Search PubMed⌕ Search

Biomedical subjects

I Moussa

Publications and source records attributed to I Moussa.

At least 55 records · Page 3Linked to original sources

Plaque removal prior to stent implantation in native coronary arteries: why? When? And how?

Coronary stenting has significantly reduced restenosis in focal de novo coronary lesions, but its impact in complex lesions has been less pronounced. Recent data suggest a possible role for pre-intervention plaque burden in exacerbating neo-intimal hyperplasia after stent implantation. These observations formed the basis for the hypothesis that plaque removal prior to stent implantation, using directional atherectomy in non-calcified lesions and rotational atherectomy in calcified lesions, may reduce restenosis. The currently available non-randomized experience that used this approach has shown its feasibility and favourable long-term outcome when applied in selected patients. However, the incidence of non-Q-wave myocardial infarction is increased with both rotational and directional atherectomy compared to PTCA or stent alone. The utilization of potent antiplatelet agents and/or the development of new atherectomy devices that produce lower embolization rate may decrease the incidence of these ischaemic complications. In addition, considering the increased procedural time and cost, this approach will have to be applied in selected patient subsets where debulking or stenting as a stand-alone strategy is associated with a high restenosis rate. Randomized clinical trials testing the usefulness of this approach, with both rotational and directional atherectomy, are currently in progress.

Angioplasty, Balloon, Coronary↗

Persistent High Restenosis After Local Intrawall Delivery of Long-Acting Steroids Before Coronary Stent Implantation.

OBJECTIVE: This pilot study was performed to evaluate the feasibility and safety of intrawall delivery of long acting steroids before stent implantation, testing the efficacy of this treatment in reducing intimal hyperplasia in lesions at high risk for restenosis. METHODS: In 24 patients (40 lesions) local intrawall drug delivery of methylprednisolone acetate, using a new catheter device, was attempted before elective stent implantation. Treated lesions were compared to a matched control group. RESULTS: Lesions were classified AHA/ACC type C in 47% of cases, had a mean lesion length of 13.6 +/- 9.1 mm, and a mean vessel diameter of 2.85 +/- 0.44 mm. In 9 cases (25%) chronic total occlusions were treated. Methylprednisolone acetate (mean 60 +/- 23 mg) was delivered in 36 lesions (21 patients; delivery success 90%) in the remaining 4 lesions (10%) the delivery device did not cross the lesion. After drug delivery 46 stents were implanted (1.2 stent/lesion; stented segment length 30.1 +/- 18.8 mm) using high pressure for stent expansion (mean 16.4 +/- 3.1 atm). Intracoronary ultrasound guidance was used in 64% of cases. Procedural and in-hospital complications were: Two non Q wave myocardial infarctions (8%) and one (3%) subacute stent thrombosis. Angiographic follow-up was obtained in all 36 treated lesions (100%) and the angiographic restenosis rate (³ 50% diameter stenosis) was 39%. A reduction of the incidence of restenosis compared to the matched control group was not observed. CONCLUSIONS: Long acting steroids could be delivered locally with high success and low complication rates. The restenosis rate remained high in a subset of unfavorable lesions with high risk for restenosis.

Journal Article↗

Long-term angiographic and clinical outcome of patients undergoing multivessel coronary stenting.

BACKGROUND: Randomized clinical trials have shown that multivessel coronary angioplasty is feasible and provides similar long-term survival as bypass surgery in selected patients. However, the higher need for repeat intervention, in particular, coronary artery bypass graft surgery, remains a problem. The objective of this study was to test the hypothesis that multivessel stenting is safe and effective in reducing the need for repeat interventions, in particular, the need for bypass surgery. METHODS AND RESULTS: Between March 1993 and June 1995, 100 consecutive patients (243 lesions) had multivessel coronary stenting. High-pressure stent optimization was used in all patients. Procedural success was achieved in 97% of lesions; 2 patients (2%) required emergency bypass surgery. Angiographic follow-up was obtained in 89% of patients at 5.2+/-2.5 months. Angiographic restenosis occurred in 22% of the lesions, but 37% of patients had > or = 1 lesion with restenosis. Clinical follow-up was obtained in all patients at 21 +/- 10 months: target lesion revascularization was needed in 30 patients (30%), repeat angioplasty in 28 patients (28%) and coronary bypass surgery in 2 patients (2%); the overall survival rate was 96% (2% noncardiac death). CONCLUSIONS: Multivessel coronary stenting can be performed with high success rate and low need for emergency bypass surgery. Compared with historical results with multivessel percutaneous transluminal coronary angioplasty, patients who undergo multivessel stenting need less repeat interventions, in particular, less coronary bypass surgery and have similar long-term survival.

Aged↗

Coronary stenting after rotational atherectomy in calcified and complex lesions. Angiographic and clinical follow-up results.

BACKGROUND: Treatment of calcified (in contrast to simple) lesions with PTCA has been associated with a lower success rate and more procedural complications. Rotablation can improve acute results, but the high restenosis rate remains a problem. The purpose of this study was to evaluate the clinical and angiographic outcome of patients with complex and calcified lesions treated with a combination of rotablation and stenting. METHODS AND RESULTS: Seventy-five consecutive patients with 106 lesions had rotablation prior to coronary stenting. Intravascular ultrasound-guided stenting was used without subsequent anticoagulation in 93% of patients. Procedural success was achieved in 93.4% of lesions. Acute stent thrombosis occurred in two lesions (1.9%), and subacute stent thrombosis in one lesion (0.9%). Angiographic follow-up was performed in 82.5% of lesions at 4.6 +/- 1.9 months with an angiographic restenosis rate of 22.5%. Clinical follow-up was performed in all patients at 6.4 +/- 3 months; target lesion revascularization was needed in 18% of lesions; Q-wave myocardial infarction occurred in 1.3%, coronary bypass surgery in 4.0%, and death in 1.3%. CONCLUSIONS: Optimal coronary stenting after rotablation in calcified and complex lesions can be performed with a high success rate, an acceptable rate of procedural complications, and a low rate of stent thrombosis. This approach was associated with a low incidence of angiographic restenosis compared with results usually obtained with other interventional strategies in calcified and complex lesion subsets.

Aged↗

A method to eliminate articulation from the Palmaz-Schatz stent delivery system.

It has been shown that the articulation site in the Palmaz-Schatz stent is a frequent site for restenosis. In this communication, we report on a new method to eliminate the articulation site in the Palmaz-Schatz stent to provide better lesion coverage and decrease the probability of plaque prolapse at the articulation site. We believe that this method is simple and effective, and that it serves an important clinical purpose.

Angioplasty, Balloon↗

New approach to quantitative angiographic assessment after stent implantation.

The new generation quantitative angiographic systems apply the interpolated technique to calculate the reference diameter at the site of the stenosis by integrating measurements of the segments proximal and distal to the stenosis. After stent implantation these measurements can be misleading as the treated segment, which is frequently larger than the adjacent not stented segments, is included in the measurements. The consequence is an overestimation of the reference diameter and the residual diameter stenosis. The present study was performed to compare this conventional technique of measurement with a new method which excludes the stented segment for the calculation of the reference diameter. Fifty-two lesions treated with poorly radiopaque stents (56% Palmaz-Schatz, 28% NIR, 10% Gianturco-Roubin, 6% Wallstent) expanded at high pressure (> = or 16 atm) were analyzed according to the conventional and stent excluded method. After stent implantation the reference diameter was 3.39 +/- 0.48 mm with conventional measurements and 3.02 +/- 0.45 mm with the stent excluded method (P < 0.05). The corresponding % diameter stenosis was 13 +/- 9 for the conventional technique and 1 +/- 13 for the stent excluded analysis (P < 0.05). The new approach to quantitative coronary analysis after stenting provides higher accuracy in reference diameter calculations and allows a more appropriate matching of stented segments with adjacent normal segments.

Angioplasty, Balloon, Coronary↗

New stent delivery balloon: a technical note.

This study reports the first clinical application of a new noncompliant balloon composed of a middle polyurethane layer sandwiched between an inner layer of polyethylene terephtalate and an outer membrane that provides for consistent even expansion. With this balloon design, the very low compliance and high pressure resistance of polyethylene terephthalate are associated with the high elasticity of polyurethane, preventing balloon damage from stent crimping and expansion and allowing a firm embedding of the stent struts. Palmaz-Schatz stent implantation was successful in 33/35 stents (94%), and the two stents that could not be advanced up to the lesion were successfully withdrawn. High pressure expansion of the stent was obtained during deployment with no balloon ruptures at inflation pressures equal or lower than 16 atmospheres (atm). Accurate positioning of the stent was facilitated by the two markers at the balloon ends and by the optimal visualization after contrast injection, even with 6 Fr guiding catheters. This new delivery system maintains the advantages of hand-crimped stents on noncompliant balloons, reducing the risk of stent loss.

Angioplasty, Balloon↗

Subacute stent thrombosis in the era of intravascular ultrasound-guided coronary stenting without anticoagulation: frequency, predictors and clinical outcome.

OBJECTIVES: This study was performed to determine predictors of subacute stent thrombosis (SST) in the era of intravascular ultrasound (IVUS)-guided coronary stenting without anticoagulation. BACKGROUND: The incidence of stent thrombosis has declined with the application of high pressure stent deployment with only antiplatelet therapy. However, no data are available on predictors of stent thrombosis in this era. METHODS: Between March 30, 1993 and July 31, 1995, 1,042 consecutive patients underwent coronary stenting without anticoagulation. For this analysis, we excluded patients who underwent coronary artery bypass surgery, died or had acute stent thrombosis within the 1st 24 h after stenting (41 patients). A total of 1,001 patients (1,334 lesions) were included; 982 patients (1,315 lesions) without SST and 19 patients (19 lesions) with SST. RESULTS: The rate of SST was 1.9% (per patient). There was no difference between the SST and No SST groups in rescue stenting (12% vs. 13.5%, p = 1.0) or mean +/- SD reference diameter (3.11 +/- 0.58 vs. 3.19 +/- 0.53 mm, p = 0.54). A preexisting thrombus was present in 12% of the SST group and in 4.5% of the No SST group (p = 0.19). Predictors of SST by univariate analysis were low ejection fraction (p = 0.004), more stents per lesion (p = 0.049), use of combination of different stents (p = 0.012), smaller balloon size (p = 0.012) and suboptimal result in terms of smaller lumen dimensions by angiography (p = 0.016) and IVUS (p = 0.004), residual dissections (p = 0.027) and slow flow (p = 0.0001). In stepwise logistic regression analysis, ejection fraction (p = 0.019), use of a combination of different stents (p = 0.013) and postprocedure dissections (p = 0.014) and slow flow (p = 0.0001) were predictive of SST. CONCLUSIONS: In the present era of stent implantation, factors that may predispose to SST are low ejection fraction, intraprocedural complications leading to utilization of more stents, particularly with different stent designs, and suboptimal final result in terms of smaller lumen dimensions and persistent slow flow and dissections.

Anticoagulants↗

Long-term clinical follow-up after successful repeat percutaneous intervention for stent restenosis.

OBJECTIVES: This study evaluated the long-term clinical outcome of successful repeat percutaneous intervention after in-stent restenosis. BACKGROUND: Recurrence of symptoms and angiographic restenosis after stent implantation are observed in 15% to 35% of cases. Repeat percutaneous treatment for in-stent restenosis has been shown to be safe, with high immediate success, but little is known about the long-term clinical outcome. METHODS: Clinical follow-up (minimum 9 months) was obtained in a consecutive series of 124 patients (127 vessels) presenting with stent restenosis who were successfully treated with repeat percutaneous intervention. RESULTS: Clinical follow-up was obtained in all 124 patients at a mean [+/-SD] of 27.4 +/- 14.7 months (range 9 to 66); a stress test was available in 88 patients (71%). Recurrence of clinical events occurred in 25 patients (20%) and included death from any cause in 2 patients (2%), target vessel revascularization in 14 (11%), myocardial infarction in 1 (1%) and positive stress test results or recurrence of symptoms (Canadian Cardiovascular Society class I to IV) treated medically in 8 (6%). Cumulative event-free survival at 12 and 24 months was 86.2% and 80.7%, respectively. Significant predictive factors of recurrence of clinical events were repeat intervention in saphenous vein grafts, multivessel disease, low ejection fraction and a < or = 3-month interval between stent implantation and repeat intervention. CONCLUSIONS: In-stent balloon angioplasty for stent restenosis in native vessels seems to be an effective method in terms of a low long-term clinical event rate.

Aged↗

Intracoronary stent implantation in native coronary arteries and saphenous vein grafts: a consecutive experience with six types of stents without prolonged anticoagulation.

OBJECTIVE: To analyze the results of implantation of six different intracoronary stents without the use of prolonged anticoagulation. MATERIAL AND METHODS: Between Mar. 30, 1993, and Jun. 30, 1995, 889 patients with 1,194 coronary or vein graft lesions underwent implantation of one of six types of stents-Palmaz-Schatz, Gianturco-Roubin, Wiktor, Micro, Cordis, or Wallstent. The patients were classified into seven groups on the basis of the type of stent that was implanted, including one group with combined use of two or more types of stents. Among the 851 patients with successful stent delivery and without major complications, 801 received only antiplatelet therapy, and 50 received a standard anticoagulation regimen. One-month clinical followup data were obtained in all patients, and clinical events were investigated. RESULTS: The mean number of stents was 1.8 per lesion and 2.4 per patient. Procedural success was achieved in 93% of the lesions. The clinical success rate at 1 month was 90%. Intravascular ultrasound assessment was performed in 90% of the lesions. The final minimal luminal cross-sectional area of the stent increased from 6.8 to 7.8 mm2 after intravascular ultrasound-guided optimization. Within 1 month, 16 stent thrombosis events (1.9%) occurred. No significant differences were noted in stent thrombosis rates among the various stent cohorts. Multivariate logistic regression analysis revealed that the final stent minimal luminal diameter measured by intravascular ultrasonography was the only variable associated with stent thrombosis. CONCLUSION: This study showed that six different stents could possibly be inserted without subsequent anticoagulation if optimal stent expansion and total lesion coverage were achieved.

Anticoagulants↗

First experience with imaging core wires.

This study is the first assessment of feasibility and clinical usefulness of an imaging wire. The device used is a 0.018" flexible cable mounting a 30 MHz piezoelectric crystal at the end. The only possible application of the wire in its current configuration is the assessment of balloon expansion with over-the-wire balloon catheters. In this study, 17 lesions were examined in 14 patients. Despite careful removal of the air, no image could be obtained with the balloon deflated or through the shaft of conventional balloon catheters. When the balloon was inflated to 1-4 atm the circular echo-free cross-section of the balloon became visible, surrounded by the dense line of the balloon membrane and by the vessel wall. By examining the stent area at different balloon pressures, it was possible to determine the stent recoil between maximal balloon expansion and lowest balloon pressure allowing a readable ultrasound image. These encouraging preliminary observations confirm the feasibility of the use of an ultrasound guidewire for monitoring balloon expansion during stent implantation. After high pressure inflation, a moderate reduction of the stent lumen was observed during deflation, compatible with the small recoil predicted for the stainless-steel mesh stent used.

Angioplasty, Balloon, Coronary↗

Subacute stent thrombosis and the anticoagulation controversy: changes in drug therapy, operator technique, and the impact of intravascular ultrasound.

Clinical trials have shown that stents are superior to other catheter-based coronary interventions in terms of reduced complications and improved long-term efficacy. With utilization of high-pressure balloon inflation and intravascular ultrasound (IVUS) guidance, stent implantation can now be performed safely without anticoagulation (i.e., with lower rates of stent thrombosis and vascular complications). In 2 recent prospective clinical trials, stent thrombosis occurred in 3.5% of cases despite anticoagulant therapy, which resulted in an average of 7% vascular and bleeding complications. Initial use of IVUS during traditional stent deployment showed that 80% of stents were underexpanded and led to the hypothesis that stent thrombosis might be decreased as a result of optimal stent placement under IVUS guidance without the need for anticoagulation. In a prospective clinical trial to test this hypothesis, three factors were found to reduce stent thrombosis: full stent expansion, complete apposition to the vessel wall, and full lesion coverage. Predictors of thrombotic risk in this era of high-pressure stent deployment without anticoagulation include low ejection fraction, residual dissections, slow flow, multiple stents per lesion, and smaller postprocedure stent luminal diameter. To optimize stent expansion, stent dilation should be performed using a mean inflation pressure of 18 atm with a noncompliant or minimally compliant balloon sized to the vessel being treated (B/V ratio = 1.1). Controversy still remains about the best poststent antiplatelet regimen, and results of a recent trial should indicate whether heparin coating provides additional protection from stent thrombosis.

Anticoagulants↗

Variability in tissue characterization of atherosclerotic plaque by intravascular ultrasound: a comparison of four intravascular ultrasound systems.

Different intravascular ultrasound (IVUS) systems vary in their image presentation. The purpose of this study was to compare four IVUS systems in vitro to determine the accuracy of tissue characterization of atherosclerotic plaque compared with histology. Ninety-eight plaque segments from 23 formalin-fixed human iliac arteries were imaged in saline at room temperature with four different IVUS systems. To assess the accuracy of IVUS in describing plaque, three types of analysis were performed: (1) the ability to identify the presence and extent of lumen or plaque boundary; (2) sensitivity, specificity, and interobserver variability of IVUS in qualitatively identifying plaque components compared with histology; and (3) quantification of calcification. The synthetic aperture device had a lower sensitivity in identifying lumen and plaque boundaries (87%, 38% respectively) compared with other machines (96%-100%, 95%-100%). All three mechanically rotating systems had fair to good sensitivities for identifying calcification (57%-73%) or lipid filled areas (50%-83%). The sensitivity of discriminating fibrous tissue from fatty areas was low (39%-52%). The synthetic aperture system had a significantly lower sensitivity for identifying all three tissue types (4%-21%). There was significant interobserver variability (kappa value = 0.47-0.68) as well as machine to machine variability (kappa value = 0.52) for tissue characterization. Calcified areas were underestimated by System 1 (p < .05) and System 4 (p < .01) because of weaker echo reflections or poor image quality. There are significant differences in image representation among these four IVUS systems in the diagnosis of tissue components of complex atherosclerotic plaque. These variabilities should be considered when interpreting studies performed with different machines.

Adolescent↗

Early histogenesis in human embryonic liver.

The present study reports the results of a light microscopy study on the early histogenesis of human liver. 18 human embryos in the age range of 6 to 10 gestational week were studied. The embryos were provided by the Department of Obstetrics and Gynecology following an abrasion in normal pregnancy. The embryonic liver was studied using conventional histologic technique, histochemical methods for lipids and glycogen detection: by enzyme chemical methods for establishing the activity of the enzymes lactatedehydrogenase (LDH) and succinatedehydrogenase (SDH). The hepatocytes and the basic five types of differentiating cells of mesenchymal origin of the liver were studied: hemopoietic cells, macrophages, endothelial cells, fibroblasts and smooth muscle fibres. Increased activity of the two dehydrogenases and an intensive reaction for glycogen in the hepatocytes and myoblasts were observed; for the other cell types the reaction was distinctly weaker. The obtained data could be associated with the changes in the metabolism of the differentiating cells at the beginning of the hepatoorganogenesis.

Cell Division↗

Improved exercise test accuracy using discriminant function analysis and "recovery ST slope".

The objective of the study was to optimize the accuracy of the exercise test for predicting the presence of significant angiographic coronary artery disease. A retrospective analysis of stored digital exercise electrocardiographic data on 147 men who had undergone exercise testing and cardiac catheterization was performed. With significant coronary artery disease defined as > or = 70% stenosis, 95 patients had one or more vessel(s) diseased. None were receiving digoxin, had a myocardial infarction or previous coronary artery bypass graft, or exhibited left bundle branch block, left ventricular hypertrophy, Q waves, or ST depression on their resting electrocardiogram. Analysis was performed using the authors' averaging and measurement software at rest and at each 30 seconds throughout the exercise and recovery in leads II, V2, and V5. Discriminant function analysis was used to analyze pretest variables, as well as hemodynamic and electrocardiographic changes and symptoms during exercise. A discriminant function score was developed and compared to other treadmill scores. The setting was a 1,000 bed Veterans Affairs Medical Center (Long Beach, CA). Discriminant function analysis chose age, smoking status, presenting chest pain characteristics, and lead V5 ST slope in recovery to have independent power for separating those with and without coronary artery disease. A discriminant function score using these four variables was used to form a receiver operating characteristics curve (and derive receiver operating characteristics curve areas) for comparison to other exercise test methods and scores: (discriminant function score = .81; slope 3.5 minutes into recovery in lead V5 = .73; traditional ST amplitude method = .72; ST60/HR index (amplitude of ST depression 60 ms after the J point/delta heart rate) = .66; traditional ST amplitude/HR index (traditional method/delta heart rate) = .75; Hollenberg score = .68; Hollenberg areas only = .66; and ST integral = .66. Receiver operating characteristics curve analysis revealed a trend for the discriminant function score to be superior to all other measurements and scores. Recovery ST slope in lead V5 performed as well as or better than all other electrocardiographic criteria or treadmill scores except for the authors' discriminant function score.

Cardiac Catheterization↗