Search PubMed⌕ Search

Biomedical subjects

J F Debatin

Publications and source records attributed to J F Debatin.

At least 109 records · Page 6Linked to original sources

MR imaging of the augmented breast.

Mammographic evaluation of the augmented breast is challenging, since breast implants obscure significant amount of breast tissue while diminishing the effect of compression. Posttherapeutic scarring can make mammographic interpretation even more difficult. MRI has thus evolved into the modality of choice for diagnosing implant complications as well as detection of primary or recurrent breast cancer in these patient population. The present article attempts to give an overview of the MR findings of different breast augmentation and reconstruction techniques, i. e. prosthetic breast implants, breast reconstruction with autogenous tissue, free silicone injections and fat grafts, and their complications.

Adipose Tissue↗

MR-based assessment of vascular morphology and function.

Initially, time-of-flight angiography found its way into clinical routine for imaging vascular morphology. In conjunction with phase-contrast imaging, functional and morphological assessment of vascular pathology became possible. The flow dependence and associated artifacts inherent to these techniques have restricted the clinical use of these magnetic resonance angiography (MRA) techniques to the extra- and intracranial arterial, as well as the systemic and portal, venous systems. With the advent of high-performance gradient systems a new, promising MRA strategy has been developed: contrast-enhanced 3D MR angiography. It is based on the combination of rapid 3D imaging and the T1-shortening effect of intravenously infused paramagnetic contrast. This review provides a technical overview and critically discusses the clinical application for the different MRA techniques regarding morphological as well as functional assessment of the vascular system.

Adult↗

MR guidance of laser disc decompression: preliminary in vivo experience.

The purpose of this study was to perform percutaneous laser disc decompression (PLDD) under MR guidance in an open configuration 0. 5-T MR system. Following failed conservative treatment for 6 months, eight patients with contained disc herniations were enrolled in the study. Following MR guided introduction of the laser fiber into the targeted disc space, the laser-induced temperature distribution was visualized using a color-coded subtraction technique based on a T1-weighted GRE sequence. In seven patients PLDD could be performed. In all cases laser effects were depicted by MR. In this regard the color-coded technique was found to be superior to conventional magnitude images. Whereas no apparent decrease in the extent of herniation was discovered immediately following PLDD, T2-weighted FSE images showed signal intensity alterations in two of the seven patients. Clinical evaluation, obtained 3-4 months after PLDD, revealed a fair (n = 2) or good (n = 4) response to the treatment. One patient showed no change in symptoms. MR guidance and monitoring of PLDD is feasible within an open 0.5-T system and seems to render PLDD more safe and controllable.

Adult↗

Interactive MR-guided biopsies of the thyroid gland: validation of a new method.

The aim of this study was to demonstrate the clinical feasibility and utility of an interactive MR-guidance system to target and biopsy thyroid lesions, and to compare resolution between ultrasound and interventional MR imaging in the evaluation of thyroid lesions. Twenty thyroid lesions of 18 patients were interactively biopsied using a 0.5-T superconducting open magnet system. Stereotactic localization of the needle and imaging was accomplished using T1-weighted gradient-recalled-echo (GRE) images. Representative cytological material was retrieved in 16 of 20 lesions (benign cystic or colloid goiter: n = 14; one de Quervain's thyroiditis and one follicular neoplasia). Lesions smaller than 1.5 cm detected by ultrasound could not be visualized adequately on GRE images. Lesions smaller than 1.5 cm were successfully biopsied by ultrasound (three colloid and haemorrhagic goiters and one adenoma). Magnetic-resonance-guided interactive biopsies and positioning of non-ferromagnetic needles in the thyroid gland are technically feasible and safe. Compared with high-resolution ultrasound, lesions larger than 1.5 cm can be adequately visualized and biopsied. Magnetic-resonance-guided placement of non-ferromagnetic needles is no substitute for high-resolution ultrasound in clinical work-up of thyroid lesions.

Biopsy, Needle↗

MRI of the uterus, uterine cervix, and vagina: diagnostic performance of dynamic contrast-enhanced fast multiplanar gradient-echo imaging in comparison with fast spin-echo T2-weighted pulse imaging.

The aim of this study was to compare the diagnostic performance of contrast-enhanced fast multiplanar gradient-echo (GRE) and T2-weighted fast spin-echo (FSE) image sets in the assessment of uterus, cervix, and vagina. Fast (up to 20 contiguous sections in 23 s) multiplanar GRE and FSE images of 45 patients referred for imaging of the female pelvis were evaluated retrospectively with regard to overall image quality and the ability to detect normal anatomic structures, as well as lesion conspicuity. Results were compared with histologic findings (n = 29) or clinical follow-up. Furthermore, a quantitative assessment of contrast-to-noise ratios among normal uterine and cervical structures as well as uterine lesions was performed for both sequences. On GRE images, uterine and cervical differentiation was best seen on the image sets acquired 15 and 60 s following contrast enhancement and results were significantly better compared with delayed images (p < 0.05). Delineation of the junctional zone was significantly (p < 0.05) better on FSE compared with GRE images; no significant difference was seen for the other anatomic structures. Overall image quality of GRE and FSE images was similar. Sensitivity for lesion detection based on both GRE and FSE images was 96% with a sensitivity of 93% for GRE, and 81% for FSE images alone, respectively. Using the extended McNemar chi 2 test, the difference in diagnostic performance between FSE and GRE revealed no significant difference, whereas the combination of both techniques performed better than FSE imaging alone (p < 0.05). The presented data suggest that dynamic contrast-enhanced GRE imaging should be part of an MR examination of the female pelvis. Combined GRE and FSE imaging provide an excellent sensitivity in the assessment of uterine and vaginal pathologies.

Adolescent↗

Optimization of contrast dosage for gadolinium-enhanced 3D MRA of the pulmonary and renal arteries.

To determine the minimal contrast dosage required for diagnostic contrast-enhanced three-dimensional (3D) magnetic resonance angiography (MRA) image quality of the pulmonary (PAs) or renal arteries (RAs). In 12 volunteers (10 females, 2 males; mean age 24 years) imaging was performed with 4 different dosages: 0.05, 0.1, 0.2 and 0.3 mmol/kg of body weight (BW) 0.5 M gadolinium (Gd) contrast agent. The PAs and RAs were evaluated separately each in groups of six volunteers. Qualitative and quantitative signal-to-noise ratio (SNR) image analysis was performed. For the PAs, the increases in signal-to-noise ratio were paralleled by increases in image quality ratings. For the PAs, with the use of 0.05 mmol/kg, only 50.3% of all segments were rated diagnostic, whereas with higher dosages the percentage rose to 89.2% for 0.1 mmol/kg, 98.2% for 0.2 mmol/kg. and 99.1% for 0.3 mmol/kg. For the RAs, 0.3 mmol/kg provided no significant increase in singal-to-noise ratio compared to 0.2 mmol/kg (p = 0.4). Only by a dosage of 0.2 and 0.3 mmol/kg, all evaluated segments were diagnostic evaluable. A dose of 0.2 mmol/kg is required for proper assessment of the RAs or PAs.

Adult↗

[Active instrumental guidance in interventional MR tomography: introduction to a new concept].

PURPOSE: An active MR-based guidance system for visualisation of invasive instruments is described. METHODS: The principle of MR tracking is based on the integration of a miniaturised coil into the tip of the instrument itself. A phantom experiment was designed to demonstrate the localising accuracy of this technique. In addition, biocompatibility and warming effects were evaluated. Preliminary intravascular applications that were performed in animal experiments under MR guidance included embolisation, vascular occlusion as well as transjugular intrahepatic punctures. Percutaneous biopsies, cholecystostomies and laparoscopic applications were also evaluated with MR tracking. RESULTS: Phantom experiments confirmed an excellent localisation accuracy of MR tracking compared top conventional radiography. At a field strength of 0.5 T, the temperature increase remained below 2 degrees C. Results of phantom experiments revealed a potential of significant heating dependent on the sequence parameters employed. MR tracking allowed a robust, simultaneously biplanar visualisation of the instrument tips in real time. Based on MR "road map" images, various intravascular and percutaneous interventions were successfully performed in vivo under MR guidance. CONCLUSIONS: MR tracking is a flexible concept permitting monitoring in the guidance of instruments in an MR environment. Various preliminary in vitro and in vivo experiments demonstrate safety, localisation accuracy and feasibility of this biplanar localisation technique in real time.

Biopsy, Needle↗

[The MRT and MRA of kidney transplants--vascular and perfusion assessment].

PURPOSE: To document the value of fast contrast enhanced-sequences in the assessment of the vascular supply and parenchymal perfusion in renal transplants. PATIENTS: 18 recipients of a renal transplant were examined with a 1.5-tesla-MR-system. The protocol included fast contrast enhanced 3D MR angiography and coronal 2D GRE sequences. The transplant artery and vein were assessed as well as regional parenchymal perfusion. RESULTS: 3D MRA detected three transplant artery stenoses and one occlusion. In addition, two renal vein thromboses and one compression were identified. Perfusion deficits were documented in 8 renal transplants: renal infarction (n = 4), cortical necrosis (n = 2), acute tubular necrosis (n = 1) and venous ischemia (n = 1). Fluid collections were documented as well as dilation of the collecting system and abnormalities of the surrounding tissues. CONCLUSION: Contrast enhanced MRI and MRA permit a comprehensive assessment of renal transplants without inducing nephrotoxicity.

Adult↗

Contrast-enhanced magnetic resonance angiography of the renal arteries. Original investigation.

RATIONALE AND OBJECTIVES: The authors determine the value of contrast-enhanced, three-dimensional (3D) magnetic resonance angiography (MRA) in the assessment of the renal arteries in comparison with conventional arteriography (CA). METHODS: One hundred three patients (71 m, 32 f) were evaluated with both CA and 3D MRA. The 3D MRA data set consisted of 44 contiguous sections, acquired in apnea (23-28 seconds) using the following parameters: TR/TE 3.9/1.5 milliseconds, flip angle 40 degrees to 50 degrees, 3/4 k-space acquisition. A bolus of 0.3 mmol/kg BW gadolinium-DTPA was administered intravenously, using an automated injector. A test bolus method was used for timing of the bolus relative to the beginning of the data acquisition. Intra-arterial CA was used as the standard of reference in all patients. Separate interpretations of the CA and MRA results were made by two different pairs of radiologists, who were each blinded to the results of the other exam. RESULTS: In all, 31 of 33 accessory renal arteries were correctly identified. All 205 main renal arteries were seen with MRA. Of 65 significant stenoses identified on CA, 61 were correctly identified and graded by MRA. Sensitivity and specificity values for the assessment of significant renal arterial lesions were 93% and 90%, respectively. CONCLUSIONS: Breath-hold, contrast-enhanced 3D MRA allows for the reliable assessment of renal arterial morphology and pathologic states.

Aged↗

Contrast-enhanced three-dimensional magnetic resonance angiography of the splanchnic vasculature before and after caloric stimulation. Original investigation.

RATIONALE AND OBJECTIVES: To develop a comprehensive noninvasive magnetic resonance angiography (MRA) strategy for the morphologic and functional assessment of the splanchnic arteries, based on a combination of breath-held contrast-enhanced 3D MRA and segmented k-space 2D phase-contrast acquisitions acquired before and after caloric stimulation. METHODS: Ten healthy volunteers were examined twice: once in the fasting state (6 hours with no food intake) and a second time following caloric stimulation with a standard 475-kcal meal. Flow in the superior mesenteric artery (SMA) and vein (SMV) was quantitated using a 2D breath-held, segmented k-space phase-contrast (PC) acquisition in a plane perpendicular to the axis of the vessels, while vascular morphology was displayed with a contrast-enhanced 3D MRA acquisition consisting of 44 contiguous 2-mm sections, acquired in apnea (28 seconds). For comparative analysis, the splanchnic vasculature was divided into 11 segments and evaluated on a 2-point scale (cannot exclude pathology, can exclude pathology). RESULTS: Flow volume in the SMA increased from 2.3 ml/min/kg (+/- 0.9 ml/min kg) to 7.3 ml/min kg (+/- 4.7 ml/min kg) following caloric stimulation (P < 0.05). Flow in the SMV exceeded flow in the SMA and increased from 3.4 ml/min/kg (+/- 0.3 ml/min kg) to 9.1 ml/min/kg (+/- 4.8 ml/min/kg) following stimulation. Flow volume of SMV correlated better with SMA flow after stimulation. Caloric stimulation significantly improved visualization of the splanchnic arterial vasculature (P < 0.05). Only 5 of 110 evaluated arterial segments (4.5%) remained inadequately seen to exclude vascular pathology. CONCLUSION: Magnetic resonance imaging offers a comprehensive assessment of the splanchnic arterial vasculature based on 3D display of vessel morphology and analysis of flow function. While the most relevant proximal vessel segments are visible even under fasting conditions, caloric stimulation enhances visualization of small vessels.

Adult↗

Dynamic MR defecography with a superconducting, open-configuration MR system.

PURPOSE: To evaluate dynamic magnetic resonance (MR) defecography performed with a superconducting, open-configuration system in diagnosis of defecation disorders. MATERIALS AND METHODS: Five healthy volunteers and 15 patients with defecation disorders were studied with MR defecography performed with a superconducting, open-configuration system; the patients also underwent fluoroscopic defecography. Before MR imaging, the rectum was filled with 300 mL of mashed potatoes mixed with 1.5 mL of gadopentetate dimeglumine. T1-weighted gradient-echo images were acquired every 2 seconds in the midsagittal plane with the patient at rest, at maximal contraction of the anal sphincter, during straining, and during defecation. RESULTS: MR defecography permitted analysis of the anorectal angle, anal canal, puborectal muscle, and descent of the pelvic floor. Owing to the high signal intensity of the intraluminal contrast material, the rectal walls were well demonstrated on the MR images, permitting visualization of intussusception and rectocele. Concomitant demonstration of structures surrounding the anorectal canal was helpful in assessment of spastic pelvic floor syndrome and descending perineum syndrome. MR defecography was superior to fluoroscopic defecography and allowed detection of all clinically relevant pathologic conditions except for one. CONCLUSION: Dynamic MR defecography is an attractive alternative for evaluation of defecation disorders.

Aged↗

Radio-frequency-induced thermoablation: monitoring with T1-weighted and proton-frequency-shift MR imaging in an interventional 0.5-T environment.

PURPOSE: To evaluate the feasibility and accuracy of monitoring radio-frequency (RF) ablation with an open-configuration, 0.5-T magnetic resonance (MR) imager. MATERIALS AND METHODS: Thirty-six in vivo RF ablation experiments were performed in porcine paravertebral muscle (n = 24) and liver (n = 12). A 90 degrees C tip temperature was applied for 3-9 minutes. MR images were acquired after continuous or during intermittent RF application. Temperature changes were monitored as signal intensity and proton-frequency-shift (PFS) alterations in two T1-weighted gradient-echo sequences. An update image was obtained every 2.5 seconds (20/10 [repetition time msec/echo time [TE] msec]) or every 5.0 seconds (40/20). A color-coded subtraction technique enhanced the signal intensity and PFS changes. Macroscopic coagulation size was compared with MR image lesion size. RESULTS: The RF application mode had no significant effect on coagulation size in muscle or liver (P > .05). Twenty-two of 24 coagulative lesions in muscle and nine of 12 in liver were demonstrated with the PFS technique. Accuracy of lesion size determination depended on TE (TE = 20 msec, r = .95; TE = 10 msec, r = .78 [P < .01]). The T1-weighted technique depicted only six of 24 muscle and three of 12 liver lesion ablations. In the lesions depicted, macroscopic size was significantly underestimated (P < .001). CONCLUSION: PFS MR monitoring of RF effects in liver and muscle is feasible and accurate. The PFS technique outperformed the T1-weighted technique.

Animals↗

Detection of mass lesions with MR colonography: preliminary report.

PURPOSE: To evaluate the performance of magnetic resonance (MR) colonography in the detection of colorectal mass lesions. MATERIALS AND METHODS: Twenty-three patients underwent MR colonography preceding colonoscopy. The colon was filled with a gadolinium-water mixture (1:100) with MR imaging guidance, and the patient was imaged prone and supine with a breath-hold three-dimensional spoiled gradient-recalled sequence. In addition, two-dimensional spoiled gradient-recalled images were acquired before and after intravenous administration of gadopentetate dimeglumine. Images were interactively analyzed on the basis of multiplanar reconstruction by two radiologists. For regions that were not conclusively assessable with multiplanar reconstruction, virtual intraluminal endoscopic images of the colon were reconstructed. MR findings were correlated with colonoscopic results. RESULTS: Two patients were excluded from the analysis. Findings in eight of 11 patients were correctly assessed as normal and in six of 10 as mass-positive. In the four patients with false-negative findings, one had two 8-mm polyps and the other three had polyps smaller than 5 mm. All nine mass lesions larger than 10 mm, as well as four of the 10 polyps ranging between 5 and 10 mm, were detected, but all polyps smaller than 5 mm were missed. In contrast to the polyps less than 5 mm, the four missed polyps (5-10 mm) could be identified retrospectively on virtual intraluminal endoscopic images. Contrast enhancement was documented in 13 polyps. CONCLUSION: Three-dimensional MR colonography provided virtual colonoscopic viewing and helped detection of colonic polyps.

Adult↗

Intestinal and peritoneal bleeding: detection with an intravascular contrast agent and fast three-dimensional MR imaging--preliminary experience from an experimental study.

PURPOSE: To assess the ability to detect and localize intestinal and peritoneal bleeding with an intravascular contrast agent and fast three-dimensional (3D) magnetic resonance (MR) imaging. MATERIALS AND METHODS: An intravascular contrast agent (NC100150 Injection) was administered into small-bowel specimens at five flow rates; the specimens were imaged with a 3D gradient-echo (GRE) sequence at 1-minute intervals. Radionuclide studies with technetium-99m pertechnetate were performed in the same manner. Subsequently, the MR imaging technique was assessed in vivo. Two intraluminal intestinal and one hepatic bleeding sites were created in an anesthetized pig. Three-dimensional GRE imaging data sets were acquired after intravenous injection of the contrast agent. Imaging findings were confirmed with macroscopic inspection. RESULTS: Contrast material injected at 0.5-2.0 mL/min was detected with both radionuclide and MR imaging after 1 minute. An accumulated volume of 0.2 mL was necessary to demonstrate the bleeding site. In vivo, all bleeding sites were readily detected on MR images. Contrast material accumulated in the intestines and peritoneal space. CONCLUSION: In conjunction with an intravascular contrast agent, 3D MR imaging allows detection and localization of gastrointestinal bleeding. The extent of the bleeding can be determined with repeat data acquisitions.

Animals↗

Improved diagnostic accuracy in dynamic contrast enhanced MRI of the breast by combined quantitative and qualitative analysis.

To develop an optimized interpretation strategy of dynamic contrast enhanced breast MRI based on a combination of quantitative and qualitative criteria, the features of 120 histopathologically verified lesions were retrospectively analysed on contrast enhanced dynamically acquired (before and 1, 2, 4 and 7 min following injection of 0.2 mmol kg-1 gadolinium-DOTA) three-dimensional gradient echo images. Quantitative criteria, based on relative signal intensity measurements and qualitative morphological features, including lesion shape, margins and enhancement patterns were analysed in regard to differentiating malignant (n = 70) from benign (n = 50) lesions. Quantitative assessment of enhancement profiles was most accurate when analysis was based on early 1 min measurements. Using a 90% threshold, sensitivity and specificity in detecting breast cancer were 83% and 66%, respectively. When based on qualitative morphological analysis alone, sensitivity and specificity were 83% and 54%. Combined quantitative and qualitative assessment yielded a considerably higher sensitivity, specificity and accuracy of 93%, 74% and 85%, respectively. In conclusion, results from dynamic contrast enhanced breast MRI can be improved by basing the interpretation on both quantitative and qualitative criteria.

Adult↗

Diagnostic impact of four postprocessing techniques in evaluating contrast-enhanced three-dimensional MR angiography.

OBJECTIVE: The purpose of this study was to determine the added diagnostic value of various three-dimensional (3D) data viewing techniques when analyzing contrast-enhanced 3D MR angiography. MATERIALS AND METHODS: Twenty patients (mean age, 62 years) with symptomatic peripheral vascular disease were assessed with breath-hold, contrast-enhanced 3D MR angiography and catheter angiography, which served as the standard of reference. After an initial interpretation of the 3D MR angiographic data sets based only on standardized maximum intensity projections (MIP), the diagnostic gain of the stepwise addition of interactive multiplanar reformations, shaded-surface displays (SSD), and virtual intraarterial endoscopy (VIE) images was calculated. Time required for each step of postprocessing was measured. RESULTS: Pathologic changes were revealed by catheter angiography in 60 vascular segments (50 severe stenoses, seven aneurysms, and three occlusions). The average postprocessing times were MIP, 8 min (range, 5-12 min); multiplanar reformations, 9 min (range, 3-11 min); SSD, 15 min (range, 8-25 min); and VIE, 40 min (range, 18-63 min). Addition of multiplanar reformations to MIPs resulted in the greatest gain of diagnostic accuracy, from 92% to 96%, and diagnostic confidence. When analysis was based on all four techniques, receiver operating characteristic curve analysis revealed only minimal improvements in diagnostic confidence, whereas diagnostic accuracy remained unchanged at 96%. CONCLUSION: Accurate and time-effective analysis of contrast-enhanced 3D MR angiography should be based on MIP algorithms and multiplanar reformations. Additional evaluation with VIE or SSD techniques is time-consuming and provides little diagnostic gain.

Adult↗

Preliminary assessment of three-dimensional magnetic resonance imaging for various colonic disorders.

BACKGROUND: Improvements in magnetic resonance imaging (MRI) technology have enabled the acquisition of three-dimensional MRI datasets in a single breath hold. We adopted this technique to make a three dimensional intraluminal and extraluminal assessment of the colon in three patients with various colonic disorders. METHODS: One patient was studied after having a double-contrast barium enema. Two patients had MRI scans after colonoscopy, which showed three colonic tumours in one and multiple polyps in the ascending colon of the other. The process of rectal filling with 1.5-2.0 L water mixed with 15-20 mL 0.5 mol/L gadolinium-diethylenetriaminepentaacetic acid (Gd-DTPA) was monitored with MR fluoroscopic sequence. Three-dimensional datasets of the contrast-filled colon were taken with patients in prone (before and after intravenous administration of 0.1 mmol/kg bodyweight Gd-DTPA) and supine positions. 64 sections with a voxel-resolution of 2.0 x 2.0 x 1.25 mm3-were taken during a 28 s breath hold. Three-dimensional maximum intensity projection, multiplanar reconstruction, and virtual colonoscopic images of the colon were created from these. FINDINGS: Analysis of the coronal source images in conjunction with multiplanar reconstructions revealed all relevant abnormalities, including diverticula, carcinomas, and polyps. Three dimensional maximum-intensity projections gave a morphological overview of the whole colon. Targeted projections, made up of a limited number of coronal source images, showed diverticula and smaller polyps more clearly. After patients were given intravenous contrast all colonic mass lesions were enhanced. Datasets obtained in prone patients gave the best intraluminal views of the colon. Virtual magnetic resonance colonoscopy showed colonic haustra as well as the ileocaecal valve, but did not show clearly the diverticula. All intraluminal mass lesions, on the other hand, were easy to see. INTERPRETATION: The potential of three-dimensional colonic MRI to provide accurate, minimally invasive, cost-effective polyp screening, as well as comprehensive colonic tumour staging, warrants further investigation.

Aged↗