Search PubMed⌕ Search

Biomedical subjects

J W Hall

Publications and source records attributed to J W Hall.

At least 181 records · Page 10Linked to original sources

Accuracy of hearing prediction by the acoustic reflex.

Seven methods of hearing loss prediction from acoustic reflex data were compared in 225 adult subjects. The prediction methods were two versions of Sensitivity Prediction by the Acoustic Reflex (SPAR), four regression equations and a bivariate plot technique. Accuracy of hearing prediction varied significantly among methods. Hearing loss was identified most accurately with the bivariate plot technique. One SPAR version best categorized degree of hearing loss. With two of the regression equations, predicted hearing threshold level (HTL) was within +/- 15 dB of actual HTL in two-thirds of the subjects. When hearing level was categorized, all methods produced a sizeable proportion of predictive errors (29 to 48%). Serious errors, however, were uncommon.

Adolescent↗

Change in the pitch of a complex tone following its association with a second complex tone.

The pitch of a high-frequency complex stimulus was changed and maintained in the direction of the pitch of a low-frequency complex stimulus with which it was associated. Six observers made pitch matches for a pitch-shift stimulus (1250-1450-1650 Hz) before and after simultaneous presentation of this stimulus with the first through fifth harmonics of 200 Hz (200-400-600-800-1000 Hz). Data were collected for each observer on five consecutive days and one week following the fifth day. The experimental phases each day were (1) ten matches, (2) simultaneous stimuli followed by ten matches, and (3) simultaneous stimuli followed by ten matches. Association periods for simultaneous stimuli were 5 min in duration and a 5-min rest period separated the association and matching periods. The result indicated that the pitch of the pitch-shift stimulus continued to change significantly for days one through four, from an initial pitch match near 210 Hz to a final match near 205 Hz. The post one-week pitch match was also significantly lower than the initial pitch match. The pitch changes are discussed in terms of a pitch learning hypothesis.

Acoustic Stimulation↗

Transient complex and pure tone pitch changes by adaptation.

The effect of pitch adaptation by a complex stimulus was examined in two experiments. In experiment 1, a monaural complex tone pitch change was measured after ipsilateral or contralateral complex stimulus adaptation. While ipsilateral adaptation resulted in pitch changes away from the pitch of the adapting stimulus, no pitch occurred for contralateral adaptation. The precision of pitch matching was reduced by both ipsilateral and contralateral adaptation. Experiment 2 examined whether the complex tone pitch changes in experiment 1 could be accounted for by pitch changes induced in the pure tone components. Results indicated that changes induced in the pure tone components were too small to account for the complex tone shift magnitudes found in experiment 1. These results support a degree of independence of complex tone pitch from the pitches of the pure tone components. Results also supported pitch extractor specialization for a particular ear of stimulus presentation.

Adaptation, Physiological↗

Acoustic reflex amplitude. II. Effect of age-related auditory dysfunction.

Crossed and uncrossed acoustic reflex amplitude was measured in 99 adult subjects. Minor middle ear dysfunction profoundly influenced acoustic reflex amplitude. Reflex amplitude in subjects with minor impedance abnormality was, on the average, decreased by 68% in comparison to a matched control group. There was a complex relationship among age, sensorineural hearing loss, signal bandwidth and acoustic reflex amplitude. Sensorineural hearing loss differentially influenced acoustic reflex amplitude for young versus older subjects.

Acoustic Impedance Tests↗

Identification of serious hearing loss with acoustic reflex data. Clinical experience with some new guidelines.

The acoustic stapedial reflex was activated by a broad-band noise signal for 326 adult subjects. Two groups were formed on the basis of pure-tone audiometry findings. Two hundred and four subjects were normal hearers or showed, at most, a mild hearing loss with a pure-tone average (500, 1000, 2000, and 4000 Hz) of less than 35 dB HL. One hundred and twenty-two subjects showed a serious hearing sensitivity impairment with a pure-tone average of 35 dB HL or greater. These acoustic reflex data were then applied prospectively in the identification of hearing impairment. Hearing sensitivity status was accurately differentiated in over three-fourths of the population. Serious hearing loss was invariably found for subjects with acoustic reflex threshold levels equal to or greater than 110 dB SPL, whereas it was effectively ruled-out by acoustic reflex thresholds in the 60 through 80 dB SPL range. The proportion of subjects with clinically significant hearing impairment is described for intermediate acoustic reflex threshold levels. These guidelines are offered as a feasible first step in clinical differentiation of hearing sensitivity status.

Adult↗

Forms of binaural summation and the implications of individual variability for binaural hearing aids.

The advantages which a two-ear system has over a one-ear system appear to be manifold, but not all understood in detail. All probably play some role in the generally recognised advantage of binaural aids in offsetting auditory disabilities. Several possible forms of binaural summation are distinguished here and their possible role discussed. Experimental results with normally-hearing listeners and with aid users show that binaural summation is likely to lead to gain settings of about 6 dB lower than with otherwise equivalent monaural amplification. In some cases this may be a direct cause of benefit. However individuals differ systematically in the extent to which they show this effect, which may be relevant to prognosis for binaural aiding. Evidence is reported of an association between binaural summation and binaural advantage. Individuals also differ systematically in binaural summation for uncomfortable loudness level.

Auditory Perception↗

Hearing loss prediction by the acoustic reflex in a young population: comparison of seven methods.

Seven methods of hearing loss prediction by the acoustic reflex were compared in 869 subjects, aged 1 to 20 years. The seven methods were two versions of Sensitivity Prediction by Acoustic Reflex (SPAR), four regression equations, and a bivariate plot technique. While accuracy rate for each of the seven methods generally exceeded 64%, hearing loss was most accurately identified by the bivariate plot system. The proportions of predictive errors among methods, however, ranged from 22 to 31%; moderate errors predominated while severe predictive errors were rare. Accuracy of hearing loss prediction was not significantly affected by chronologic age. However, all methods produced a substantial (31-67%) proportion of predictive errors in patients with minor, clinically insignificant, tympanometric abnormalities. In children with normal impedance findings, the methods permit reasonably accurate identification of hearing loss, categorization of degree of loss, or prediction of hearing loss in dB.

Acoustic Impedance Tests↗

Pitch and timbre in a two-tone dichotic auditory illusion.

The Deutsch paradigm that produces an auditory illusion with dichotic alternating 400 and 800 Hz tones [D. Deutsch, J. Acoust, Soc. Am. 55, 518--519, (1974a)] was modified to clarify aspects of pitch and timbre. The 400-Hz sinusoid was replaced by a high-frequency complex tone (1000--1200--1400 Hz) whose residue pitch was perceived as the low stimulus. Significant results based on the response of 21 subjects indicated that the illusion is pitch-, and not frequency-, based. The effect of timbre was found to be negligible.

Acoustic Stimulation↗

Pitch for nonsimultaneous successive harmonics in quiet and noise.

Pitch perception was studied with respect to nonsimultaneous successive harmonics of fundamentals in quiet and noise. Stimuli consisted of three nonoverlapping sine waves each of 40-msec duration. Pitch perception, examined by discrimination and matching, was found to correspond to spectral frequency in quiet and fundamental frequency in noise. The results suggest a pitch processor that integrates over time (synthetic mode) in noise and analyzes spectral components (analytic mode) in quiet. The findings are discussed with respect to current theories of pitch perception and auditory integrative functions. The findings are thought to be particularly relevant to analytic and synthetic modes of pitch perception.

Acoustics↗

Effects of age and sex on static compliance.

The effects of age and sex on static compliance values were analyzed in 336 patients. Static compliance of the normal middle ear varies as a function of age and sex. In men and women, static compliance values are maximum between 31 and 40 years of age, and then decrease relatively systematically with increasing age. Under 30 years of age, static compliance values are slightly greater in female subjects. From 30 to 60 years of age, men show substantially greater static compliance measurements. Above 60 years of age, static compliance is comparable for both sexes. Comparison of normal vs otosclerotic ears showed that the age effect considerably reduces the clinical usefulness of the static compliance measure. The overall findings of this study support the concept of decreased compliance of the middle ear system with increasing age.

Acoustic Impedance Tests↗