Tension-band wiring of transverse fractures of patella. The effect of site of wire twists and orientation of stainless steel wire loop: a biomechanical investigation.

Tension-band wiring is commonly used to treat transverse patella fractures. The most common configuration has parallel Kirschner (K) wires and a stainless steel wire loop placed in a vertically oriented figure of eight. Early mobilisation is important but can cause detrimental displacement at the fracture site. A wooden model of a transversely fractured patella was used to compare different fixation constructs. The fracture was fixed using two K wires and a stainless steel wire loop. One or two wire twists were used, placed either arbitrarily or at corners of the loop. The loop was oriented either vertically or horizontally. Interfragmentary compression at the point of wire breakage and permanent displacement on cyclic loading was measured for each construct. Placement of the figure of eight in a horizontal orientation with two wire twists at the corner improved interfragmentary compression by 63% (p<0.05, Tukey post hoc test). On cyclic loading, all constructs with vertical figure of eight but none with a horizontal construct failed (p=0.01; Fisher's exact test). Permanent fracture displacement after cyclic loading was 67% lower with horizontal figure of eight constructs (p<0.05; t test). Placing wire twists at the corner and a horizontal placement of figure of eight improves stability of the construct.

Biomechanical Phenomena↗

Computational simulation of fracture healing: influence of interfragmentary movement on the callus growth.

Bone fractures heal through a complex process involving several cellular events. This healing process can serve to study factors that control tissue growth and differentiation from mesenchymal stem cells. The mechanical environment at the fracture site is one of the factors influencing the healing process and controls size and differentiation patterns in the newly formed tissue. Mathematical models can be useful to unravel the complex relation between mechanical environment and tissue formation. In this study, we present a mathematical model that predicts tissue growth and differentiation patterns from local mechanical signals. Our aim was to investigate whether mechanical stimuli, through their influence on stem cell proliferation and chondrocyte hypertrophy, predict characteristic features of callus size and geometry. We found that the model predicted several geometric features of fracture calluses. For instance, callus size was predicted to increase with increasing movement. Also, increases in size were predicted to occur through increase in callus diameter but not callus length. These features agree with experimental observations. In addition, spatial and temporal tissue differentiation patterns were in qualitative agreement with well-known experimental results. We therefore conclude that local mechanical signals can probably explain the shape and size of fracture calluses.

Bony Callus↗

A 3D computational simulation of fracture callus formation: influence of the stiffness of the external fixator.

The stiffness of the external fixation highly influences the fracture healing pattern. In this work we study this aspect by means of a finite element model of a simple transverse mid-diaphyseal fracture of an ovine metatarsus fixed with a bilateral external fixator. In order to simulate the regenerative process, a previously developed mechanobiological model of bone fracture healing was implemented in three dimensions. This model is able to simulate tissue differentiation, bone regeneration, and callus growth. A physiological load of 500 N was applied and three different stiffnesses of the external fixator were simulated (2300, 1725, and 1150 N/mm). The interfragmentary strain and load sharing mechanism between bone and the external fixator were compared to those recorded in previous experimental works. The effects of the stiffness on the callus shape and tissue distributions in the fracture site were also analyzed. We predicted that a lower stiffness of the fixator delays fracture healing and causes a larger callus, in correspondence to well-documented clinical observations.

Animals↗

Reconstruction of femoral defects in revision hip surgery: risk of fracture and stem migration after impaction bone grafting.

The use of impaction bone grafting during revision arthroplasty of the hip in the presence of cortical defects has a high risk of post-operative fracture. Our laboratory study addressed the effect of extramedullary augmentation and length of femoral stem on the initial stability of the prosthesis and the risk of fracture. Cortical defects in plastic femora were repaired using either surgical mesh without extramedullary augmentation, mesh with a strut graft or mesh with a plate. After bone impaction, standard or long-stem Exeter prostheses were inserted, which were tested by cyclical loading while measuring defect strain and migration of the stem. Compared with standard stems without extramedullary augmentation, defect strains were 31% lower with longer stems, 43% lower with a plate and 50% lower with a strut graft. Combining extramedullary augmentation with a long stem showed little additional benefit (p = 0.67). The type of repair did not affect the initial stability. Our results support the use of impaction bone grafting and extramedullary augmentation of diaphyseal defects after mesh containment.

Arthroplasty, Replacement, Hip↗

Factors affecting the cohesion of impaction bone graft.

The role of bone-graft extenders in impaction revision surgery is becoming increasingly important. Tricalcium phosphate and hydroxyapatite have been shown to be both biocompatible and osteoconductive, yet many surgeons remain reluctant to use them. The difficulty in handling bone-graft extenders can be partly alleviated by using porous particles and adding clotted blood. In an in vitro model we measured the cohesive properties of various impaction graft mixes. Several factors were evaluated including the use of pure bone graft compared with mixes with extender, washing the bone and the addition of clotted blood. Our findings showed that pure allograft bone particles had significantly higher cohesion than when mixed with extender (p < 0.001). Washing had no effect on cohesion. The addition of clotted blood significantly increased the cohesion of both pure bone (p < 0.019) and mixes with pure bone and with porous graft extender (p < 0.044).

Biocompatible Materials↗

Biomechanical evaluation of a new composite bioresorbable screw.

A new bioresorbable composite cannulated screw has been developed for small bone fracture fixation. The LG ("Little Grafter") screw is manufactured from Biosteon, which is a composite of poly L-lactic acid and hydroxyapatite. This study aimed to compare interfragmentary compression generated by this new screw with conventional metal screws commonly used in scaphoid fracture fixation. Four small metallic screws were compared with the LG screw, using a bone model produced from rigid polyurethane foam. The screws included the Acutrak, Asnis III, Herbert and Herbert-Whipple screws. The mean maximum compression forces for the LG screw, the Asnis and the Acutrak were comparable (LG 32.3 N, Asnis 32.8 N, Acutrak 38.3 N), whereas those using the Herbert and the Herbert-Whipple screw were significantly lower (Herbert 21.8 N, Herbert-Whipple 19.9 N). The bioresorbable LG screw has been shown to have good compressive properties compared to commonly used small bone fragment compression screws.

Absorbable Implants↗

Influence of fracture gap size on the pattern of long bone healing: a computational study.

Following fractures, bones restore their original structural integrity through a complex process in which several cellular events are involved. Among other factors, this process is highly influenced by the mechanical environment of the fracture site. In this study, we present a mathematical model to simulate the effect of mechanical stimuli on most of the cellular processes that occur during fracture healing, namely proliferation, migration and differentiation. On the basis of these three processes, the model then simulates the evolution of geometry, distributions of cell types and elastic properties inside a healing fracture. The three processes were implemented in a Finite Element code as a combination of three coupled analysis stages: a biphasic, a diffusion and a thermoelastic step. We tested the mechano-biological regulatory model thus created by simulating the healing patterns of fractures with different gap sizes and different mechanical stimuli. The callus geometry, tissue differentiation patterns and fracture stiffness predicted by the model were similar to experimental observations for every analysed situation.

Animals↗

Influence of core suture material and peripheral repair technique on the strength of Kessler flexor tendon repair.

The purpose of our study was to determine the most favourable combination of core suture material and peripheral repair technique for Kessler tendon repair. Thirty freshly thawed pig flexor tendons were repaired by a Kessler technique, either with braided polyester or monofilament nylon suture. A peripheral augmentation was done using one of the three techniques-running, cross-stitch and Halsted. All repairs were tested by cyclic loading, followed by load-to-failure. During cyclic loading six of the 15 tendons with a nylon core failed, but none with a braided polyester core. Irrespective of peripheral technique, the monofilament nylon core suture allowed early central cyclic gapping, resulting in failure of the repair. During load-to-failure testing, the running stitch proved weakest and the cross-stitch repair toughest.

Analysis of Variance↗

The prediction of stress fractures using a 'stressed volume' concept.

This paper addresses an anomaly which exists in the current literature regarding stress fractures. Analysis of the data on fatigue strength of bone samples in vitro would conclude that these fractures should never occur at the strain levels known to occur in vivo. This anomaly can be resolved by including in the analysis the effect of stressed volume, whereby larger volumes of material are expected to have worse fatigue properties. A Weibull analysis was used to predict the probability of failure, Pf; this was an upper-bound prediction because it did not include the effects of remodelling and adaptation. Combining this analysis with a finite element model of the human tibia, we predicted a Pf value of 21% after five weeks of strenuous exercise, which is comparable with reported incidences in military personnel. The high incidence of stress fractures in the cannon bone of racehorses could also be predicted (Pf = 62%, compared to 70% experimentally). The approach can be used to investigate the effect of variables in the exercise regime such as the distance run per day and the use of improved footwear. It can also predict the increased risk of stress fractures in elderly people. The results suggest certain simple rules which may be of clinical value in designing exercise regimes and in understanding the risk factors for this type of injury.

Animals↗

Fracture stiffness in callotasis determined by dual-energy X-ray absorptiometry scanning.

Assessing healing after distraction limb lengthening is essential to manage patients undergoing callotasis for leg lengthening or bone transport. Direct measurement of fracture stiffness can assess healing but the equipment may not be available. In addition, it requires removal of the fixator, which may be complicated for ring fixators. The present study investigates whether an equivalent measure of healing can be based on the mineral density pattern from dual-energy X-ray absorptiometry (DXA) scans. Nine consecutive patients undergoing callotasis were studied. Bending stiffness of the distraction segment was measured and DXA scans were performed regularly starting 6 weeks after completing distraction. In all, 23 simultaneous readings of bending stiffness and DXA scans were obtained. All density patterns showed a distinct minimum value of bone mineral density. We found a high and significant correlation between fracture bending stiffness and the square of the total mineral content at the location of minimum bone density (r2 = 0.77, P < 0.001). We conclude that DXA scans can be used reliably and effectively to determine fracture bending stiffness, valuable for determining both time of frame removal and delay in union.

Absorptiometry, Photon↗

Acetabular morphology and resurfacing design.

The bony surfaces of 18 archaeological hemipelves were scanned using a 3D laser surface scanner and CyDir software on a Silicon Graphics workstation. The acetabular area was selected and point data from the approximately spherical bone surface saved. These data were input to a MATLAB routine that calculated the radius and centre of the best-fit sphere. The goodness of fit was estimated using the mean and standard deviation of the distance of the bone surface points from the sphere surface. Eight points, at approximately equal distances around the acetabular rim, were selected with reference to bony landmarks. A plane containing three of these points served as an orientation reference plane. The vectors joining the eight rim points to the centre of the best-fit sphere were found. The angles between these vectors and the normal to the reference plane were calculated. Paired angles were summed to give the angle subtended by the acetabular rim in four directions. The overall mean angle was 158 degrees (range of mean angles 145 degrees -173 degrees ). The largest individual angles, some exceeding 180 degrees, were in the superior-inferior direction, while the mean angle in the anterior-posterior direction, i.e. that controlling flexion-extension, was 152 degrees. Males had larger subtended angles than females, although the difference was not statistically significant. Simulated reaming increased all angles by approximately 10 degrees. The subtended angles are important parameters in the design of the acetabular component of a hip replacement and particularly important in resurfacing hip replacement when the volume available is tightly constrained.

Acetabulum↗

Malunion in the lower limb. A nomogram to predict the effects of osteotomy.

Nomograms derived from mathematical analysis indicate that the level of malunion is the most important determinant of changes in the moment arm of the knee, the plane of the ankle and alterations in limb length. Testing in five patients undergoing reconstruction showed a mean error of postoperative limb length of 2.2 mm (SD 0.8 mm), knee moment arm of 4.7 mm (SD 3.3 mm) and ankle angle of 2.6 degrees (SD 2.3 degrees). These nomograms provide the information required when assessing whether a particular degree of angulation may be accepted.

Algorithms↗

Mathematical optimization of elastic properties: application to cementless hip stem design.

The designer of a cementless hip stem in total hip replacement must find a balance between two conflicting demands. On the one hand, a stiff stem shields the surrounding bone from mechanical loading (stress shielding), which may lead to bone loss, particularly around the proximal part of the stem. Reducing the stem stiffness decreases the amount of stress shielding and hence the amount of bone loss. However, this measure inevitably promotes higher proximal interface stresses and thereby increases the risk of proximal interface failure. The designer's task therefore is to optimize the stem stiffness in order to find the best compromise in the conflict. Yet, a better compromise might be found when the stem material was nonhomogeneous, in other words when an arbitrary distribution of the elastic properties inside the stem was allowed. The number of conceivable designs would increase enormously, making the designer's task almost impossible. In the present paper, we develop a numerical design optimization method to determine the optimal stiffness characteristics for a hip stem. A finite element program is coupled with a numerical optimization method, thus producing a design optimization scheme. The scheme minimizes the probability for interface failure while limiting the amount of bone loss, by adapting the parameters describing the nonhomogeneous elastic modulus distribution. As an example, a simplified model of a hip stem is made, whose modulus distribution is optimized. Assuming equal long-term bone loss, the maximum interface stress can be reduced by over 50 percent when compared to a homogeneous flexible stem, thus demonstrating the value of the new approach.

Elasticity↗

The predictive value of stress shielding for quantification of adaptive bone resorption around hip replacements.

The presence of a femoral hip stem changes local mechanical signals inside the surrounding bone. In this study we examined the hypothesis that the eventual loss of bone can be estimated from the initial patterns of elastic energy deviation, as determined in FE models of the intact bone and the operated femur. For that purpose two hypothetical relations between elastic energy reduction and resorption were investigated. Their estimates of bone loss were compared to the results of iterative computer simulations. Two kinds of FE model were used, and in each stem stiffness and remodeling threshold (a measure of "biological reactivity") were varied. Provided that reasonable values of the remodeling threshold are assumed and that the stem is firmly bonded to the bone, we found that the difference between direct estimates and simulation models was 4 percent of bone loss. It is therefore concluded that initial patterns of elastic energy deviation give a reasonable indication of expected bone loss.

Adaptation, Physiological↗

Friction and stem stiffness affect dynamic interface motion in total hip replacement.

Large cyclic movements between the femoral stem and bone during the first weeks after total hip arthroplasty may hamper bone ingrowth and adversely affect the eventual success of the arthroplasty. Little is known, however, about the magnitude of the motions and its relationship to design and surgical factors. A two-dimensional finite element model of a cementless prosthesis inserted into the proximal femur was constructed to study the effects of two mechanical variables--the stiffness of the implant and the coefficient of friction between bone and implant--on the magnitude of the motions. We investigated the influences of these variables on the subsidence of the prosthesis, the magnitudes of the cyclic motions, and the level of the interface stresses. The presence of friction reduced cyclic motions by about 85% compared with a frictionless interface. Once friction was assumed, varying the coefficient of friction had little effect. The effect of friction on the interface stress state and gross subsidence of the prosthesis was not as great as on cyclic motion. Implant stiffness also affected the magnitudes and distributions of the cyclic motions along the interface. A flexible stem generated motions about three to four times larger proximally than those of a stiff stem, which generated larger motions distally. The influence of stem stiffness on interface stresses and prosthetic subsidence was less than on cyclic motion. The location of the peak shear stresses at the interface around a bonded prosthesis corresponded to the location where cyclic interface motion was maximal for an unbonded prosthesis. However, no direct relationship was found between the magnitudes of peak stresses and the amplitudes of cyclic motions.

Elasticity↗

A comparison of finite element codes for the solution of biphasic poroelastic problems.

The extent to which three finite element codes can solve problems in biphasic poroelasticity is examined. Both linear and non-linear (that is where the permeability of the material is a function of deformation) formulations are studied using the standard confined compression problem as an example. The results are compared, where possible, to the results of Spilker, Suh and Mow who first presented a solution to this problem for cartilage. The agreement is excellent for the linear case. For the non-linear case, the solutions do differ slightly; however, the difference would not appear to be significant.

Biomechanical Phenomena↗

Stiffness measurements to assess healing during leg lengthening. A preliminary report.

We describe a technique for measuring the stiffness of regenerate bone after leg lengthening. This allows early identification of slow healing by reference to normal patterns. We determined the time of removal of the fixator from clinical and radiological information independent of the stiffness result. In a series of 30 leg lengthenings there were no refractures when the tibial stiffness had reached 15 Nm/degree or the femoral stiffness 20 Nm/degree. Three refractures occurred at lower stiffness values. The technique is simple to perform, will allow a reduction in plain radiography and is recommended for routine postoperative management.

Adolescent↗