Upper airway resistance syndrome.

This article reviews the clinical picture, diagnosis and management of the upper airway resistance syndrome (UARS). Presently, there is not enough data on key points like the frequency of UARS and the morbidity associated with this condition. Furthermore, the existence of LIARS as an independent sleep disorder and its relation with snoring and obstructive events is in debate. The diagnosis of UARS is still a controversial issue. The technical limitations of the classic approach to monitor airflow with thermistors and inductance plethysmography, as well as the lack of a precise definition of hypopnea, may have led to a misinterpretation of UARS as an independent diagnosis from the sleep apnea/hypopnea syndrome. The diagnosis of this syndrome can be missed using a conventional polysomnographic setting unless appropriate techniques are applied. The use of an esophageal balloon to monitor inspiratory effort is currently the gold standard. However, other sensitive methods such as the use of a pneumotachograph and, more recently, nasal cannula/pressure transducer systems or on-line monitoring of respiratory impedance with the forced oscillation technique may provide other interesting possibilities. Recognition and characterization of this subgroup of patients within sleep breathing disorders is important because they are symptomatic and may benefit from treatment. Management options to treat UARS comprise all those currently available for sleep apnea/hypopnea syndrome (SAHS). However, the subset of patients classically identified as LIARS that exhibit skeletal craneo-facial abnormalities might possibly obtain further benefit from maxillofacial surgery.

Journal Article↗

Evidence of the effectiveness of continuous positive airway pressure in the treatment of sleep apnea/hypopnea syndrome.

Continuous positive airway pressure (CPAP) is worldwide considered as the standard treatment of sleep apnea/hypopnea syndrome (SAHS) although studies on the effectiveness of this treatment are limited. The aim of our study was to evaluate the effectiveness of CPAP in improving SAHS-related symptoms, daytime function, perceived health status, and quality of life in patients with moderate to severe SAHS. The effect of conservative treatment (CT) measures-sleep hygiene and weight loss- was compared with CT + CPAP. We included 105 consecutive patients (13 females, age 53 +/- 10 yr, body mass index [BMI] = 32 +/- 6 kg/m2, apnea/hypopnea index [AHI] = 56 +/- 20, Epworth sleepiness scale [ESS] = 12 +/- 5) who met our criteria for CPAP treatment. Patients were randomly allocated in two groups of similar characteristics. Group 1 (n = 37) was asked to improve sleep hygiene and started a weight loss program. Group 2 (n = 68) received, in addition, treatment with CPAP. Both groups were followed through weekly telephone calls and appointments. Sleepiness, other symptoms related to SAHS, daytime function, perceived health status, and quality of life were assessed through questionnaires at inclusion and after 3 mo of treatment. The relief of sleepiness and other SAHS-related clinical symptoms and improvement in perceived health status was much greater in Group 2 receiving CT + CPAP compared with Group 1, only receiving CT. The odds of experiencing a treatment response with CPAP + CT compared with CT alone was 6.52 (odds ratio [OR] = 2.51 to 17.6, 95% confidence interval [95% CI]). CPAP is currently the treatment of choice. At this time, the indication of CPAP treatment in moderate to severe SAHS is adequately supported.

Body Mass Index↗

Clinical application of the forced oscillation technique for CPAP titration in the sleep apnea/hypopnea syndrome.

We have previously demonstrated that upper airway obstruction in sleep apnea/hypopnea syndrome (SAHS) can be accurately assessed in real-time by measuring respiratory impedance (|Z|) with the forced oscillation technique (FOT). The aims of the present study were: (1) to determine the feasibility of identifying the optimal continuous positive airway pressure (CPAP) for patients with SAHS based on analysis of the |Z| signal during conventional polysomnographic CPAP titration studies; and (2) to evaluate practical issues involved in the application of FOT during CPAP titration. We performed CPAP titration in 28 patients with SAHS during polysomnography (PSG) (14 nap and 14 full overnight studies) using a FOT system applied continuously to obtain an on-line measurement of |Z|. FOT was easily implemented and was well-tolerated by the patients. Optimal CPAP levels were determined both in the conventional manner from the standard PSG titration record and during a separate blinded analysis using the FOT signal alone. The mean conventional versus FOT-based optimal CPAP values were similar for both nap studies (10.6 +/- 0.6 [mean +/- SEM] versus 11.1 +/- 0.6 cm H(2)O, respectively, p = 0. 054) and overnight studies (9.9 +/- 0.7 versus 9.9 +/- 0.6 cm H(2)O, respectively, p = 1.00). Subsequent analysis of the PSG record with the FOT signal incorporated demonstrated that artefacts in the |Z| tracing occurred during mask leak, mouth breathing, and movement during arousal. Such abnormalities were readily identified from the flow tracing. These results indicate that, for adequate interpretation, the tracing and values of respiratory impedance obtained by FOT should be evaluated in conjunction with the flow signal. Continuous FOT-guided CPAP titration is feasible and may be a useful adjunct during manual titration. FOT could also potentially serve as the basis for automated CPAP in SAHS.

Humans↗

Importance of the pulse oximeter averaging time when measuring oxygen desaturation in sleep apnea.

The accuracy of pulse oximeters in measuring transient changes in oxygen saturation (SaO2) may be affected by the oximeter time response. The aim of this study was to assess the effect of modifying the pulse oximeter averaging time (T) on the measurement of SaO2 in patients with the sleep apnea-hypopnea syndrome (SAHS). Twelve patients with severe SAHS were studied during a nap with conventional oximeters: Ohmeda 3740 and Criticare 501. We compared the readings of each patient's oxygen desaturation measured simultaneously with two identical pulse oximeters. One oximeter was the control (T = 3 seconds), and in the other T was set from 3 seconds to 21 seconds. No significant differences in SaO2 were found when both oximeters were set to the same T (3 seconds). In contrast, increasing T to 12 seconds and 21 seconds in one of the oximeters resulted in considerable and significant differences in the measured SaO2: oxygen desaturation was underestimated by up to 60% when compared with the control. The misestimation of SaO2 induced by settings of T which are within the range selectable in conventional oximeters may be of epidemiological significance when pulse oximetry is used as a complementary diagnostic tool to classify sleep events in SAHS.

Adult↗

Assessment of airflow obstruction during CPAP by means of forced oscillation in patients with sleep apnea.

The forced oscillation technique (FOT) is a noninvasive method to measure respiratory resistance (Rrs) potentially useful for monitoring upper airway obstruction in patients with obstructive sleep apnea/hypopnea syndrome (SAHS). The aim of this work was to test the clinical suitability of FOT in assessing dynamic changes in airflow obstruction in patients with SAHS during continuous positive airway pressure (CPAP) and to investigate the CPAP dependence of Rrs. Forced oscillation (5 Hz) was applied to six male patients with SAHS submitted to CPAP titration procedure. Esophageal pressure was measured with a balloon-tipped catheter. Mid-inspiratory resistance (Rrs,i), mid-expiratory resistance (Rrs,e), and esophageal pressure swings (deltaPes) were computed for the respiratory events recorded at each CPAP level. Rrs,i decreased markedly and significantly from 36.0 +/- 4.0 cm H2O x s/L (mean +/- SEM) at baseline CPAP (4 cm H2O) to 13.1 +/- 2.8 cm H2O x s/L at optimal CPAP (11.3 +/- 0.4 cm H2O). Rrs,e showed a faster decrease with increasing CPAP reaching normal values at approximately 8 cm H2O. Rrs,i was strongly correlated (r2 = 0.94) with deltaPes. Our results suggest that FOT can be used as an alternative to the esophageal balloon for assessing airflow obstruction in patients with SAHS and for CPAP titration. Moreover, FOT allows us to detect phasic changes in resistance within the breathing cycle.

Adult↗

Flow-dependent positive airway pressure to maintain airway patency in sleep apnea-hypopnea syndrome.

Airway obstruction in patients with sleep apnea-hypopnea syndrome (SAHS) is due to increased critical pressure (Pcrit) of the upper airway. The ideal nasal pressure (Pn) to maintain airway patency should consist of the constant term to account for Pcrit and a term (Rn . V) proportional to flow (V) to account for the dynamic pressure drop through nasal resistance (R n). Continuous positive airway pressure (CPAP) applied to avoid flow limitation results in a Pn greater than required over most of the breathing cycle. The aim was to assess a flow-dependent positive airway pressure (FDPAP) based on adapting Pn to the instantaneous flow: Pn = P0 + k . V. FDPAP was tested on collapsible airway models and its applicability was assessed in nine patients with SAHS during sleep. In models, FDPAP prevented flow limitation with lower mean P n and work of breathing than CPAP. In patients FDPAP allowed the patients to breathe normally with a mean Pn (6.6 +/- 1.2 cm H2O) systematically and significantly (p < 0.05, paired t test) lower than when applying CPAP (9.1 +/- 1.2 cm H2O). The results found in models and in patients suggest that adapting the applied nasal pressure to the instantaneous breathing flow may be of potential practical interest in SAHS.

Adult↗

Accuracy of thermistors and thermocouples as flow-measuring devices for detecting hypopnoeas.

The aim of this work was to assess the accuracy of thermistors/thermocouples as devices for detecting hypopnoeas in sleep studies. Conventional thermistor/thermocouples were studied with a respiratory model allowing the simulation of inspiratory (22 degrees C) and expiratory (37 degrees C) flows. The thermistor signal (V'th) was compared with a pneumotachograph (V'th): 1) for sinusoidal and square-wave airflows (+/-0.05 to +/-0.8 L.s(-1), 10-20 breaths.min(-1) (bpm)); 2) when changing the distance from the thermistor to the nose (0-20 mm); and 3) when doubling the section of the nostrils. The thermistor was strongly nonlinear and flow reductions (hypopnoeas) were underestimated: a 50% reduction in V' (+/-0.5 L.s(-1), 15 bpm, sinusoidal) resulted in only an 18% reduction in V'th. V'th depended considerably on the airflow pattern: for V'=+/-0.5 L.s(-1), V'th increased by 100% from sinusoidal (20 bpm) to square-wave (10 bpm). For V'=+/-0.5 L.s(-1), 15 bpm, sinusoidal flow, V'th increased by 79% when the distance thermistor-nose varied from 20-0 mm, and V'th decreased by 37% when doubling the nose section. We concluded that thermistor/thermocouples are inaccurate flow-measuring devices when used at the airflow conditions typical of sleep studies. Their use for quantifying hypopnoeas may lead to considerable underdetection of these respiratory events.

Evaluation Studies as Topic↗

Nasal prongs in the detection of sleep-related disordered breathing in the sleep apnoea/hypopnoea syndrome.

Conventional systems to monitor oronasal flow in sleep studies have traditionally relied on a thermistor signal. Our study was designed to verify whether nasal prongs (NP) connected to a pressure transducer could improve respiratory events detection in patients with sleep apnoea/hypopnoea syndrome (SAHS) compared to traditional systems. Sleep episodes from a 2 h conventional polysomnographic record plus NP signal obtained at random from eight patients (age: mean(+/-SD) 53(+/-12) yrs; body mass index (BMI): 29(+/-6) kg x m(-2); apnoea/hypopnoea index (AHI): 27(+/-20) events x h(-1)) were identified and used for analysis. An abnormal change in the pattern of any of the respiratory or neurological variables occurring during the observation period was defined as an episode. Each episode was registered and scored with concomitant scoring of the remaining variables. According to the episode definition three different profiles were established: 1) periods of reduction of ventilation in either variable without an arousal or cyclical desaturation, named nonpathological episode (NPE); 2) an idiopathic or nonrespiratory arousal (IA); and 3) a true respiratory event (TRE) defined as reduction or absence of flow demonstrated by either thermistor, thoraco-abdominal bands or NP accompanied by cyclical desaturation and/or arousal. For each TRE, its detection by thermistor, thoraco-abdominal bands or NP was established. A total of 877 sleep episodes were observed (42 NPE, 30 IA and 805 TRE). When compared to single or combined thermistor and bands approach, NP had the highest respiratory events detection rate, 779 (96.8%) versus 673 events (83.6%), respectively. Detection of respiratory-related arousals was also improved by NP and only 3% could account for mouth breathing respiration. It is concluded that nasal prongs improve the detection of respiratory events in patients with sleep respiratory disorders.

Adult↗

Forced oscillation technique for the evaluation of severe sleep apnoea/hypopnoea syndrome: a pilot study.

The forced oscillation technique (FOT) is a noninvasive method of potential clinical interest for quantitatively assessing airway mechanics during sleep. We investigated the applicability of FOT as a diagnostic tool for noninvasive assessment of airflow obstruction in patients with sleep apnoea/hypopnoea syndrome (SAHS) during sleep. In seven patients previously diagnosed with severe SAHS (mean+/-SD apnoea/ hypopnoea index (AHI) 67+/-14) we performed a full polysomnography (PSG) together with on-line measurement of respiratory impedance (IZI) using FOT. For each patient we determined: 1) number of respiratory events conventionally detected by full PSG, those obtained by FOT and their degree of concordance; and 2) the characteristics and values of IZI during the respiratory events. FOT was well tolerated and easily applied in conjunction with a conventional sleep setup. The mean number of respiratory events x h(-1) detected by PSG and FOT were 55+/-16 and 58+/-17, respectively, with a strong concordance. IZI increased from a baseline of 11+/-4 to 50+/-20 cmH2O x L(-1) x s during apnoea (mean+/-SD). In all but one patient intermittent increases of IZI occurred immediately before each obstructive apnoea. In four patients, the increases of IZI developed at end-expiration whereas in two others occurred during inspiration. During hypopnoea most of the patients showed decreases of IZI during expiration. In conclusion, forced oscillation technique can be used as a noninvasive and complementary tool for the diagnosis of respiratory events and provides an on-line quantitative approach for continuous monitoring of airflow obstruction during sleep in patients with sleep apnoea/hypopnoea syndrome.

Adult↗

Analog circuit for real-time computation of respiratory mechanical impedance in sleep studies.

The aim of this work was to develop a low-cost circuit for real-time analog computation of the respiratory mechanical impedance in sleep studies. The practical performance of the circuit was tested in six patients with obstructive sleep apnea. The impedance signal provided by the analog circuit was compared with the impedance calculated simultaneously with a conventional computerized system. We concluded that the low-cost analog circuit developed could be a useful tool for facilitating the real-time assessment of airway obstruction in routine sleep studies.

Airway Resistance↗

Evaluation of nasal prongs for estimating nasal flow.

Nasal prongs (NP) connected to a pressure transducer have been suggested as a useful alternative for measuring nasal flow in sleep apnea/hypopnea patients. However, flow measured with NP is expected to be nonlinear. The aim of the present study was to analyze and correct the nonlinearity of nasal flow measurements with NP (VNP). Nasal flow was simultaneously measured with a pneumotachograph (PNT; V) and (NP; VNP) in six healthy subjects during 60 s of breathing at different tidal volumes. Nonlinearity of VNP was assessed by fitting separately, for inspiration and expiration, a Rorher-model equation (VNP x K1 x V + K2 x V2). In addition, we fitted the data to a simpler nonlinear quadratic model (P = K x V2). The main findings were: (1) an excellent fit of the Rorher equation to measured data in all cases; (2) although differences in the Rorher equation coefficients between inspiration and expiration were observed, they were not statistically significant; (3) a substantial intersubject variability was found; and finally, (4) the square root of VNP acceptably fitted the nasal flow data measured by PNT (V) in most cases. We conclude that in order to quantitatively assess nasal flow with NP, data should be corrected for their nonlinear pressure-flow relationships and, that the square root of the flow signal measured with NP is the simplest method of correcting for the observed nonlinearity.

Adult↗

Lack of evidence for diaphragmatic fatigue over the course of the night in obstructive sleep apnoea.

The aim of this study was to determine whether diaphragmatic fatigue develops over the course of the night in patients with obstructive sleep apnoea (OSA). Patients with severe OSA underwent overnight polysomnography with the addition of gastric and oesophageal catheters for measurement of transdiaphragmatic pressure (Pdi) (n = 7) and a gastro-oesophageal electrode for determination of diaphragmatic electromyogram (EMGdi) (n = 5). Analyses of Pdi and EMGdi were performed to detect fatigue during the large inspiratory efforts at the end of apnoeas in Stage 2 sleep at the beginning and end of the night. Measurements included Pdi values, shape analysis of the Pdi waveform, the relaxation rate (tau R) of Pdi, EMGdi and its relationship to Pdi, and the centroid frequency (fc) of EMGdi. End of apnoeic Pdi and EMGdi increased from the beginning to end of the night (e.g. 19 +/- 14% increase in Pdi; p < 0.05). The rate of increase in Pdi and EMGdi during apnoeas did not change. The Pdi versus EMGdi relationship was linear, and remained unchanged over the course of the night. There was no significant change in the shape of the Pdi waveform, and there were no changes in tau R from the beginning to the end of the night (0.13 +/- 0.01 s for both periods). There was also no shift in the fc of the EMGdi power spectrum (94 +/- 5 vs 93 +/- 6 Hz; NS), and no change in the relationship of fc to Pdi or EMGdi from the beginning to the end of the night. These findings do not support the development of diaphragmatic fatigue over the course of the night in obstructive sleep apnoea.

Catheterization↗

A system to generate simultaneous forced oscillation and continuous positive airway pressure.

Assessment of airway obstruction in patients with obstructive sleep apnoea (OSA) subjected to continuous positive airway pressure (CPAP) may be carried out using the forced oscillation technique (FOT). To facilitate routine application of forced oscillation (FO) in sleep studies, our aim was to design a system capable of generating CPAP and applying FOT simultaneously. We constructed a prototype CPAP + FO generator by connecting a specially designed electromagnetic valve in parallel with a conventional blower. The capacity of the prototype to generate forced oscillation (5 Hz +/- 1 hPa) was tested by connecting it to a model simulating spontaneous breathing. The response of the prototype for target CPAPs of 5, 10 and 15 hPa and imposed sinusoidal breathing with peak flow up to 0.75 L x s(-1) was excellent when compared with that reported for commercially available CPAP generators. The applicability of the prototype was tested by applying it to assess airway obstruction in four patients with OSA during sleep. We conclude that the generator designed is able to apply continuous positive airway pressure and forced oscillation simultaneously. The system could be useful for automatic and noninvasive assessment of airway obstruction in patients with obstructive sleep apnoea subjected to continuous positive airway pressure. Future development of the generator may be helpful in implementing a set-up for automatic titration of continuous positive airway pressure.

Airway Resistance↗

Should patients with sleep apnoea/hypopnoea syndrome be diagnosed and managed on the basis of home sleep studies?

The purpose of this study was to analyse the validity and the economic efficiency of a portable monitor of respiratory parameters (PMRP), used in a home setting for the diagnosis of sleep apnoea/hypopnoea syndrome (SAHS). Eighty nine patients with suspected SAHS were studied in two settings: in the sleep laboratory using full-polysomnography (full-PSG); and at the patient's home using a PMRP. In the home setting, 50 patients were assisted by a technician and 39 set up the equipment themselves. SAHS (apnoea/hypopnoea index (AHI) >10 events x h(-1) by means of full-PSG) was diagnosed in 75 of the 89 patients. An acceptable agreement was obtained between the AHI measured by full-PSG and PMRP, according to the Bland and Altman method of concordance (mean bias 2.56; 95% confidence interval 3.25). Sensitivity and specificity of PMRP were adequate for diagnostic purposes; however, their values rely on the prior PMRP-AHI cut-off point selected with reference to full-PSG-AHI >10. The clinical therapeutic decision taken after PMRP agreed with that taken with full-PSG in 79 patients (89%). Although 10% of the studies with an individual set-up needed repetition, both of the domiciliary modalities (with and without a technician's intervention) were, economically, about three times more efficient than full-PSG. In conclusion, we believe that patients with a suspected sleep apnoea/hypopnoea syndrome should initially be studied in a home setting with a portable monitor of respiratory parameters, since it is a reliable method with an acceptable cost-effective profile.

Adult↗

[Obstructive apnea syndrome during sleep secondary to a pharyngeal lymphoma. Improvement with continuous pressure treatment of the upper airway].

Obstructive sleep apnea syndrome (OSAS) is characterized by multiple episodes of upper airway (UA) obstruction during sleep. Patients experience daytime hypersomnia, sluggishness and inability to concentrate; snoring at night is common. We report the case of a man with Hodgkin's lymphoma without full remission and with pharyngeal recidivism leading to OSAS. He experienced marked diurnal hypersomnia accompanied by behavior disorders. Examination revealed flow-volume OSAS, suggesting UA instability. Cervical computed tomography showed a prevertebral lymphomatous mass in the pharynx causing significant UA compression. UA size increased considerably after use of continuous positive airway pressure (CPAP), which normalized sleep and produced significant relief of symptoms. Later, after chemotherapy, OSAS resolved and the patient was able to abandon CPAP treatment.

Hodgkin Disease↗

Relationship of peak exercise capacity with indexes of peripheral muscle vasodilation.

Since leg muscles receive the majority of cardiac output and consume a large proportion of total oxygen consumption (VO2) during cycle exercise, maximum leg blood flow may be an important determinant of peak VO2 (VO2peak). We investigated the relationships between parameters of active hyperemia after thigh tourniquet occlusion (alone or with calf exercise) with whole body peak exercise capacity during maximum cycle exercise. Twenty-one healthy male subjects, aged 19-39 yr. performed maximum incremental cycle exercise. Calf blood flow, conductance (blood flow/mean blood pressure), vasodilatory capacity (peak/baseline conductance), and duration of vasodilation were then determined with venous occlusive plethysmography under two conditions: 1) after thigh tourniquet occlusion for 10 min; 2) after ischemic calf exercise (thigh tourniquet occlusion with calf exercise to exhaustion). Group mean VO2peak was 120 +/- 35% (standard deviation) predicted. There was a significant relationship between VO2peak/ lean body mass and peak calf conductance after maximum ischemic calf exercise (r = 0.556; P < 0.01). However, VO2peak/lean body mass was more closely correlated with the duration of vasodilation after thigh tourniquet occlusion with ischemic calf exercise (r = 0.861; P < 0.001). These results suggest that the duration of calf vasodilation after maximal ischemic calf exercise appears to be a better index of cycle exercise capacity in healthy subjects.

Adult↗