Search PubMed⌕ Search

Biomedical subjects

J Geier

Publications and source records attributed to J Geier.

At least 19 recordsLinked to original sources

Late reactions to the patch-test preparations para-phenylenediamine and epoxy resin: a prospective multicentre investigation of the German Contact Dermatitis Research Group.

BACKGROUND: Late patch-test reactions, developing at day (D) 7 or later have been described for several allergens. Late reactions may reflect patch-test sensitization. Para-phenylenediamine (PPD) and epoxy resins (ER) are potent allergens and therefore may potentially induce patch-test sensitization. Up to now, there has been no prospective study on the frequency of late reactions in routine patch testing with these allergens. OBJECTIVES: To assess the frequency of late reactions to PPD and ER. PATIENTS/METHODS: In 1748 patients PPD (PPD-base, 1% pet.) and ER [based on diglycidylether of bisphenol A (DGEBA, 1% pet.)], and in 812 patients, nickel sulphate (5% pet.) were removed from the test panel of the standard series and applied on the medial side of the upper arm. Patch-test occlusion time was 24 h in 588 (PPD and ER) and 241 patients (nickel sulphate), respectively, and 48 h in 1160 (PPD and ER) and 571 (nickel sulphate) patients, respectively. Patch tests were read on D1-3 and D2-3, respectively; additional late readings were performed on D7, D14 and D21 after patch-test application. Patients who were not able to return for all scheduled late readings were telephoned on D7, D14 or D21, and questioned about a reaction at the test sites. Patients were instructed to perform daily self-examination from D4 onwards and to return immediately to the clinic if a reaction at the upper arm became visible. RESULTS: Data of 1428 patients (ER and PPD) and 638 patients (nickel) were evaluable. In 25 patients (1.8%), patch tests became positive not before D7, among them 21 reactions to PPD (1.5%) and four reactions to ER (0.3%). In five of seven patients, repeated patch tests with PPD disclosed patch-test sensitization as the cause of the late reaction. All late reactions, except for one, occurred in patients in whom patch tests were applied for 48 h. No late reactions were seen with nickel sulphate. CONCLUSIONS: PPD (1% pet.) elicited late reactions in 1.5% of routine patch tests, the majority of them probably being caused by patch-test sensitization. Therefore, the German Contact Dermatitis Research Group decided to remove PPD 1% pet. from the German standard series and to take efforts to optimize the patch-test conditions of PPD. One way to optimize PPD testing could be to reduce the exposure of PPD 1% to 24 h. Alternatively the patch-test concentration of PPD might be reduced.

Adolescent↗

A high-positive patch test load correlates with further positive patch test reactions irrespective of their location.

BACKGROUND: Patch testing is the standard clinical procedure to prove contact sensitization. It is a common practice to attach multiple patch tests at the same time. However, synchronous reactions to unrelated allergens may not be completely unassociated. If so, the reaction in a given test field might be influenced by other positive test reactions in a distance-related degree. This article analyses whether there is a distance-related effect of synchronous positive patch test reactions on the outcome of a target patch test. METHODS: Data collected from patients patch tested for diagnostic purposes with 15 standard allergens attached in a specific pattern between 1992 and 2004 in 20 centres in a Central European network were retrospectively evaluated. The association between the target patch test result (allergic vs negative reaction to the thiuram mix) and the number and cumulated strength of synchronous positive reactions (positive patch test load) to allergens placed in nearby or distant positions to the target patch was analysed by using logistic regression analysis. RESULTS: The likelihood of a positive reaction to thiuram mix significantly increased with an increasing synchronous positive patch test load generated by positive reactions to allergens unrelated to thiuram mix. The effect of allergens neighbouring the target allergen was not significantly stronger than that of allergens placed in distant positions. CONCLUSION: For the interpretation of patch test results, the potentially enhancing effects of a synchronous positive patch test load should be considered. The local distribution of the patches on the back is, however, not critical.

Dermatitis, Contact↗

Contact allergy to neomycin sulfate: results of a multifactorial analysis.

PURPOSE: To perform a comprehensive, multifactorial analysis of potential risk factors (demographic and clinical) for contact allergy to neomycin sulfate, a common adverse reaction resulting from the topical use of this drug; especially in some subgroups of the population. METHODS: Retrospective analysis of allergy test data of the Information Network of Departments of Dermatology (IVDK, www.ivdk.org) between 1998 and 2003, including all patients patch tested with a standard screening series because of suspected allergic contact dermatitis (ACD). As one outcome, a positive (allergic) test reaction to neomycin sulfate was considered. An alternative outcome included only those patients with a positive test to neomycin sulfate and a final diagnosis of ACD. The association between outcome and potential risk factors was analyzed with Poisson regression analysis, deriving prevalence ratios (PR) as risk estimates. RESULTS: Of the 47,559 patients tested, 2.5% had positive reactions to neomycin sulfate, while in 1.1% ACD was additionally diagnosed. The results of the multifactorial analysis indicated that the risk of both outcomes decreased slightly during the period covered; was higher among patients with leg dermatitis; varied significantly with age and increased progressively with the number of additional positive reactions to other standard series allergens. Cross-reactivity to other, selectively tested, aminoglycoside antibiotics was substantial (kappa = 0.67; 95%CI: 0.63-0.71) for framycetin sulfate, to low (kappa = 0.33; 95%CI: 0.27-0.37) for gentamicin sulfate. CONCLUSIONS: The prevalence of contact sensitization to neomycin sulfate was noteworthy among patients patch tested in the IVDK centers. Supplementing clinical epidemiology, neomycin contact allergy has been estimated to be relatively common even on the level of the unselected population (prevalence approx. 1%). Hence, the topical use of neomycin sulfate by patients should be carefully monitored, considering its potential to induce ACD, with emphasis on subgroups at risk.

Administration, Topical↗

[Evidence-based evaluation of the effect of Type IV Allergies on the reduction of fitness for work. Survey of occupational skin diseases].

Evidence-based guidelines about the distribution of type IV allergens of the European standard series in different professions and its occupational relevance are missing. Based on published data, epidemiological investigations, work related knowledge about industrial processes, and allergen specific properties, recommendations are given about the clinical impact in the working environment for the following allergens: acrylates/methacrylates, epoxy resins, dichromate, cobalt, nickel, formaldehyde, (chlor-)methylisothiazolone, p-phenylendiamine, colophony, thiurame, mercaptobenzothiazole, dithiocarbamate, n-isopropyl-n'-phenyl-p-phenylendiamine, fragrance mix, composite mix, and neomycinsulfate. These recommendations might improve the clearance rate and allergological evaluation of the occupational relevance of different delayed type sensitizations or allergens.

Allergens↗

[Patch testing with the DKG standard series 2001-2004. Results from the IVDK].

Patch testing is the standard procedure to detect contact sensitivity. The most frequent contact allergens are included in the standard series. We report on current trends regarding results obtained with the standard series from 2001-2004 in Germany, Austria (Graz, Vienna) and Switzerland (Basel). This analysis includes the frequency of the most common contact allergens and other aspects such as age and gender distribution and parameters of diagnostic quality such as reaction index and positivity ratio. Information on the most common contact allergens is updated.

Adult↗

Contact vitiligo following a strong patch test reaction to triglycidyl-p-aminophenol in an aircraft industry worker: case report and review of the literature.

Epoxy resin systems (ERSs) are a frequent cause of occupational allergic contact dermatitis. A 50-year-old patient developed eczematous skin lesions on the back of his hands, lower arms and eye lids, 2 months after he had started working in aircraft construction. Patch tests showed positive reactions at day 3 to nickel sulfate, epoxy resin based on diglycidyl ether of bisphenol F (DGEBF) and 1,4-butanediol diglycidyl ether (1,4-BDDGE). The chemical triglycidyl-p-aminophenol (TGPAP) applied at 1% and 0.1% induced the strongest (+++ positive) reaction. About 4 months after the patch test with TGPAP, the patient presented with 2 circular depigmented spots in the former TGPAP-patch test areas. Dermatohistopathology confirmed the diagnosis of contact vitiligo.

Aircraft↗

Simultaneous sodium lauryl sulphate testing improves the diagnostic validity of allergic patch tests. Results from a prospective multicentre study of the German Contact Dermatitis Research Group (Deutsche Kontaktallergie-Gruppe, DKG).

BACKGROUND: There is evidence that a higher skin susceptibility may induce nonspecific erythematous or weak positive reactions to contact allergens in patch testing. OBJECTIVES: To evaluate whether simultaneous application of sodium lauryl sulphate (SLS) along with diagnostic patch tests with contact allergens can provide information regarding skin irritability which may help to discriminate allergic from nonspecific irritant reactions to contact allergens. METHODS: Between July 2001 and June 2003, this prospective study collected patch test data of 5971 patients from 19 centres in Germany and Austria in the Information Network of Departments of Dermatology (IVDK). In addition to contact allergens (standard series and eight known 'problematic' allergens with a low reaction index and a high positivity ratio: 1,3-diphenylguanidine, amerchol L-101, benzalkonium chloride, benzoyl peroxide, cocamidopropyl betaine, octyl gallate, phenyl mercuric acetate and propylene glycol), patches with SLS 0.5% and 0.25% aq. were applied. Reactions to the allergens and to SLS were analysed at the IVDK data centre. The association between an erythematous or positive reaction to a certain allergen and an irritant reaction to SLS was assessed with logistic regression analysis, at the same time controlling for the influence of age and sex. RESULTS: Of the 29 allergens of the standard series, 23 and 21 gave a higher percentage of nonspecific erythematous reactions in patients with an irritant reaction to 0.25% and 0.5% SLS, respectively, in comparison with SLS-negative patients. All eight 'problematic' allergens gave an increased percentage of nonspecific erythematous reactions. Similarly, 22 and 21 allergens of the standard series gave a higher percentage of positive allergic reactions in patients with an irritant reaction to 0.25% and 0.5% SLS, respectively, and seven of the eight 'problematic' allergens gave a higher percentage of positive allergic reactions (exception: octyl gallate). For most allergens, the markers of skin reaction (reaction index and positivity ratio) were worse in SLS-positive patients. Differences were more pronounced when testing with SLS 0.25% than with SLS 0.5%. CONCLUSIONS: Because there is a convincing association between skin irritability (evaluated by SLS test) and the degree of skin reaction to contact allergens, the SLS test may help in deciding whether a doubtful erythematous or weakly 'positive' skin reaction should be interpreted as allergic or irritant.

Adult↗

A multifactorial analysis of concurrent patch-test reactions to nickel, cobalt, and chromate.

BACKGROUND: Previous research indicates that positive patch tests to nickel (II) sulphate, cobalt (II) chloride and potassium dichromate commonly occur together. METHODS: To further examine the relationship between nickel, cobalt, chromate, and the factors that may potentially be related to concurrent sensitizations to two or all three metal allergens, data from the Information Network of Dermatology Departments have been investigated. RESULTS: Women had a higher conditional odds of concurrent nickel-cobalt (OR = 6.80; 95% CI: 5.65-8.19) and nickel-chromate (OR = 2.13; 95% CI: 1.67-2.72) reactions than men. Construction workers had a significantly higher odds of cobalt-chromate reactions (OR = 13.89; 95% CI: 10.36-18.64), while the odds of isolated cobalt allergy was only 0.92 (95% CI: 0.48-1.74). Patients with underlying atopic eczema/dermatitis syndrome had a 40-90% higher chance of any positive outcome, which involved chromate. Polysensitization, defined as the number of positive reactions to standard series substances other than nickel, cobalt, and chromate, was also significantly associated with the concurrent reactions; moreover, steady and significant effect gradients were noted. CONCLUSIONS: This research confirms the occupational nature of cobalt-chromate concurrent reactions, in particular, in construction workers. Polysensitization, which is considered to represent susceptibility to delayed-hypersensitivity in general, is also associated with the concurrent reactions to the metals. Hence, not only coupled exposure, but also individual susceptibility may be responsible for concurrent reactions to metals in man.

Adult↗

Allergic and non-allergic periorbital dermatitis: patch test results of the Information Network of the Departments of Dermatology during a 5-year period.

Periorbital dermatitis is common and can be due to the external use of ophthalmic drugs. We evaluated patch test results of the Information Network of the Departments of Dermatology. During a 5-year period (1995-99), of a total 49,256 patch-tested patients, 1053 (2.1%) were eventually diagnosed as allergic periorbital contact dermatitis (APD) and 588 (1.2%) as non-allergic periorbital dermatitis (NAPD). Patient characteristics between APD, NAPD and other cases (OCs) differed with respect to sex (19.7% male in both periorbital groups versus 36.3% in OCs), atopic dermatitis (10.4% in APD versus 60.2% in NAPD versus 16.9% in OCs) and age, APD being substantially more often (68.2%) aged 40 and above than NAPD (52.6%). Several of the top allergens in OCs [such as fragrance mix, Myroxylon pereirae resin (balsam of Peru), lanolin alcohol and potassium dichromate] caused significantly fewer positive test reactions in both periorbital groups. In contrast, thimerosal, phenylmercuric acetate, sodium disulfite, gentamicin sulfate, phenylephrine hydrochloride and benzalkonium chloride tested positively significantly more often in APD but not in NAPD, verifying them as true ophthalmic allergens. Finally, in 42 cases (4%) of APD patients, additional allergens were identified by testing of the patients' own substances (mostly beta-blockers, oxybuprocaine and dexpanthenol), supporting the necessity of testing with ophthalmic drugs as is where individual substances are not readily available.

Adult↗

Iodopropynylbutyl carbamate 0.2% is suggested for patch testing of patients with eczema possibly related to preservatives.

BACKGROUND: Iodopropynyl butylcarbamate (IPBC) is a new preservative in medical and cosmetic leave-on products. Although cases of allergic contact dermatitis to IPBC have been reported, it is not known whether the usual test concentration of 0.1% is appropriate for screening tests with IPBC. OBJECTIVES: To determine the concentration of IPBC that should be used in screening patch tests. METHODS: An analysis was made of data filed by 26 centres of dermatology on patch tests performed with one or two concentrations of IPBC (0.1%, 0.2%, 0.3% or 0.5%) in 8106 unselected patients. Criteria used to determine the best test concentration of IPBC were the reaction index, the positivity ratio, the rate of crescendo reactions, and the relations between IPBC reactions and the MOAHLFA index irritant reactions to sodium lauryl sulphate (SLS), and allergic reactions to other contact allergens including preservatives. RESULTS: IPBC 0.1%, 0.2%, 0.3% and 0.5% yielded 0.5%, 0.8%, 1.3% and 1.7% positive reactions, but this increase was accompanied by an even greater increase in doubtful and irritant reactions. These figures and the other criteria examined suggested the range of suitable test concentrations of IPBC to lie between 0.2% and 0.3%. A detailed analysis of MOAHLFA indices and of associations between reactions to IPBC and reactions to other allergens and to SLS showed that most of the positive reactions to IPBC 0.2% can be assumed to be allergic ones and that with IPBC 0.2% fewer false-positive reactions can be expected than with IPBC 0.3%. CONCLUSIONS: Patch testing with IPBC 0.2% is suggested for patients with eczema possibly related to preservatives.

Adult↗

[Epidemiologic surveillance of contact allergens. The "monitoring series" of IVDK (Information Network ofDermatologic Clinics for Detection and Scientific Evaluation of Contact Allergy].

The selection of the most important contact allergens is subject to a continuous change. Several factors may influence the sensitization rates and thus the decision, which substances to include in the standard series of the most frequent allergens. The Information Network of Departments of Dermatology adds substances of interest for a certain time period to the standard series in order to evaluate parameters such as sensitization rate, grade of reaction, and clinical relevance of positive reactions. In 6 testing periods starting in 1996, 13 test substances were evaluated. Due to the results, propolis, compositae mix, and bufexamac were included in the standard series in 1999, while lyral was added in 2002. Sorbitansesquioleat, dispers blue mix, and iodopropynyl butylcarbamate are under further discussion. Substances such as glutaraldehyde and p-aminoazobenzole should be tested in certain risk groups only, whereas the steroids budesonide and tixocortol should be tested when clinically suspected.

Allergens↗

[Decrease in nickel sensitization in young patients--successful intervention through nickel exposure regulation? Results of IVDK, 1992-2001].

BACKGROUND: In the early 1990s, the prevalence of nickel contact allergy was high-almost 20% on a population level, and some 40% in contact dermatitis patients. Around that time, nickel exposure was starting to be regulated. PATIENTS/METHODS: Descriptive and bivariate analyses of patch test results of all patients tested with nickel sulfate (5% pet.) in the departments joining the Network of Departments of Dermatology (IVDK) 1992-2001 (n=82,991, women: 52,709; men: 30,282). The annual frequency of sensitization to nickel was analyzed in women and men in four age subgroups (<31/31 to <44/44 to 58= or >58). RESULTS: In young women less than 31 (n=13.909) the prevalence of contact allergy to nickel decreased significantly from 36.7% in 1992 to 25.8% in 2001. In young men in the same age group (n=7087), the prevalence dropped from 8.9% in 1992 to 5.2% in 2001. CONCLUSIONS: The observed decline indicates that measures to limit the release of nickel from costume jewelry helped reduce the prevalence of nickel allergy. In general term, allergen elimination or reduction is an effective primary prevention strategy which does not depend on individual behavior modifications.

Adolescent↗

Patch testing with the irritant sodium lauryl sulfate (SLS) is useful in interpreting weak reactions to contact allergens as allergic or irritant.

Several contact allergens are tested at concentrations which might cause irritant reactions. In this study we investigated whether the reactivity to a standard irritant is useful in identifying subjects with hyperreactive skin yielding a higher rate of doubtful or irritant reactions. Sodium lauryl sulfate (SLS) 0.5% (aqua) was tested in addition to the standard series routinely for 5 years in the Department of Dermatology, Dortmund. For data analysis, we compared reactions at D3 to the standard series, the vehicle/emulsifier and preservative series and benzoyl peroxide to the reactions obtained with SLS. Proportions were standardized for age and sex. The association between reactivity to a certain allergen and SLS reactivity as a dichotomous outcome, controlled for age and sex as potential confounders, was assessed with logistic regression analysis. Results showed that of the 1600 tested patients, 668 (41.8%) had an irritant reaction to SLS which exceeded 2 + in only 41 patients. Seasonal variation was statistically significant, showing reduced SLS reactivity in summer vs. winter. Patients with irritant reactions to SLS showed significantly more erythematous reactions to the following 10 allergens of the standard series: fragrance mix, cobalt chloride, balsam of Peru (Myroxylon pereirae), lanolin alcohol, 4-phenylenediamine base (PPD), propolis, formaldehyde, N-isopropyl-N'-phenyl-p-phenylenediamine (IPPD), benzocaine, and 4-tert-butylphenol-formaldehyde resin. No significant differences regarding strong positive allergic reactions were observed. Concerning other allergens, significantly more erythematous reactions were observed in SLS-reactive patients to benzoyl peroxide, octyl gallate, cocamidopropyl betaine, Amerchol L-101, tert-butylhydroquinone, and triethanolamine. In the SLS-reactive group of patients, the reaction index was negative for 10 allergens of the standard series compared to only 5 in the SLS non-responder group. For the first time, this study, based on a large data pool, revealed a significant association between reactivity to the irritant SLS and erythematous reactions to certain allergens. With SLS as a marker for hyperreactive skin at hand, some of these reactions can now be classified as irritant more confidently, particularly if there is no history of exposure to the allergen.

Allergens↗

Risk factors for contact allergy to nickel - results of a multifactorial analysis.

To quantify the independent impact of potential risk factors for nickel contact allergy (NCA), a multifactorial Poisson regression analysis of standardized anamnestic and patch test data (with nickel sulfate, 5% in petrolatum) was performed, comprising 74 940 patients assessed in the 33 German and Austrian contact dermatitis units of the Information Network of Departments of Dermatology (IVDK) between 1992 and 2000. NCA was observed in 15.5% patients. Female sex was the strongest risk factor (prevalence ratio 3.74, 95% CI: 3.51-3.98). Risk increased monotonically and significantly with decreasing age. Atopic dermatitis was not a risk factor. The year of patch test had no influence on NCA risk. Significant variation of risk between occupations was observed. In conclusion, our multifactorial analysis was able to quantify the impact of established risk factors and additionally address other, e.g. occupational, factors yet unidentified.

Adult↗

The spectrum of allergic (cross-)sensitivity in clinical patch testing with 'para amino' compounds.

BACKGROUND: Allergic contact sensitization to 'para amino' compounds is frequent and the spectrum of cross-reactivity between members of this chemical group is variable. METHODS: A retrospective analysis of clinical patch test data obtained with a special test series in the centres of the Information Network of Departments of Dermatology (IVDK) between 1995 and 1999. RESULTS: In the 638 patients tested with the above test panel positive reactions were observed most often to p-aminoazobenzene (16.2%), p-phenylenediamine (14.1%), p-toluylenediamine (10.0%), followed by 4,4'-diaminodiphenylmethane (8.5%), Disperse Orange 3 (8.4%) and p-aminophenol (3.1%). Among the 544 patients tested with p-phenylenediamine and all seven additional 'para amino' compounds, concordance between reactions varied greatly. The stronger the positive test reaction to p-phenylenediamine, p-toluylenediamine or p-aminoazobenzene, the more frequently additional positive reactions to the other compounds were observed. CONCLUSIONS: A screening employing several 'para amino' compounds is necessary to describe the individual spectrum of allergic contact sensitization, as there is no reliable marker substance. Further research should aim at (i) establishing the mechanism of cross-reactivity to 'para amino' compounds and (ii) identifying exposures in the environment.

4-Aminobenzoic Acid↗

The preservative iodopropynyl butylcarbamate: frequency of allergic reactions and diagnostic considerations.

The preservative iodopropynyl butylcarbamate (IPBC) (0.1% in petrolatum) was tested in 4883 consecutive patients for 18 months between January 1998 and June 1999. With regard to the MOAHLFA-Index, the study population comprised 37% males; 17% with occupational and 19% with atopic dermatitis; 31% with hand, 10% with leg and 17% with face dermatitis; 61% were age 40 and above. According to readings at D3, 0.3% were allergic to IPBC, with 14 + and 2 + + reactions. Doubtful or irritant reactions occurred twice as frequently. Patients exposed for 24 h (n = 1814) reacted less frequently (0.1%) than the remaining patients exposed for 48 h (0.5%). Considering the possibility that a certain proportion of + reactions could be false positive, the reaction pattern was evaluated. More than 80% of the positive reactions displayed a crescendo or plateau time pattern. Furthermore, 18 of 43 doubtful reactions (?) appeared as late as D3 (thus, these could be false negative), whereas the majority of doubtful reactions occurred earlier and displayed a decrescendo pattern (corresponding to a typical irritant pattern). In conclusion, the large proportion of '?' reactions may be due not only to the irritant potential of the substance, but also to test concentrations not being high enough to elicit an allergic reaction. We propose that higher concentrations of IPBC (0.3%) should be evaluated in a study also addressing suitable validation tests like ROAT or PUT.

Adult↗