Search PubMed⌕ Search

Biomedical subjects

J C Setcos

Publications and source records attributed to J C Setcos.

At least 19 recordsLinked to original sources

Bonded amalgam restorations: current research and clinical procedure.

This paper reviews the history of amalgam bonding; compares the results of recent clinical studies to laboratory results that report reduced microleakage, increased retention, inhibition of secondary caries, reinforcement of tooth structure, and reduced cuspal deflection; discusses conservative preparation guidelines; and presents a step-by-step clinical procedure.

Composite Resins↗

Influence of the isolation method on the 10-year clinical behaviour of posterior resin composite restorations.

The aims of this prospective randomised clinical study were to clinically evaluate a radiopaque, highly filled, hybrid, light-activated resin-based composite for posterior teeth (Occlusin, ICI Dental, Macclesfield, UK and GC Dental, Tokyo, Japan) and compare the performance of restorations placed using rubber dam or cotton roll isolation. One clinician placed 100 (42 Class I and 58 Class II) restorations of the material under investigation. The isolation mode for each restoration was determined randomly: 52 preparations were protected from contamination with cotton rolls and aspiration, and 48 preparations were isolated under rubber dam. At baseline and periodically thereafter (0.5, 1, 2, 3, 4, 5, 6, and 10 years), each composite was evaluated by two practitioners using a modified (USPHS) rating system. After 10 years, 37 restorations were reviewed. The results showed satisfactory clinical performance with and without rubber dam after 10 years. A concern was the number of failures at 10 years due to unsatisfactory proximal contact. The evaluations for the surviving restorations were acceptable but with a large reduction in the percentage with ideal occlusal and proximal anatomy. The 10-year comparison of isolation modes showed no statistically significant differences (Kruskal-Wallis test) for each of the evaluation criteria. Furthermore, survival analysis showed no significant difference between the groups (Mantel-Haenszel method). It was concluded that the 10-year clinical behaviour of the restorations of a posterior composite placed under well-controlled, effective isolation with cotton rolls and aspiration, was not significantly different from the behaviour of restorations placed using rubber dam isolation.

Analysis of Variance↗

Teaching of posterior composite restorations in Japanese dental schools.

AIM: This study was conducted to assess the teaching programmes for Class I and II composite restorations in Japanese dental schools to obtain an overview of what is being taught, the relative teaching volume, the criteria for the provision of posterior composite restorations and the placement techniques taught. DESIGN: Questionnaire forms mailed to the operative dentistry teaching departments in all 29 Japanese dental schools. RESULTS: The response rate was 93 per cent, with replies from 27 of the 29 dental schools. Twenty-five (93 per cent) responding schools taught the use of Class I and two schools stated that they did not teach the use of posterior composite restorations. One of the two schools had no plan to teach posterior composites within the next five years. The other school did not answer this question. Most schools anticipated that the proportion of teaching time devoted to posterior composite restorations would increase within the next five years. Diversities and similarities between teaching programmes were noted between Japanese, North American and European dental schools, the Japanese programmes being closer to those in Europe than those in North America. CONCLUSION: The diversities in the teaching of posterior composite restorations in Japanese dental schools are as great as in other parts of the world. Such diversities must affect the overall quality of restorations in general practice.

Bicuspid↗

Cleaning dental instruments: measuring the effectiveness of an instrument washer/disinfector.

PURPOSE: To analyze the cleaning effectiveness of one type of instrument washer available for use in a dental office. MATERIALS AND METHODS: Dental instruments were heavily contaminated with blood and specific test bacteria. They were placed in cleaning baskets or within instrument cassettes, processed through the instrument washer, and analyzed for remaining blood and viable bacteria. RESULTS: Information obtained indicated that the washer is an effective cleaning system for dental instruments.

Bacteria↗

The development of resin-bonding for amalgam restorations.

Adhesive techniques are now used for many dental restorative materials, including amalgam. Several generations of dentine bonding agents have been developed, mainly for bonding composite resins. When bonding is used with amalgam restorations, the need for retention and resistance form is reduced, the seal is improved, and some procedures, such as amalgam sealants, which were not previously possible, can be considered.

Acid Etching, Dental↗

Effects of surface finish and fatigue testing on the fracture strength of CAD-CAM and pressed-ceramic crowns.

STATEMENT OF PROBLEM: All-ceramic molar crowns can be fabricated with CAD-CAM or laboratory methods with different materials, and a polished or oven-glazed surface. PURPOSE: This in vitro study determined the fracture strength of various all-ceramic crowns, with and without prior cyclic loading. MATERIAL AND METHODS: Standardized molar crowns were fabricated with a CAD-CAM machine (Cerec 2), software with machinable ceramic materials (Vita Mark II and ProCAD), and also conventional heat-pressed IPS Empress crowns fabricated at 2 dental laboratories. Groups of 40 crowns of each material were manufactured with either a polished or an oven-glazed surface finish. Cyclic loading that simulated oral conditions were performed on half of each group. Afterward, all crowns were loaded until catastrophic failure.Results. Fracture loads of the polished ProCAD crowns without prior cyclic loading was 2120 +/- 231 N, significantly higher than that of the polished Vita Mark II crowns (1905 +/- 235 N), but was not significantly different from the strength of 2 laboratory-fabricated Empress crowns. Oven-glazing of ProCAD crowns improved the fracture strength significantly, up to 2254 +/- 186 N. Prior cyclic loading decreased the strength of all tested crowns significantly, but the reduction was less for the Cerec crowns than the Empress crowns. CONCLUSION: Cerec ProCAD crowns demonstrated significantly greater strength than the Vita Mark II crowns, better resistance to cyclic loading and lower failure probability than the laboratory-fabricated IPS Empress crowns. Prior cyclic loading significantly reduced the strength of all-ceramic crowns, but had less effect on Cerec crowns than on the IPS Empress crowns. Oven-glazing of ProCAD crowns resulted in significantly higher strength and higher resistance to cyclic loading than surface polishing.

Analysis of Variance↗

Dental materials: 1997 literature review.

This review of the published literature on dental materials for the year 1997 has been compiled by the Dental Materials Panel of UK. It continues a series of annual reviews started in 1973. Emphasis has been placed upon publications, which report upon the materials science or clinical performance of the materials. The review has been divided by accepted materials classifications (fissure sealants, glass polyalkenoate cements, dentine bonding, dental amalgam, endodontic materials, casting alloys, ceramometallic restorations and resin-bonded bridges, ceramics, denture base resins and soft lining materials, impression materials, dental implant materials, orthodontic materials, biomechanics and image processing, resin composites, and casting investment materials and waxes). Three hundred and thirty three articles have been reviewed.

Dental Materials↗

Surface finish produced on resin composites by new polishing systems.

OBJECTIVE: There is a demand for more efficient and finer polishing of resin composite restorations. This study compared the use of some new systems, with new or reduced numbers of abrasive instruments, to polish representative resin composites. METHOD AND MATERIALS: Super-Snap Rainbow Technique Kit, Sof-Lex Pop-On System, and Enhance Finishing and Polishing System were used to prepare the surfaces of blocks of seven different hybrid or microfilled resin composites. For each system, three instruments were used for 30 seconds each in a standard manner. The average surface roughness of the polished surfaces was determined by profilometer. RESULTS: Visually, all surfaces were of clinically acceptable luster. By profilometer ranking, the Super-Snap Rainbow Kit produced the smoothest surfaces, followed by the Sof-Lex Pop-On System disks (which were not statistically different), and the Enhance System. CONCLUSION: The Super-Snap Rainbow Technique Kit and Sof-Lex Pop-On System provided the smoothest surfaces for all the composites tested. For several composites, the Enhance System provided less smooth surfaces, but these were also clinically acceptable.

Analysis of Variance↗

A two-year randomized, controlled clinical evaluation of bonded amalgam restorations.

PURPOSE: The clinical performance of adhesively bonded dental amalgam restorations was compared with that of traditionally placed non-bonded control amalgams in a randomized prospective study. MATERIALS AND METHODS: One-hundred thirteen Class II Dispersalloy amalgams were placed in permanent molars and premolars of 31 (21 males, 10 females) human subjects with their informed consent. By random assignment, 60 amalgam restorations were adhesively bonded using ED Primer and Panavia 21 TC (both Kuraray Co, Japan), and 53 traditional non-bonded restorations were placed. Most preparations involved replacement of defective amalgam restorations. Clinical recalls were conducted by experienced evaluators using modified USPHS criteria for occlusal and proximal anatomic form, occlusal and proximal marginal adaptation, and occlusal and proximal surface roughness. RESULTS: For the categories of anatomic form, marginal adaptation, surface quality, and temperature sensitivity, there were no significant differences between bonded and non-bonded amalgam restorations (chi-square analysis, p > 0.05). Three non-bonded restorations were lost at 4, 7, and 24 months from preparations with no deliberate retention. CONCLUSION: After two years' clinical service, there were no failures among the amalgam restorations adhesively bonded using ED Primer and Panavia 21 TC, but three non-bonded restorations failed due to lack of retention. For traditional preparations, adhesively bonded amalgams of the type investigated perform as well as non-bonded amalgams over two years' clinical service.

Bicuspid↗

Dental materials: 1996 literature review.

This critical review of the published literature on dental materials for the year 1996 has been compiled by the Dental Materials Panel of the UK. It continues the series of annual reviews started in 1973 and published in the Journal of Dentistry. Emphasis has been placed upon publications which report upon the materials science or clinical performance of the materials. The review has been divided by accepted materials classifications (fissure sealants, glass polyalkenoate cements, dentine bonding, dental amalgam, endodontic materials, casting alloys, resin-bonded bridges and ceramo-metallic restorations, ceramics, denture base resins and soft lining materials, impression materials, implants materials, orthodontic materials, biomechanics and image processing, resin composites and casting investment materials and waxes). Three hundred and thirteen articles have been reviewed.

Dental Alloys↗

Dental materials: 1996 literature review. Part 2.

This critical review of the published literature on dental materials for the year 1996 has been compiled by the Dental Materials Panel of the UK. It continues the series of annual reviews started in 1973 and published in the Journal of Dentistry. Emphasis has been placed upon publications which report upon the materials science or clinical performance of the materials. The review has been divided by accepted materials classifications (fissure sealants, glass polyalkenoate cements, dentine bonding, dental amalgam, endodontic materials, casting alloys, resin-bonded bridges and ceramo-metallic restorations, ceramics, denture base resins and soft lining materials, impression materials, implants materials, orthodontic materials, biomechanics and image processing, resin composites and casting investment materials and waxes). Three hundred and thirteen articles have been reviewed.

Ceramics↗

Antimicrobial activities of dental impression materials.

OBJECTIVE: The aim of this study was to measure the in vitro killing effects five commercial alginate impression materials had on five test microorganisms. METHODS: Two alginates with no added disinfectant, one supplemented with chlorhexidine and two others containing quaternary ammonium compounds were tested. Challenge microbes included two gram-positive cocci, two gram-negative bacilli and a yeast. Saline solutions containing standardized concentrations of test microbes were used to mix the alginates. Some set specimens were immediately homogenized and the resulting fluids diluted and spread plated. Other specimens were processed 30 or 60 min after setting. After culturing, the numbers of colonies were counted and the levels of microbial reductions determined. RESULTS: Unsupplemented alginates had no antimicrobial effects. The quaternary-ammonium-containing alginates were completely effective against all five test microorganisms. The alginate with chlorhexidine killed all the gram-negative bacilli and the majority (95-99%) of the gram-positive cocci and yeast. SIGNIFICANCE: Results indicated that disinfectant-containing alginate impression materials could reduce the number of soiling microorganisms present on and within test specimens.

Alginates↗

Single-use, disposable, presterilized light-activation probe: the future?

OBJECTIVE: The purpose of this study was to compare a single-use, disposable, presterilized light activation probe with an equivalent autoclavable probe. Light output, heat generation, and depth of cure were investigated. METHOD AND MATERIALS: Ten disposable and two reusable probe tips were tested. Three maximum light output readings for each tip were recorded with a radiometer. Heat generation at the probe tip was recorded, at 30-second intervals over a five-minute period, with a thermocouple probe placed under a 3-mm-thick glass slide. After light-activated "compomer" was placed in a sectional two-piece stainless steel mold and cured, depth of cure was evaluated using the scrape technique. RESULTS: With respect to light output and depth of cure, there were no statistically significant differences between probe types, but the disposable probe generated significantly less heat. CONCLUSION: The disposable probe performed clinically as well as an autoclavable counterpart with respect to light output, heat generation, and depth of cure.

Dental Instruments↗

Impression materials and techniques for crown and bridgework: a survey of undergraduate teaching in the UK.

The aim of this study was to document the teaching of impression materials and techniques for crown and bridgework in the undergraduate curriculum in UK dental schools. A questionnaire sent to each school during the 1993/1994 academic year elicited fourteen replies (100% response). Addition-cured silicones were found to predominate; 71% of schools taught and used clinically a one-stage, full arch impression technique involving stock trays, and 57% of schools a full-arch custom tray technique. Routine disinfection of impressions was taught and practised in 43% of schools. The results demonstrated variation between UK dental schools in their teaching of impression materials and techniques for crown and bridgework in the undergraduate curriculum.

Crowns↗

A split-shank prefabricated post system: a critical multidisciplinary review.

A multidisciplinary panel of senior academics and practitioners has evaluated a system of prefabricated threaded split-shank posts (Flexi-Post/Flexi-Flange) from published research and their own clinical use. These posts have been compared with requirements of an ideal post system in relation to clinical use, stress effects, stress distribution, retention, loosening and displacement, provision for cores, and biocompatibility. The purpose was to provide this critical review to allow interested clinicians to compare this novel design to other available post systems.

Dental Prosthesis Design↗

Antimicrobial abilities of various dentine bonding agents and restorative materials.

OBJECTIVES: The purpose of this study was to observe and measure the in vitro effect of various composite restorative materials and dentine bonding agents on the growth and adherence of oral bacterial believed to be responsible for recurrent caries in humans and on micro-organisms commonly used to evaluate the effectiveness of disinfecting agents. METHODS: Five sets of dentine bonding agents and composite resins and ten species of micro-organisms were used. Circular disc specimens of each composite set were placed onto inoculated plates. Zones of growth inhibition around specimens were measured after incubation. On other plates, specimens were placed alone for 48 h, removed, and then the micro-organisms added. Also, the composite sets were placed into sterilized bovine incisors and suspended into sucrose-containing both inoculated with Streptococcus mutans for 3 days. Adhering materials were disclosed and scored. RESULTS AND CONCLUSIONS: Four of the composites sets produced statistically similar (P > 0.05) inhibitory zones. The Gram-negative rods and the Staphylococcus aureus were the most resistant micro-organisms. The five composites sets produced the same (P > 0.05) reduction in bacterial accumulation (> 60%). Aging of the specimens in water for periods up to 4 weeks prior to exposure to S. mutans did not affect product activity.

Acrylic Resins↗