An accurate method for computer-generating tungsten anode x-ray spectra from 30 to 140 kV.

A tungsten anode spectral model using interpolating polynomials (TASMIP) was used to compute x-ray spectra at 1 keV intervals over the range from 30 kV to 140 kV. The TASMIP is not semi-empirical and uses no physical assumptions regarding x-ray production, but rather interpolates measured constant potential x-ray spectra published by Fewell et al. [Handbook of Computed Tomography X-ray Spectra (U.S. Government Printing Office, Washington, D.C., 1981)]. X-ray output measurements (mR/mAs measured at 1 m) were made on a calibrated constant potential generator in our laboratory from 50 kV to 124 kV, and with 0-5 mm added aluminum filtration. The Fewell spectra were slightly modified (numerically hardened) and normalized based on the attenuation and output characteristics of a constant potential generator and metal-insert x-ray tube in our laboratory. Then, using the modified Fewell spectra of different kVs, the photon fluence phi at each 1 keV energy bin (E) over energies from 10 keV to 140 keV was characterized using polynomial functions of the form phi (E) = a0[E] + a1[E] kV + a2[E] kV2 + ... + a(n)[E] kVn. A total of 131 polynomial functions were used to calculate accurate x-ray spectra, each function requiring between two and four terms. The resulting TASMIP algorithm produced x-ray spectra that match both the quality and quantity characteristics of the x-ray system in our laboratory. For photon fluences above 10% of the peak fluence in the spectrum, the average percent difference (and standard deviation) between the modified Fewell spectra and the TASMIP photon fluence was -1.43% (3.8%) for the 50 kV spectrum, -0.89% (1.37%) for the 70 kV spectrum, and for the 80, 90, 100, 110, 120, 130 and 140 kV spectra, the mean differences between spectra were all less than 0.20% and the standard deviations were less than approximately 1.1%. The model was also extended to include the effects of generator-induced kV ripple. Finally, the x-ray photon fluence in the units of photons/mm2 per mR was calculated as a function of HVL, kV, and ripple factor, for various (water-equivalent) patient thicknesses (0, 10, 20, and 30 cm). These values may be useful for computing the detective quantum efficiency, DQE(f), of x-ray detector systems. The TASMIP algorithm and ancillary data are made available on line at http:/(/)www.aip.org/epaps/epaps.html.

Algorithms↗

Lens coupling efficiency: derivation and application under differing geometrical assumptions.

The calculation of lens coupling efficiency is often performed in the design of lens coupled digital radiographic system, now currently under development. With these systems, an electronic camera is focused onto a planar scintillator such as a conventional intensifying screen. Historically, this calculation has relied on certain assumptions concerning the emission properties of the scintillator, and primarily this assumption is that the scintillator is either a Lambertain emitter (light is emitted over all angles equally) or a point radiator. Because there now exists new classes of scintillators such as scintillating fiber optic screens and pixelated intensifying screens, it is sometimes necessary to perform lens coupling calculations in the absence of the Lambertian and point source assumptions. In this paper we describe the necessary equations to accurately calculate lens coupling efficiency in the most general of cases. Graphical examples demonstrate the lens coupling efficiency for hypothetical Lambertain scintillating sources, for a rare earth intensifying screen, and for a scintillating fiber optical screen.

Electronics↗

Scintillating fiber optic screens: a comparison of MTF, light conversion efficiency, and emission angle with Gd2O2S:Tb screens.

The widespread effort in developing digital imaging systems has led to large area high pixel density photodetectors such as charge coupled devices (CCDs), amorphous silicon photodiode arrays, and complementary metal oxide semiconductor (CMOS) imagers. These photodetectors have different capabilities, characteristics, and requirements than conventional silver-halide-based film, and this fact had led to a new generation of exotic scintillators, including fiber optic screens made from scintillating glass. The scintillator performance characteristics of five different scintillating fiber optic screens and two conventional Gd2O2S:Tb screens (one 34 mg/cm2 and the other 60 mg/cm2) were measured and compared. The measurements that were made included the angular dependence of light emission relative to the normal, the modulation transfer function (MTF), and the absolute effective conversion efficiency (light photons per absorbed x-ray photon). It was found that the light emission of scintillating fiber optic screens is markedly forward peaked (depending on the sample) compared to conventional screens or Lambertian emitters. The MTFs of the five scintillating fiber optic screens measured were comparable and fell approximately midway between the two conventional screen MTFs. One of the scintillating fiber optic screens demonstrated light efficiency similar to the thick (60 mg/cm2) conventional screen, another had light output capabilities similar to the thin (34 mg/cm2) conventional screen, and the three others were less efficient than the thin screen. The non-Lambertian characteristics of the fiber optic scintillators will cause errors of up to 75% in lens efficiency calculations if a Lambertian source is assumed. The conventional screens were found to conform within about 5% of an ideal Lambertian emitter.

Biophysical Phenomena↗

Molybdenum, rhodium, and tungsten anode spectral models using interpolating polynomials with application to mammography.

Computer simulation is a convenient and frequently used tool in the study of x-ray mammography, for the design of novel detector systems, the evaluation of dose deposition, x-ray technique optimization, and other applications. An important component in the simulation process is the accurate computer-generation of x-ray spectra. A computer model for the generation of x-ray spectra in the mammographic energy range from 18 kV to 40 kV has been developed. The proposed model requires no assumptions concerning the physics of x-ray production in an x-ray tube, but rather makes use of x-ray spectra recently measured experimentally in the laboratories of the Center for Devices and Radiological Health. Using x-ray spectra measured for molybdenum, rhodium, and tungsten anode x-ray tubes at 13 different kV's (18, 20, 22, ..., 42 kV), a spectral model using interpolating polynomials was developed. At each energy in the spectrum, the x-ray photon fluence was fit using 2, 3, or 4 term (depending on the energy) polynomials as a function of the applied tube voltage (kV). Using the polynomial fit coefficients determined at each 0.5 keV interval in the x-ray spectrum, accurate x-ray spectra can be generated for any arbitrary kV between 18 and 40 kV. Each anode material (Mo, Rh, W) uses a different set of polynomial coefficients. The molybdenum anode spectral model using interpolating polynomials is given the acronym MASMIP, and the rhodium and tungsten spectral models are called RASMIP and TASMIP, respectively. It is shown that the mean differences in photon fluence calculated over the energy channels and over the kV range from 20 to 40 kV were -0.073% (sigma = 1.58%) for MASMIP, -0.145% (sigma = 1.263%) for RASMIP, and 0.611% (sigma = 2.07%) for TASMIP. The polynomial coefficients for all three models are given in an Appendix. A short C subroutine which uses the polynomial coefficients and generates x-ray spectra based on the proposed model is available on the World Wide Web at http:/(/)www.aip.org/epaps/epaps.html.

Aluminum↗

Sinusoidal modulation analysis for optical system MTF measurements.

The modulation transfer function (MTF) is a commonly used metric for defining the spatial resolution characteristics of imaging systems. While the MTF is defined in terms of how an imaging system demodulates the amplitude of a sinusoidal input, this approach has not been in general use to measure MTFs in the medical imaging community because producing sinusoidal x-ray patterns is technically difficult. However, for optical systems such as charge coupled devices (CCD), which are rapidly becoming a part of many medical digital imaging systems, the direct measurement of modulation at discrete spatial frequencies using a sinusoidal test pattern is practical. A commercially available optical test pattern containing spatial frequencies ranging from 0.375 cycles/mm to 80 cycles/mm was sued to determine the MRF of a CCD-based optical system. These results were compared with the angulated slit method of Fujita [H. Fujita, D. Tsia, T. Itoh, K. Doi, J. Morishita, K. Ueda, and A. Ohtsuka, "A simple method for determining the modulation transfer function in digital radiography," IEEE Trans. Medical Imaging 11, 34-39 (1992)]. The use of a semiautomated profiled iterated reconstruction technique (PIRT) is introduced, where the shift factor between successive pixel rows (due to angulation) is optimized iteratively by least-squares error analysis rather than by hand measurement of the slit angle. PIRT was used to find the slit angle for the Fujita technique and to find the sine-pattern angle for the sine-pattern technique. Computer simulation of PIRT for the case of the slit image (a line spread function) demonstrated that it produced a more accurate angle determination than "hand" measurement, and there is a significant difference between the errors in the two techniques (Wilcoxon Signed Rank Test, p < 0.001). The sine-pattern method and the Fujita slit method produced comparable MTF curves for the CCD camera evaluated.

Biophysical Phenomena↗

Comparison of x-ray cross sections for diagnostic and therapeutic medical physics.

The purpose of this technical report is to make available an up-to-date source of attenuation coefficient data to the medical physics community, and to compare these data with other more familiar sources. Data files from Lawrence Livermore National Laboratory (in Livermore, CA) were truncated to match the needs of the medical physics community, and an interpolation routine was written to calculate a continuous set of cross sections spanning energies from 1 keV to 50 MeV. Coefficient data are available for elements Z = 1 through Z = 100. Values for mass attenuation coefficients, mass-energy-transfer coefficients, and mass-energy absorption coefficients are produced by a single computer subroutine. In addition to total interaction cross sections, the cross sections for photoelectric, Rayleigh, Compton, pair, and some triplet interactions are also produced by this single program. The coefficients were compared to the 1970 data of Storm and Israel over the energy interval from 1 to 1000 keV; for elements 10, 20, 30, 40, 50, 60, 70, and 80, the average positive difference between the Storm and Israel coefficients and the coefficients reported here are 1.4%, 2.7%, and 2.6%, for the mass attenuation, mass energy-transfer, and mass-energy absorption coefficients, respectively. The 1969 data compilation of mass attenuation coefficients from McMaster et al. were also compared with the newer LLNL data. Over the energy region from 10 keV to 1000 keV, and from elements Z = 1 to Z = 82 (inclusive), the overall average difference was 1.53% (sigma = 0.85%). While the overall average difference was small, there was larger variation (> 5%) between cross sections for some elements. In addition to coefficient data, other useful data such as the density, atomic weight, K, L1, L2, L3, M, and N edges, and numerous characteristic emission energies are output by the program, depending on a single input variable. The computer source code, written in C, can be accessed and downloaded from the World Wide Web at: http:@www.aip.org/epaps/epaps.html [E-MPHSA-23-1977].

Biophysical Phenomena↗

Medical physics.

Explore the source record for details and available documents.

Biophysics↗

Filter wheel equalization for chest radiography: a computer simulation.

A chest radiographic equalization system using lung-shaped templates mounted on filter wheels is under development. Using this technique, 25 lung templates for each lung are available on two computer controlled wheels which are located in close proximity to the x-ray tube. The large magnification factor (> 10X) of the templates assures low-frequency equalization due to the blurring of the focal spot. A low-dose image is acquired without templates using a (generic) digital receptor, the image is analyzed, and the left and right lung fields are automatically identified using software developed for this purpose. The most appropriate left and right lung templates are independently selected and are positioned into the field of view at the proper location under computer control. Once the templates are positioned, acquisition of the equalized radiographic image onto film commences at clinical exposure levels. The templates reduce the exposure to the lung fields by attenuating a fraction of the incident x-ray fluence so that the exposure to the mediastinum and diaphragm areas can be increased without overexposing the lungs. A data base of 824 digitized chest radiographs was used to determine the shape of the specific lung templates, for both left and right lung fields. A second independent data base of 208 images was used to test the performance of the templates using computer simulations. The template shape characteristics derived from the clinical image data base are demonstrated. The detected exposure in the lung fields on conventional chest radiographs was found to be, on average, three times the detected exposure behind the diaphragm and mediastinum.(ABSTRACT TRUNCATED AT 250 WORDS)

Biophysical Phenomena↗

A fully automated algorithm for the segmentation of lung fields on digital chest radiographic images.

A completely automated algorithm is presented which is capable of identifying both the right- and left-lung fields on digitized chest radiographic images. The algorithm is tested on a sample of 802 chest images against lung fields drawn by a human observer. The average accuracies are found to be 0.957 +/- 0.003 and 0.960 +/- 0.003 for right- and left-lung regions, respectively. To put them into perspective, the results are compared to several other simple segmentation techniques. These include a comparison of two sets of lung fields drawn by the human observer at different times which yielded accuracies of 0.967 +/- 0.005 and 0.967 +/- 0.004 for right- and left-lung regions, respectively.

Algorithms↗

Pediatric skeletal age: determination with neural networks.

PURPOSE: To develop a neural network to calculate skeletal age based on measurements taken from digitized hand radiographs. MATERIALS AND METHODS: From a database of 521 hand radiographs obtained in healthy patients, four parameters were calculated from seven linear measurements and were used to train a neural network, with use of the jackknife method, to calculate skeletal age. The results were compared with those of an experienced pediatric radiologist using a standard pediatric skeletal atlas. RESULTS: The mean difference from biologic age for the neural network was -0.261 years +/- 1.82 (standard deviation) and for the radiologist, -0.232 years +/- 1.54; this difference was not significantly different (P = .67, Wilcoxon signed rank test). Skeletal age determined by the neural network was closer to the biologic age than that assigned by the radiologist in 243 of 521 cases (47%). CONCLUSION: A simple neural network may assist radiologists in the assessment of skeletal age.

Adolescent↗

Filter wheel equalization in chest radiography: demonstration with a prototype system.

PURPOSE: To determine the feasibility of using the filter wheel equalization (FWE) technique for radiographic equalization in chest radiography. MATERIALS AND METHODS: An FWE system with two rotating wheels (one for each lung) with 25 lung-shaped, 1.0-mm-thick copper templates was constructed. Preexposure images were acquired; the computer used these images to select and position templates for each lung. An equalized radiograph was then produced. Radiographs were acquired in two male volunteers (both 33 years of age) and in a phantom. RESULTS: Optical densities in the lungs and nonlung areas on a conventional phantom radiograph were 2.07 and 0.55, respectively; after equalization, the corresponding optical densities were 2.06 and 1.42. Outside the lungs, radiographic contrast (difference in optical density) increased threefold; in the lungs, there was a very small decrease in radiographic contrast due to beam hardening. Well-equalized and relatively artifact-free radiographs were obtained with a 20-msec exposure time. CONCLUSION: The FWE system was shown in the laboratory to be feasible.

Absorptiometry, Photon↗

A comparison of mono- and poly-energetic x-ray beam performance for radiographic and fluoroscopic imaging.

The purpose of this investigation was to evaluate the potential of monoenergetic x-ray sources to improve image quality and reduce patient dose compared to conventional tungsten anode x-ray spectra. This was purely a computer simulation study. X-ray spectra were generated using the Birch and Marshal spectral model, patient x-ray transmission was calculated using Monte Carlo techniques, and a numerical method was developed for determining antiscatter grid performance. A 120 mg/cm2 Gd2O2S intensifying screen was simulated for radiography and a 144 mg/cm2 CsI image intensifier was simulated for fluoroscopy. The source of subject contrast that was simulated included tissue, calcium, and iodine targets which varied in mass thicknesses from 10 to 1000 mg/cm2. The figure of merit of the [contrast to noise ratio] 2/[integral dose] was used as a relative measure of dose utilization. Depending on the object thickness, monoenergetic x-ray sources with a screen-film detector exhibited a 1.4 to 2.4 improvement over tungsten anode spectra for iodine contrast, a 1.5 to 2.0 improvement for calcium imaging, and about a 1.4 to 1.6 improvement for tissue contrast. The thicker patients (30 cm) benefitted more than thinner (10 cm) ones. For the image intensifier as a detector, a 1.4-2.3 improvement factor was found for monoenergetic sources and an iodine signal object. For the practical range of radiographic imaging scenarios using present-day detector technologies, monoenergetic sources may provide an improvement in dose utilization that is comparable to the improvements that can be expected with scanning slit devices over conventional antiscatter grids.

Algorithms↗

An analytical edge spread function model for computer fitting and subsequent calculation of the LSF and MTF.

The previous work of Yin, Giger, and Doi [Med. Phys. 17, 962-966 (1990)] demonstrated that using a computerized fit of an analytic line spread function to experimentally measured data is very useful for determining the presampling modulation transfer function of an imaging system. In this report, the work of Yin et al. is extended to include an analytic expression for the edge spread function (ESF). By fitting experimentally determined edge spread function data to the analytical expression, the normalized line spread function (LSF) and the normalized modulation transfer function (MTF) can be easily calculated from four ESF fit coefficients. The extension from the line spread function to the edge spread function should be valuable in cases where slit measurements are impractical, for example, in very high resolution imaging systems where the required slit dimensions become impractically small, or in measurements of the transfer properties of scattered radiation or off-focus radiation, where large area exposures are necessary.

Algorithms↗

Mapping myocardial activation distributions using neural networks: 2-D simulation results.

The goal of this study was to explore the capabilities of neural networks to map with accuracy the sequence and location of myocardial activation using QRS complexes simulating normal and altered activation. A two-dimensional (2-D) fractal-based computer model of myocardial activation was used to develop training data for initial network learning. Two types of activation scenarios were used to evaluate network learning: 1) 450 training sets based on three activation foci per set using randomly chosen times and activation sites, and 2) 199 training sets based on a sequential, hierarchical blocking of the fractal-based model conduction network. Network learning was evaluated with training and test cases using trained weights. Network-calculated activation maps compared with the target activation maps had a mean error of < 5% in assigning the site and timing of activation. Pointwise mean correlation coefficients were > 0.98 for all conduction network cases and > 0.84 for the more demanding point foci cases. We conclude, based on these simulation results, that neural networks may be used to calculate activation maps using electrocardiogram lead data for a variety of activation patterns.

Animals↗

A fluoroscopy-based computed tomography scanner for small specimen research.

RATIONALE AND OBJECTIVES: A small-laboratory computed tomography (CT) system using a fluoroscopic system and a personal computer was fabricated and tested. The motivation for building this specimen scanner was to provide medical researchers with the capability of using CT as a practical tool in their research, as well as to provide an opportunity for hands-on CT instruction. METHODS AND MATERIALS: The CT system was constructed using mostly off-the-shelf items; however, the CT stage itself was custom fabricated and software development was necessary. In addition, a personal computer and a standard fluoroscopy system were used. RESULTS: The spatial resolution was found to match the 228-microns sampling limitation, yielding approximately 2 line pairs per mm. Iodine contrast sensitivity studies showed that 1% solution of 370 mg/ml iodine solution was easily detected (P = .05). CONCLUSIONS: A small CT scanner for specimen research can be economically constructed, and is capable of good performance. The authors found substantial interest on the part of small animal researchers involved in a wide variety of medical research.

Animals↗

Recognition of chest radiograph orientation for picture archiving and communications systems display using neural networks.

A neural network classification scheme was developed that enables a picture archiving and communications system workstation to determine the correct orientation of posteroanterior or anteroposterior chest images. This technique permits thoracic images to be displayed conventionally when called up on the workstation, and therefore reduces the need for reorientation of the image by the observer. Feature data were extracted from 1,000 digitized chest radiographs and used to train a two-layer neural network designed to classify the image into one of the eight possible orientations for a posteroanterior chest image. Once trained, the neural network identified the correct image orientation in 888 of 1,000 images that had not previously been seen by the neural network. Of the 112 images that were incorrectly classified, 106 were mirror images of the correct orientation, whereas only 6 actually had the caudal-cranial axis aligned incorrectly. The causes for misalignment are discussed.

Humans↗