Search PubMed⌕ Search

Biomedical subjects

J M Montserrat

Publications and source records attributed to J M Montserrat.

At least 19 recordsLinked to original sources

Performance of mechanical ventilators at the patient's home: a multicentre quality control study.

BACKGROUND: Quality control procedures vary considerably among the providers of equipment for home mechanical ventilation (HMV). METHODS: A multicentre quality control survey of HMV was performed at the home of 300 patients included in the HMV programmes of four hospitals in Barcelona. It consisted of three steps: (1) the prescribed ventilation settings, the actual settings in the ventilator control panel, and the actual performance of the ventilator measured at home were compared; (2) the different ventilator alarms were tested; and (3) the effect of differences between the prescribed settings and the actual performance of the ventilator on non-programmed readmissions of the patient was determined. RESULTS: Considerable differences were found between actual, set, and prescribed values of ventilator variables; these differences were similar in volume and pressure preset ventilators. The percentage of patients with a discrepancy between the prescribed and actual measured main ventilator variable (minute ventilation or inspiratory pressure) of more than 20% and 30% was 13% and 4%, respectively. The number of ventilators with built in alarms for power off, disconnection, or obstruction was 225, 280 and 157, respectively. These alarms did not work in two (0.9%), 52 (18.6%) and eight (5.1%) ventilators, respectively. The number of non-programmed hospital readmissions in the year before the study did not correlate with the index of ventilator error. CONCLUSIONS: This study illustrates the current limitations of the quality control of HMV and suggests that improvements should be made to ensure adequate ventilator settings and correct ventilator performance and ventilator alarm operation.

Analysis of Variance↗

Sleep-related breathing disorders: impact on mortality of cerebrovascular disease.

The aim of the study was to analyse the impact of sleep-related breathing disorders in a 2-yr survival follow-up of patients with a first ever stroke or transient ischaemic attack. The study followed 161 patients. Complete neurological assessment was performed in order to determine cerebrovascular risk factors, functional disability, and parenchymatous and vascular localisation, as well as stroke subtype categorisation. A sleep study was carried out using a portable respiratory recording device, The entire cohort was followed over a mean period of 22.8 months. The main outcome event was death and time of survival since the neurological event. A multivariate Cox's model was estimated. The patients were ages 72+/-9 yrs (mean+/-SD), and had a body mass index of 26.6+/-3.9 kg x m(-2) and apnoea/hypopnoea index (AHI) of 21.2+/-15.7. Overall, mortality occurred in 22 cases, and the survival rate was 86.3%. Vascular disease accounted for 63.6% of deaths. Multivariate analysis selected four independent variables associated with mortality: 1) age; 2) AHI, with an implied 5% increase in mortality risk for each additional unit of AHI; 3) involvement of the middle cerebral artery; and 4) the presence of coronary disease. In conclusion, the findings suggest that sleep-related breathing disorders are an independent prognostic factor related to mortality after a first episode of stroke.

Age Distribution↗

Noninvasive monitoring of respiratory mechanics during sleep.

The sleep apnoea-hypopnoea syndrome is characterised by recurrent obstructions of the upper airway, resulting in sleep disruption and arterial oxygen desaturations. Noninvasive assessment of respiratory mechanics during sleep is helpful in facilitating the diagnosis and treatment of patients with sleep apnoea-hypopnoea syndrome. This series summarises the different tools that are currently available to noninvasively assess respiratory mechanics during sleep breathing disturbances. These techniques are classified according to the main variable monitored: ventilation, breathing effort or airway obstruction. Changes in patient ventilation are assessed by recording flow or volume signals by means of pneumotachographs, thermistors or thermocouples, nasal prongs or thoraco-abdominal bands. Common tools to noninvasively assess breathing efforts are the thoraco-abdominal bands and the pulse transit time technique. Upper airway obstruction is noninvasively characterised by its upstream resistance and its critical pressure or by means of the forced oscillation technique. Given the technical and practical limitations of each technique, combining different tools improves the reliability and robustness of patient assessment during sleep.

Humans↗

Laser-assisted uvulopalatoplasty for snoring: does it meet the expectations?

The high prevalence of habitual snoring (35% of the general population) and the increasing demand for an effective treatment have led, in the last decade, to the generalisation of laser-assisted uvulopalatoplasty (LAUP). However, acceptable studies on its effectiveness are lacking. The present randomised, placebo-controlled study included 25 nonapnoeic and mild obstructive sleep apnoea snorers to evaluate LAUP effectiveness for snoring. Group I received a one-stage LAUP treatment and group II a placebo (simulated snore surgery followed by an oral placebo). Before each treatment and 3 months after, the variables and procedures assessed were: body weight; sleepiness (Epworth sleepiness scale); quality of life (SF-36); subjective snoring intensity (0-10 analogue scale); objective snoring intensity (average decibel intensity); snoring index (number of snores per hour); and apnoea/hypopnea index. No differences were observed in body weight, sleepiness, quality of life, subjective and objective intensity, and frequency of snoring, and apnoea/hypopnea index between the groups before and 3 months after treatment. In conclusion, this study provides evidence of the lack of effectiveness of one-stage laser-assisted uvulopalatoplasty for snoring in nonapnoeic and mild obstructive sleep apnoea patients, with the result that it does not meet the expectations generated by the procedure.

Adult↗

Design and applications of modified oligonucleotides.

Oligonucleotides have a wide range of applications in fields such as biotechnology, molecular biology, diagnosis and therapy. However, the spectrum of uses can be broadened by introducing chemical modifications into their structures. The most prolific field in the search for new oligonucleotide analogs is the antisense strategy, where chemical modifications confer appropriate characteristics such as hybridization, resistance to nucleases, cellular uptake, selectivity and, basically, good pharmacokinetic and pharmacodynamic properties. Combinatorial technology is another research area where oligonucleotides and their analogs are extensively employed. Aptamers, new catalytic ribozymes and deoxyribozymes are RNA or DNA molecules individualized from a randomly synthesized library on the basis of a particular property. They are identified by repeated cycles of selection and amplification, using PCR technologies. Modified nucleotides can be introduced either during the amplification procedure or after selection.

Drug Design↗

[Protocol to evaluate automatic continuous positive airway pressure. Assessment of the usefulness of the Autoset-T device to determine optimal pressure for treating sleep apnea/hypopnea syndrome].

INTRODUCTION: Given the high prevalence of sleep apnea/hypopnea syndrome (SAHS) and great demand for conventional polysomnography (PSG) and long waiting lists, alternative means for diagnosing SAHS and titrating continuous positive airway pressure (CPAP) are needed. Automatic CPAP may play a role in meeting the last objective, not only for treatment but also for suggesting the optimum CPAP setting. OBJECTIVES: a) To define a protocol to assess the functioning of an automatic CPAP device by means of a mechanical model; b) to determine the behavior of automatically adjusted CPAP during PSG; c) to define the usefulness of automatic CPAP for indicating optimal CPAP pressure for patients with SAHS; d) to evaluate the efficacy of the automatically indicated pressure setting against conventional PSG. METHODS: Four protocols were carried out using the Autoset-T (AT) device. 1. Apneas, hypopneas, flow limitation, snoring and normal flow were simulated in a laboratory using a mechanical model in order to check AT functioning. 2. The behavior of the automatically adjusted CPAP was observed in real time during PSG in 12 patients with severe SAHS. 3. The agreement of CPAP titrated with the AT and with PSG was checked in a group of 39 patients with SAHS. 4. The efficacy of the CPAP pressure recommended by the AT was checked by PSG in a group of 14 patients with SAHS. RESULTS: With the AT, CPAP increased rapidly in response to apneas or snoring in the mechanical model and during conventional PSG; it took only a mean 2.8 3.1 min to rise from a baseline pressure of 4 cm H2O to a near-optimum pressure of 11 1 cm H2O. Once normal flow was reached CPAP slowly decreased, responding with great sensitivity to the slightest abnormality, especially snoring, but not changing in response to certain types of flow limitation. The pressure read visually on the AT was similar to the one recommended by PSG in most of the 39 patients (71%). The PSG performed after one month of using AT-recommended CPAP titration confirmed that the number of apneas, hypopneas (apnea/hypopnea index 6(1) and arousals (8 2) was normal for these SAHS patients. CONCLUSIONS: The AT increases pressure rapidly in the presence of respiratory events and maintains a normal breathing pattern in most patients. Visual reading of the AT pressure allows correct identification of the optimal CPAP setting for SAHS treatment.

Aged↗

Effectiveness of continuous positive airway pressure in mild sleep apnea-hypopnea syndrome.

The aim of this trial was to evaluate the effectiveness of continuous positive airway pressure (CPAP) in patients with mild sleep apnea- hypopnea syndrome (SAHS). One hundred forty-two consecutive patients with mild SAHS (apnea-hypopnea index 10-30, without severe sleepiness) were randomly assigned to receive conservative treatment (CT)-sleep hygiene and weight loss-(65 patients) or CT plus CPAP (77 patients), and 125 patients (86% males, age: 54 +/- 9 yr, BMI: 29 +/- 4 kg/m(2), AHI: 20 +/- 6, ESS: 12 +/- 4) completed the follow-up. The following outcomes were assessed at inclusion and after 3 and 6 mo of treatment: sleepiness (Epworth scale, multiple sleep latency test [MSLT]), other symptoms related to SAHS, cognitive function, and perceived health status (Functional Outcomes of Sleep Questionnaire [FOSQ], Nottingham Health profile). The relief of SAHS-related clinical symptoms was significantly greater in the CPAP group than in the CT group; the Epworth scale and FOSQ also showed more improvement in the CPAP group but did not reach significance. There were no significant differences in the other tests performed probably because the baseline values were normal. CPAP compliance was 4.8 +/- 2.2 h and treatment continuation was accepted by 62% of the patients at the end of the study. These results suggest that CPAP can be considered in treating patients with mild SAHS on the basis of an improvement in symptoms.

Chi-Square Distribution↗

Effectiveness of CPAP treatment in daytime function in sleep apnea syndrome: a randomized controlled study with an optimized placebo.

Application of continuous positive airway pressure (CPAP) as the standard treatment for sleep apnea/hypopnea syndrome (SAHS) is a moot point. Studies on the effectiveness of this treatment have been challenged because of the lack of a suitable placebo. The recent description of a true placebo (sham CPAP) prompted us to conduct a randomized trial of CPAP or placebo to assess the effectiveness of CPAP in improving SAHS-related symptoms and daytime function in patients with moderate to severe SAHS. Forty-eight patients, stratified in four groups according to severity, were randomly allocated into two treatment groups (optimal and sham CPAP) for a 6-wk period. Of these, 45 completed follow-up (91% males; age: 54 +/- 10 yr; body mass index [BMI]: 32 +/- 6 kg/m(2); apnea-hypopnea index [AHI]: 54 +/- 19 events/h; and Epworth Sleepiness Scale [ESS]: 16 +/- 5). The ESS, a questionnaire on SAHS-related symptoms, Functional Outcomes Sleep Questionnaire (FOSQ), and the Short Form Health Survey (SF-36) were completed at inclusion and after treatment. After 10 d of washout, the placebo group was treated with optimal CPAP and reassessed before and after optimal CPAP. The group receiving optimal CPAP when compared with the group with sham CPAP showed considerably greater improvement in the relief of sleepiness (-9.5 versus -2.3, p < 0.001), other SAHS-related symptoms (-18.5 versus -4.5, p < 0.001), vigilance (+8.5 versus +3.4, p = 0.009), and general productivity (+4.0 versus +0.5, p = 0.04) FOSQ scales. Both groups used a similar number of hours for the optimal and the sham CPAP (4.3 versus 4.5, (p = NS). The patients initially treated with placebo CPAP improved significantly more when optimal CPAP was applied for ESS (-2.3 versus -6.7, p < 0.001) and other sleep apnea syndrome (SAS)-related symptoms (-4.5 versus -11.2, p = 0.02). Our study provides strong evidence of the effectiveness of CPAP treatment in improving symptoms and perceived health status in moderate to severe SAHS.

Activities of Daily Living↗

Treatment with continuous positive airway pressure is not effective in patients with sleep apnea but no daytime sleepiness. a randomized, controlled trial.

BACKGROUND: The sleep apnea-hypopnea syndrome is defined by a pathologic number of respiratory events during sleep (the apnea-hypopnea index, defined as the number of apnea and hypopnea episodes per hour) and daytime symptoms (mostly, excessive sleepiness). In patients with the sleep apnea syndrome, treatment with continuous positive airway pressure (CPAP) normalizes both the apnea-hypopnea index and diurnal symptoms. However, the effect of CPAP in persons with a pathologic apnea-hypopnea index without daytime sleepiness is unclear. OBJECTIVE: To investigate the short-term effects of CPAP on quality of life, objective sleepiness, cognitive function, and arterial blood pressure in nonsleepy patients with a pathologic apnea-hypopnea index. DESIGN: Multicenter randomized, placebo-controlled, parallel-group study. SETTING: Six teaching hospitals in Spain. PATIENTS: 55 patients with an apnea-hypopnea index of 30 or greater who did not have daytime sleepiness (Epworth Sleepiness Scale score </= 10). INTERVENTION: Patients were randomly assigned to receive optimal (n = 29) or sham (n = 25) CPAP and were observed for 6 weeks. MEASUREMENTS: Quality of life, objective sleepiness (Multiple Sleep Latency Test score), cognitive function, and arterial blood pressure. RESULTS: The intervention and control groups were similar in terms of mean (+/-SE) age (54 +/- 2 vs. 52 +/- 2 years), apnea-hypopnea index (54 +/- 3 vs. 57 +/- 4), Epworth Sleepiness Scale score (7.0 +/- 0.4 vs. 7.0 +/- 0.4) and adherence to CPAP treatment (5.0 +/- 0.4 vs. 4.0 +/- 0.5 hours/d). Other variables, such as quality of life, cognitive function, and arterial blood pressure, were also similar in both groups before treatment. After 6 weeks of CPAP or sham CPAP, none of these variables changed significantly. CONCLUSION: In patients with an apnea-hypopnea index of 30 or greater and no subjective daytime sleepiness, CPAP does not modify quality of life, objective sleepiness, vigilance, attention, memory, information processing, visuomotor coordination, or arterial blood pressure. Treatment with CPAP is therefore not indicated in nonsleepy patients with a pathologic apnea-hypopnea index.

Blood Pressure↗

New technologies to detect static and dynamic upper airway obstruction during sleep.

Increase in upper airway resistance is the main patho-physiological feature in the obstructive breathing disorders during sleep. Upper airway events may be divided into two main groups: static obstruction (apneas) and dynamic obstruction (hypopneas, flow limitation, and snoring). This classification is useful to provide better information about the patho-physiological mechanisms of obstruction and to better define the diagnostic tools necessary for detecting abnormal respiratory events during sleep. Detection of dynamic obstruction requires sensors with a good frequency response. As thermistors have a poor dynamic response, they are not efficient in detecting the dynamic obstruction but are good enough to detect static obstruction. Nasal prongs (NP) connected a to pressure transducer and the impedance signal measured by the forced oscillation technique (FOT) are relatively new tools to noninvasively investigate dynamic upper airflow obstruction during sleep. FOT provides a direct index of the magnitude of airway obstruction and, therefore, of the upper airway patency, even under conditions of no flow (apneas). NP are aimed at assessing flow. Thus, both techniques have a different scope. The main advantages of NP are that they are easy to use and do not require sophisticated technology, while FOT needs a more complex instrumentation. For clinical routine studies NP are probably the best and simplest method for assessing the different respiratory events during sleep. However, FOT would be particularly useful in selected applications such as assessing upper airway patency in some central apneas; interpreting the irregular pattern of breathing during REM sleep; in better characterizing the inspiratory flow-limited breaths classified as intermediate; and in studying upper airway mechanics.

Polysomnography↗

Relevance of linearizing nasal prongs for assessing hypopneas and flow limitation during sleep.

Respiratory disturbances in patients with the sleep apnea-hypopnea syndrome (SAHS) may be detected by means of nasal prongs (NP) pressure (PNP). Nevertheless, PNP is nonlinearly related to flow (V). Our aim was to demonstrate the relevance of linearizing P NP for assessing hypopneas and flow limitation in SAHS. V was measured with a pneumotachograph during the hypopneas and flow limitation events in a continuous positive airway pressure (CPAP) titration in six patients with severe SAHS. These flow patterns were reproduced by a flow generator through an analog of the nares and recorded by NP. PNP was linearized [V NP = (PNP)1/2] by a specially designed analog circuit. For each event we used V, P NP, and V NP to compute the hypopnea flow amplitude (HFA) and a flow limitation index (FLI). Owing to NP nonlinearity, PNP considerably misestimated HFA and FLI. By contrast, V NP provided HFA and FLI values that were very close to those obtained from V: HFA (V NP) = 1.098. HFA(V) - 0.063 (r2 = 0.98) and FLI(V NP) = 1.044. FLI(V) + 0.004 (r2 = 0.99). Square-root linearization of NP greatly increases the accuracy of quantifying hypopneas and flow limitation. This procedure, which could be readily carried out in routine practice by means of the analog circuit we developed, is of interest in optimizing the assessment of respiratory sleep disturbances in SAHS.

Computers, Analog↗

Forced oscillation measurements do not affect upper airway muscle tone or sleep in clinical studies.

Upper airway obstruction in the sleep apnoea/hypopnoea syndrome (SAHS) can be easily assessed by measuring respiratory impedance with the forced oscillation technique (FOT). This methodology has been proposed as a useful clinical tool both for the diagnosis of sleep breathing disorders and for continuous positive airway pressure (CPAP) titration. However, previous studies suggest that the application of high-frequency pressure oscillation to the upper airway may induce changes in the electroencephalogram (EEG) or upper airway muscle function. The effect of FOT measurements on upper airway muscle tone and EEG in clinical sleep studies was examined. Seven patients with moderate SAHS were included (age: 54+/-11 yrs; apnoea/hypopnoea index: 43+/-21 events x h(-1); body mass index: 30+/-2 kg x m(-2)). Genioglossus surface electromyogram activity (EMGgg) and EEG signal were analysed with and without FOT application (frequency: 5 Hz and 30 Hz; peak-to-peak pressure oscillation: 1 cmH2O) during stable sleep. Measurements were carried out in two different situations. Step 1: applying FOT during episodes of obstructive events or flow limitation; and step 2: during prolonged periods of normal breathing at optimal CPAP. The root mean square of EMGgg activity and fast Fourier analysis (alpha and delta bands) of the EEG signal were performed. The application of FOT did not increase EMGgg activity in any of the situations studied. In addition, no evidence of the effects on EEG was found: alpha/delta relationship: awake:0.70, baseline sleep:0.13, FOT(5 Hz):0.18, FOT(30 Hz):0.11. The presented results suggest that the use of forced oscillation technique over the ranges of frequency and amplitude proposed for clinical sleep studies does not induce changes in upper airway muscle activity and neurological variables in patients with sleep apnoea/hypopnoea syndrome.

Airway Obstruction↗

Evaluation of a simplified oscillation technique for assessing airway obstruction in sleep apnoea.

The forced oscillation technique (FOT) is a noninvasive method that is useful for assessing airway obstruction and for titrating continuous positive airway pressure (CPAP) in patients with sleep apnoea. The aim was to evaluate the routine applicability of a simplified FOT set-up based on recording pressure and flow at the level of the CPAP device, i.e. obviating the need for connecting the transducers to the nasal mask. A correction to account for the tubing and the exhaust port was applied. This simplified FOT was evaluated on nine patients with moderate or severe sleep apnoea during routine CPAP titration. Patient impedance measured by the simplified FOT ([Z]) was compared with actual patient impedance ([Zrs]) measured simultaneously with a reference FOT based on recording pressure and flow at the nasal mask. An excellent agreement was found between [Z] and [Zrs] over the wide range of airway obstruction explored (4.8-72.1 cmH2O x s x L(-1)): [Z] = [Zrs] x 0.86 + 1.3 cmH2O x s x L(-1) (r = 0.99). Moreover, the simplified and the conventional FOT settings detected the same respiratory events during sleep. These results demonstrate that this simplified FOT is applicable for measuring airway obstruction during routine sleep studies in patients with sleep apnoea.

Airway Obstruction↗

Performance of nasal prongs in sleep studies : spectrum of flow-related events.

OBJECTIVES: The use of nasal prongs connected to a pressure transducer is a noninvasive, sensitive method to detect respiratory events, and can be easily implemented in routine sleep studies. Moreover, its good time response allows the detection of several flow-related phenomena of high interest, in addition to apnea and hypopnea. The aims of the study were to examine the quality and performance of the nasal prong flow signal, and to describe other flow-related events during full-night polysomnography studies. METHODS: Twenty-seven subjects were studied (16 male subjects; mean +/- SD age, 49 +/- 14 years; mean body mass index, 27 +/- 4 kg/m(2)): 15 subjects recruited from the general population and 12 consecutive patients with suspected sleep apnea/hypopnea syndrome (SAHS). RESULTS: A blind analysis of the respiratory events detected both by nasal prongs and thermistor was done. The quality of the nasal prong signal recordings was considered optimal for scoring purposes in 78% of cases, and no recording was considered uninterpretable. The nasal prong signal detected additional flow-related events not observed by the thermistor: (1) short and long (> 2 min) periods of inspiratory flow limitation morphology without decrease in the amplitude of the signal; (2) periods of mouth expiration; and (3) snoring. The apnea/hypopnea index was significantly higher with the nasal prong scoring (18 vs 11 [p < 0.05] in the general population and 37 vs 27 [p < 0.001] in the group with suspected SAHS). CONCLUSIONS: The incorporation of nasal prongs in routine full-night studies is an attainable technical option that provides adequate recordings in most cases. Additionally, relevant information not scored by thermistors is obtained on flow-related respiratory events, thus increasing diagnostic accuracy.

Adult↗

Evaluation of a portable respiratory recording device for detecting apnoeas and hypopnoeas in subjects from a general population.

This study was designed to validate a new home portable respiratory recording device (PRRD) to identify sleep apnoea and hypopnoea in a group of subjects (n=116), from a sample of the general population. Full night polysomnography (PSG) was used as the gold standard and simultaneously performed with PRRD. PRRD measurements included oronasal airflow (thermistry), chest wall impedance, oxygen saturation, snoring and body position. The sensors were unique for each recording system. Data obtained was blindly reviewed and analysed. A high level of agreement between both methods apnoea/hypopnoea index by PSG and the respiratory disturbance index (RDI) by PRRD was observed. Accuracy of the PRRD was evaluated in terms of sensitivity and specificity for different RDI-PRRD cut-off points with respect to AHI-PSG >10 and AHI-PSG >30. A logistic regression model was performed to estimate the chance per unit of RDI of apnoeas. A received operating characteristic (ROC) curve was drawn to obtain the sensitivity/specificity profile for each observed RDI value obtained. From the ROC curve the authors identified the better cut-off points, which represent a balanced sensitivity/specificity. Through a classification table defined by the cut-off point, the post-odds to exhibit the disease was calculated. For a full PSG cut-off point of 10 a PRRD of six showed a balanced sensitivity of 95% and a specificity of 92%. For a full PSG cut-off point of 30 a PRRD of 16 shows a balanced sensitivity/specificity (100% and 97%, respectively). Post odds of apnoea were calculated for each cut-off point. In conclusion, these data suggest that the portable respiratory recording device is an effective device to identify apnoeas and hypopnoeas in a general population and is therefore a suitable device to be used in epidemiological studies.

Female↗

Time course of sleep-related breathing disorders in first-ever stroke or transient ischemic attack.

To investigate the prevalence and behavior of sleep-related breathing disorders (SRBDs) associated with a first-ever stroke or transient ischemic attack (TIA), we prospectively studied 161 consecutive patients admitted to our stroke unit. Complete neurological assessment was performed to determine parenchymatous and vascular localization of the neurological lesion. Stroke subtype was categorized as TIA, ischemic (IS), or hemorrhagic (HS). A portable respiratory recording (PRR) study was performed within 48-72 h after admission (acute phase), and subsequently after 3 mo (stable phase). During the acute phase, 116 patients (71.4%) had an apnea-hypopnea index (AHI) > 10 events/h and 45 (28%) had an AHI > 30. No relationships were found between sleep-related respiratory events and the topographical parenchymatous location of the neurological lesion or vascular involvement. Cheyne-Stokes breathing (CSB) was observed in 42 cases (26.1%). There were no significant differences in SRBD according to the stroke subtype except for the central apnea index (CAI). During the stable phase a second PRR was performed in 86 patients: 53 of 86 had an AHI > 10 and 17 of 86 had an AHI > 30. The AHI and CAI were significantly lower than those in the acute phase (16.9 +/- 13.8 versus 22.4 +/- 17.3 and 3.3 +/- 7.6 versus 6.2 +/- 10.2, respectively) (p < 0.05) while the obstructive apnea index (OAI) remained unchanged. CSB was observed in 6 of 86 patients. The prevalence of SRBD in patients with first-ever stroke or TIA is higher than expected from the available epidemiological data in our country. No correlation was found between neurological location and the presence or type of SRBD. Obstructive events seem to be a condition prior to the neurological disease whereas central events and CSB could be its consequence.

Aged↗

[Measurement of the perceived impact of sleep problems: the Spanish version of the functional outcomes sleep questionnaire and the Epworth sleepiness scale].

BACKGROUND: Excessive daytime sleepiness is a frequent symptom and a public health problem due to its association with automobile and work related accidents. The aim of this study was to develop and carry out a preliminary assessment of the Spanish version of the functional outcomes sleep questionnaire and the Epworth sleepiness scale, two instruments designed to evaluate patients with sleep disorders. MATERIAL AND METHODS: For the adaptation, the forward and back-translation method by bilinguals was used with professional and lay panel. Once tested for feasibility and comprehension, 39 patients with obstructive sleep apnea syndrome completed the Spanish version of the FOSQ and the Epworth sleepiness scale, together with a question on self-rated health status. RESULTS: Difficulty of translation was assessed as low and the naturalness of Spanish expressions as high for all the items of the questionnaires except for the response options of the Epworth sleepiness scale. Both questionnaires showed higher reliability than the standard proposed for individual comparisons (Cronbach's alpha > 0.9). The FOSQ vigilance scale showed a high correlation with the Epworth score (r = -0.79), while for the other scales of the FOSQ correlations were moderate (r ranging from -0.52 to -0.68). Patients who reported "regular" or "poor" health had significantly worse scores for most of the FOSQ scales. CONCLUSION: These results suggest that the Spanish versions of both questionnaires are conceptually equivalent to the originals and that they show similar characteristics of reliability and validity. The FOSQ vigilance scale assess daytime sleepiness similarly to Epworth but the others scales of the FOSQ provide additional information for these patients.

Female↗