Search PubMed⌕ Search

Biomedical subjects

J W Hall

Publications and source records attributed to J W Hall.

At least 163 records · Page 9Linked to original sources

Sensory evoked responses in head injury.

Head trauma is a significant source of morbidity in the United States each year. Approximately 700 patients were admitted to our surgical intensive care unit with some degree of head trauma in a 24-month period. Glasgow Coma Score (GCS) was 8 or less in 90% of this group, and 3 or 4 in 43%. Sensory evoked responses were recorded in over 500 patients. This study is reported to demonstrate that optimum care of the injured brain depends on titration of care aimed at maintaining normal neuronal function. In our series, 25% of the patients with GCS of 3 or 4 returned home or to a rehabilitation unit, a significant decrease in morbidity over other reported series. Chemical paralysis and barbiturate coma were a factor in the decision to monitor in 50-60% of the series. In these patients, the auditory brainstem evoked response (ABR), a monitor of brainstem neuroelectrical function, and the somatosensory evoked response, a monitor of brainstem and cortical function, were used to follow the effectiveness of medical and surgical management in these patients, since neurologic examination was of limited value. Case reports are presented to demonstrate that even at high barbiturate levels, access to the integrity of the central nervous system is still possible. Relations among GCS, computerized tomography (CT), intracranial pressure (ICP), ABR, pupillary response, and outcome were studied for a subgroup of 114 patients. All of these clinical parameters, except CT findings, were significantly correlated with outcome using Chi-square analysis. When the data were further analyzed with linear regression analysis, however, the only parameters that significantly correlated with outcome were pupil reactivity and ABR. The principal conclusion of this report is that the main application of serial monitoring of the sensory central pathway in the head-injured patient is not in the prediction of outcome but in the titration of care of the patient for the preservation of neuronal function.

Adolescent↗

High-resolution CT scanning and auditory brain stem response in congenital aural atresia: patient selection and surgical correlation.

Thirty patients with congenital aural atresia underwent CT scanning and/or auditory brain stem response (ABR) testing in a 20-month period. Eighteen patients had unilateral atresia and 12 had bilateral atresia. Twelve patients subsequently had surgery for repair of their atresia. CT scanning was not electively done until the patient was at least 2 years of age, while ABR testing was often performed in the first few months of life. Nineteen patients had CT scanning and 27 had ABR testing. The CT technique was found to offer specific advantages not previously observed in other methods of radiographic evaluation: (1) the course of the facial nerve was more easily traced and (2) the presence (or absence) of a stapes was more easily noted. The ABR was measured for monaural air-conduction as well as mastoid-placement bone conduction click stimuli; simultaneous multielectrode two- or four-channel recordings were employed. With this measuring technique it was not only possible to enhance wave I detection but, more important, the laterality of ABR wave I could be noted.

Acoustic Stimulation↗

The binaural masking level difference as a function of frequency, masker level and masking bandwidth in normal-hearing and hearing-impaired listeners.

Binaural masking level differences (MLDs) were measured for 10 normal-hearing and 10 cochlear-impaired listeners, at 500 and 2 000 Hz. Maskers were either wide-band (approximately 2 000 Hz), or narrow-band (50 Hz). For wide-band maskers the noise pressure spectrum level was 50 dB/Hz, and for the narrow-band maskers the noise levels were 50 and 60 dB/Hz. At 500 Hz the hearing-impaired listeners show abnormally low MLDs in wide-band noise, but not in narrow-band noise. At 2 000 Hz, the hearing-impaired subjects show abnormally low MLDs only in narrow-band noise at the 50 dB/Hz level. The clinical implications of the results are considered.

Auditory Perception↗

Factors influencing the masking level difference in cochlear hearing-impaired and normal-hearing listeners.

The masking level difference (MLD) at 500 Hz was examined in wide-band (960 Hz) and narrow-band (50 Hz) noise for normal-hearing subjects and subjects with symmetrical mild-to-moderate cochlear hearing loss. Monaural tasks of intensity discrimination, temporal resolution, and frequency resolution were performed in order to examine relationships between monaural dysfunction and MLD performance. Interaural time discrimination for a 500-Hz pure tone also was examined. The performance of the hearing-impaired subjects was poorer than that of the normal-hearing subjects for MLD, interaural delta t, and most monaural tasks. However, no significant relationships were found between monaural and MLD performance when effects of threshold were taken into account. MLDs were more reduced in wide-band noise than in narrow-band noise for the hearing-impaired subjects (when contrasted with normal-hearing subjects). MLD performance was correlated with interaural time discrimination, and it is suggested that one reason for poor MLD performance with hearing impairment may be poor temporal coding of stimulus-fine structure.

Adult↗

Stimulus duration and frequency discrimination for normal-hearing and hearing-impaired subjects.

Frequency discrimination for 500- and 2000-Hz pure tones at durations of 5, 10, 20, 50, and 200 ms was determined for 10 normal-hearing and 10 cochlear-impaired listeners. Listeners from both groups demonstrated monotonic increases in frequency difference limens as stimulus duration decreased. The functions of the hearing-impaired listeners were parallel to those of the normal-hearing listeners for stimulus durations between 10 and 200 ms, but the overall performance of the hearing-impaired group was poorer than that of the normal-hearing group. The functions of many of the cochlear-impaired subjects were less steep than normal for the shortest durations tested (between 5 and 10 ms). There appeared to be no relation between temporal integration for frequency discrimination and temporal integration for detection threshold. The results are discussed in terms of processes of temporal integration and frequency selectivity.

Adult↗

Detection in noise by spectro-temporal pattern analysis.

Detectability of a 400-ms, 1000-Hz pure-tone signal was examined in bandlimited noise where different spectral regions were given similar waveform envelope characteristics. As expected, in random noise the threshold increased as the noise bandwidth was increased up to a critical bandwidth, but remained constant for further increases in bandwidth. In the noise with envelope coherence however, threshold decreased when the noise bandwidth was made wider than the critical bandwidth. The improvement in detectability was attributed to a process by which energy outside the critical band is used to help differentiate signal from masking noise, provided that the waveform envelope characteristics of the noise inside and outside the critical band are similar. With flanking coherent noise bands either lower or higher in frequency than a noise band centered on the signal, it was next determined that the frequency relation and remoteness of the coherent noise did not particularly influence the magnitude of the unmasking effect. An interpretation in terms of nonsimultaneous masking was reconciled with some aspects of the data, and with an interpretation in terms of across-frequency temporal pattern analysis. This paradigm, in which detection is based upon across-frequency temporal envelope coherence, was termed "comodulation masking release." Comodulation offers a controlled way to investigate some of the mechanisms which permit signals to be detected at adverse signal-to-noise ratios.

Auditory Threshold↗

The role of monaural frequency selectivity in binaural analysis.

The relation between the monaural critical band and binaural analysis was examined using an NoSm MLD paradigm, in order to resolve ambiguities about the width of the masking spectrum important for binaural detection. A 500-Hz pure-tone signal was presented with a 600-Hz-wide band of masking noise to the signal ear. Bands of noise ranging in width from 25 to 600 Hz, or noise notches (imposed on a 600-Hz-wide band centered on the signal frequency) ranging in width from 0 to 600 Hz were presented to the nonsignal ear. All noise bands and notches were centered on 500 Hz, the frequency of the signal. The effects of varying bandwidth were radically different from those of varying notchwidth: the MLD changed from zero to approximately 8 dB over a bandwidth range of 400 Hz; for notchwidths, however, the MLD changed 8 dB over a range of only 50 Hz. The results support an interpretation that the fine frequency selectivity of monaural analysis is preserved in peripheral binaural interaction, but that a relatively wide frequency range of critical bands is scanned at a later stage of binaural processing. It was suggested that the wide spectral range of binaural analysis may provide a background against which binaural differences due to the signal are detected.

Attention↗

Auditory filter asymmetry in the hearing impaired.

Thresholds for 2-kHz sinusoidal signals were determined in the presence of a notched-noise masker, for six normal-hearing listeners and 12 listeners with cochlear hearing losses. Following Patterson and Nimmo Smith [J. Acoust. Soc. Am. 67, 229-245 (1980)], conditions were used where the notch was placed both symmetrically and asymmetrically about the signal frequency. The auditory filter shape for both the low- and high-frequency side of the filter was calculated using the rounded-exponential form of the filter. In six hearing-impaired listeners, the auditory filter shape showed a shallow low-frequency skirt indicating pronounced susceptibility to the upward spread of masking. In two hearing-impaired listeners, the filter shape showed a shallow high-frequency skirt, indicating pronounced susceptibility to the downward spread of masking. Two other listeners with mild threshold losses had steeper and more symmetric filters than normal, suggesting either a small conductive loss or an attenuation factor of sensorineural origin not associated with a degradation of frequency resolution. In the remaining two listeners, the auditory filter had too little selectivity for its shape to be reliably determined.

Adult↗

NoSo and NoS pi thresholds as a function of masker level for narrow-band and wideband masking noise.

NoSo and NoS pi thresholds for a 500-Hz signal were determined as a function of masker level for masking noises having 600- and 50-Hz bandwidths centered on 500 Hz. Noise levels of 0, 10, 20, 30, 40, 50, and 60 dB/Hz were used for the 600-Hz bandwidth, and noise levels of 0, 10, 20, 30, 40, 50, 60, and 70 dB/Hz were used for the 50-Hz bandwidth. The So thresholds increased as a function of increasing noise level with a slope close to 1.0, for both the 50- and 600-Hz masker bandwidths. For the 600-Hz-wide masker, the S pi thresholds increased with a slope less than 1.0 for masker levels from 0 dB/Hz to approximately 20 dB/Hz, but increased with a slope close to 1.0 for masker levels above approximately 20 dB/Hz. For the 50-Hz-wide masker, the S pi thresholds increased with a slope less than 1.0 for masker levels from 0 dB/Hz to approximately 40 dB/Hz, but increased with a slope close to 1.0 for masker levels above approximately 40 dB/Hz. The results are discussed in terms of different binaural processes involving interaction between monaural critical bands centered on the signal frequency, and interaction involving monaural critical bands outside the monaural critical band centered on the signal. It was suggested that the narrow-band noise results are probably more appropriate than the wideband noise results when considering binaural interaction involving monaural critical bands centered on the signal frequency.

Auditory Threshold↗

Neuro-otologic applications of simultaneous multi-channel auditory evoked response recordings.

Multichannel auditory brain stem response (ABR) recordings were obtained in 75 acute, severely brain injured patients. The purpose of the study was to assess, in patients with varied neuro-otologic pathology, the clinical feasibility and value of measuring the ABR simultaneously with more than one electrode array. The use of alternative electrode arrays, in addition to the conventional (vertex to stimulus ipsilateral ear) array, augmented confident identification of wave components I through VI, and was particularly useful in patients with marked middle ear pathology which confounded ABR interpretation. The ABR recorded with an indifferent (noncephalic) reference electrode, e.g., was characterized by increased Wave V amplitude, and improved definition of Wave IV vs. V. Case studies are presented to illustrate neuro-otologic applications of the multichannel recording technique.

Adolescent↗

Frequency judgment accuracy as a function of age and school achievement (learning disabled versus non-learning-disabled) patterns.

The accuracy of children's judgments of relative situational frequency was examined in two experiments. In Experiment 1 children with normal achievement in Grades 2 and 3 were compared with such children in Grades K and 5, as well as with three groups of low-achieving children in Grades 2 and 3. These latter groups consisted of children low in reading achievement, those low in math achievement, and those identified as learning disabled. Frequency judgment accuracy increased from kindergarten to Grades 2 and 3. No other comparisons yielded significant differences. Experiment 2 confirmed both the above age difference and the absence of any frequency judgment deficiency on the part of the low-achieving groups.

Achievement↗

Monaural and binaural auditory frequency resolution measured using bandlimited noise and notched-noise masking.

Several studies using bandlimited masking noise have indicated that NOSO frequency resolution is better than that for NOS pi. The present study examined NOSO and NOS pi frequency resolution with two different masking methods: bandlimited noise and notched noise. Noise spectrum levels of 10, 30, and 50 dB/Hz were used. Thresholds were determined for a 500-Hz signal, using a three-alternative forced-choice adaptive procedure, as a function of masker bandwidth and notchwidth. For NOSO presentation, 3-dB down points were comparable for the notched-noise and bandlimiting methods. For NOS pi presentation, 3-dB down points were generally greater for the bandlimiting method than the notched noise method. Furthermore, for NOS pi presentation, the 3-dB down estimate increased as noise level increased for the bandlimiting method, but stayed constant for the notched-noise method. It is suggested that the two masking methods measured different aspects of binaural processing.

Acoustic Stimulation↗

The effect of random intensity fluctuation on monaural and binaural detection.

Two experiments were performed to determine the effects of random intensity fluctuation on NoSo and NoS pi performance. Noise was used as both signal and masker, and stimuli were bands of noise from either 0-2.0 or 2.0-4.0kHz. Signal and masker were either coherent (from the same source) or noncoherent (from independent sources). In the first experiment, noise fluctuation was achieved by modulating a wide band of noise. In the second experiment, fluctuation was achieved by narrowing the noise bandwidth. Results from both experiments indicated that NoSo performance was adversely affected by fluctuation and by noncoherent relation between signal and masker. NoS pi detection was not adversely affected by fluctuation at low frequency, and was affected less adversely than was NoSo detection at high frequency. This difference between NoSo and NoS pi performance is an important consideration when making inferences about monaural and binaural processing when the stimuli are fluctuating rather than temporally steady.

Adult↗

Temporal integration, frequency resolution, and off-frequency listening in normal-hearing and cochlear-impaired listeners.

Temporal integration for a 1000-Hz signal was determined for normal-hearing and cochlear hearing-impaired listeners in quiet and in masking noise of variable bandwidth. Critical ratio and 3-dB critical band measures of frequency resolution were derived from the masking data. Temporal integration for the normal-hearing listeners was markedly reduced in narrow-band noise, when contrasted with temporal integration in quiet or in wideband noise. The effect of noise bandwidth on temporal integration was smaller for the hearing-impaired group. Hearing-impaired subjects showed both reduced temporal integration and reduced frequency resolution for the 200-ms signal. However, a direct relation between temporal integration and frequency resolution was not indicated. Frequency resolution for the normal-hearing listeners did not differ from that of the hearing-impaired listeners for the 20-ms signal. It was suggested that some of the frequency resolution and temporal integration differences between normal-hearing and hearing-impaired listeners could be accounted for by off-frequency listening.

Adult↗

Auditory evoked responses, impedance measures, and diagnostic speech audiometry in severe head injury.

Three case studies are presented to illustrate the clinical usefulness of serial electrophysiologic and behavioral audiologic assessments in describing CNS function in severe head injury. There was an association among acute auditory brain stem and middle-latency evoked response findings, computed tomography of brain abnormality and neurologic status, and rate of recovery. Auditory evoked response findings 4 days after injury were also correlated with long-term outcome of diagnostic speech audiometry.

Acoustic Impedance Tests↗

Monaural and binaural intensity discrimination in normal and cochlear-impaired listeners.

Monaural and binaural intensity difference limens for 75-dB SPL pure tones were determined for 6 normal subjects and for 6 subjects with cochlear hearing loss. The magnitude of binaural masking level difference (BMLD) was also determined. Both normal and hearing-impaired subjects showed a 0.45-dB binaural advantage for intensity discrimination. In contrast, the BMLD was appreciably reduced with hearing impairment. Results are discussed in terms of specific effects of hearing loss on binaural hearing.

Adult↗

Rumen conditions that predispose cattle to pasture bloat.

Rumen contents from the dorsal sac were examined before alfalfa ingestion to determine factors that predispose cattle to pasture bloat. Chlorophyll concentration, buoyancy of particulate matter, and rates of gas production were significantly higher in cattle that subsequently bloated than in those that did not. Higher chlorophyll in bloat cases indicated accumulation of suspended chloroplast particles in the dorsal sac, perhaps due to increased buoyancy of the particulate matter. The higher fermentation rates (in the presence of glucose) suggested that the latent capacity for gas production was due to microbial colonization of suspended feed particles. Chlorophyll 4 h after feeding was also higher in bloated as compared to unbloated animals. In short, the microbial colonization and retention of particulate matter provided active inocula for promoting rapid legume digestion. Consequently, gas production was enhanced when feeding commenced, but the fermentation gases were trapped by the buoyant, frothy ingesta, resulting in the condition of pasture bloat.

Animals↗

Weight and age at calving and weight change related to first lactation milk yield.

Daily milk yields from 400 first lactations collected from one herd over 16 yr were utilized to ascertain relations of weight and age at calving and change of body weight during first lactation on milk yield and calving interval. These relationships were evaluated for the complete lactation and for each of five 60-day segments of the lactation. The influence of sire on the interrelationship between body weight, age at calving, and milk yield also were measured in data from sires with 10 or more daughters. Average milk yield (300 day) and gain of body weight during first lactation for all records were 5544 and 56.2 kg. Both year and season of calving influenced weight at calving, milk yield, and the relationship between the two. Milk yield was the greatest and body weight gain the least for heifers calving in the fall. Analysis of all records revealed that calving weight but not calving age accounted for a significant portion of variation of milk yield during the first four 60-day periods. Both calving weight and age accounted for a significant amount of the variation of total milk yield. There was a significant effect of sire on calving weight and milk yield but not on total weight gain, age at calving, number of services, or calving interval. There was an increase of number of services and a trend toward a longer calving interval with increasing milk yield. Although age and weight at calving were nearly equal for explaining variation of total yield of milk of first lactation, age at calving was of little value in explaining variation of milk yield of the 60-day intervals. The relationship of these observations to the use of age correction factors for extended first lactation records is discussed.

Age Factors↗