Search PubMed⌕ Search

Biomedical subjects

J H Kuiper

Publications and source records attributed to J H Kuiper.

23 records · Page 2Linked to original sources

Dynamisation of tibial fractures.

We studied the effect of 'dynamisation' on tibial fractures in six patients treated by the Dynamic Axial Fixator. In the early stages, peak cyclic movement at two to four weeks averaged 0.75 mm (0.19 to 1.02) on the medial side of the bone and 0.86 mm (0.21 to 1.25) on the lateral side. The amount of movement correlated with the applied load and the fracture stiffness. After unlocking the fixator column at six weeks, progressive closure of the gap averaged 1.3 mm (0.1 to 3.5). Cyclic movement is produced by early weight-bearing with the fixator column locked. Progressive closure occurs after unlocking the column, and is often associated with a reduction in cyclic movements. The effects of dynamisation on movement at the fracture site should be defined separately, in terms of cyclic movement and of progressive closure.

Adult↗

Stress distribution around dental implants: influence of superstructure, length of implants, and height of mandible.

The stress distribution around dental implants was investigated by use of a two-dimensional model of the mandible with two implants. A vertical load of 100 N was imposed on abutments or the bar connection. The stress was calculated for a number of superstructures under different loading conditions with the help of the finite element method. The length of the implants and the height of the mandible were also varied. A model with solitary abutments showed a more uniform distribution of the stress when compared with a model with connected abutments. The largest compressive stress was also less in the model without the bar. Using shorter implants did not have a large influence on the stress around the implants. When the height of the mandible was reduced, a substantially larger stress was found in the bone around the implants because of a larger overall deformation of the lower jaw.

Bite Force↗

Articular contact in a three-dimensional model of the knee.

This study is aimed at the analysis of articular contact in a three-dimensional mathematical model of the human knee-joint. In particular the effect of articular contact on the passive motion characteristics is assessed in relation to experimentally obtained joint kinematics. Two basically different mathematical contact descriptions were compared for this purpose. One description was for rigid contact and one for deformable contact. The description of deformable contact is based on a simplified theory for contact of a thin elastic layer on a rigid foundation. The articular cartilage was described either as a linear elastic material or as a non-linear elastic material. The contact descriptions were introduced in a mathematical model of the knee. The locations of the ligament insertions and the geometry of the articular surfaces were obtained from a joint specimen of which experimentally determined kinematic data were available, and were used as input for the model. The ligaments were described by non-linear elastic line elements. The mechanical properties of the ligaments and the articular cartilage were derived from literature data. Parametric model evaluations showed that, relative to rigid articular contact, the incorporation of deformable contact did not alter the motion characteristics in a qualitative sense, and that the quantitative changes were small. Variation of the elasticity of the elastic layer revealed that decreasing the surface stiffness caused the ligaments to relax and, as a consequence, increased the joint laxity, particularly for axial rotation. The difference between the linear and the non-linear deformable contact in the knee model was very small for moderate loading conditions. The motion characteristics simulated with the knee model compared very well with the experiments. It is concluded that for simulation of the passive motion characteristics of the knee, the simplified description for contact of a thin linear elastic layer on a rigid foundation is a valid approach when aiming at the study of the motion characteristics for moderate loading conditions. With deformable contact in the knee model, geometric conformity between the surfaces can be modelled as opposed to rigid contact which assumed only point contact.

Elasticity↗

Long-term urban trends in developing countries: some further econometric results.

"Urban trends in developing countries have been studied in broad terms only, which has led to improbable projections for the future. In this paper, a two-equation model has been drawn up and tested by advanced econometric methods to pinpoint the role of explanatory factors and to discover possible trend reversals. Results on both scores have been positive."

Demography↗