Search PubMed⌕ Search

Biomedical subjects

J Link

Publications and source records attributed to J Link.

At least 19 recordsLinked to original sources

Elevated expression and genetic association links the SOCS3 gene to atopic dermatitis.

In a systematic analysis of global gene-expression patterns, we found that SOCS3 messenger RNA was significantly more highly expressed in skin from patients with atopic dermatitis than in skin from healthy controls, and immunohistochemical analysis confirmed a similar elevation of SOCS3 protein. Furthermore, we found a genetic association between atopic dermatitis and a haplotype in the SOCS3 gene in two independent groups of patients (P<.02 and P<.03). These results strongly suggest that SOCS3, located in a chromosomal region previously linked to the disease (17q25), is a susceptibility gene for atopic dermatitis.

Adult↗

Renal effects of gadopentetate dimeglumine in patients with normal and impaired renal function.

Gadolinium chelates are widely used in magnetic resonance imaging as contrast medium in patients with nephropathy. However, only few studies have investigated the effect of gadolinium on serum creatinine concentration and estimated GFR as surrogate markers of renal function. This study was performed to evaluate the effect of gadopentetate dimeglumine in a dose sufficient for diagnostic and interventional purposes on renal function in a large sample of patients. We analyzed serum creatinine and serum-urea levels before and after the administration of gadopentetate dimeglumine in patients with normal and patients with pre-existing impaired renal function. Age, height, body mass, sex, medication and preexisting illnesses such as diabetes, renal artery stenosis and heart disease were monitored. In 181 patients with normal renal function, there was no statistically significant change in serum creatinine concentration after the administration of gadopentetate dimeglumine (at baseline: 0.72 +/- 0.18 mg/dl, after gadolinium: 0.73 +/- 0.22 mg/dl). In contrary, serum creatinine levels decreased significantly after the administration of gadolinium in 198 patients with pre-existing renal impairment (1.82 +/- 1.03 mg/dl before and 1.72 +/- 1.03 mg/dl after gadolinium) (p < 0.01). According to this surrogate marker of renal function, the change of estimated GFR in patients with normal baseline renal function was not significant, while in patients with impaired renal function, GFR increased after the administration of gadolinium (p < 0.001). The high diagnostic value of gadolinium contrast media is associated with a very small risk of adverse reactions. Our findings show that the administration of gadolinium even is associated with a decrease of serum creatinine in patients with pre-existing renal impairment. In conclusion, the use of gadolinium-based contrast media may be considered as a safe alternative in patients with impaired renal function for whom use of iodine-based contrast agents is prone to a high rate of radiocontrast-induced nephropathy.

Contrast Media↗

Clinical and angiographic outcome after interventional treatment of the iliac arteries with a new carbofilm coated stent: preliminary results.

PURPOSE: To evaluate the handling, the procedural success rate and the six-month outcome of a new Carbofilm coated balloon-expandable stent in iliac artery lesions. MATERIALS AND METHODS: In a prospective study, 46 stenoses and 2 occlusions of the iliac arteries were primarily stented in 30 patients with the Isthmus CarboStent (Sorin Biomedica Cardio S.p. A., Saluggia, Italy). The ankle-brachial index (ABI) at rest was determined before intervention and at the six-month follow-up visit. Iliac angiography, including intraarterial pressure measurement, was performed before intervention, post-procedurally and at the follow-up visit. RESULTS: All lesions were treated with procedural success. The mean degree of all stenoses was 73.9 % +/- 14.6 before and 2.4 % +/- 8.2 after intervention. The mean pressure gradient was 15.6 mm Hg +/- 10.1 before and 2.5 mm Hg +/- 2.7 after treatment. No or only a mild restenosis developed in 27 patients. The mean ABI increased from 0.64 +/- 0.21 to 0.86 +/- 0.33 and the mean pressure gradient was 2.7 mm Hg +/- 5.4 at the six-month visit. The six-month patency rate was 97.9 %. Three patients showed acute stent thrombosis due to an insufficient postprocedural antiplatelet regimen. DISCUSSION: The Isthmus CarboStent is a safe and easy to handle balloon-expandable stent for interventional therapy of iliac artery lesions. The six-month patency rate is good. Despite its Carbofilm coating, postprocedural antiplatelet therapy is necessary.

Administration, Oral↗

High-resolution contrast-enhanced magnetic resonance angiography of the carotid arteries using fluoroscopic monitoring of contrast arrival: diagnostic accuracy and interobserver variability.

PURPOSE: To evaluate the diagnostic accuracy of high-resolution contrast-enhanced magnetic resonance angiography (CE-MRA) of the supra-aortic arteries using the CareBolus technique. Digital subtraction angiography was the standard of reference. MATERIAL AND METHODS: Fifty consecutive patients with suspected internal carotid artery stenosis underwent CE-MRA and digital subtraction angiography. CE-MRA was performed on a 1.5-T superconducting scanner with the CareBolus technique. CareBolus combines a nearly real-time 2D-FLASH (fast low angle shot) sequence for fluoroscopic triggering and a high-resolution 3D-FLASH with elliptical centric view order for the angiographic pulse sequence (6.0/2.16 ms [TR/TE], 30 degrees flip angle, 30.98 s acquisition time, 0.88 mm effective (interpolated) partition thickness and a 160 x 512 matrix). Intra-arterial digital subtraction angiography and CE-MRA studies were evaluated independently by four blinded readers. Internal carotid artery stenoses were graded according to the NASCET criteria. RESULTS: CE-MRA had an accuracy of 92.53%, a sensitivity of 95.64%, and a specificity of 90.39% for the identification of carotid artery stenoses > or = 70% (grade 3). Image quality for suppression of stationary tissue and venous contrast was good, but was reduced in five cases due to patient motion. CONCLUSION: The CareBolus technique is a useful non-invasive method for high-resolution imaging of the supra-aortic vessels because of its easy application and high sensitivity and specificity. Limitations can occur in non-compliant patients due to motion artifacts during the measurement time.

Adult↗

Reduced reactivation rate in mutant CuZnSOD and progression rate of amyotrophic lateral sclerosis.

Mutations in the SOD1 gene are associated with familial amyotrophic lateral sclerosis (fALS). The mechanisms by which these mutations lead to anterior horn cell loss are unknown, however, increased binding of Hsps on the demetallated mutant SOD1 has been described which would make the HSPs unavailable for other purposes, and reduce the SOD1 concentration in mitochondria, thereby creating a proapoptotic situation finally leading to motor neuron death. Here we report the recombinant expression of four human copper/zinc superoxide dismutase (CuZnSOD) variants, including the wild-type enzyme and mutant proteins associated with familial ALS. The bacterial expression level of soluble mutated proteins was influenced by the mutations leading to drastically reduced levels of soluble CuZnSOD. Simultaneously, increasing levels of insoluble and probably aggregated mutated CuZnSOD were identified in bacterial cell pellets. In addition, altered reactivation kinetics of the purified mutant apoproteins after expression in bacterial culture was shown. Biophysical and biochemical analysis showed that zinc incorporation is severely reduced in the CuZnSOD proteins associated with the most severely forms of fALS (A4V, G93A). These data indicate that a reduced holoenzyme formation rate of mutant enzymes may be a critical factor in the etiopathology of fALS.

Alanine↗

Leukoencephalopathy and chronic pancreatitis as concomitant manifestations of systemic lupus erythematosus related to anticardiolipin antibodies.

Symptoms of leukoencephalopathy led to hospital admission of a 59-year-old woman. In addition, a tumor of unknown nature in the pancreas was identified by abdominal ultrasound and CT scan. Following explorative laparotomy and pancreas tail resection, histopathologic analysis revealed a pancreatic pseudotumor with chronic fibrotic pancreatitis. Systemic lupus erythematosus (SLE) was diagnosed due to the presence of antinuclear antibodies (ANA) in serum, antiphospholipid antibodies, and involvement of the central nervous system. Leukoencephalopathy related to anticardiolipin antibodies in serum is a known but rare manifestation of SLE. The concomitant occurrence of chronic pancreatitis can be caused by the development of SLE-induced vasculitis in the pancreas. Subsequent complications of pancreatitis are responsible for the critical, life-threatening state of these patients and may be prevented by early identification of anticardiolipin antibodies and therapy for SLE.

Aged↗

[Evaluation of a hemostatic device with percutaneous collagen application (VasoSeal) compared to a mechanical compression system (Compressar) after transfemoral catheterization of patients suffering from arterial occlusive disease].

PURPOSE: Comparison of the efficacy of VasoSeal and a mechanical compression system (Compressar) for percutaneous hemostasis after femoral arterial catheterization of patients with arterial occlusive disease. MATERIALS AND METHODS: 60 patients underwent either diagnostic angiography or interventional procedures. The level of anticoagulation, blood pressure, and activation clotting time were recorded, and the time to hemostasis after sheath removal was measured. VasoSeal application was considered "successful" if the compression time was less than two minutes. On the subsequent day as well as 4 months later, color coded Doppler ultrasound was performed to register treatment success and potential (late) complications. RESULTS: 57 patients qualified for inclusion in this study. In 21 of the 26 patients who underwent the procedure with the VasoSeal, immediate hemostasis was achieved within 1.75 minutes. In all 31 patients who had the Compressar applied, hemostasis was successful with a mean compression time of 17.4 minutes. Thus, VasoSeal significantly reduced hemostasis time irrespective of anticoagulation status, but it had a much higher incidence of minor local complications (bleeding, hematoma) compared to the control group (34.6 % vs. 5.8 %). The technical success was lower with VasoSeal than with Compressar (81 % vs. 100 %). Both groups had no severe or late complications. CONCLUSION: According to our results, VasoSeal does not provide a suitable alternative compared to the effective, safe and cheap application of Compressar as a hemostatic device.

Adult↗

Selective intraarterial fibrinolysis of acute central retinal artery occlusion.

PURPOSE: To evaluate the outcome of our patients with central retinal artery occlusion after local fibrinolysis and to compare these data with results reported in the literature. MATERIAL AND METHODS: Over a period of 7 years, 22 patients (11 male, 11 female, mean age 64.6 +/- 12.1 years) were treated with super-selective local fibrinolysis. In 1 case, treatment was carried out via the maxillary-ophthalmic anastomoses due to preexisting occlusion of the ipsilateral internal carotid artery. The latency period from the onset of symptoms to the beginning of therapy was 7.6 +/- 1.8 h. Urokinase was used in 7 cases (300,000-1.1 million units) and recombinant tissue plasminogen activator (20-40 mg) was applied in 15 patients. Visual acuity and fundus were examined before and after treatment. RESULTS: One patient (1/22 = 4.6%) recovered completely and regained a visual acuity of 20/20. Six patients (6/22 = 27.3%) showed a marked improvement with a range of visual outcome from 20/800 to 20/320. In 2 cases (2/22 = 9.1%) only a slight improvement was observed, with a visual outcome allowing detection of hand movements. In 13 cases (13/22 = 59.1%) no change in visual acuity as a result of treatment was observed. In 2/22 cases (9.2%) reversible neurological side-effects occurred, in 1 case suffered a stroke, and in another case intracerebral bleeding was observed. CONCLUSION: In our study, the recovery of visual acuity and the complication rate were not as positive as reported in the literature.

Acute Disease↗

Bolus-chasing contrast-enhanced 3D MRA of the lower extremity. Comparison with intraarterial DSA.

PURPOSE: To evaluate step-table 3D contrast-enhanced (CE) MRA with bolus chasing for the detection and grading of stenoses in patients with peripheral vascular disease (PVD) of the lower extremities. MATERIAL AND METHODS: Fifty patients were studied by step-table bolus-chasing 3D-CE-MRA and i.a. DSA within 24 h. After determination of the individual circulation time, CE-MRA was performed during power injection of 40 ml of Gd-DTPA. To cover the whole range between the renal arteries and the feet with three slab locations, the scanner table was manually advanced twice for 350 mm. Total imaging time was 1 min 23 s. The degree of stenosis and image quality of the images were evaluated by 2 observers. In addition, a treatment plan was established based on the 3D-CE-MRA and DSA investigations. RESULTS: In 44 of 50 patients (88%), the visualization of the arterial tree from the renal arteries to the foot was possible. Forty-six of 50 patients (92%) had good or very good image quality. In the calf, 3D-CE-MRA was superior to DSA in 6 patients. For the detection of stenosis >50%, sensitivity was 99.5%, specificity 98.8%, positive predictive value 95.6% and the negative predictive value 99.8%. Cohen's kappa for 3D-CE-MRA vs. DSA was 0.926; for interobserver agreement it was 0.96. CONCLUSION: Bolus-chasing 3D-CE-MRA with manual table movement is a simple, robust and easy to perform technique which provides high quality angiograms of the lower extremity arterial system and is comparable to, i.a., DSA for the diagnosis of PVD.

Adult↗

[Extracorporeal lung support and endovascular stent in traumatic aortic rupture and severe lung failure].

Blunt thoracic injury in association with aortic rupture represents a life-threatening situation. Surgical repair used to be the preferred method of treatment. Because most patients are multiple trauma patients including head injuries, bone fractures and respiratory failure, urgent surgical procedures portend excessively high morbidity and mortality rates. Delay in operative management bears the risk of exsanguinating hemorrhage, secondary complications, prolonged hospital stay with increased costs. We present here an alternative treatment protocol including pumpless extracorporal lung assist and endovascular aortic stent graft placement in a 20-year old traffic accident victim. This procedure may be an especially useful treatment option in managing patients with complex lung and aortic pathology primarily not suitable for transportation or surgery.

Adult↗

[Contrast-enhanced MR angiography in the routine work-up of the lower extremity arteries].

PURPOSE: Prospective evaluation of the effectiveness of contrast-enhanced moving-table magnetic resonance angiography (CE-MRA) as the sole routine tool for the diagnosis of peripheral arterial occlusive disease and determination whether it can replace catheter arteriography. SUBJECTS AND METHODS: In a time period of 23 weeks, 100 consecutive patients were evaluated. A total of 112 contrast-enhanced moving-table MR angiograms were performed at 1.5 Tesla. A dedicated vascular coil system was used. It was evaluated in which cases MR angiography was sufficient to determine the treatment plan and in which cases limited quality required additional examinations. RESULTS: In 93.75 % (105/112) of all examinations, the treatment plan was determined by MRA as the sole diagnostic tool. Twenty-two patients underwent surgery or percutaneous angioplasty based on MRA findings. Additional examinations due to impaired quality were performed in seven (6.25 %) cases: two MR angiographies of the pelvic arteries, one MR angiography of the calf, and four selective arteriographies because of venous overlay at the calf. CONCLUSION: Contrast-enhanced MR angiography can take the place of catheter angiography in the routine work-up of patients with peripheral arterial occlusive disease. Further assessment might be necessary in five to ten percent of the cases when the diagnostic quality is inadequate, mostly due to venous overlay in the lower leg.

Adult↗

[Percutaneous therapy of inoperable biliary stenoses and occlusions with a new self-expanding nitinol stent (SMART)].

OBJECTIVE: To evaluate the treatment of malignant biliary stenoses and occlusions using a new stent. METHODS: In a prospective study, 25 patients with malignant obstructive jaundice were treated with SMART(R) stents. The handling and the quality of stent expansion were documented. Stent function was assessed 2 - 4 days after intervention by cholangiography and laboratory tests. A follow-up was performed three months, after stent placement. RESULTS: All lesions were treated successfully, with a total of 35 stents implanted. In 14 patients a further balloon dilatation was performed after stent placement (8 - 10 mm diameter/ 40 - 80 mm length). The mean serum bilirubin level decreased significantly from 11.6 mg/dl to 4.6 mg/dl after intervention (p < 0.05). The follow-up showed a mean serum bilirubin level at 4.0 mg/dl. In 4 cases (16 %) a further intervention (PTCD or stent) was performed. Six patients died due to tumor progression. The stents proved to be patent in 79 % (n = 15) of patients alive at the time of follow-up. CONCLUSIONS: Placement of the SMART stent for the therapy of malignant biliary lesions yields good technical and clinical results.

Aged↗

Evaluation of arterial bypass grafts of the pelvic and lower extremities with gadolinium-enhanced magnetic resonance angiography: comparison with digital subtraction angiography.

RATIONALE AND OBJECTIVES: The aim of this study was to compare contrast-enhanced magnetic resonance angiography (CE MRA) with digital subtraction angiography (DSA) in the assessment of patency and stenoses in bypass grafts. METHODS: Fifteen patients were examined with both CE MRA and DSA. Fifteen bypass grafts were evaluated by four readers for potential stenosis in five locations. The stenoses were classified in five types: 1 (0% to 24% stenosis), 2 (25% to 49%), 3 (50% to 74%), 4 (75% to 99%), and 5 (occlusion). RESULTS: Using both techniques, 70 of 75 evaluated locations (93.3%) were classified identically. This included six stenoses < 50% and six stenoses > 50%, respectively. Four of five overestimations of stenoses were scaled in DSA as stenoses type 1. One stenosis was categorized as type 3 in DSA. Sensitivity for CE MRA for detecting stenoses >or= 25% was 100% and the specificity 90%. Interobserver agreement for all evaluations was 0.77 (Spearman rank correlation test). CONCLUSION: In the assessment of low-grade stenosis in bypass grafts, CE MRA overestimates stenoses slightly but yields good results in comparison with DSA.

Angiography, Digital Subtraction↗

Superoxide dismutase mutations of familial amyotrophic lateral sclerosis and the oxidative inactivation of calcineurin.

Approximately 10% of all familial cases of amyotrophic lateral sclerosis (fALS) are linked to mutations in the SOD1 gene, which encodes the copper/zinc superoxide dismutase (CuZnSOD). Recently, wild-type CuZnSOD was shown to protect calcineurin, a calcium/calmodulin-regulated phosphoprotein phosphatase, from inactivation by reactive oxygen species. We asked whether the protective effect of CuZnSOD on calcineurin is affected by mutations associated with fALS. For this, we monitored calcineurin activity in the presence of mutant and wild-type SOD. We found that the degree of protection against inactivation of calcineurin by different SOD mutants correlates with the severity of the phenotype associated with the different mutations, suggesting a potential role for calcineurin-SOD1 interaction in the etiology of fALS.

Amyotrophic Lateral Sclerosis↗

A novel serine protease inhibition motif involving a multi-centered short hydrogen bonding network at the active site.

We describe a new serine protease inhibition motif in which binding is mediated by a cluster of very short hydrogen bonds (<2.3 A) at the active site. This protease-inhibitor binding paradigm is observed at high resolution in a large set of crystal structures of trypsin, thrombin, and urokinase-type plasminogen activator (uPA) bound with a series of small molecule inhibitors (2-(2-phenol)indoles and 2-(2-phenol)benzimidazoles). In each complex there are eight enzyme-inhibitor or enzyme-water-inhibitor hydrogen bonds at the active site, three of which are very short. These short hydrogen bonds connect a triangle of oxygen atoms comprising O(gamma)(Ser195), a water molecule co-bound in the oxyanion hole (H(2)O(oxy)), and the phenolate oxygen atom of the inhibitor (O6'). Two of the other hydrogen bonds between the inhibitor and active site of the trypsin and uPA complexes become short in the thrombin counterparts, extending the three-centered short hydrogen-bonding array into a tetrahedral array of atoms (three oxygen and one nitrogen) involved in short hydrogen bonds. In the uPA complexes, the extensive hydrogen-bonding interactions at the active site prevent the inhibitor S1 amidine from forming direct hydrogen bonds with Asp189 because the S1 site is deeper in uPA than in trypsin or thrombin. Ionization equilibria at the active site associated with inhibitor binding are probed through determination and comparison of structures over a wide range of pH (3.5 to 11.4) of thrombin complexes and of trypsin complexes in three different crystal forms. The high-pH trypsin-inhibitor structures suggest that His57 is protonated at pH values as high as 9.5. The pH-dependent inhibition of trypsin, thrombin, uPA and factor Xa by 2-(2-phenol)benzimidazole analogs in which the pK(a) of the phenol group is modulated is shown to be consistent with a binding process involving ionization of both the inhibitor and the enzyme. These data further suggest that the pK(a) of His57 of each protease in the unbound state in solution is about the same, approximately 6.8. By comparing inhibition constants (K(i) values), inhibitor solubilities, inhibitor conformational energies and corresponding structures of short and normal hydrogen bond-mediated complexes, we have estimated the contribution of the short hydrogen bond networks to inhibitor affinity ( approximately 1.7 kcal/mol). The structures and K(i) values associated with the short hydrogen-bonding motif are compared with those corresponding to an alternate, Zn(2+)-mediated inhibition motif at the active site. Structural differences among apo-enzymes, enzyme-inhibitor and enzyme-inhibitor-Zn(2+) complexes are discussed in the context of affinity determinants, selectivity development, and structure-based inhibitor design.

Amino Acid Motifs↗

On the heating of linear conductive structures as guide wires and catheters in interventional MRI.

The interest in performing vascular interventions under magnetic resonance (MR) guidance has initiated the evaluation of the potential hazard of long conductive wires and catheters. The objective of this work is to present a simple analytical approach to address this concern and to demonstrate the agreement with experimental results. The first hypothesis is that a long conductive structure couples with the electric field of the radio frequency (RF) transmit coil. The second hypothesis is that this coupling induces high voltages near the wire ends. These voltages can cause tissue heating due to induced currents. The experimental results show an increase in coupling when moving a guide wire toward the wall of an RF transmit coil, documented with a temperature increase of a saline solution in close proximity to the tip of the guide wire. The coupling of the wire not only presents a potential hazard to the patient, but also interferes with the visualization of the wire. A safe alternative would be the use of nonconducting guide wires. J. Magn. Reson. Imaging 2001;13:105-114.

Catheterization↗

[The endoleak problem in endoluminal therapy].

Endovascular treatment of aortic aneurysms with stent grafts was performed increasingly in recent years. The most frequent complication after endovascular therapy of aortic aneurysms is an endoleak. In case of a persistent endoleak, diameter of the aneurysm is increasing with a high risk of aneurysm ruptur. Diagnostic tools are spiral computed tomography and angiography. Spiral computed tomography is the most sensitive method for the diagnosis of an endoleak ad should be performed with a biphasic acquisition. In- and outflow of sidebranches can be identified correctly with selective angiography in 86%. Perigraft endoleaks should be treated in any case. Patent side branches generally are observed over a period of 6 months. After 6 months approximately half of these endoleaks are thrombosed. Is there an increasing of the diameter of the aneurysm or any changing in the morphology of the aneurysm there is an indication for embolisation of these sidebranches of the aneurysmal sac. Preinterventional embolisation of patent sidebranches is under discussion. Type I endoleaks can be managed by additional stent-graft implantation or coil embolisation. In case of type II endoleaks in- ad outflow vessels should be embolised with coils. Therapy of type III endoleak is performed mostly by additional stent-graft placement. The total incidence of secondary interventions in the Eurostar-study was nearly 10% per year.

Aortic Aneurysm, Abdominal↗