Search PubMed⌕ Search

Biomedical subjects

J Reinartz

Publications and source records attributed to J Reinartz.

44 records · Page 3Linked to original sources

Pull-out strength of Caspar cervical screws.

Anterior cervical instrumentation as an adjunct to bone fusion has an important role in cervical spine surgery. Posterior vertebral body cortex purchase is strongly recommended in the use of the Caspar system, although few biomechanical data exist to validate this requirement. In this study, Caspar screws were placed in 43 human cadaveric cervical vertebral bodies, either putting them into the posterior vertebral cortex as identified radiographically or penetrating it by 2 mm as recommended in the literature. Pull-out tests were conducted with tension applied to a connected plate at 0.25 mm/s, and force-deformation data were obtained. Failure typically occurred with clean pull-out; in most instances, cancellous bone remained attached to screw threads. Mean load without posterior cortical purchase was 375 +/- 53 N; with penetration it was 411 +/- 70 N. These differences were nonsignificant. Average deformation to failure was 1.41 +/- 0.10 mm in the group without posterior cortical penetration. In the posterior penetration group, mean deformation was 1.56 +/- 0.16 mm. Again, differences were not significant. Posterior cortical penetration does not improve the pull-out strength of Caspar screws in an isolated vertebral body model, but other biomechanical studies need to be done before insertion methods are altered.

Biomechanical Phenomena↗

Strength and kinematic response of dynamic cervical spine injuries.

This study was conducted to evaluate the biodynamic strength and localized kinematic response of the human cervical spine under axial loading applied to the head. Intact ligamentous fresh human cadaveric head-neck complexes were subjected to dynamic compressive forces with a custom-designed electrohydraulic testing device at varying rates. The structure included the effects of anterior and posterior cervical spine muscles with a system of pulleys, dead weights, and spring tension. Localized kinematic data were obtained from retroreflective targets placed on the bony landmarks of the specimen at every level of the spinal column. Input forces, accelerations, displacement, and output generalized force histories were recorded as a function of time with a digital data acquisition system at dynamic sampling rates in excess of 8,000 Hz. High-speed photography at 1,000-1,200 frames/sec also was used. Pathologic alterations to the head-neck complex were evaluated with conventional radiography, computed tomography, and cryomicrotomy. In all specimens, cervical spine injuries occurred as a result of impact. Compressive forces recorded at the distal end of the preparation indicated large-duration, short-magnitude pulses in contrast to short-duration, high-amplitude input waveforms at the head, suggesting decoupling characteristics of the head-neck system. Cervical vertebral body accelerations were consistently smaller than the accelerations recorded on the head. Kinematic data demonstrated temporal deformation characteristics as well as a plausible sequence of spinal deformations leading to injury, which were correlated with the pathoanatomic alterations documented with the post-test computed tomographic and sequential cryomicrotome sections.

Acceleration↗

Activation of the plasminogen activator system in a keratinocyte cell line (HaCaT) by alkyl sulfates.

A human keratinocyte cell line (HaCaT) was analysed for plasminogen activator activity. By immuno-capture and immuno-inhibition studies we obtained evidence that HaCaT cells synthesize and secrete urokinase-type plasminogen activator (uPA) and tissue-type PA (tPA). Zymographic analysis by using fibrin agar indicator gels indicated that part of the PA activity in culture supernatants of the HaCaT line is complexed with putative PA inhibitors (PAI). Alkyl sulfates of different chain length were found to have a strong stimulatory effect on PA activity in HaCaT culture supernatants. Our findings are discussed in view of the known skin-irritating effects of alkyl sulfates in vivo.

Cell Line↗

Biomechanics of lumbar pedicle screw/plate fixation in trauma.

This investigation was conducted to determine alterations in the biomechanical strength and stiffness characteristics of the lumbar spine fixated with Steffee instrumentation. Comparative studies of these parameters were conducted using seven lumbar columns from fresh human cadavers. Three runs were conducted on each T12-L5 column: control, injured, and fixated. The specimens were loaded under the compression-flexion mode until failure (control run) and then reloaded (injury run) to the failure deformation determined in the control run. Screw/plates were then inserted one level proximal and distal to injury, and the specimens were reloaded (fixation run). Radiographs were taken before and after each trial. Data on deformation and force histories were gathered. The load-deflection response of the injured and fixated specimens were bimodal with two representative stiffnesses. Control failure loads and stiffnesses were higher than those for the injured (P less than 0.001) or fixated (P less than 0.01) spine. Initial stiffness was significantly higher for the fixated than for injured columns (P less than 0.001), but the final stiffnesses were similar. The increase in the initial stiffness in the fixated specimen compared to the injured specimen indicates the strength added to the posterior region of the spine. The relatively smaller alteration in the final stiffness between the fixated and the injured columns, corresponding to the load shared by the anterior column, may suggest that, above a critical strain level, the anterior column absorbs a higher portion of the external load and posterior fixation may be inadequate as sole treatment in trauma.

Adult↗

Injury biomechanics of the human cervical column.

In this study, the authors have developed a technique to replicate clinically relevant traumatic cervical spine injuries and determined the injury biomechanics. Because of the importance of compressive forces in neck injuries, this research was conducted using compression as the primary load vector. Six fresh human cadaveric head-neck complexes were prepared by fixing the distal end in methylmethacrylate. Tests were done with varying loading rates to include quasistatic and dynamic conditions. For quasistatic experiments, the proximal end was fixed to the piston of the testing device. In dynamic tests, the cranium was unconstrained, and to maintain stability, the effects of the spinal musculature were simulated by means of pulleys, deadweights, and springs in the anterior and posterior parts of the head-neck complex. Quasistatic tests conducted at a rate of 2.0 mm/sec produced cervical spine trauma at forces ranging from 1.7 to 2.3 kN, with deformations ranging from 2.2 to 3.7 cm. The specimens were deep-frozen at the level of injury, preserving the local deformation of the tissues to enable a detailed evaluation immediately after the injury. Dynamic tests conducted at velocities of 3.2 to 5.7 m/sec resulted in impact injuries at one level of the head-neck complex. The applied forces at the vertex were considerably higher than those recorded at the distal end. The failure deformations for both the quasistatic (2.2-3.7 cm) and dynamic (1.7-3.2 cm) tests, however, were found to be similar, suggesting that the human head-neck complex is a deformation-sensitive structure.

Aged↗

Effect of axial loading on neural foramina and nerve roots in the lumbar spine.

The hypothesis that the neural foramina in some patients are critically narrowed by axial compression of the spine has not been studied with direct imaging techniques. Frozen cadaveric motion segments of the lumbar spine (intervertebral disk and contiguous vertebrae) were imaged with computed tomography (CT). The segments were thawed and compressed in a hydrostatic press to simulate axial loading, and then the segments were frozen and imaged again. The motion segments were subsequently sectioned with a cryomicrotome, and the chronic degenerative changes present in the disks were classified. Pre- and post-compression CT images were compared, and anatomic relationships were studied. In 41 randomly selected segments (some with preexisting radial, transverse, and concentric annular tears), compression diminished the diameters and cross-sectional areas of the spinal canal and neural foramina. In no cases were nerve roots displaced, distorted, or compressed by axial loading. This study suggests that axial loading, such as that produced by ordinary weight bearing, does not critically compromise the neural foramina even in the presence of chronic degenerative disk changes.

Adult↗

Dynamic response of human cervical spine ligaments.

This study was undertaken to investigate the dynamic response of human cervical spine ligaments. Uniaxial tensile failure tests were conducted on anterior longitudinal ligament (AL) and ligamentum flavum (LF) structures. These ligaments were tested under in situ conditions by transecting all the elements except the one (AL or LF) under study. A fixture was designed to properly align the specimen to induce a uniaxial mode of loading. A six-axis load cell was placed at the distal end of the specimen. The proximal end of the specimen was attached to the piston of a specially designed electrohydraulic testing device. The biomechanical properties of the ligaments were determined at four different loading rates of 8.89, 25.0, 250.0 and 2500 mm/sec. The mechanical response indicated nonlinear and sigmoidal characteristics. The ultimate tensile failure load, stiffness, and energy-absorbing capacity at failure were found to increase with increasing loading rates for both the AL and LF. However, the distractions at failure did not indicate this tendency. While the ultimate tensile force and ultimate energy-absorbing capacity varied nonlinearly with the logarithm of the loading rate, the stiffness varied linearly.

Aged↗

Plasmin in pericellular proteolysis and cellular invasion.

Invasive tumor growth or severe inflammation is accompanied by the extravasation of fibrinogen from leaky or damaged blood vessels and the formation of a fibrin clot. The clot provides a matrix for the inward migration ('invasion,' 'infiltration') of tumor cells as well as inflammatory cells. The factors that govern the cell/fibrin interaction are not known. We have explored in vitro the possible role of the cell-surface-associated pathway of plasminogen activation in the adhesion of keratinocytes to fibrin and in the invasion of melanoma cells into fibrin gels. Our experiments provided evidence that generation of plasmin at the cell surface destabilizes the adhesive interaction between keratinocytes and fibrin, most likely by cleaving fibrin into fibrinopeptides and destroying its adhesive capacity. Moreover, we found that plasmin generated at the melanoma cell surface promotes the inward migration of these cells into three-dimensional fibrin matrices. In conclusion, the generation of plasmin at the cellular surface may be an important factor in pericellular proteolysis and the dynamic interaction between cells and fibrin-containing pericellular matrix under conditions of tumor invasion and inflammation.

Animals↗