Search PubMed⌕ Search

Biomedical subjects

H Markowitz

Publications and source records attributed to H Markowitz.

At least 37 records · Page 2Linked to original sources

Two new artifacts in automated coagulation testing.

Two artifacts were noted during the routine use of the Sherwood Lancer Coagulyzer. The first was that prothrombin times for 44 patients were greater than 90 sec on the Sherwood instrument, but were significantly shorter using reference methods. All 44 patients had subnormal fibrinogen values. Continuous optical density tracings during clotting performed for 11 patients demonstrated low slopes and amplitudes. For the three patients tested, the addition of fibrinogen corrected prothrombin times to values similar to those obtained on the Bio-Data instrument. Twenty-four of the patients subsequently died, 20 within three weeks of the observation of the artifact. The second artifact was that activated partial thromboplastin times for 12 patients were 9 sec on the Sherwood instrument, but were either normal or prolonged when using reference methods. Continuous tracings performed for nine patients demonstrated early optical density increases before clotting, which were responsible for the spurious values. Eleven of the 12 patients were hypoalbuminemic, and nine of the ten tested had elevated IgM levels. For seven patients, the artifact disappeared with in-vitro correction of hypoalbuminemia. Far from being weaknesses of the Coagulyzer, these artifacts may lead to the discovery of unsuspected, clinically significant laboratory information.

Blood Coagulation Tests↗

Antideoxyribonuclease B titers in psoriasis.

Psoriatic patients were examined for serologic evidence of streptococcal infections by using antideoxyribonuclease B (ADB), which has been shown to be a more sensitive screening tool than antistreptolysin O (ASO) for detecting such evidence in other clinical circumstances. Antistreptococcal antibody titers (ASO and ADB) of 71 patients with psoriasis vulgaris, 7 with guttate psoriasis, and 6 with erythrodermic psoriasis were compared with ASO and ADB antibody titers of 25 non-psoriatic dermatologic patients hospitalized at the same time and of an adult group that was used as a control for the test itself. Thirty-six of 71 patients with psoriasis vulgaris had elevated titers of ADB or ASO (41% vs. 15%). Compared with control values the ADB titers were significantly higher in patients with psoriasis vulgaris (P less than 0.02) and patients with guttate psoriasis (P less than 0.05). The ASO titers were significantly higher in patients with psoriasis vulgaris than in controls (P less than 0.04). Within the group with psoriasis vulgaris, ADB titers were significantly higher than ASO titers (P less than 0.01). Among patients with psoriasis vulgaris, histories of sudden flares of psoriasis and early recurrences of psoriasis after previous successful hospital treatment, family histories of psoriasis, and histories of potential streptococcal infections were more frequent in those with elevated antistreptococcal antibodies.

Antibodies, Bacterial↗

Quantitative method for estimating myoglobin in urine.

A simple, rapid, and quantitative immunochemical technique is described for quantitation of urinary myoglobin. The test is specific for myoglobin in the presence of hemoglobin or tissue constituents, can be completed within 1 h or less, and can detect 1 to 2 mg/liter. Normal urinary myoglobin concentrations are less than this.

Animals↗

Problems with beaded fluorescence pattern in FTA-ABS test.

The significance of false-positive FTA-ABS fluorescence in connective tissue diseases and other clinical conditions was evaluated by studying the serum from several groups of patients. In 12% of 67 patients without syphilis, serum with an antinuclear antibody (ANA) titer of 1:32 or greater gave low intensity FTA-ABS test fluorescence. In 20% of 150, patients (2.7% with a history of syphilis), serum with rheumatoid factor (RF) titers of 1:640 or greater demonstrated some reactivity. Only 1.3% of 75 donors of normal blood showed low-grade FTA-ABS fluorescence. In 385 patients with diagnostic problems, 2.1% of the serum demonstrated the beaded pattern. Patterns varied, depending on the treponemal antigen preparation and the duration of serum storage. Also, multiple specimens from the same patient produced different patterns. Furthermore, the beaded pattern could be demonstrated in patients with a history of syphilis, with other medical disorders, and in apparently normal persons.

Antibodies, Antinuclear↗

Do elephants ever forget?

Three adult female elephants (Elephas maximus) were tested on a light-dark discrimination problem with an 8-yr intertrial interval. The first subject took only 6 min to reach criterion and made only two errors, suggesting remarkable retention. The other two subjects were found to have visual anomalies that would have gone undetected without this research.

Animals↗

Immunosuppressive activity of concanavalin A.

Two strains of mice (C-57 B] and DBA) were given skin allografts from Swiss ICR/HA mice and were treated with varying doses of concanavalin A; the dosage ranged from only two injections of 25 micrograms during the experiment to daily doses of 1000 micrograms intraperitoneally. Immullosuppression was present at all dosages, the most prolonged and consistent effect being observed at 300 micrograms per day. Grafts survived for 14 to 21 days at this dosage compared to 4 to 9 days for controls.

Animals↗