Search PubMed⌕ Search

Biomedical subjects

Johan Roeraade

Publications and source records attributed to Johan Roeraade.

At least 19 recordsLinked to original sources

Picoliter droplet formation on thin optical fiber tips.

In this paper, we present experimental results on how minute droplets are formed on fiber optic end faces. Results show that reproducible picoliter volumes can be generated when fibers are retracted from an aqueous phase contained under an inert fluorinated immiscible liquid, with a coefficient of variation (CV) of 0.7-2.3%. The droplet formation was analyzed as a function of the fiber diameter, retraction speed, and wettability. Experiments reveal a volume-determining critical equilibrium contact angle between 60 degrees and 75 degrees , defining the onset of fiber end-face dewetting. The dynamics of the droplet snap-off progression was characterized using high-speed imaging in order to explain the observed wettability-volume dependency.

Journal Article↗

Automated microdroplet platform for sample manipulation and polymerase chain reaction.

We present a fully automated system performing continuous sampling, reagent mixing, and polymerase chain reaction (PCR) in microdroplets transported in immiscible oil. Sample preparation and analysis are totally automated, using an original injection method from a modified 96-well plate layered with three superimposed liquid layers and in-capillary laser-induced fluorescence endpoint detection. The process is continuous, allowing sample droplets to be carried uninterruptedly into the reaction zone while new drops are aspirated from the sample plate. Reproducible amplification, negligible cross-contamination, and detection of low sample concentrations were demonstrated on numerous consecutive sample drops. The system, which opens the route to strong reagents and labor savings in high-throughput applications, was validated on the clinically relevant quantification of progesterone receptor gene expression in human breast cancer cell lines.

Automation↗

C-terminal ladder sequencing of peptides using an alternative nucleophile in carboxypeptidase Y digests.

A method for improved sequence coverage in C-terminal sequencing of peptides, based on carboxypeptidase digestion, is described. In conventional carboxypeptidase digestions, the peptide substrate is usually extensively degraded and a full amino acid sequence cannot be obtained due to the lack of a complete peptide ladder. In the presented method, a protecting group is introduced at the C terminus of a fraction of the peptide fragments formed in the digest, and thereby further degradation of the C-terminally modified peptides are slowed down. The protecting group was attached to the C-terminal amino acid through a carboxypeptidase-catalyzed reaction with an alternative nucleophile, 2-pyridylmethylamine, added to the aqueous digestion buffer. Six peptides were digested by carboxypeptidase Y with and without 2-pyridylmethylamine present in the digest buffer, and the resulting fragments subsequently were analyzed with matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). Comparison of the two digestion methods showed that the probability of successful ladder sequencing increased, by more than 50% using 2-pyridylmethylamine as a competing nucleophile in carboxypeptidase Y digests.

Cathepsin A↗

Multi-step dielectrophoresis for separation of particles.

A new concept for separation of particles based on repetitive dielectrophoretic trapping and release in a flow system is proposed. Calculations using the finite element method have been performed to envision the particle behavior and the separation effectiveness of the proposed method. As a model system, polystyrene beads in deionized water and a micro-flow channel with arrays of interdigited electrodes have been used. Results show that the resolution increases as a direct function of the number of trap-and-release steps, and that a difference in size will have a larger influence on the separation than a difference in other dielectrophoretic properties. About 200 trap-and-release steps would be required to separate particles with a size difference of 0.2%. The enhanced separation power of dielectrophoresis with multiple steps could be of great importance, not only for fractionation of particles with small differences in size, but also for measuring changes in surface conductivity, or for separations based on combinations of difference in size and dielectric properties.

Electrodes↗

Electrospray ionization from a gap with adjustable width.

In this paper, we present a new concept for electrospray ionization mass spectrometry, where the sample is applied in a gap which is formed between the edges of two triangular-shaped tips. The size of the spray orifice can be changed by varying the gap width. The tips were fabricated from polyethylene terephthalate film with a thickness of 36 microm. To improve the wetting of the gap and sample confinement, the edges of the tips forming the gap were hydrophilized by means of silicon dioxide deposition. Electrospray was performed with gap widths between 1 and 36 microm and flow rates down to 75 nL/min. The gap width could be adjusted in situ during the mass spectrometry experiments and nozzle clogging could be managed by simply widening the gap. Using angiotensin I as analyte, the signal-to-noise ratio increased as the gap width was decreased, and a shift towards higher charge states was observed. The detection limit for angiotensin I was in the low nM range.

Equipment Design↗

Determination of conductivity of bacteria by using cross-flow filtration.

An important property of the bacterial surface is its conductivity. To obtain reliable conductivity values, it is essential to handle the cells as gently as possible during the measurement procedure. We have developed a method where a standard conductivity meter is used in combination with cross-flow filtration, thus avoiding repeated centrifugation and resuspension. With this method, the conductivity of Bacillus subtilis was determined to be 7,000 microS/cm, which is a deviation from previously published data by almost an order of a magnitude.

Bacillus subtilis↗

Method for analysis of polar volatile trace components in aqueous samples by gas chromatography.

A new method has been developed for direct analysis of volatile polar trace compounds in aqueous samples by gas chromatography. Water samples are injected onto a short packed precolumn containing anhydrous lithium chloride. A capillary column is coupled in series with the prefractionation column for final separation of the analytes. The enrichment principle of the salt precolumn is reverse to the principles employed in conventional methods such as SPE or SPME in which a sorbent or adsorbent is utilized to trap or concentrate the analytes. Such methods are not efficient for highly polar compounds. In the LiCl precolumn concept, the water matrix is strongly retained on the hygroscopic salt, whereas polar as well as nonpolar volatile organic compounds show very low retention and are eluted ahead of the water. After transfer of the analytes to the capillary column, the retained bulk water is removed by backflushing the precolumn at elevated temperature. For direct injections of 120 microL of aqueous samples, the combined time for injection and preseparation is only 3.5 min. With this procedure, direct repetitive automated analyses of highly volatile polar compounds such as methanol or tetrahydrofuran can be performed, and a limit of quantification in the low parts-per-billion region utilizing a flame ionization detector is demonstrated.

Journal Article↗

Chip with twin anchors for reduced ion suppression and improved mass accuracy in MALDI-TOF mass spectrometry.

A new sample target for matrix-assisted laser desorption/ionization mass spectrometry is described. The target consists of pairs of elevated hydrophilic anchor surfaces, positioned in proximity onto a microchip. The anchors are used to obtain separate preparations of sample and external standard, while both anchor surfaces are irradiated simultaneously by the laser pulse. Using a standard, based on six peptides, a 2-fold improvement in mass accuracy is observed. Also, ion suppression is significantly reduced. With a one peptide calibration standard, 22 tryptic fragments from a BSA digest are detected using the twin-anchor concept, whereas only 14 fragments are detected when the sample and standard are laser-ablated as a mixture from a conventional anchor target. A volume of approximately 30 pL of sample solution of angiotensin I is transferred to the anchor surface, under a thin layer of a perfluorocarbon, to prevent a concentration bias due to evaporation. With this arrangement, a detection limit of 1.5 amol was achieved with a signal-to-noise ratio of 22:1.

Adrenocorticotropic Hormone↗

Superpositioned dielectrophoresis for enhanced trapping efficiency.

One of the major applications for dielectrophoresis is selective trapping and fractionation of particles. If the surrounding medium is of low conductivity, the trapping force is high, but if the conductivity increases, the attraction decreases and may even become negative. However, high-conductivity media are essential when working with biological material such as living cells. In this paper, some basic calculations have been performed, and a model has been developed which employs both positive and negative dielectrophoresis in a channel with interdigitated electrodes. The finite element method was utilized to predict the trajectories of Escherichia coli bacteria in the superpositioned electrical fields. It is shown that a drastic improvement of trapping efficiency can be obtained in this way, when a high conductivity medium is employed.

Electric Conductivity↗

Investigation of multiple binding sites on ribonuclease A using nano-electrospray ionization mass spectrometry.

Multiple non-active site interactions between ribonuclease A (RNAse) and selected target molecules were investigated using nano-electrospray ionization mass spectrometry (nano-ESI-MS). Among the building blocks of RNA, phosphate and ribose showed such multiple interactions. Multiple phosphate interactions survived a high cone voltage, while multiple interactions with D-ribose disappeared already at a low cone voltage. Using nano-ESI-MS, only cytosine among the individual bases appeared to interact with RNAse. Interestingly, guanosine binds to the RNAse surface at high cone voltage, probably as a result of cooperative binding of the sugar and the guanine base. Upon binding of deoxycytidine oligonucleotides with six (dC6), nine (dC9) and twelve (dC12) deoxycytidine nucleotide units to RNAse, the dC12 unit showed the strongest interaction. Upon collision-induced dissociation (CID) of the RNAse/dC6 complex, this complex survived dissociation at an energy level where covalently bound cytosine from dC6 was lost. This is in contrast to CID of RNAse complexed with mononucleotide cytidine 2'-monophosphate (CMP), which dissociates from the protein without breaking of covalent bonds.

Binding Sites↗

Electrospray ionization mass spectrometry as a tool for determination of drug binding sites to human serum albumin by noncovalent interaction.

Most proteins in blood plasma bind ligands. Human serum albumin (HSA) is the main transport protein with a very high capacity for binding of endogenous and exogenous compounds in plasma. Many pharmacokinetic properties of a drug depend on the level of binding to plasma proteins. This work reports studies of noncovalent interactions by means of nanoelectrospray ionization mass spectrometry (nanoESI-MS) for determination of the specific binding of selected drug candidates to HSA. Warfarin, iopanoic acid and digitoxin were chosen as site-specific probes that bind to the main sites of HSA. Two drug candidates and two known binders to HSA were analyzed using a competitive approach. The drugs were incubated with the target protein followed by addition of site-specific probes, one at a time. The drug candidates showed predominant affinity to site I (warfarin site). Naproxen and glyburide showed affinity to both sites I and II. The advantages of nanoESI-MS for these studies are the sensitivity, the absence of labeled molecules and the short method development time.

Binding Sites↗

Ultra thick film open tubular traps with an increased inner diameter.

In this paper, the concept of open tubular traps, coated with a very thick film of polydimethyldisiloxane for enrichment of trace volatile components has been further explored. From theoretical calculations as well as practical experiments it is demonstrated that it can be advantageous to increase the inner diameter of such traps. For a given sampling flow rate and phase ratio, the plate number of the traps is not dependent on the inner diameter, provided that the linear flow velocity remains sufficiently high to offset the effect of axial diffusion. It is shown that this is due to the basic fact that for a given sampling flow rate, the average linear flow velocity in the trap is inversely proportional to the square of the inner diameter of the trap. However, in contrast to chromatographic separations, the linear flow velocity is not important. Under conditions of a constant phase ratio, an increased inner diameter also increases the amount of sorbent in the trap, which is a key parameter for obtaining high breakthrough volumes. Open tubular traps with an expanded inner diameter have very low pressure drop characteristics, which provides the possibility to construct new, simplified sampling systems.

Chromatography↗

Thick film traps with an irregular film. Preparation and evaluation.

A new method for preparation of sorbent-based ultra-thick film traps for concentration of trace volatile components from gaseous matrices is described. The procedure is based on blowing a prepolymer (polydimethylsiloxane) through a capillary tube, forming an irregular film of stationary phase. Subsequently, the prepolymer is immobilized in a few seconds by heating to 200 degrees C. Evaluation of the performance of the new traps showed that the loss of efficiency, compared to regular smooth film traps is only on the order of 20-30%. In terms of breakthrough volume, this loss in performance is rather insignificant. The technology is extremely simple and allows a rapid and cheap production of a large number of ultra-thick film traps, even in non-specialized laboratories. The method can be applied to any type of cross-linkable stationary phase, thereby expanding the scope of sorbent-based trapping and preconcentration concept. Many applications are anticipated in trace and ultra-trace analysis in a wide range of fields, such as environmental chemistry, polymers, food and process analysis.

Dimethylpolysiloxanes↗

Automated high-capacity sorption probe for extraction of organic compounds in aqueous samples followed by gas chromatographic analysis.

An automated high-capacity sorption device for GC analysis of ultra trace components has been developed. The scope of the presented technique was to combine the simplicity of solid-phase microextraction (SPME) with the high extraction efficiency of the stir bar sorptive extraction technology. Sorptive extractions of water samples were performed using polydimethylsiloxane (PDMS) rubber tubing (120 microl) mounted onto a glass rod. The sampling procedure was carried out by a robotic autoinjector. Since the setup is fully automated, unattended and precise time-controlled extraction of samples is possible and makes quantitation with non-equilibrium extractions feasible. The sorption probes are easy to exchange, which facilitates off-line/in-field sampling. The system was evaluated with a test mixture of 44 environmentally hazardous compounds. Detection limits were found to be in the sub-ppt region. The performance of the system was demonstrated with the analysis of polycyclic aromatic hydrocarbons in urban snow.

Calibration↗

Nanowires for surface enlargement of narrow-bore fused-silica tubing.

A method for preparation of silica nanowires with dimensions of d = 10-100 nm, l = 5-500 nm, is described. The nanostructured material is an integral part of the inner surface of narrow bore fused-silica capillary tubing. The wire preparation method is based on a decomposition of 2-chloro-1,1,2-trifluoroethyl methyl ether at elevated temperature and pressure. The silica bulk material is rearranged via a sustained silica-hydrogen fluoride chemistry, and reaction mechanisms for this process are proposed. The method is suitable for preparing long lengths of tubing with the modified surface. It is our belief that the texture of the capillary wall with its increased surface area is useful for applications such as microreactions, catalysis, and high-resolution pressure and/or electrodriven open-tubular liquid chromatography.

Chromatography, Liquid↗

Influence of droplet size, capillary-cone distance and selected instrumental parameters for the analysis of noncovalent protein-ligand complexes by nano-electrospray ionization mass spectrometry.

It has been suggested in the literature that nano-electrospray ionization (nano-ESI) mass spectrometry better reflects the equilibrium between complex and free protein in solution than pneumatically assisted electrospray ionization (ESI) in noncovalent interaction studies. However, no systematic studies of the effects of ionization conditions have been performed to support this statement. In the present work, different instrumental and sample-derived parameters affecting the stability of noncovalent complexes during analysis by nano-ESI were investigated. In general, increased values of parameters such as drying gas flow-rate, ion-source temperature, capillary tip voltage and buffer concentration lead to a dissociation of ribonuclease A (RNAse)-cytidine 2'-monophosphate (CMP) and cytidine 5'-triphosphate (CTP) complexes. The size of the electrosprayed droplets was shown to be an important issue. Increasing the capillary to cone distance yielded an increased complex to free protein ratio when a hydrophilic ligand was present and the reverse effect was obtained with a hydrophobic ligand. Important in this regard is the degree of sampling of ions originating from late-generation residue droplets, that is, ions present in the droplet bulk. Sampling of these ions increases with longer capillary-cone distance (flight time). Furthermore, when the sample flow-rate was increased by increasing the capillary internal tip i.d. from 4 to 30 microm, a decreased complex to free protein ratio for the RNAse-CTP system was observed. This behavior was consistent with the change in surface to volume ratio for flow-rates between 2 and 100 nl min(-1). Finally, polarity switching between positive and negative ion modes gave a higher complex to free protein ratio when the ligand and the protein had the same polarity.

Animals↗

Polymer-assisted laser desorption/ionization analysis of small molecular weight compounds.

The use of non-polar, small polymers as matrices for the analysis of low molecular weight compounds in polymer-assisted laser desorption/ionization mass spectrometry (PALDI-MS) is demonstrated. The matrices evaluated were either based on an oligothiophene or a benzodioxin backbone. Metallocenes, polycyclic hydrocarbons, a fluorosurfactant, and a subset of small organic compounds with various functionalities, served as model analytes. The mechanism of ionization charge transfer is discussed and ionization potentials for the matrices in the study have been estimated using density functional theory (DFT) calculations. Some of the results are possibly contradictory to the generally accepted limiting conditions for gas-phase charge-transfer reactions. These results are interpreted in the light of energy pooling. Also a new mass calibration procedure for the low-mass region in positive ion mode is presented, and some aspects of the ionization/desorption process leading to radical cations are studied.

Molecular Weight↗

Simple fabrication of a structured matrix-assisted laser desorption/ionization target coating for increased sensitivity in mass spectrometric analysis of membrane proteins.

A new prestructured target plate for matrix-assisted laser desorption/ionization (MALDI) was developed specifically for hydrophobic integral membrane proteins. This sample support contains predefined concentrating sample spots with a focusing effect on droplets with a high content of hexafluoroisopropanol (HFIP). This fluorinated organic solvent is advantageous for solubilizing hydrophobic proteins that are not soluble in water or the organic solvents normally used in sample preparation protocols for MALDI-MS. The prestructured plate was constructed by coating a regular steel plate with a thin layer of a silicone polymer, leaving sample spots of bare steel. Fabrication of the concentrating silicone structure was fast and very straightforward, without expensive or complicated equipment. Removing the layer, and thus regenerating the steel plate, was done by a simple washing procedure. The application and cleaning procedure are not constrained by a particular design of sample support or to any specific brand of mass spectrometer. When using the prestructured MALDI plate with HFIP as the sample solvent for 17 pmol of a cyanogen bromide digest of the highly hydrophobic membrane protein bacteriorhodopsin, an improved focusing effect and an increase of more than five-fold in average sensitivity were observed, compared with a regular steel target. Experimental results show a two-fold increase in average sensitivity when the new prestructured target plate was used, compared with a commercially available concentrating support.

Amino Acid Sequence↗