Imaging temperature changes in an interventional 0.5 T magnet: in-vitro results.

BACKGROUND AND OBJECTIVE: To evaluate the ability of monitoring laser induced temperature changes in an open, interventional 0.5 T magnet, adopting fast T1-weighted sequences. MATERIALS AND METHODS: A fast gradient echo- (FGRE) and a fast spoiled gradient echo-sequence (FSPGR), both enabling an image update every 2.5 s, were investigated for their ability to visualize laser tissue effects at 5 Watt. Laser induced temperature was fluorooptically measured and correlated with signal intensity (SI) changes depicted by magnetic resonance imaging (MRI). MRI-lesions were compared with macroscopic findings. RESULTS: SI changes on FGRE images appeared as early as 15 s following the onset of laser application and were significantly more pronounced than those seen on FSPGR images (p < .0001). A correlation of r = 0.94 (FGRE) and r = 0.92 (FSPGR) between temperature and SI loss was established. Owing to a steeper slope, the FGRE sequence was considered more sensitive to temperature changes. The areas of macroscopic tissue change correlated with those of SI loss, but lesion size was generally underestimated by MRI. CONCLUSION: Laser monitoring is possible with rapid image updates in a midfield (0.5 T) interventional MRI environment using fast gradient echo sequence designs.

Animals↗

Experimental cryosurgery of the liver under magnetic resonance guidance.

The feasibility and the advantages of magnetic resonance (MR)-guided interstitial cryosurgery of the liver in an 0.5 Tesla open MR system have been evaluated. Cryosurgery was performed using an Erbocryo PS system with a nonmagnetic cryoprobe of 6 mm diameter. The probe was inserted into the liver parenchyma under real-time MR control. Using continuous MR imaging two freezing cycles of 12 min each were applied. After conventional and dynamic gadolinium-enhanced MR imaging, the animals were sacrificed after 30 min, 3 hr, 24 hr, 7 days, and 21 days. Each lesion was analyzed using light microscopy. A total of seven cryolesions were made in five animals without any complications from cryosurgery. During real-time imaging, cryolesions appeared as a hemispherical growing signal loss with a mean volume of 16.4 cm3. Macroscopic volumes of the lesions showed a good correlation with dynamic enhanced MR images during follow-up, whereas real-time images usually showed an underestimation of the lesion volumes. Cryosurgery of the liver in an open-configuration MR system is a feasible and safe method. MR imaging allows the guidance and the follow-up of cryolesions of the liver with good accuracy.

Animals↗

Normal myocardial perfusion assessed with multishot echo-planar imaging.

A new magnetic resonance imaging strategy is presented for accessing myocardial perfusion. Most previous work has relied on using T1-weighted fast gradient-echo imaging to monitor dynamically the signal changes during the passage of a contrast media bolus. However, the gradient-echo approach is limited by an inability to image the entire heart with adequate temporal resolution. This paper focuses on a electrocardiogram-gated multishot echo-planar imaging sequence, using the simple strategy of using the intrinsic T1 weighting produced by a repetition time equal to the heart period. To quantitate the sequence's performance with respect to normal myocardial perfusion, seven volunteers were imaged, each with three different doses of the contrast medium gadolinium diethylenetriamine pentaacetic acid (Gd-DTPA). The first-pass dynamics of the contrast were quantified in 13 regions per heart for each examination. In all volunteers, the complete heart could be covered, with five to seven slices, every two heartbeats. Enhancement was homogeneous throughout the left ventricular myocardium, with an enhancement of approximately 50% for the optimum contrast dose of 0.05 mmol/kg Gd-DTPA.

Adult↗

Coronary flow and coronary flow reserve measurements in humans with breath-held magnetic resonance phase contrast velocity mapping.

Objective evidence for coronary lesion significance can be obtained with ischemic stress testing. Since flow-limiting stenoses have already undergone compensatory vasodilatation to maintain flow, the response to vasoactive stimulation is dampened. The degree of response limitation is reflected by the coronary flow reserve (CFR). Absolute volume flow rates can be accurately and noninvasively measured with MRI techniques. The purpose was to assess the ability to measure coronary volume flow rate noninvasively, and characterize the effect of pharmacologic stress on coronary flow quantitatively by using ultrafast, breath-held segmented k-space phase-contrast-MR imaging (PC-MRI). Ten healthy volunteers were examined by using ultrafast breath-held PC-MRI. Coronary volume flow rates were measured in the anterior descending coronary artery (LAD) at rest and following intravenous administration of dipyridamole. CFR was determined based on these data. Mean LAD volume flow rates increased from 38 +/- 11 ml/min before application of dipyridamole to 169 +/- 42 ml/min. The mean CFR amounted to 5.0 +/- 2.6 (median = 4.15). This study demonstrates the feasibility of breath-held PC-MRI to noninvasively quantify coronary volume flow rates over the cardiac cycle. Pharmacologically induced changes in volume flow rate and thus CFR can be quantitated.

Adult↗

Guidewire antennas for MR fluoroscopy.

Before MRI can be used for guiding vascular interventions, the problem of dependably visualizing guidewires must be solved. Ideally, the position and curvature of the tip of the guidewire should be visible to facilitate steering through the vascular system. In this paper, various antennas are described that can be incorporated into a guidewire tip. These antennas allow the guidewire to be visualized with high contrast. Computer simulation and experimental evidence are presented showing the value of adding a passive MR signal source, with a short T1, internal to the coil. The internal source increases the available signal, narrows the apparent width of the guidewire, and allows the use of fast imaging sequences.

Blood Vessels↗

MRI contrast media - new developments and trends. CTA vs. MRA.

Recent developments in the non-invasive techniques of magnetic resonance angiography (MRA) and computerised tomographic angiography (CTA) are challenging conventional catheter angiography. Current indications for both techniques are discussed, such as their ability to diagnose aortic, pulmonary, renal, carotid and peripheral vascular diseases. Both tools provide almost identical clinical results, although each has their own advantages and disadvantages. MRA should be the technique of choice in young patients or those with real impairment since the gadolinium-based contrast agents are non-ionising and do not cause nephrotoxicity. On the other hand, MRA examination times are longer than those typically required for CTA, and therefore MRA is less suited to examinations of acute conditions.

Angiography↗

[Value of contrast-enhanced 3D magnetic resonance angiography of the renal arteries].

PURPOSE: To determine the value of gadolinium-enhanced, three-dimensional breath-hold Magnetic Resonance Angiography (MRA) in the assessment of the aorta and renal arteries in comparison to conventional arteriography (CA). PATIENTS AND METHODS: 49 patients were evaluated with both CA and 3D MRA. 0.3 mmol/kg BW gadolinium-DTPA was administered intravenously in a bolus, using an automated injector. A test bolus method was used for timing of the bolus and beginning of the data acquisition. The intraarterial CA was used as the gold standard. RESULTS: MRA-based assessment of renal artery stenosis was identical with CA in 31 of 45 stenoses (68.8%). Sensitivity and specificity for assessment of renal arterial disease by MRA were 84% and 96%; for clinically relevant lesions they amounted to 90% and 98%. CONCLUSION: The presented contrast-enhanced 3D MRA technique allows for the reliable assessment of renal arterial morphology and pathology.

Adult↗

Three-dimensional contrast-enhanced magnetic resonance angiography of the thoracic vasculature.

Magnetic resonance angiography (MRA) has become a useful non-invasive imaging technique for the assessment of vascular disease. Due to limitations such as respiratory motion artefacts, saturations problems, and long acquisition times, applications of MRA in the thorax have largely been restricted to imaging of the aorta. The recent introduction of breath-hold three-dimensional (3D) contrast-enhanced MRA promises not only to enhance conventional MR protocols for aortic imaging, but to extend the clinical indications of MRI to diseases affecting other vascular structures of the thorax, most notably the pulmonary arteries. This article describes the technical aspects of contrast-enhanced 3D MRA and reviews existing and potential future clinical applications.

Aorta, Thoracic↗

Magnetic resonance-guided laparoscopic interstitial laser therapy of the liver.

BACKGROUND: There is a necessity for an imaging method during laparoscopy to get a three-dimensional access to the target. In this study we evaluated laparoscopic interstitial laser therapy of the liver under magnetic resonance imaging guidance. METHODS: Five domestic pigs underwent laparoscopy in an open-configuration magnetic resonance system. Under simultaneous real-time magnetic resonance imaging interstitial laser therapy was applied to the liver. Magnetic resonance images, macroscopic aspects of the lesions, and light microscopic findings were compared. RESULTS: The interventions could be safely performed. There was no image artifact caused by instruments or by the carbon dioxide. Dynamic gadolinium-enhanced imaging proved to significantly predict the macroscopic volume of the laser lesions. CONCLUSIONS: Magnetic resonance-guided laparoscopic interstitial laser therapy of the liver combines the advantages of minimal invasive surgery and magnetic resonance imaging. Further development should focus on laparoscopic instruments and temperature sensitive sequences.

Animals↗

Virtual colonoscopy with magnetic resonance imaging: in vitro evaluation of a new concept.

BACKGROUND & AIMS: Screening for colonic polyps is desirable. A new concept based on cross-sectional and endoscopic analysis of a magnetic resonance (MR) data set is presented. METHODS: Ex vivo autopsy colonic specimens, containing artificially placed polyps, were obtained and filled with a gadolinium-containing solution. Forty-four thin-section MR images were obtained in a 1.5-T MR scanner in 28 seconds. A three-dimensional endoscopic fly-through of these images was rendered. Fly-throughs and two-dimensional cross-sectional images were analyzed by two observers for the presence of polyps. RESULTS: The average sensitivity and specificity for the detection of polyps based on three-dimensional endoscopic MR colon imaging were 87% and 96%, respectively. Analysis of cross-sectional images showed an overall sensitivity and specificity of merely 57% and 84%, respectively. The difference in the interpretation of three-dimensional MR colonoscopy and two-dimensional cross-sections was statistically significant (P < 0.001). With three-dimensional MR colonoscopy, overall sensitivity for detection of polyps measuring < or =5 mm in length and diameter was 70%; for larger polyps, it increased to 95% (P < 0.01). CONCLUSIONS: The feasibility of an MR-based endoluminal assessment of the colon is shown. Minimal invasiveness, lack of radiation exposure, and high in vitro diagnostic accuracy warrant further investigation of this novel concept.

Colonic Polyps↗

[Ultrafast contrast-enhanced 3D MR angiography of the aorta and renal arteries in apnea].

PURPOSE: To determine the value of ultrafast, gadolinium-enhanced, three-dimensional breathhold magnetic resonance angiography (MRA) in the assessment of the aorta and renal arteries in comparison to conventional arteriography (CA). PATIENTS AND METHODS: 49 patients (31 m, 18 f) were evaluated with both CA and 3D MRA. The 3D MRA data set consisted of 44 continuous sections, acquired in apnoea (23-28 s) using the following parameters: TR/TE 3.9/1.5 ms, flip angle 40 degrees, 3/4 k-space acquisition. 0.3 mmol/kg BW gadolinium-DTPA were administered intravenously in a bolus, using an automated injector. A test bolus method was used for timing of the bolus and beginning of the data acquisition. Intraarterial CA was used as the gold standard in 47 patients; in two patients the intraoperative findings were employed as the standard of reference. CA and MRA were interpreted separately by two different radiologists, who were blinded to the results of the other examiner. RESULTS: All 11 accessory renal arteries were visualised on MRA. MRA-based assessment of renal artery stenosis was identical with CA in 31 of 41 (75%) stenoses, Sensitivity and specificity values for assessment of renal arterial disease were 84.4% and 96.1%, for haemodynamically significant lesions they amounted to 90% and 98.9%, respectively. CONCLUSION: The presented ultrafast contrast-enhanced 3D MRA technique allows for the reliable assessment of aortic and renal arterial morphology and pathology.

Adult↗

[The differentiation of adrenal gland tumors: an improvement in accuracy by a combination of fat-sensitive, T2-weighted and contrast-enhanced MR sequences].

PURPOSE: To determine the diagnostic value of 3 MR sequences for the diagnosis of adrenal tumors. MATERIAL AND METHODS: Retrospective analysis of 32 adrenal tumors (10 malignant, 15 adenomas, 5 inflammatory, 2 phaeochromocytomas) examined by MRT (1.5 T) using T2 turbo spin echo, chemical shift imaging and dynamic contrast-enhanced gradient echo sequences. RESULTS: Differentiation between malignant and benign adrenal tumours by means of T2-weighted sequences, chemical shift imaging and dynamic contrast-enhanced sequences achieved a sensitivity/specificity of 90%/73%, 100%/68% and 90%86%. Accuracy was 78%, 78% and 87%. By combining the three procedures, sensitivity/specificity/accuracy was improved to 100%/91%/94%. CONCLUSION: To differentiate adrenal lesions, the following procedures are recommended: demonstration of fat by chemical shift imaging is indicative of an adenoma. In the absence of any lipid content, T2-weighted and dynamic contrast-enhanced sequences can demonstrate inflammatory lesions.

Adenoma↗

[Intravascular MR imaging: the first in-vivo experiences in an animal arteriosclerosis model].

PURPOSE: To evaluate intravascular MR imaging in normal New Zealand rabbits and hereditary hyperlipidaemic Watanabe rabbits (WHHL) with histological correlation. MATERIAL AND METHODS: The suprarenal abdominal aortas of two normal and two WHHL rabbits were examined by conventional angiography, high resolution MRT with a surface coil and intravascular MRT in a 1.5 T system. The intravascular reception coil consisted of a copper wire loop built into the balloon of an angioplasty catheter. The findings were correlated with histological examinations. RESULTS: Excellent spin echo images with a resolution of 78 x 156 microns were obtained in less than 4 minutes. The arteriosclerotic changes in the vessels of the WHHL rabbits could not be recognised angiographically. High resolution MRT with surface coils showed mural thickening but a detailed demonstration of arteriosclerotic lesions was possible only by means of high resolution intravascular imaging. There was good histological correlation. CONCLUSION: Arteriosclerotic lesions can be demonstrated in vivo by high resolution intravascular imaging.

Angiography↗

[3D MRI of the colon: methods and initial results].

PURPOSE: "Exoscopic" and endoscopic identification of colorectal pathologies via MRI. METHODS: 5 patients (36-88 years), two normal and three with different colorectal pathologies (diverticular disease, polyps and carcinoma of the colon), were examined by MRI after colonoscopy. Subsequent to filling of the colon with a gadolinium-water mixture under MRI-monitoring, 3D-data sets of the colon were acquired in prone and supine positions over a 28 sec breath hold interval. Subsequently multiplanar T1-weighted 2D-sequences were acquired before and following i. v. administration of Gd-DTPA (0.1 mmol/kg BW). All imaging was performed in the coronal orientation. The 3D-data were interactively analysed based on various displays: maximum intensity projection (MIP), surface shadowed display (SSD), multiplanar reconstruction (MPR), virtual colonoscopy (VC). RESULTS: All of the colorectal pathologies could be interactively diagnosed by MPR. On MIP images some pathologies were missed. VC presented the morphology of colon haustra as well as of all endoluminally growing lesions in a manner similar to endoscopy. The colon masses showed uptake of contrast media and could thus be differentiated from air or faeces. CONCLUSION: The potential of CMRI in colorectal diagnosis warrants further investigation in a larger series of patients.

Aged↗

Monitoring of radio frequency tissue ablation in an interventional magnetic resonance environment. Preliminary ex vivo and in vivo results.

RATIONALE AND OBJECTIVES: The authors evaluate the feasibility of monitoring radio frequency (RF) ablation in an interventional, open-configuration, 0.5-tesla magnetic resonance (MR) environment. METHODS: Ex vivo and in vivo RF coagulation necrosis were induced in porcine paraspinal muscle tissue using a 300 kHz monopolar RF generator applying 5 to 20 W over 3 to 9 minutes. Images were acquired simultaneous to RF application, after RF application, and in an intermittent mode (60 seconds of RF followed by 15 seconds of MR imaging). Temperature changes were monitored based on amplitude (ex vivo) and phase alterations (in vivo) of a T1-weighted graded refocused echo (GRE) sequence enabling an update every 2.5 seconds. A standardized color-coded subtraction technique enhanced signal changes. Additionally, T2- and T1-weighted spin echo (SE) images were acquired with and without intravenous contrast. Macroscopic coagulation size was compared with lesion size seen on MR images. RESULTS: Although lesion diameters were related directly to applied RF power, the application mode had no significant impact on coagulation size (P > 0.05). As could be expected, MR imaging during RF ablation resulted in major image distortion. Radio frequency effects were seen on images acquired in the continuous and intermittent modes. Coagulation size seen on GRE images correlated well with macroscopy both ex vivo (r = 0.89) and in vivo (r = 0.92). Poorer correlation was found with postinterventional SE sequences (r = 0.78-0.84). CONCLUSIONS: Magnetic resonance monitoring of RF effects is feasible both ex vivo as well as in vivo using temperature-sensitive sequences in an open-configuration MR environment.

Animals↗

Laser ablation-induced changes in the prostate: findings at endorectal MR imaging with histologic correlation.

PURPOSE: To correlate laser ablation-induced changes in the prostate as depicted at endorectal magnetic resonance (MR) imaging with results at histologic examination. MATERIALS AND METHODS: In eight patients with prostate carcinoma, visually guided laser ablation was performed during lymphadenectomy. Radical prostate resection was performed 4-9 days (mean, 6.9 days) after ablation in seven patients and at 70 days in one patient. The study protocol consisted of (a) endorectal T2-weighted fast spin-echo imaging, (b) dynamic T1-weighted spoiled gradient-echo imaging prior to and after injection of contrast material, and (c) gadolinium-enhanced T1-weighted spin-echo imaging. Imaging findings were correlated with macroscopic and histologic findings. RESULTS: Histologic examination revealed periurethral necrosis with a marginal zone that consisted of partially necrotic tissue, dilated vessels, and hemorrhagic areas. Considerable interindividual difference was observed in the extent of morphologic alterations (area, 0-18.0 cm3). Gadolinium-enhanced images were best suited for assessment of laser ablation-induced changes. The correlation between the volume of altered tissue measured on MR images and in macroscopic specimens was excellent (r2 = .96). CONCLUSION: MR imaging helped monitor changes induced with laser ablation (which differed greatly among individuals). MR monitoring may thus be useful in patients with obstructive benign prostatic hyperplasia after laser ablation.

Aged↗

MR imaging-guided intravascular procedures: initial demonstration in a pig model.

With use of an open 1.5-T magnetic resonance (MR) imager and a tracking catheter, the authors successfully placed the catheter into the left or right sacral artery in pigs. The tracking catheter comprised a 5.3-F percutaneous transluminal angioplasty catheter with a small copper radio-frequency coil in its tip. With use of the coil as an antenna, the catheter tip position was projected in real time onto MR angiography road maps in two planes. Guidance of placement of the catheter with the MR angiography road maps allowed successful embolization, balloon occlusion, and transjugular intrahepatic puncture of the portal system. Specialized catheters can be tracked in vivo to allow MR guidance in intravascular interventional procedures.

Animals↗

Evaluation of the aortoiliac and renal arteries: comparison of breath-hold, contrast-enhanced, three-dimensional MR angiography with conventional catheter angiography.

PURPOSE: To determine the diagnostic accuracy of breath-hold, contrast material-enhanced, three-dimensional (3D) magnetic resonance (MR) angiography in the assessment of the aortoiliac inflow tract and renal arteries with conventional catheter angiography as the standard of reference. MATERIALS AND METHODS: In 39 patients with symptomatic peripheral vascular disease, both catheter and contrast-enhanced, 3D MR angiography were performed. In a prospective blinded analysis, each vascular segment (23 segments per arterial tree) was evaluated for the presence of obstructive stenosis, graded as mild (<50%), severe (50%-99%), or occlusion (100%), as well as for aneurysmal disease. RESULTS: Obstructive (n = 2) and aneurysmatic aortic (n = 6) lesions and 10 of 11 accessory renal arteries were identified and graded correctly with MR angiography. For detection of hemodynamically significant stenotic lesions (>50%) or occlusions with MR angiography, sensitivity and specificity, respectively, were 93% and 98% for the renal arteries, 96% and 100% for the common iliac arteries, 93% and 93% for the external iliac arteries, and 96% and 94% for the internal iliac arteries. CONCLUSION: The diagnostic performance of contrast-enhanced 3D MR angiography is comparable with that of catheter angiography and thus may contribute to assessment of the aorta, the renal arteries, and the pelvic arterial system in patients with peripheral vascular disease before they undergo therapy.

Angiography, Digital Subtraction↗