Search PubMed⌕ Search

PubMed · 8409814

Improved exercise test accuracy using discriminant function analysis and "recovery ST slope".

Abstract

The objective of the study was to optimize the accuracy of the exercise test for predicting the presence of significant angiographic coronary artery disease. A retrospective analysis of stored digital exercise electrocardiographic data on 147 men who had undergone exercise testing and cardiac catheterization was performed. With significant coronary artery disease defined as > or = 70% stenosis, 95 patients had one or more vessel(s) diseased. None were receiving digoxin, had a myocardial infarction or previous coronary artery bypass graft, or exhibited left bundle branch block, left ventricular hypertrophy, Q waves, or ST depression on their resting electrocardiogram. Analysis was performed using the authors' averaging and measurement software at rest and at each 30 seconds throughout the exercise and recovery in leads II, V2, and V5. Discriminant function analysis was used to analyze pretest variables, as well as hemodynamic and electrocardiographic changes and symptoms during exercise. A discriminant function score was developed and compared to other treadmill scores. The setting was a 1,000 bed Veterans Affairs Medical Center (Long Beach, CA). Discriminant function analysis chose age, smoking status, presenting chest pain characteristics, and lead V5 ST slope in recovery to have independent power for separating those with and without coronary artery disease. A discriminant function score using these four variables was used to form a receiver operating characteristics curve (and derive receiver operating characteristics curve areas) for comparison to other exercise test methods and scores: (discriminant function score = .81; slope 3.5 minutes into recovery in lead V5 = .73; traditional ST amplitude method = .72; ST60/HR index (amplitude of ST depression 60 ms after the J point/delta heart rate) = .66; traditional ST amplitude/HR index (traditional method/delta heart rate) = .75; Hollenberg score = .68; Hollenberg areas only = .66; and ST integral = .66. Receiver operating characteristics curve analysis revealed a trend for the discriminant function score to be superior to all other measurements and scores. Recovery ST slope in lead V5 performed as well as or better than all other electrocardiographic criteria or treadmill scores except for the authors' discriminant function score.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Rodriguez, I Moussa, J Froning, M Kochumian, V F Froelicher. 1993. Improved exercise test accuracy using discriminant function analysis and "recovery ST slope".. https://doi.org/10.1016/0022-0736(93)90039-g

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Initial experience with the Cardiva Boomerang vascular closure device in diagnostic catheterization.

OBJECTIVES: The authors studied the safety and efficacy of the Cardiva Boomerang vascular closure device in patients undergoing diagnostic cardiac catheterization. BACKGROUND: Conventional vascular closure devices (sutures, collagen plugs, or metal clips) have been associated with catastrophic complications including arterial occlusion and foreign body infections; furthermore, they cannot be utilized in patients with peripheral vascular disease or vascular access site in a vessel other than the common femoral artery. The Cardiva Boomerang device facilitates vascular hemostasis without leaving any foreign body behind at the access site, can be used in peripheral vascular disease, and can be used in vessels other than the common femoral artery METHODS: A total of 96 patients undergoing transfemoral diagnostic cardiac catheterization were included in this study, including 25 (26%) patients with contraindications to conventional closure devices. Femoral angiography was performed prior to deployment of the Cardiva Boomerang closure device. Patients were ambulated at 1 hr after hemostasis was achieved. RESULTS: The device was successfully deployed and hemostasis achieved with the device alone in 95 (99%) patients. The device failed to deploy in 1 (1%) patient and required conversion to standard manual compression. Minor complications were observed in 5 (5%) patients. No patients experienced major complications including femoral hematoma > 4 cm, red blood cell transfusion, retroperitoneal bleed, arteriovenous fistula, pseudoaneurysm, infection, arterial occlusion, or vascular surgery. CONCLUSIONS: The Cardiva Boomerang device is safe and effective in patients undergoing diagnostic cardiac catheterization using the transfemoral approach, facilitating early ambulation with low rates of vascular complications.

Cardiac Catheterization↗

Acute ST elevation myocardial infarction in pregnancy due to coronary vasospasm: a case report and review of literature.

Acute myocardial infarction during pregnancy is rare but may be associated with high risk complications. We present a very rare case about an acute myocardial infarction with anterior ST elevation in a 40-year-old woman, at 38th week of gestational period. The coronary arteriograms showed a diffuse left coronary vasospasm. The coronary arteriography at puerperium showed no organic narrowings. This is the first case with a well documented coronary artery vasospasm in pregnancy. Management should follow the usual principles of care for acute myocardial infarction. However, selection of diagnostic and therapeutic approaches may be greatly influenced by fetal safety.

Cardiac Catheterization↗

Comparison of performance characteristics between new and reprocessed electrophysiology catheters.

OBJECTIVE: Electrophysiology (EP) catheter reprocessing is widespread and previous studies have examined clinical performance, sterility and safety of these reprocessed devices. Here we compare the intrinsic engineering characteristics, electrical, mechanical and safety, between new and reprocessed devices. MATERIALS AND METHODS: New (58 devices) and clinically used (five times)/reprocessed (165 devices) EP catheters from five manufacturers were employed to examine and compare catheter electrode continuity, electrode isolation, electrical leakage current, shaft torsion and stiffness characteristics as well as tip buckling and bond strengths. RESULTS: Electrode continuity, isolation and leakage currents for both new and reprocessed EP catheters were within acceptance criteria for electrode continuity (<30 Omega) and shaft electrical leakage (<0.5 mA) as well as electrode isolation (>200 Omega). In addition, reprocessed catheters were equivalent when compared with their new counterparts. While catheter shaft torque forces varied five fold amongst manufacturers, comparison between new and reprocessed devices within a manufacturer showed no significant differences. Likewise shaft stiffness showed no significant difference between new and reprocessed devices. Average tip buckling forces for all catheters were substantially below the acceptance criteria of 0.45 lb (between 0.04 and 0.1 lb) with differences between new and reprocessed catheters not being significant. All bond strengths for both new and reprocessed catheters exceeded the acceptance criteria specified in ISO 10555-1. CONCLUSIONS: This study found that reprocessed EP catheters which had undergone five actual clinical use/reprocessing cycles met and exceeded acceptance criteria specified by industry standards as well as individual manufacturer's criteria for both electrical and safety characteristics. We conclude that reprocessed EP catheters exhibit electrical, mechanical and safety characteristics which are equivalent to their new counterparts.

Cardiac Catheterization↗