Recommendations on performance characteristics of diagnostic exposure meters: report of AAPM Diagnostic X-Ray Imaging Task Group No. 6.

Task Group 6 of the Diagnostic X-Ray Imaging Committee of the American Association of Physicists in Medicine (AAPM) was appointed to develop performance standards for diagnostic x-ray exposure meters. The recommendations as approved by the Diagnostic X-Ray Imaging Committee and the Science Council of the AAPM are delineated in this report and provide specifications on meter precision, calibration accuracy, calibration reference points, linearity, energy dependence, exposure rate dependence, leakage, amplification gain settings, directional dependence, the stem effect, constancy checks, and calibration intervals. The report summarizes recommendations for meters used in mammography, general purpose radiography including special procedures, computed tomography, and radiation safety surveys for x-ray radiography.

Child↗

A survey of fluoroscopic exposure rates: AAPM Task Group No. 11 Report.

Fluoroscopic procedures, in general, result in much higher exposures to patients than do most types of radiographic procedures [National Council on Radiation Protection, Report 100, p. 31 (1989)]. In spite of this, fluoroscopic exposure rates can vary widely between systems, and often for no apparent reason. The charge of AAPM Task Group No. 11 was to evaluate fluoroscopic exposure rates at the entrant surface of the x-ray image intensifier, and to disseminate this information so that medical physicists could compare their own exposure rate measurements with typical values. The measurement protocol was defined for various system configurations. Sheets of copper were used to attenuate the x-ray beam, and the input exposure rate at the image intensifier (at the input mode closest to 23-cm diameter) in the absence of a scattering medium was determined. With 2 mm of copper as x-ray beam filtration, the median fluoroscopic exposure rate at the image intensifier was found to be 16.5 nC/kg/s (64.0 microR/s), with an average kV of 77 and mA of 2.0 (n = 62).

Fluoroscopy↗

Filter wheel equalization in DSA: simulation results.

Digital subtraction angiography (DSA) is a valuable and frequently used diagnostic technique which allows the evaluation of vascular anatomy and pathology. In order to improve the utility and diagnostic performance of DSA, a filter wheel system is presented which can provide mechanically simple, rapidly adaptable, and clinically practical radiographic equalization to DSA images. The filter wheel equalization system consists of a series of computer-driven filter wheels, mounted between the x-ray tube and collimator. Each wheel has an annular area of attenuator material which intersects the x-ray beam and carries a rotationally varying compensation pattern on it. Rotation of the filter wheel modulates the attenuator pattern in the x-ray field under computer control, in a manner designed to increase the x-ray exposure to underexposed areas in the image. A system with eight wheels has 10(19) possible equalization patterns. The compensation patterns are removed in the subtracted DSA images. Computer simulation techniques were used to evaluate various design scenarios for the filter wheel system, using a data base of 191 clinical DSA mask images. For a practical implementation of the filter wheel system, an improvement in the signal to noise ratio of 23%, averaged over the image, was found.

Angiography, Digital Subtraction↗