Search PubMed⌕ Search

Biomedical subjects

James D Thomas

Publications and source records attributed to James D Thomas.

At least 55 records · Page 3Linked to original sources

Abnormalities of Doppler measures of diastolic function in the healthy elderly are not related to alterations of left atrial pressure.

BACKGROUND: Normal healthy aging results in changes in Doppler indexes of diastolic function. One widely accepted explanation for these alterations that is based on animal data is an age-associated impairment of myocardial relaxation resulting from abnormal myocyte calcium handling. However, an alternative theory based on altered left atrial compliance with aging has been proposed in which early left atrial pressure could be low in the aged heart but rise rapidly during atrial diastole, resulting in a higher late atrial pressure and thus a normal mean pressure. We sought to explore this issue directly by performing a detailed analysis of the pulmonary capillary wedge pressure waveform obtained by right-heart catheterization during 5 different loading conditions. METHODS AND RESULTS: Twelve healthy elderly sedentary subjects (mean age, 69.8+/-3 years) were recruited for the seniors group. An additional 12 young sedentary subjects (mean age, 35+/-8 years) made up the young group. All subjects were rigorously screened for comorbidities. All subjects underwent transthoracic echocardiography to determine Doppler variables of early and late transmitral filling (E and A velocities) and isovolumetric relaxation time. Each subject also underwent pulmonary artery catheterization with measurement of pulmonary capillary wedge pressure waveform during 5 different loading conditions: baseline, lower-body negative pressures of -15 and -30 mm Hg, and rapid saline infusions of 10 to 15 and 20 to 30 mL/kg. Pressure was measured at 6 points of the waveform: point 1, peak of the atrial contraction (a wave); point 2, the left atrial pressure during the start of ventricular systole; point 3, peak of atrial filling (v wave); point 4, earliest left atrial pressure during ventricular filling; and the line between points 5 and 6, pressure during diastasis. Aging resulted in a decrease in the E/A ratio (P<0.001) and a prolongation of the isovolumetric relaxation time (P<0.001) as assessed by echocardiography, but there was no effect of age on pulmonary capillary wedge pressure at any point throughout the cardiac cycle (P=0.290). Specifically, at no measured point at any level of cardiac filling volume was the pulmonary capillary wedge pressure of the seniors lower than that of the young subjects. CONCLUSIONS: We conclude that the age-related echocardiographic change of decreasing E/A ratio is not the result of a lowering of early diastolic left atrial pressure.

Adult↗

Assessment of left ventricular torsional deformation by Doppler tissue imaging: validation study with tagged magnetic resonance imaging.

BACKGROUND: Left ventricular (LV) torsional deformation is a sensitive index for LV performance but difficult to measure. The present study tested the accuracy of a novel method that uses Doppler tissue imaging (DTI) for quantifying LV torsion in humans with tagged magnetic resonance imaging (MRI) as a reference. METHODS AND RESULTS: Twenty patients underwent DTI and tagged MRI studies. Images of the LV were acquired at apical and basal short-axis levels to assess LV torsion. We calculated LV rotation by integrating the rotational velocity, determined from DTI velocities of the septal and lateral regions, and correcting for the LV radius over time. LV torsion was defined as the difference in LV rotation between the 2 levels. DTI rotational and torsional profiles throughout systole and diastole were compared with those by tagged MRI at isochronal points. Rotation and torsion by DTI were closely correlated with tagged MRI results during systole and early diastole (apical and basal rotation, r=0.87 and 0.90, respectively; for torsion, 0.84; P<0.0001, by repeated-measures regression models). Maximal torsion showed even better correlation (r=0.95, P<0.0001). CONCLUSIONS: The present study has shown that DTI can quantify LV torsional deformation over time. This novel method may facilitate noninvasive quantification of LV torsion in clinical and research settings.

Aortic Valve Insufficiency↗

Tricuspid valve tethering predicts residual tricuspid regurgitation after tricuspid annuloplasty.

BACKGROUND: Tricuspid valve (TV) annuloplasty is recommended for functional tricuspid regurgitation (TR), which is caused by TV annulus dilatation and tethering of the leaflets. However, the impact of TV deformations on the outcome of TV annuloplasty remains unknown. The goal of this study was to investigate the relationship between preoperative TV deformation and residual TR after TV annuloplasty. METHODS AND RESULTS: Two hundred sixteen patients with functional TR had 2D echocardiography before and after TV annuloplasty. Right ventricular fractional area change and left ventricular ejection fraction were determined with the apical views. Minimal TV annulus diameter was determined by frame-by-frame analysis. The distance of TV tethering was measured from the annulus plane to the coaptation point and tethering area by tracing the leaflets from the annulus plane. TR severity was determined by the ratio of the maximal jet area to the corresponding right atrial area. The severity of residual TR was associated with age, right and left ventricular dysfunction, tethering distance and area, and severity of preoperative TR (all P<0.05). TV annular dimension was not associated with outcome of TV annuloplasty. Multivariate analysis revealed that age, tethering distance, and severity of preoperative TR (all P<0.001) were independent parameters predicting residual TR. The sensitivity and specificity in predicting residual TR after surgery were 86% and 80% for tethering distances >0.76 cm and 82% and 84% for tethering areas >1.63 cm2, respectively. CONCLUSIONS: Severe TV tethering predicted residual TR after TV annuloplasty, whereas preoperative TV annular dimension was not associated with outcome of TV annuloplasty.

Aged↗

Evaluation of left ventricular outflow tract area after septal reduction in obstructive hypertrophic cardiomyopathy: a real-time 3-dimensional echocardiographic study.

BACKGROUND: The comparative impact of percutaneous alcohol septal reduction (ASR) and surgical myectomy on the left ventricular outflow tract (LVOT) area in patients with obstructive hypertrophic cardiomyopathy (HC) is not well defined. Real-time 3-dimensional echocardiography (RT3DE) provides accurate information about the LVOT geometry and shape. We aimed to analyze the change in LVOT area after septal reduction interventions in patients with obstructive HC using RT3DE. METHODS: Thirty-one HC patients (mean age 53 +/- 17 years) undergoing ASR (n = 14) or myectomy (n = 17) were studied at baseline and during follow-up with RT3DE. LVOT area was measured after observing the LVOT in the 3D space as the smallest area during midsystole. LVOT pressure gradients were determined by conventional continuous wave Doppler. RESULTS: Overall, LVOT area increased from 0.86 +/- 0.20 to 2.50 +/- 0.88 cm2 (P < .01), and the resting LVOT pressure gradient decreased from 64 +/- 41 to 16 +/- 10 mm Hg (P < .01) after a median follow-up of 3 months after intervention (range 1-24 months). A similar significant decrease in LVOT pressure gradients was seen in myectomy and ASR groups (from 62 +/- 39 to 12 +/- 5 mm Hg and from 67 +/- 43 to 21 +/- 14 mm Hg, respectively, P < .01 in between each group, and P = NS between both groups). However, the increase in LVOT area was greater in myectomy than in ASR group (from 0.81 +/- 0.22 to 2.90 +/- 0.64 cm2 and 0.93 +/- to 0.16 to 2.02 +/- 0.92 cm2, respectively, P < .01 between both groups). CONCLUSION: RT3DE demonstrated an effective increase in LVOT area after both ASR and myectomy. This technique may be useful for assessing the results of septal reduction in patients with obstructive HC.

Adolescent↗

Aortic valve replacement in patients with mild or moderate aortic stenosis and coronary bypass surgery.

PURPOSE: To assess whether there is survival benefit for patients with mild or moderate aortic stenosis if they undergo aortic valve replacement at the time of coronary artery bypass surgery. METHODS: From 1985 to 1995 we evaluated all patients at our institution who underwent coronary artery bypass surgery and who had the echocardiographic diagnosis of mild (mean gradient <0 mm Hg and/or valve area >1.5 cm(2)) or moderate (mean gradient > or =30 and < or =40 mm Hg and/or valve area >1.0 < or =1.5 cm(2)) aortic stenosis. Using propensity analysis, survival was compared between 129 patients who underwent coronary artery bypass surgery alone and 78 patients who underwent concomitant coronary artery bypass surgery and aortic valve replacement. RESULTS: Perioperative mortality was similar among patients who underwent coronary artery bypass surgery alone compared with patients who underwent concomitant coronary artery bypass surgery and aortic valve replacement. By Kaplan-Meier analysis, 1-year and 8-year survival were better at 90% and 55% for patients who underwent concomitant coronary artery bypass surgery and aortic valve replacement compared with 85% and 39% for patients who underwent coronary artery bypass surgery alone (P <0.001). This benefit was limited to patients with moderate aortic stenosis (propensity-adjusted relative risk = 0.43; 95% confidence interval: 0.20 to 0.96; P = 0.04). CONCLUSION: Concomitant aortic valve replacement at the time of coronary artery bypass surgery for mild or moderate aortic stenosis appears to convey a survival advantage for patients with moderate aortic stenosis but not for those with mild aortic stenosis.

Aged↗

Automated mitral annular tracking: a novel method for evaluating mitral annular motion using two-dimensional echocardiography.

We developed an automated mitral annular tracking method based on a digital processing of high frame rate cineloop images of 2-dimensional echocardiography. In this study, its feasibility and accuracy was validated in 11 healthy volunteers and 16 patients with left ventricular (LV) dysfunction. The mitral annular excursion measured by automated mitral annular tracking agreed well with that measured by 3-dimensional echocardiography and correlated with LV ejection fraction. The longitudinal mitral annular excursion was reduced whereas the radial one was preserved for patients with LV dysfunction compared with control subjects. The novel automated mitral annular tracking method is clinically feasible and has potential capability to quantify the comprehensive mitral annular motion for evaluating LV function in a clinical setting.

Adult↗

Giant flow reversal in pulmonary venous flow as a possible mechanism for asynchronous pacing-induced heart failure.

BACKGROUND: Mechanistic roles of the immediate increase in left atrial (LA) pressure in pacing-induced congestive heart failure have not been clearly understood. We evaluated the impact of asynchronous rapid ventricular pacing on LA hemodynamics in this model. METHODS: Transthoracic and transesophageal echocardiography and hemodynamic assessment were performed in 23 healthy mongrel dogs. Data were acquired before and 5 minutes after initiation of rapid right ventricular pacing (200/min). RESULTS: At 5 minutes after initiation of the pacing, giant pulmonary venous (PV) flow reversal (-76 cm/s) was observed in association with 1:1 ventriculoatrial conduction or complete atrioventricular dissociation. This giant PV flow reversal corresponded to an inappropriately timed atrial contraction, especially during systole. Cardiac output (3.21 vs 2.00 L/min, P < .001) was decreased corresponding to the decrease in the forward blood volumes as described by decrease in the Doppler left ventricular (LV) outflow (8.99 vs 4.73 cm, P < .0001), mitral inflow (6.89 vs 3.19 cm, P < .0001), and PV flow (14.15 vs 7.22 cm, P < .0001) velocity integrals. As a result, there was a marked elevation of the mean pulmonary capillary wedge (9.1 vs 17.1 mm Hg, P < .001) and LV end-diastolic (8.2 vs 17.4 mm Hg, P < .01) pressures leading to congestive heart failure. CONCLUSIONS: The giant PV flow reversal seen during asynchronous rapid right ventricular pacing corresponds to an inappropriate atrial contraction, immediately elevates LA pressure, and may initially promote congestive heart failure. The increase in LV end-diastolic pressure associated with decreased LV ejection fraction caused decrease in the LV filling volume leading to further increase in the LA pressure. This sustained marked elevation in the LA pressure and LV end-diastolic pressure could contribute to the heart failure process.

Animals↗

Mitral annulus size links ventricular dilatation to functional mitral regurgitation.

We compared the impact of annulus size and valve deformation (tethering) on mitral regurgitation in the animal dilated cardiomyopathy model, and assessed if acute left ventricular volume changes affect mitral annulus dimensions. We performed 3-dimensional echocardiography in 30 open-chest dogs with pacing-induced cardiomyopathy. Mitral annulus area was calculated from its two orthogonal diameters, whereas valve tethering was quantified by valve tenting area measurement. Mitral valve regurgitant volume showed the highest correlation with annulus area (r = 0.64, P < .001), left atrial volume (r = 0.40, P < .01), and left ventricular end-diastolic volume (r = 0.37, P < .01). Regurgitant volume showed poorer correlation with valve tethering in both septolateral and intercommissural planes (r = 0.35 and r = 0.31, P < .05 for both). Annulus dimensions correlated with acute changes of left ventricular end-diastolic volume (r = 0.68, P = .002). Mitral annulus dilation is the strongest predictor of functional mitral regurgitation in this animal dilated cardiomyopathy model.

Animals↗

Quantitative analysis of left atrial function during left ventricular ischemia with and without left atrial ischemia: a real-time 3-dimensional echocardiographic study.

Left atrial (LA) systolic and diastolic function were analyzed in an animal model of acute left ventricular ischemia with LA ischemia by proximal left circumflex coronary artery occlusion or without LA ischemia by midleft anterior descending coronary artery occlusion (7 sheep in each group). LA pressures and LA volumes were simultaneously recorded using a catheter and real-time 3-dimensional echocardiography, respectively. LA stroke volume represented 63% of left ventricular stroke volume during left anterior descending coronary artery occlusion, but only 32% during left circumflex coronary artery occlusion. This animal study with 3-dimensional echocardiographic determination of absolute LA volumes demonstrated dramatic depression of LA function during proximal left circumflex coronary artery occlusion as compared with left anterior descending coronary artery occlusion.

Animals↗

Planimetric assessment of anatomic valve area overestimates effective orifice area in bicuspid aortic stenosis.

BACKGROUND: Although the continuity equation remains the noninvasive standard, planimetry using transesophageal echocardiography is often used to assess valve area for patients with aortic stenosis (AS). Not uncommonly, however, anatomic valve area (AVAA) obtained by planimetry overestimates continuity-derived effective valve area (AVAE) in bicuspid AS. METHODS: Transthoracic Doppler and transesophageal echocardiography were performed to obtain AVAE and AVAA in 31 patients with bicuspid AS (age 61 +/- 11 years) and 22 patients with degenerative tricuspid AS (age 71 +/- 13 years). Aortic root and left ventricular outflow tract dimensions and the directional angle of the stenotic jet were assessed in all patients. Using these data, a computational fluid dynamics model was constructed to test the effect of these variables in determining the relationship between AVAE and AVAA. RESULTS: For patients with tricuspid AS, the correlation between AVAA (1.15 +/- 0.36 cm2) and AVAE (1.13 +/- 0.46 cm2) was excellent (r = 0.91, P < .001, Delta = 0.02 +/- 0.21 cm2). However, AVAA was significantly larger (1.19 +/- 0.35 cm2) than AVAE (0.89 +/- 0.29 cm2) in the bicuspid AS group (r = 0.71, P < .001, Delta = 0.29 +/- 0.25 cm2). Computer simulation demonstrated that the observed discrepancy related to jet eccentricity. CONCLUSION: For a given anatomic orifice, functional severity tends to be greater in bicuspid AS than in tricuspid AS. This appears to be primarily related to greater jet eccentricity and less pressure recovery.

Anatomy, Cross-Sectional↗

The accuracy of left ventricular mass determined by real-time three-dimensional echocardiography in chronic animal and clinical studies: a comparison with postmortem examination and magnetic resonance imaging.

Real-time 3-dimensional echocardiography (RT3DE), 2-dimensional echocardiography (2DE), and M-mode echocardiography were performed in 28 sheep with cardiac pathologies and 27 patients with heart disease to demonstrate the superiority of RT3DE over M-mode and 2DE for the determination of left ventricular mass. Postmortem examination and magnetic resonance imaging were used as a reference standard for the animal and clinical studies, respectively. In the animal study, the highest concordance correlation (0.92) was obtained between the actual weight of left ventricular mass and that estimated by RT3DE (0.69 for 2DE and 0.77 for M-mode, P < .001). In the clinical study, RT3DE also provided the best concordance correlation with left ventricular mass determined by magnetic resonance imaging (0.91 for RT3DE, 0.83 for 2DE, and 0.38 for M-mode; P < .0001).

Animals↗

Non-invasive evaluation of orthotopic heart transplant rejection by echocardiography.

BACKGROUND: Heart transplant recipients require frequent myocardial biopsies to screen for acute rejection. The purpose of this study was to identify demographic and echocardiographic factors associated with transplant rejection and develop a predictive model, which may reduce the number of cardiac biopsies. METHODS: From January 1998 to December 2001, we performed 406 echocardiographic studies on 264 heart transplant patients who had biopsies performed on the same day. Two-dimensional, pulsed and tissue Doppler echocardiographic variables were compared between patients with and without rejection, and their predictive ability for detecting rejection was determined by uni- and multivariate analyses. RESULTS: In 268 biopsies there was no significant rejection (ISHLT Grade <==II), whereas 138 showed rejection (ISHLT Grade > or =IIIa). By multivariate analysis, pericardial effusion, isovolumic relaxation time (IVRT) <90 milliseconds and mitral inflow E/A ratio >1.7, diameter of inferior vena cava and duration of pulmonary vein atrial reversal were independently associated with rejection. Because the odds ratios were similar for all 5 predictors, a simplified model was developed based on the sum of the number of abnormal predictors present (0 to 5). The probability of rejection increased from 15.9%, in the absence of any predictor, to 39.7%, 52.0% and 71.1%, if 1, 2 or 3 predictors were present, respectively. CONCLUSIONS: Recipient age, pericardial effusion, IVRT and ratio of pulsed Doppler E/A are significant predictors of acute cardiac allograft rejection. However, no single predictor or combination of predictors were powerful enough to eliminate surveillance endomyocardial biopsies.

Adult↗

Usefulness of intracardiac Doppler assessment of left atrial function immediately post-pulmonary vein antrum isolation to predict short-term recurrence of atrial fibrillation.

Doppler assessments of pulmonary venous (PV) and left atrial appendage flows are useful surrogates of left atrial (LA) function, but it is unknown if these can predict atrial fibrillation (AF) recurrence after pulmonary vein antrum isolation. We compared Doppler surrogates of LA function immediately after pulmonary vein antrum isolation in patients with AF recurrence versus matched patients without recurrence. Patients with a 6-month recurrence had significantly lower LA appendage peak emptying velocity (19 +/- 10 vs 29 +/- 11 cm/s) and lower peak PV systolic wave velocity (36 +/- 17 vs 46 +/- 22 cm/s) compared with those without, suggesting that intracardiac Doppler assessment of LA function after AF ablation predicts AF recurrence.

Aged↗

Usefulness of real-time three-dimensional echocardiography for evaluation of myectomy in patients with hypertrophic cardiomyopathy.

Real-time 3-dimensional echocardiography was performed in 10 patients with obstructive hypertrophic cardiomyopathy (HC) before and after myectomy and in 6 controls. The exact location of systolic anterior motion of the mitral leaflet was shown in all patients with HC with a predominant involvement of the medial portion in 4 patients and the middle portion in 6 patients. The smallest area of the left ventricular outflow tract was significantly smaller in patients with HC than in controls (1.4 +/- 0.7 vs 5.1 +/- 1.2 cm(2), p <0.01), significantly increased after myectomy (4.8 +/- 1.8 cm2, p <0.01) and was associated with a reduction of the pressure gradient at rest from 63 +/- 41 to 15 +/- 5 mm Hg (p <0.01).

Adult↗

Effect of aging and physical activity on left ventricular compliance.

BACKGROUND: Left ventricular compliance appears to decrease with aging, which may contribute to the high incidence of heart failure in the elderly. However, whether this change is an inevitable consequence of senescence or rather secondary to reduced physical activity is unknown. METHODS AND RESULTS: Twelve healthy sedentary seniors (69.8+/-3 years old; 6 women, 6 men) and 12 Masters athletes (67.8+/-3 years old; 6 women, 6 men) underwent pulmonary artery catheterization to define Starling and left ventricular pressure-volume curves. Data were compared with those obtained in 14 young but sedentary control subjects (28.9+/-5 years old; 7 women, 7 men). Pulmonary capillary wedge pressures and left ventricular end-diastolic volumes by use of echocardiography were measured at baseline, during decreased cardiac filling by use of lower-body negative pressure (-15 and -30 mm Hg), and after saline infusion (15 and 30 mL/kg). Stroke volume for any given filling pressure was greater in Masters athletes compared with the age-matched sedentary subjects, whereas contractility, as assessed by preload recruitable stroke work, was similar. There was substantially decreased left ventricular compliance in healthy but sedentary seniors compared with the young control subjects, which resulted in higher cardiac pressures for a given filling volume and higher myocardial wall stress for a given strain. The pressure-volume curve for the Masters athletes was indistinguishable from that of the young, sedentary control subjects. CONCLUSIONS: A sedentary lifestyle during healthy aging is associated with decreased left ventricular compliance, leading to diminished diastolic performance. Prolonged, sustained endurance training preserves ventricular compliance with aging and may help to prevent heart failure in the elderly.

Aged↗

Effects of sodium nitroprusside in aortic stenosis associated with severe heart failure: pressure-volume loop analysis using a numerical model.

In the recently published clinical study [Use of Nitroprusside in Left Ventricular Dysfunction and Obstructive Aortic Valve Disease (UNLOAD)], sodium nitroprusside (SNP) improved cardiac function in patients with severe aortic stenosis (AS) and left ventricular (LV) systolic dysfunction. We explored the possible mechanisms of these findings using a series of numerical simulations. A closed-loop lumped parameters model that consists of 24 differential equations relating pressure and flow throughout the circulation was used to analyze the effects of varying hemodynamic conditions in AS. Hemodynamic data from UNLOAD study subjects were used to construct the initial simulation. Systemic vascular resistance (SVR), heart rate, and aortic valve area were directly entered into the model while end-systolic and end-diastolic pressure-volume (P-V) relationships were adjusted using previously published data to match modeled and observed end-systolic and end-diastolic pressures and volumes. Initial simulation of SNP treatment by a reduction of SVR was not adequate. To obtain realistic model hemodynamics that reliably reproduce SNP treatment effects, we performed a series of simulations while simultaneously changing end-systolic elastance (E(es)), end-systolic volume at zero pressure (V(0)), and diastolic P-V shift. Our data indicate that either an E(es) increase or V(0) decrease is necessary to obtain realistic model hemodynamics. In five patients, we corroborated our findings by using the model to duplicate individual P-V loops obtained before and during SNP treatment. In conclusion, using a numerical model, we identified ventricular function parameters that are responsible for improved hemodynamics during SNP infusion in AS with LV dysfunction.

Aortic Valve Stenosis↗