and CL, respectively. The masses of the CPA enzymes are likely 23,170 and 23,260Da, whereas the CPB enzyme masses likely are 33,730 and 33,900Da. The degradation efficiency and cleavage pattern of the trypsin-like proteinases were studied with native myoglobin as a model substrate using CE, MALDI-TOF-MS, and nanoelectrospray mass spectrometry (nESI-MS). The degradation efficiency of the trypsin-like proteinases was found to be approximately 12 and 60 times higher compared to bovine trypsin at 37 degrees C and 1-3 degrees C, respectively. All three fractions of trypsin-like proteinases showed a carboxypeptidase activity in combination with their trypsin activity.

Animals↗