Search PubMed⌕ Search

Biomedical subjects

H Imhof

Publications and source records attributed to H Imhof.

At least 127 records · Page 7Linked to original sources

[MRI in radiologically occult scaphoid fractures. Initial experiences with 1.0 Tesla (whole body-middle field equipment) versus 0.2 Tesla (dedicated low-field equipment)].

The study was performed to determine the diagnostic value of different MR systems and field strengths in patients with occult scaphoid and wrist fractures. Twelve patients with clinical suspicion of a scaphoid fracture but normal plain radiographs were examined by MRI. A dedicated 0.2-T unit (Esaote) and a 1.0-T unit (NT10, Philips) were used. Coronal T1W-SE, STIR, and T2*W-GE sequences were obtained with both systems. Images were evaluated for a bone marrow abnormality, a trabecular or cortical fracture line, and were compared to the 6-week follow-up radiographs. Seven wrist fractures were found at 0.2 T and 1.0 T, proven in the follow-up radiographs. A bone marrow abnormality was present in all seven fractures on both systems. Trabecular and cortical fracture lines were visualized at 0.2 T in four cases and at 1.0 T in seven cases. Low-field MR imaging at 0.2 T and mid-field MR imaging at 1.0 T seem to be equivalent in the diagnosis of a fracture in radiographically occult scaphoid and wrist fractures. In the visualization of fracture details, important for therapeutic and prognostic considerations, 1.0 T seems to be superior.

Adolescent↗

[Imaging of the middle ear. CT and MRI].

High-resolution computed tomography (HRCT) provides excellent contrast between osseous structures, air and soft tissue in conjunction with high spatial resolution. Therefore, thin-section HRCT with bone window setting is the method of choice for the examination of the middle ear structures. The indications are acute and chronic inflammatory changes, cholesteatoma and tumor, the "postoperative middle ear", and malformations. In most cases, HRCT enables differentiation between inflammatory changes, cholesteatoma, and tumor. The excellent depiction of subtle osseous details enables the identification of erosions of the ossicles or of the bony walls of the mastoid cells, of osseous defects of the tegmen, of the bony labyrinth, and of the tympanic course of the facial canal. In addition, HRCT enables excellent depiction of reconstructions of the ossicles or prosthesis of the ossicles. Although HRCT is the first method of choice, magnetic resonance imaging (MRI) may provide additional information and lead to a more accurate diagnosis in some cases. This is explained by the excellent soft tissue contrast provided by MRI. In addition, MRI offers the possibility of using various pulse sequences and the administration of i.v. contrast material. Therefore, MRI may allow the differentiation between inflammatory changes, cholesteatoma, and tumor in those cases in which accurate diagnosis cannot be made by HRCT. The differentiation between a meningocele or meningoencephalocele and other entities such as tumors or cholesteatoma can be established by MRI. Furthermore, MRI can accurately depict cases of labyrinthitis or of neuritis of the facial nerve or of intracranial disease caused by middle ear processes, while this is not always possible by HRCT. In summary, HRCT of the middle ear is the method of choice, but MRI may provide supplementary information in those cases in which accurate diagnosis cannot be established by HRCT.

Ear Diseases↗

Impact of spinal degenerative changes on the evaluation of bone mineral density with dual energy X-ray absorptiometry (DXA).

The purpose of this study is to evaluate degenerative factors in a postmenopausal patient group and differentiate the influence on bone mineral density (BMD) measurements by dual-energy X-ray absorptiometry (DXA). The patients and methods included an investigation of 144 postmenopausal women (mean 63.3 years) with PA-DXA of the spine. Degenerative factors (osteophytes, osteochondrosis, scoliosis, and vascular calcification) were evaluated from plain lumbar radiographs, their estimated probability was analyzed as a function of age, and their influence on BMD measured by PA-DXA was determined. The results of the study revealed osteophytes in 45.8%, vascular calcifications in 24.3%, scoliosis in 22.2%, osteochondrosis in 21.5%. The estimated probability for degenerative factors increased from 35 to 80% in the 55- to 70- year age group. Osteophytes and osteochondrosis were associated with up to a 14% increase in BMD values (P < 0.001). Vascular calcifications showed a positive trend, whereas scoliosis did not show a discernible influence.We concluded that degenerative factors, except for scoliosis, showed an influence on BMD as measured by DXA. Their prevalence increased rapidly between 55 and 70 years of age. Interpretation of PA-DXA spine data for subjects of or above this age range should be complemented by plain film radiographs.

Absorptiometry, Photon↗

Degenerative joint disease: cartilage or vascular disease?

The aetiology of degenerative joint disease is multifactorial, but one main cause is overloading (mechanical stress). While until recently it was well accepted that this represented primarily a disorder of cartilage with reactive subchondral changes, there is now some evidence that it might be primarily a subchondral problem with secondary changes in the articular cartilage. Early subchondral changes include redistribution of blood supply with marrow hypertension, oedema and probably micro-necrosis. These findings are very similar to those in avascular necrosis of bone and raise the question of a vascular aetiology. While these first reports need further proof, it seems clear that the articular cartilage and subchondral regions are one functional unit, in which the subchondral region is more stress sensitive. Recently described channels connecting these two regions strengthen this opinion. These new concepts are exciting and may make a major impact in the near future on the management of and research into degenerative joint disease.

Bone and Bones↗

Imaging of avascular necrosis of bone.

The etiology of avascular necrosis (AVN) is multifactorial. Independent of its etiology and localization it shows typical pathologies and radiological images. In the early stages localized subchondral edema is characteristic. In 50 % of all cases accompanying joint effusion may be found. Due to necrosis of the cells of bone marrow and bone fibrovascular, reactions with hyperemia can be delineated. These reactions allow us to visualize necrosis indirectly. The best imaging methods are MRI and, to a lesser extent, bone scintigraphy. In later stages calcification as well as new bone formation and microfractures are typically demonstrated and visualized best with plain X-rays and CT. Why reparations in many cases, particularly in the hip, are incomplete and may stop in any stage is unknown. Over years clinically complete silent AVNs are not an uncommon finding. Prognosis depends on the localization and size of the AVN. The number of repair mechanisms is best outlined with contrast-enhanced MRI and return of fatty marrow.

Bone and Bones↗

A study of the effects of patient anxiety, perceptions and equipment on motion artifacts in magnetic resonance imaging.

We investigated to see if motion artifacts (MA) occurring in magnetic resonance imaging (MRI) are related to prescan anxiety measures and test the feasibility of identifying patients at risk for the development of MA before scanning. Furthermore, to determine a possible influence of constructional differences between a 1.5 and a 0.5 tesla scanner on the frequency of MA. Two hundred and ninety-seven first time MRI patients were surveyed before and after imaging with anxiety and attitude questionnaires. Frequency and impact on diagnostic quality of MA were documented. 12.8% of all scans showed MA not related to normal body pulsations. In 6.4% the diagnostic quality was impaired. Constructional differences did not influence the frequency of MA. Also, anxiety as determined with the most common anxiety measuring instrument was not related to the development of MA. Concern about the technical apparatus identified 70.6% of all individuals developing MA. Patients at risk for the development of MA can be identified prior to scanning. It seems necessary to further develop reliable methods to detect them and to evaluate strategies to prevent MA.

Adult↗

[Determination of cartilage thickness in the ankle joint. an MRT (1.5)-anatomical comparative study].

PURPOSE: The aim of this study was to evaluate the accuracy of MRI in the measurement of cartilage thickness of the ankle joint in comparison to pathologic and histologic specimens. PATIENTS AND METHODS: The ankle joints of four fresh cadaver feet were imaged on a 1.5T MR-unit in the coronal plane. Standard T1-weighted spin echo (SE) and a T1-weighted 3D-GE (FLASH-3D) sequence with fat saturation were applied. Following MR imaging, the talus was explanted and cut parallel to the MR images for macroscopic evaluation and histologic specimens were prepared. MRI measurements of the cartilage thickness of the talus were carried out in two ways: without and with consideration of a transition zone of intermediate signal intensity between hyperintense cartilage and hypointense cortical bone. The data were compared with the anatomic specimens as the gold standard expressing the difference as a percentage value. On histologic specimens thickness of deep calcified cartilage layer was measured. RESULTS: Measurements without the transition zone showed a mean underestimation of talus cartilage thickness of 46.8% (41.3-52.1) for T1-SE and 47.5% (43.1-52.1) for fat saturated FLASH-3D images. Considering the transition zone the mean values were 25.0% (23.1-26.2) and 14.1% (6.7-21.5). The histologic specimens showed a three-fold increase of thickness of deep calcified cartilage layer. CONCLUSIONS: Measurements of the cartilage layer of the ankle joint on MR images are only accurate if the transition zone (calcified cartilage layer) is considered and the optimal pulse sequence (FLASH-3D-fat-sat) is applied.

Aged↗

[MRI of the regions of the inner ear and cerebellopontine angle using a 3D T2-weighted turbo spin-echo sequence. Comparison with conventional 2D T2-weighted turbo spin-echo sequences and T1-weighted spin-echo sequences].

PURPOSE: To assess the value of a three-dimensional (3D) T2-weighted turbo spin-echo sequence (3D T2-TSE) in comparison to conventional two-dimensional (2D) T2-weighted TSE and unenhanced and enhanced T1-weighted spin-echo sequences (SE) in imaging anatomic structures and pathologic changes of the inner ear and cerebellopontine angle. PATIENTS AND METHODS: The inner ear and cerebellopontine angle were investigated by MRI in three healthy volunteers and 18 patients performing a 2D T2-weighted turbo spin-echo sequence and a 3D T2-TSE in the axial plane. In the patient study, 2D T1-weighted SE sequences both before and after the i.v. injection of gadopentetate dimeglumine in both the axial and coronal plane were performed in addition. RESULTS: Only the 3D T2-TSE enabled an accurate imaging of the anatomic structures. In cases of pathology, the 3D T2-TSE provided additional information to the performed 2D sequences. The combination of the 3D T2-TSE with unenhanced and enhanced 2D T1-weighted SE enabled the most accurate diagnosis in cases of pathology. CONCLUSIONS: Accurate depiction of anatomic structures of the inner ear and cerebellopontine angle could be obtained by 3D T2-TSE only. The most accurate diagnosis in cases of pathology was provided by the combination of the 3D T2-TSE with unenhanced and enhanced 2D T1-weighted spin-echo sequences.

Adult↗

Influence of osteophytic size on bone mineral density measured by dual X-ray absorptiometry.

PURPOSE: To quantify the relationship between individual osteophytic size and measured bone mineral density (BMD) of the lumbar spine by dual x-ray absorptiometry (DXA). Further, to evaluate the possible consequences of this relationship for the management of DXA measurements in postmenopausal patients. MATERIAL AND METHODS: In 142 postmenopausal women (mean age 61.8 +/- 8.9 years), plain radiographs of the lumbar spine were evaluated and graded according to evidence and size of osteophytes. The BMD (g/cm2) and Z-score (deviation of BMD from an age-matched population, %) of each vertebral body was determined by DXA. The effects of the individual osteophytic size on BMD measurements were analyzed by using analysis of variance followed by a multiple test procedure. RESULTS: The presence of osteophytes resulted in a significant increase in BMD of L1 through L4. The increase in relation to an osteophytic size of about 10 mm was: in L1 5.7%, in L2 6.8%, in L3 4.4% and in L4 3.5%. Increases were significantly higher for an osteophytic size of 10-20 mm (L1 23.1%, L2 13.0%, L3 13.4%, and L4 16.3%) and of > 20 mm (L1 21.4%, L2 22.4%, L3 21.1% and L4 4.1%). CONCLUSION: Our results indicate a nonlinear increase of measured BMD with increasing osteophytic size. These effects should be considered in routine examination and patient management.

Absorptiometry, Photon↗

MR-guided joint puncture and real-time MR-assisted contrast media application.

OBJECTIVE: To develop, in MR arthrography of the shoulder joint, an MR-guided technique for localizing the needle puncture and confirming the intracapsular needle-tip position by visualization of the contrast media inflow. MATERIAL AND METHODS: Three unfixed human shoulder specimens were examined on a 1.0 T MR unit. On the basis of MR-compatible markers, the optimal entrance point for puncturing the joint was determined. The precise localization of the needle tip (MR-compatible 0.7-mm needle) in the shoulder joint was determined with rapid localizer GRE sequences in 2 orthogonal planes. To confirm the intracapsular position of the needle tip, diluted Gd-DTPA was applied via a long connecting tube and contrast medium inflow into the joint space was controlled on an LCD screen in real-time MR imaging (local-look technique). RESULTS: MR-compatible markers on the skin allowed the rapid determination of the optimal entrance point for needle puncture. An adequate localization of the intra-articular needle-tip position was possible in all specimens although significant artifacts were present on rapid localizer GRE sequences which resulted in an increase in the apparent width of the needle shaft. Real-time MR imaging of the contrast medium inflow was made possible by the local-look technique and LCD screen on the MR unit and this allowed confirmation of the intracapsular position. CONCLUSION: In MR arthrography of the shoulder, an MR-guided technique in conjunction with the LCD screen and real-time MR imaging would seem to be a practical alternative to conventional fluoroscopic guidance.

Artifacts↗

MR imaging of meniscal subluxation in the knee.

PURPOSE: The aim of this study was to establish diagnostic criteria for meniscal subluxation, and to determine whether there was any connection between meniscal subluxation and other common meniscal and knee-joint abnormalities. MATERIAL AND METHODS: The normal position of the meniscal body was assessed in 10 asymptomatic volunteers. MR signs of meniscal subluxation were evaluated retrospectively in 60 symptomatic patients with pain in the knee, impaired mobility, and/or joint swelling who had no clear diagnosis after the evaluation of case history, clinical examination, and radiography. The criterion for subluxation of the meniscus was defined as a distance of > or = 3 mm between the peripheral border of the meniscus and the edge of the tibial plateau. RESULTS: In the volunteers, the mean distance from the medial meniscus to the edge of the tibial plateau was 0.07 mm, and that from the lateral meniscus was 0 mm. In 55 symptomatic patients without meniscal subluxation, the mean distance from the meniscus to the edge of the tibial plateau was 0.27 mm. Five patients (8%) had evidence of meniscal subluxation, 4 in the medial meniscus and one in the lateral meniscus. The most commonly associated knee abnormality was joint effusion in 5 knees and osteoarthritis in 2 knees. CONCLUSION: Meniscal subluxation was not a rare finding with MR imaging in patients with painful knees. Meniscal subluxation was associated with other knee abnormalities such as joint effusion or osteoarthritis.

Adolescent↗

GRASE: ultra-fast turbo gradient spin-echo sequence. A new approach to fast MR imaging of the musculoskeletal system.

PURPOSE: Ultra-fast gradient and spin-echo (GRASE) imaging is a hybrid of turbo spin-echo (TSE) and echo-planar imaging (EPI). One scan consists of several spin echoes (SEs) (turbo factor, TF), each of which consists of a number of gradient echoes (EPI factor, EF). The aim of our study was to evaluate different combinations of TF and EF in GRASE imaging and to test its usefulness in musculoskeletal imaging. MATERIAL AND METHODS: On a 1.0 T MR unit, 11 GRASE sequences with different combinations of TF and EF (TR/TE 2150/120 ms) were evaluated in phantom studies with respect to signal-to-noise (S/N) ratio, nonuniformity of images, and geometrical distortion. From this study, the optimal GRASE-sequence was applied to 25 patients with different joint pathologies and compared to a T2-weighted TSE sequence (TR/TE 2855/130 ms). Lesion visualization, conspicuity, overall image quality, and artifacts were qualitatively analyzed by two observers independently of each other. RESULTS: With respect to S/N ratio, signal nonuniformity, and geometrical distortion, the GRASE sequence with TF/EF 7/3 (S/N 47; signal nonuniformity 11.7%; distortion 1 pixel) proved to be superior to the other GRASE sequences within a scanning time of less than 120 s. In a clinical study, the GRASE sequence proved superior to T2-weighted TSE (without fat suppression) in the visualization of bone-marrow and soft-tissue lesions (p < 0.001) and ligamentous injuries, although the image quality was inferior.

Artifacts↗

Diagnostic patterns for bone marrow oedema syndrome and avascular necrosis of the femoral head in dynamic bone scintigraphy.

This study used logistic regression analysis to assess qualitative patterns of tracer accumulation in an attempt to improve the diagnostic utility of bone scintigraphy for the detection of the bone marrow oedema syndrome (BMOS) and avascular necrosis (AVN) of the femoral head. Forty-eight symptomatic patients aged 44 +/- 9 years (mean +/- S.D.) with a final diagnosis of AVN (n = 29 hips), BMOS (n = 22), nine other hip disorders or a normal hip were examined with dynamic bone scintigraphy and qualitatively assessed for 11 scintigraphic signs in four phases by three blinded investigators. The accuracy for a correct diagnosis based on individual experience was 60-61% for the three observers, even if different signs were emphasized. A cold spot in the femoral head in both blood pool phases and the bone phase was seen only in 24% of AVN hips. Diffuse tracer accumulation in the femoral head, neck and the intertrochanteric region in the blood pool phases was seen only in 36% of BMOS hips. The arterial phase and the finding of a normal acetabulum in the bone phase had no diagnostic utility in this study. The presence of uptake increased the accuracy of differentiating AVN and BMOS from other disorders or normal hips to 88%. AVN could be differentiated from BMOS with an accuracy of 86% if the signs of the femoral head and inter-trochanteric uptake were combined into a diagnostic pattern. The scintigraphic pattern described increases the diagnostic accuracy of planar dynamic bone scintigraphy for BMOS and AVN.

Adult↗

Radiographically occult scaphoid fractures: value of MR imaging in detection.

PURPOSE: To evaluate the diagnostic value of magnetic resonance (MR) imaging in patients with clinical suspicion of scaphoid fractures and normal initial plain radiographs. MATERIALS AND METHODS: MR imaging was performed within 7 days after trauma in 42 patients with clinical suspicion of scaphoid fractures and normal plain radiographs. T1-weighted spin-echo, T2*-weighted gradient-echo, and short inversion time inversion-recovery (STIR) sequences were performed. MR images were evaluated independently by two radiologists. Six-week follow-up radiographs were used as a standard to diagnose fractures. RESULTS: MR imaging depicted occult fractures of the scaphoid bone in 14 patients (33%), the capitate bone in four (10%), the trapezium in one (2%), and the distal radius in two (5%). All wrist fractures were detected with a combination of STIR and T1-weighted spin-echo sequences. The sensitivity and specificity for detection of radiographically occult fractures of the wrist were 100% each for the first and 95% and 100%, respectively, for the second radiologist with an almost perfect interobserver agreement (K = 0.953). CONCLUSION: MR imaging has a high sensitivity for detection of fractures of the scaphoid bone and wrist not evident on plain radiographs and may enable early diagnosis and treatment.

Adolescent↗

Postoperative radiographic assessment of the Combi 40 cochlear implant.

OBJECTIVE: The aims of this study were to establish a plain radiographic technique for the assessment of the postoperative appearance, position, and insertion depth of the Combi 40 cochlear implant and to correlate the radiologic findings with surgical reports. SUBJECTS AND METHODS: In an experimental study, an electrode of the Combi 40 device was inserted into the cochlea of a cadaveric skull. Digital radiographs were obtained in a modified Chausse III projection, in which the skull was placed supine on the radiography table with the infraorbitomeatal line strictly perpendicular to the film cassette. The skull was then rotated 30 degrees away from the side to be examined, and the central X-ray beam was angled 15 degrees cephalad to the infraorbitomeatal line. On these radiographs, the point of cochleostomy was marked by a needle tip and was projected inferior to the vestibule and on a line drawn through the superior semicircular canal and the vestibule. The appearance and position of the electrode was evaluated. An electrode was defined as completely inserted if all electrode contacts projected medial to the line drawn through the superior semicircular canal and the vestibule. We also studied cochlear implant insertion of the Combi 40 device in 37 patients. Postoperative digital radiographs of these patients were obtained and analyzed for the criteria as defined in the cadaveric study. In addition, the insertion depth of the electrode and the angle of insertion were measured on the radiographs. This depth was correlated with depth of insertion as estimated at surgery. RESULTS: The cadaveric study showed that the completely inserted electrode was seen on radiographs as a nonoverlapping spiral within the cochlea. All electrode contacts projected medial to the line drawn through the superior semicircular canal and the vestibule. In all 37 patients, the electrode could be seen without overlapping. According to our criteria, a completely inserted electrode was seen in 32 patients. In these patients, the insertion depth ranged from 21 to 34 mm and the angle of insertion ranged from 350 degrees to 810 degrees. In two patients, we saw a completely inserted electrode with a bend. In three patients, an incompletely inserted electrode was seen. Excellent correlation existed between the radiologic and surgical results with regard to insertion depth (r = .92). CONCLUSION: Digital radiographs obtained in the modified Chausse III projection allow clear depiction of the electrode and avoid overlapping. Such radiographs enable a reliable and accurate assessment of the position and insertion depth of the electrode of this new cochlear implant. Such images can serve as a baseline for further radiographic examinations when extrusion or slippage of the electrode is clinically suspected.

Adult↗

High frequency of EEG and MRI brain abnormalities in panic disorder.

The frequency and quality of brain abnormalities in panic disorder (PD) were assessed with magnetic resonance imaging (MRI). The use of electroencephalography (EEG) to detect PD patients with a high probability of morphologic brain abnormalities was also explored. Consecutive PD patients (n = 120) were screened with routine EEG examinations and were divided into the following subgroups on the basis of their EEG findings: patients with non-epileptic EEG abnormalities (EEG-A group, n = 28), matched patients with normal EEG results (EEG-N group, n = 28) and matched healthy controls (n = 28). PD patients showed a higher than expected rate of non-epileptic EEG abnormalities (29.2%; 35 of 120). EEG screening was effective in identifying patients with a high probability of morphologic brain abnormalities. MRI abnormalities were found in 60.7% of the EEG-A patients, 17.9% of the EEG-N patients, and only 3.6% of the controls. A high frequency of septo-hippocampal abnormalities was found. Further research should focus on attempts to subtype PD on the basis of neuroanatomic and functional brain abnormalities.

Adult↗

[Differential diagnosis of diseases of the Achilles tendon. A clinico-sonographic concept].

Ultrasound of the Achilles tendon is a suitable means of differentiating various diseases of the tendon and the surrounding tissue. Different forms of degenerative disease (tendinitis, peritendinitis or bursitis, fibroosteitis, and Haglund's disease) can be discriminated from rheumatic and metabolic diseases. Congenital and developmental abnormalities can also be detected. Tendon degeneration mainly occurs in the ventral part of the medial third of the tendon ("critical zone"). Immature tissue in this area leads to temporary [correction of temorary] instability of the tendon with a high risk of rupture ("vulnerable phase"). With sonography, lesions of the Achilles tendon are visible early in the course of the disease.

Achilles Tendon↗