Coping with congenital blindness.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to H Turner.
Explore the source record for details and available documents.
Rapid uptake of F-18 FDG was observed in a variety of transplanted and spontaneous tumors in animals. The tumor uptake reached a peak by 30 min and remained relatively constant up to 60 min, with a very slow wash-out of F-18 activity from the tumor thereafter. Tumor-to-normal tissue and tumor-to-blood ratios ranged from 2.10-9.15 and 2.61-17.82, respectively, depending on the type of tumor. A scintiscan of a seminoma in a dog showed very high uptake in the viable part and lack of uptake in the necrotic mass. Toxicological studies in mice using 1000 times human tracer dose (HTD) per wk for 3 wk and in dogs using 50 times HTD per wk for 3 wk did not show any evidence of acute or chronic toxicity.
A diagnostic dip-stick for measuring pseudocholinesterase activity has been assessed by 4 participants and compared with a standard spectrophotometric method. Duplicate dip-stick estimations (measured in kU/l) corresponded closely, and concurrence between participants was good. The dip-stick estimate of cholinesterase was consistently lower than the spectrophotometric value; the magnitude of this deviation depended on the absolute enzyme activity. With enzyme activities of up to 1 kU/l the dip-stick value was 1 unit lower. Between 1 and 4 kU/l the dip-stick estimate compared well with the spectrophotometric value. From 5 to 7 kU/l and beyond 7 kU/l the negative deviation recorded by the dip-stick increased to 2 units or more. Normal enzyme activity is 3 - 6 kU/l. Over the 1 - 4 kU/l range the method is most accurate, thus negative deviation below 1 kU/l or above 4 kU/l is generally diagnostically irrelevant. On the basis of cost, convenience, speed and accuracy this method will suffice in the absence of sophisticated assay facilities.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Assessment of the esophageal pressure technique for measuring dynamic lung compliance (Cdyn) showed that accurate results were obtained in only 5 of 15 studies of sick intubated infants, whereas they were obtained in 6 of 6 studies of convalescent nonintubated infants. In sick infants, inaccuracy was due to large variations in esophageal pressure change (delta Pes) at different esophageal depths and difficulties validating Pes using the occlusion test. Methods of assessing lung stiffness that depend on the measurement of esophageal pressure are unreliable and should not be used in sick intubated infants.
Respiratory system compliance (Crs) can be used to assess lung stiffness in sick, intubated infants, avoiding the use of an esophageal balloon. Crs was assessed in a group of 15 sick, intubated infants using the occlusion and inflation techniques. The occlusion technique gave satisfactory results in 13 infants. Apneic pauses following occlusion were obtained in infants up to 10 months of age. Satisfactory measurements of Crs were obtained in all 15 infants using the inflation technique, but difficulty was experienced in obtaining data over the tidal volume range in three of them. A close agreement was found between the two methods of measuring Crs in the ten infants in whom a direct comparison was possible.
Twenty-seven patients in a series of 52 patients with severe brain injury (Glasgow Coma Scale score less than or equal to 8) underwent insertion of intestinal feeding tubes at the bedside. The technique required endoscopy with externalization of gastric and intestinal ports through the abdominal wall. Feedings were begun through the intestinal tube with Vital HN within 4 hours of its insertion with simultaneous gastric decompression via the gastric tube. Tubes were placed 2.3 (range 0-5) days after injury. Full caloric intake (3020 kcal/24 h) was achieved by 6.8 (range 2-8) days after injury to 4.2 (range 2-8) days after placement of the feeding tube. Only 1 patient failed to tolerate feedings immediately after tube insertion. Technical inability to insert the tubes occurred in 3 patients and the intestinal tube migrated into the stomach in 2 patients; diarrhea occurred in only 1 patient. With this technique, it was possible to deliver an average daily intake of 1.2 g/kg of protein in 8-day balance periods beginning at the time of tube insertion. These data included 3- to 4-day periods in which feedings were steadily increased. In 16 patients in whom nitrogen balance was measured for 8-day balance periods, average nitrogen balance was -5.7 (range -11.3 to +3.5) g/24 h. The reduction in nitrogen loss by this technique appears equal to or superior to either gastric feeding or TPN. This technique provides the ability to enterally feed a high proportion of brain-injured patients (except those in barbiturate coma) very early after injury using a bedside procedure.(ABSTRACT TRUNCATED AT 250 WORDS)