Search PubMed⌕ Search

Biomedical subjects

H Wuthe

Publications and source records attributed to H Wuthe.

54 records · Page 3Linked to original sources

[Computer measurement of residual volume and alveolar gas distribution parameters in epidemiological studies (author's transl)].

Starting from the quick helium-rebreathing-technique of Kowalski-Visser a method of combined measurement of residual volume and closing volume in one test was developed using automatic data - collection in 3 different variants, that is- automatic control during test- manual control during test and- manual control on the table. A computer program running on minicomputer Cellatron 8205 is described. Experiences using the different program-variants are discussed.

Diagnosis, Computer-Assisted↗

[Functional diagnosis of CNSLD in epidemiological surveys-results of the population study in Halle 1974 (author's transl)].

The problems of lung function testing methods in epidemiological studies were assessed in a study population of 853 men aged 40-70. The Helium-rebreathing-method, the X-ray densitometry, the oxygen-method were evaluated for the estimation of the residual volume in epidemiological conditions. The Pneumotest was proved for measurement of unequal ventilation. The necessity of reference values for these methods is discussed.

Adult↗

[Automated analysis of changes in parameters of lung mechanics with alterations in breathing frequency, lung volume, and physical effort (author's transl)].

Changes in parameters of respiratory mechanics with alteration in breathing frequency, lung volume and physical effort were determined in 23 subjects using automated data collection and data processing. Resistance R, Compliance C and work of breathing W show great dependence on breathing frequency and lung volume. An objective measuring of their changes during exercise requires a constant lung volume and a standardized breathing frequency. Parameters R and C and the maximal pressure amplitude DPM divided by the tidal volume VT show no significant alterations in several degrees of exercise. Work of breathing and work of breathing per tidal volume are enhanced significantly with increasing exercise. These parameters may estimate the mechanics of breathing better than R and C in patients with dyspnea during exercise.

Automation↗

[Rapid test for quantitative proof of emphysema].

For the purpose of an aimed diagnostics near to practice of unspecific chronic pulmonary diseases a measuring place was developed, by means of which with simple performance of the experiments and short examination-time the determination of vital capacity, forced expiratory volume, maximal breathing capacity, the measurement of the O2-tension of the arterialised ear blood and the determination of the residual volume are possible. The determination of the residual volume is performed according to the classical O2-N2-gasmixture method using the spirotest device in connection with a bag-box system and the PO2-micro-measuring chamber. On 63 patients the residual volume was determined in this measuring place and compared with the rapid He-re-breathing method. The correlation analysis between the RVbody%TK- and the RVO2% TK-values with a correlation coefficient r = 0,887 ascertains the reliability of the demonstrated method. The results of a epidemiological study on 422 test persons on account of the close correlation between RVHe % TK and RVO2% TK with r = 0.62 prove the usability for examinations of the population.

Airway Resistance↗

[Screening tests for the determination of risk groups in respiratory insufficiency under conditions of epidemiological serial studies].

A report is given on a system of effective respiratory functional tests which proved its value when used in epidemiological mass examinations in connection with the mass miniature radiography in Berlin, Brandenburg and Halle as well as in mass examinations in Berlin enterprises. Thereby a new development - Pneumotest - is presented, an electronic spirometer for the recognition of ventilatory and distribution analytic preliminary parameters with digital indication of 5 sizes of the breath test manoeuvre which is to be applied as successor of the well-known spirotest device. In this paper the functional capacity of the further developed fluorographic densimetry as preliminary emphysematic test is proved. The application of the rapid helium or O2/N2 breathing back technique for the determination of residual volume and closing volume has in connection with the automatic establishment of the measuring values proved as basic diagnostics for emphysema with a large efficiency and at the same time with high reliability. The digestion of the epidemiological functional data with the help of electronic data processing is carried out in the own microcalculator system following immediately the application during examination.

Humans↗

Comparison of the helium rebreathing method and the x-ray film densitometry in epidemiological screening tests of CNSLD (author's transl).

Two methods for the examination of the residual volume were compared under the special conditions of epidemiological studies. The X-ray Photo Densitometry RV/TLC is measured as a quotient of the brightness of the lung radiographs during inspiration and expiration maximums. The Helium Rebreathing method is a gas mixture technique. The correlation between both methods proved to be significant (r = 0,60). The advantages and disadvantages of these methods for epidemiological studies were discussed.

Absorptiometry, Photon↗