Search PubMed⌕ Search

Biomedical subjects

J Fourcade

Publications and source records attributed to J Fourcade.

At least 109 records · Page 6Linked to original sources

Persistent ductus venosus without portal hypertension in a young alcoholic man.

The discovery of a large patent ductus venosus resulted from radiological investigations in a 34-year-old man, a chronic alcoholic of low mental status. Splenoportal and inferior caval venograms were performed because of recent exacerbation of the neurological symptoms and electroencephalographic criteria of portacaval encephalopathy. Portal pressure was 8 mm Hg. A liver scan, a laparoscopy, and a liver biopsy were performed. They showed that the gland was atrophic with a microscopic appearance of alcoholic fibrosis, but without any nodular regeneration. The relationship between the fistula, the mental state, and the atrophic liver is discussed. Such a malformation appears to be very uncommon.

Adult↗

[Portal hypertension and hypervitaminosis A. Apropos of 2 cases and review of the literature].

Portal hypertension consecutive to hypervitaminosis A has seldom been well documented. Two cases are reported here. The first case concerns a 39-year old woman who had taken meladinine (8-methoxypsoralen) for the purpose of tanning. In the second case, a 43-year old woman had absorbed Plethoryl (a combination of tiratricol, cyclovalone and retinol) in order to lose weight. Both patients had histological hepatic lesions, such as hypertrophic Ito cells, perisinusoidal cirrhosis and spontaneous autofluorescence, suggestive of vitamin A overload, associated with a hepatic vein pressure gradient of 10 mmHg or more and high liver concentrations of vitamin A. The responsibility of Plethoryl in case 2 is beyond any doubt, but the mechanism of hypervitaminosis in case 1 is controverted. A review of the literature has provided detailed information on the signs of vitamin A overload, the frequency of which is probably underestimated. Patients with portal hypertension of unknown origin should be investigated for hypervitaminosis A.

Adult↗

Ultrasonically continuously guided renal biopsy.

Since 1980 we have refined a procedure for renal needle biopsy with continuous ultrasonic guidance (USRNB) which facilitates control of the needle progression through the soft tissues to the lower pole of the kidney. The advantage of this method is evident in a selected population (major obesity, small kidneys). We compared this procedure to the conventional blind biopsy in a series of 32 nonselected patients. Tissue samples with more than 10 glomeruli were obtained in 87% of patients with 2.8 punctures using USRNB, the difference was significant when compared to a blind technique (56%, 4.0, respectively, p less than 0.05). USRNB has been performed in 108 patients with 2 failures due to a poor echographic contrast. Reasons why this procedure should be substituted for the blind technique include: (i) Less morbidity, (ii) improvement of the quality of renal tissue, (iii) better comfort for both patient and physician, and (iv) less technical restriction of the biopsy indication when compared to blind renal needle biopsy.

Adult↗

[Association between blood pressure level and the follow up of the guidelines concerning the use of self blood pressure measurement].

OBJECTIVES: To evaluate the characteristics of hypertensive subjects who practise self measurement of blood pressure (SMBP) and their conditions of use, and to identify the properties of subjects using SMBP according the usual guidelines. METHODS: In 531 consecutive hypertensive subjects, referred to hypertension specialists, possessing a SMBP a questionnaire evaluating the condition of use of SMBP was given. Subjects following the guidelines about the use of SMBP have been compared to those using SMBP without specific design of supervision. RESULTS: In this population, aged 62 +/- 14 years, with 57% of men and a mean blood pressure of 147 +/- 23/82 +/- 12 mmHg, the SMBP devices have been bought without medical advice in 50% of cases (265/531). In 45% of cases (239/531), SMBP were made at the wrist. SMBP device was used every days in 26% of cases, every weeks in 27% of cases, every month or more in 22% of cases and only in case of uneasiness in 25% of cases. Blood pressure was measured only in the morning in 25% of cases, in the morning and evening in 31%, only the evening in 8% and at any time of the day in 36% of cases. More frequently 2 BP measurements were realized (47%) and in 19% of cases 3 measurements have been performed. In 15% of cases, the measurements were performed on 3 or 4 days consecutively, more frequently (85%) the measurements were realized without specific design ("once in awhile"). The data of SMBP were noted and showed to the doctor in 34% of cases. Only 12% (64/531) of subjects followed the usual guidelines concerning the use of SMBP (2 or 3 measurements, in the morning and the evening, during 3 or 4 consecutive days). Subjects following the guidelines for SMBP use have a higher SBP at the office than those using SMBP without specific design of supervision (155 +/- 25 mmHg vs 146 +/- 22 mmHg; p<0.01). CONCLUSION: Among hypertensives referred to hypertension specialists most of subjects use SMBP device without a specific design of supervision. Subjects with the most severe hypertension are those who have the best formation for SMBP.

Aged↗

[Systolic blood pressures are not comparable when home blood pressure is measured with a wrist or an arm validated monitor].

OBJECTIVES: To compare home blood pressure values obtained with two validated OMRON (wrist or arm) monitors used sequentially in the same subject. METHODS: In 265 hypertensive subjects referred to hypertension specialists, a self measurement of blood pressure was performed sequentially with an OMRON M4-I (arm cuff, A/A, BHS validation) or OMRON RX-I (wrist cuff, B/B, BHS validation). Each patient recorded home blood pressure during two periods of 4 days with 3 measures in the morning and 3 in the evening. Order for use of each monitor was randomised. With wrist devices, subjects were advised to keep the arm at heart level during measurements. BP values were reported on a standardized document. Patients were asked by a questionnaire about the tolerance and feasibility of the 2 methods. RESULTS: In this population, aged 59 +/- 14 years, with 60% of men and a mean blood pressure of 152 +/- 21 / 86 +/- 14 mmHg, the home blood pressure values were 143 +/- 20/81 +/- 11 mmHg with the arm monitor and 135 +/- 10 / 80 +/- 11 mmHg with the wrist monitor. Mean SBP adjusted on age, initial blood pressure level and period order was significantly lower when home blood pressure monitoring has been recorded with a wrist monitor as compared to an arm monitor (p < 0.001). Self measurement of blood pressure was felt as easy in 92% with the arm monitor and in 96% with the wrist monitor (p < 0.05). Self measurement of blood pressure was felt as constraining in 14% with the arm monitor and in 7% with the wrist monitor (p < 0.01). The feasibility between the two devices was good with none of the value missing in 86% with the arm monitor and in 85% with the wrist monitor. The missing values were in 56% the fourth day. CONCLUSION: Despite the use of two validated monitors, mean SBP is significantly lower when home blood pressure monitoring is recorded with a wrist monitor as compared to an arm monitor. Uncertainty in the arm position with the use of wrist device could explain these results. When advising home blood pressure monitoring, care should be taken to recommend only the use of validated devices and to prefer the use of arm devices in order to avoid the uncertainty of an inadequate utilisation.

Adult↗

[Home blood pressure monitoring in addition to office blood pressure determination is useful in patients with systolic hypertension before their inclusion into a drug trial].

OBJECTIVE: In patients with uncontrolled systolic hypertension, to estimate the value of home blood pressure monitoring in addition to office blood pressure for inclusion in a trial. METHODS: 80 patients with systolic hypertension, defined as SBP > or =140 mmHg and pulse pressure > or =60 mmHg, were treated for 4 weeks with a thiazide diuretic at usual dose (25 mg HCTZ or 1.5 mg indapamide or methyclothiazide 5 mg). Blood pressure was measured using an automatic monitor (Omron M6) at office and at home in the 3 days prior the visit. Subjects with an uncontrolled hypertension were included in the second part of the trial only if there fulfilled inclusion criteria: office SBP > or =140 mmHg and home SBP > or =135 mmHg (mean of 18 measurements obtained on 3 consecutive days) and office pulse pressure > or =60 mmHg. RESULTS: After 4 weeks with diuretic treatment, 62% of patients fulfilled 3 criteria and were included in the second part of the trial. It was observed 76% of patients with office SBP > or =140 mmHg, 72% with office pulse pressure > or =60 mmHg and 70% with both office SBP and PP criteria. However, only 67% of patients had home SBP > or =135 mmHg. Discrepancy between office and home SBP was observed and subjects with a white coat hypertension was noticed in 14% and masked hypertension in 5%. CONCLUSION: If patients with systolic hypertension have to be included into a drug trial because there are uncontrolled, home blood pressure monitoring in addition to office blood pressure is a very useful criteria for inclusion because misclassifications due to white coat or masked hypertension is frequent in these patients.

Aged↗