Search PubMed⌕ Search

Biomedical subjects

H Imhof

Publications and source records attributed to H Imhof.

At least 109 records · Page 6Linked to original sources

Osteometry of the mandible performed using dental MR imaging.

BACKGROUND AND PURPOSE: On cross-sectional and panoramic reformatted images from axial (dental) CT scans of the mandible it may be difficult to identify the inferior alveolar neurovascular bundle (IANB) in patients lacking a clear-cut bony delimitation of the mandibular canal. Dental MR images are comparable to dental CT scans, which directly show the IANB; however, measurements of length may not be reliable owing to susceptibility artifacts and field inhomogeneities in the oral cavity. Therefore, the accuracy of length measurements on dental MR images was compared with that on dental CT scans and direct osteometry. METHODS: Dental T1-weighted MR imaging using a high-resolution turbo gradient-echo sequence and dental CT were performed in six anatomic specimens. The axial scans were reformatted as panoramic and cross-sectional reconstructions on a workstation and characteristic cross sections were obtained from all mandibles. The longest axis in the bucco-lingual and apico-basal directions, the distances from the top of the mandibular canal to the top of the alveolar ridge and from the bottom of the mandibular canal to the base of the mandible, and the diameter of the bone cortex at the alveolar ridge were measured with direct osteometry on the cross sections and compared with measurements on corresponding MR and CT reformatted images. RESULTS: The correlation between direct osteometry and dental MR and CT was strong, except for the bone cortex diameter at the top of the alveolar ridge, where only a moderate correlation was found. Means of comparable length measurements were not significantly different among the three methods. CONCLUSION: The accuracy of length measurements in the jaw bones obtained using dental MR is comparable to that of dental CT and is not significantly different from direct osteometry. Thus, dental MR is a potential alternative to CT for dental imaging.

Alveolar Process↗

[Bone densitometry: comparative value and limitations of different techniques].

An early diagnosis of osteoporosis and an accurate estimation of treatment outcome are the focus of the radiological efforts. The most commonly applied methods for the evaluation of the peripheral and axial skeleton are dual x-ray absorptiometry, quantitative computed tomography, and quantitative ultrasound. Data of an individual are generally compared to an age-, sex-, and ethically-matched control population. The bone mass measurement predicts a patient's future risk of fracture and the presence of osteoporosis can be diagnosed even in the absence of prevalent fractures. Fracture risk increases approximately 1.5-2.5 times for every 1.0 standard deviation an individual's bone mass is below the mean peak bone mass of healthy young individuals (T-score). The choice of the appropriate measurement sites may vary depending on the specific circumstances of the patient. The choice of the appropriate technique in any given clinical circumstance should be based on the strength and limitations of the different techniques.

Absorptiometry, Photon↗

Experiences in intraoperative computer-aided navigation in ENT sinus surgery with the Aesculap navigation system.

Five patients with chronic sinus pathology and an indication for sinus surgery were selected. For intraoperative navigation, we used Surgical Planning and Orientation Computer Systems (SPOCS) Aesculap navigation software (ISG Technologies, Mississauga, Ontario, Canada) and surgical instruments fitted with light-emitting diodes. Navigation procedures are described in detail in the article. The system's precision was measured by pointing at anatomical landmarks. The accuracy was measured as the distance in millimeters between the bony structures of the computed tomographic (CT) scan on screen and the cross-hair of the pointer tip displayed on the screen. Another parameter of the system's accuracy was calculated by the system itself as the root mean square error in millimeters between the markers' position as registered and their position in the CT data set. Axial 3/3/1-mm spiral CT provided sufficient resolution, and data transfer via optical disk was practicable. Positioning of the navigation equipment required some experience, and the registration of the patient's head position also needed attention, as the markers have to be pointed at precisely. During the operation, the position of the head-tracking system on the patient's head must remain unchanged to ensure a correct navigation display. The main advantage of the computed navigation system was the constant orientation provided during the sinus surgical procedure. Borders and critical anatomical structures could be identified in the corresponding CT data set, thus enabling the surgeon to decide on subsequent procedures. Use of the navigation system was found to increase the operation time by about 1 h, resulting in additional time under anesthesia. We found the SPOCS Aesculap computed navigation system to be an established technical aid, ready for use in ENT sinus surgery. In the cases reported here, a precision between 1 and 3 mm was obtained.

Humans↗

[Ewing sarcoma. Diagnostic imaging].

Ewing's sarcoma is a highly malignant neoplasm of the bone whose origin is still uncertain. A strong relationship exists between Ewing's sarcoma and tumors of neural origin (Ewing family of tumors). Ewing's sarcoma must be distinguished from other round-cell tumors like lymphoma and neuroblastoma and also must be differentiated from osteogenic sarcomas. On plain radiographs, Ewing's sarcoma appears as a lytic or mixed lytic-sclerotic, rarely as predominantly sclerotic lesion with margins Lodwick grade III. It is located primarily in the diaphyseal and metadiaphyseal regions of the long bones of the lower extremities. A large soft tissue tumor is usually present. Magnetic resonance imaging is the imaging modality of choice to evaluate the extent of the primary lesion, to monitor the response to neoadjuvant chemotherapy and to follow up non-resected Ewing's sarcomas. Bone scintigraphy is necessary to detect skeletal metastasis, and 201thallium scanning has been shown to be sensitive in the monitoring of treatment response. Today, computed tomography is not longer used to image the tumor site; however, spiral CT of the lungs plays a central role as a staging and follow-up tool.

Bone Neoplasms↗

[Pitfalls in MRI diagnosis of primary malignant bone tumors].

MRI has gained an undisputed place in the evaluation of malignant bone tumors, not only for verifying results of conventional radiographs and clarifying differential diagnoses; it has also become increasingly important for the assessment of the malignant/benign nature of the tumor, its growth rate, definition of adequate sites for biopsy, local preoperative staging, and evaluation of the response to chemotherapy. However, several pitfalls have to be observed regarding choice of technical parameters (coils, sequences, imaging planes), tissue differentiation, and tumor staging. When staging malignant tumors, critical aspects which have to be observed are tumor extension, integrity of the cortical bone, soft tissue components, infiltration of a joint or neurovascular bundle. The use of contrast agents provides important additional information but can also give rise to misinterpretations. Thus, all features of a tumor have to be observed in order to establish a final diagnosis. Particular difficulties can occur with the interpretation of MR images of osteomyelitis, osteoid osteoma, stress and insufficiency fractures, bone infarcts, myositis ossificans, hemangiomas, and aneurysmal bone cysts.

Bone Cysts↗

[Spiral CT and conventional CT in the preoperative imaging of intraocular metal foreign bodies].

PURPOSE: To compare the effectiveness of spiral CT versus conventional CT in the preoperative assessment of metallic intraocular foreign bodies. METHODS: Eighteen patients with penetrating eye injuries and suspected metallic intraocular foreign bodies were assigned to undergo either spiral CT or conventional CT in the axial plane. The spiral and the conventional CT data were transferred to a workstation, and reconstructions in the coronal and sagittal planes were performed. Additional direct coronal scanning was performed only when necessary for preoperative assessment. The quality of the axial as well as the reconstructed coronal and sagittal images was assessed for each imaging modality. The size of the foreign bodies was measured and compared to the actual diameter. Total examination time and radiation dose delivered to the lens were measured for each imaging modality. RESULTS: All foreign bodies were detected by each scanning modality on the axial and on the reconstructed planes. The quality of the axial images was similar for spiral and conventional CT. The spiral technique provided high-quality reconstructed images which allowed accurate localization of the foreign bodies in all cases. Reconstructions by conventional technique were inadequate for preoperative assessment. The examination time for the total orbital volume was 18 s for spiral CT and 52 s for conventional CT. Radiation dose delivered to the lens was 35 mGy for spiral CT and 56 mGy for conventional CT axial scanning. CONCLUSION: Spiral CT multiplanar imaging offers several significant advantages for the preoperative assessment of metallic intraocular foreign bodies compared to the conventional CT technique in clinical practice, including short examination time, minimized motion artifacts, reduced radiation exposure, and accurate localization.

Adolescent↗

Multiplanar imaging in the preoperative assessment of metallic intraocular foreign bodies. Helical computed tomography versus conventional computed tomography.

OBJECTIVE: This study aimed to compare the effectiveness of helical computed tomography (CT) versus conventional CT in the preoperative assessment of metallic intraocular foreign bodies on axial, coronal, and multiplanar reconstruction images in clinical routine. DESIGN: Prospective comparative trial, alternate assignment of consecutive patients. PARTICIPANTS: Eighteen patients with penetrating eye injuries and suspected metallic intraocular foreign bodies were studied. INTERVENTION: Alternate patients were assigned to undergo either helical CT or conventional CT in the axial plane. Both the helical and the conventional data were transferred to a workstation, and reconstructions in the coronal and sagittal planes were performed. Additional direct coronal scanning was performed only when necessary for preoperative assessment. MAIN OUTCOME MEASURES: The quality of the directly obtained axial and coronal, as well as the reconstructed coronal and sagittal images, was assessed for each, imaging method based on the ability to detect and accurately localize foreign bodies. The size of the foreign bodies was measured and compared to the actual diameter. Total examination time and radiation dose delivered to the lens were measured for each imaging method. RESULTS: All foreign bodies were detected by each scanning method on the axial, the coronal, and on the reconstructed planes. The quality of the axial images was similar for helical and conventional CT. The helical technique provided high-quality reconstructed images comparable in quality to the directly obtained coronal planes in conventional CT. Reconstructions by conventional technique were not useful for preoperative assessment. The examination time for the total orbital volume was 18 seconds for helical CT examinations and 52 seconds for conventional CT examinations. Radiation dose delivered to the lens for the complete examination was 35 mGy for helical CT axial scanning, 56 mGy for conventional CT axial scanning, and 63 mGy for conventional CT coronal scanning. CONCLUSIONS: Helical CT multiplanar imaging offers several significant advantages for the preoperative assessment of metallic intraocular foreign bodies compared to the conventional CT technique in clinical practice, including short examination time, reduced motion artifacts, reduced radiation exposure, and the ability to obtain diagnostically useful coronal and sagittal reconstruction images without the need for additional scanning.

Adolescent↗

Contrast-enhanced computed tomography of freely transplanted jejunal patches after surgery in the oral cavity and oropharynx.

Thirty-two patients with jejunal patches in the oral cavity and oropharynx were examined with contrast-enhanced computed tomography (CT). The morphology of the intestinal wall, the mesenteric fatty tissue, mesenteric lymph nodes and the region of the anastomosis were evaluated and correlated with clinical findings. The size and number of mesenterial lymph nodes, which were found in 16 cases, did not correlate with tumour recurrence. The benign alterations of the intestinal wall ranged from flat surfaces with no enhancement to significant enhancement with persisting folds. In cases with persisting intestinal folds, separation of tumour recurrence was achieved by identification of a typical double-layer configuration of the enhancing mucosa, and the restriction of alterations to the intestinal wall compartment. Tumour recurrences occurred at patch margins and were reliably distinguished from normal patches. For differentiation of findings, an exact localization of jejunum-patch compartments and margins with contrast-enhanced CT was, therefore, necessary.

Adult↗

Localization of the mandibular neurovascular bundle using dental magnetic resonance imaging.

OBJECTIVE: To assess the reliability of a commercially available 3D-MPR MRI program for the jaws for imaging the mandibular neurovascular bundle. METHODS: A gradient echo sequence (TR: 49 ms/TE: 6.3 ms/flip angle: 25 degrees/excitations: 3) with a spectral fat suppression pre-impulse and a voxel size of 0.9 x 0.9 x 0.8 mm was designed. Cross-sectional and panoramic reconstruction of the whole mandible were performed from the axial scans using Easy Vision (Philips, Best, The Netherlands) software package. The ability of differentiate the mandibular neurovascular bundle was assessed in 11 patients. RESULTS: The mandibular neurovascular bundle was clearly visualized in all cases. CONCLUSION: Dental MRI is a possible alternative to plain films or CT for patients requiring surgery near the mandibular canal.

Anatomy, Cross-Sectional↗

[Dental magnetic resonance tomography (dental MRI) as a method for imaging maxillo-mandibular tooth retention structures].

PURPOSE: To establish a new method for dental imaging using magnetic resonance tomography named Dental-MRT and to demonstrate its usefulness in diagnosing dentogen pathologies of the mandible and maxilla. METHODS: Seven healthy volunteers, three patients with pulpitis, two patients with dentigerous cysts, two patients after tooth transplantation, and three patients with atrophic mandibles have been evaluated. Optimized axial T1- and T2-weighted gradient echo and spin echo sequences in 2D and 3D technique have been established to perform studies of the jaws. The acquired images were reconstructed with a standard dental software package on a work-station as panorama and cross-sectional views of the mandible or maxilla. RESULTS: The entire maxillo-mandibular bone, teeth, dental pulp, and the content of the mandibular canal were well depicted. Patients with pulpitis demonstrate bone marrow edema in the periapical region. Dentigerous cysts and their relation to the surrounding structures are clearly shown. After contrast media administration marked enhancement of the dental pulp can be demonstrated. CONCLUSION: Dental-MRT promises to provide a new tool for visualization and detection of dental diseases.

Adolescent↗

MR imaging in shoulder trauma. Value of STIR images.

PURPOSE: To determine the adequacy of MR standard protocols by analyzing conventional T1- and T2-weighted SE sequences, and to evaluate the usefulness of additional fat-suppressed (STIR) images in shoulder trauma. MATERIAL AND METHODS: Paracoronal T1-weighted, T2-weighted, SE, and STIR images were obtained on a 0.5 T superconductive system in 25 patients with shoulder trauma. In a separate evaluation of T1/T2 images and a combined evaluation of T1/T2 SE- and STIR images, we compared the number of patients with evidence of Hill-Sachs lesions, bone bruises, and/or rotator-cuff lesions. RESULTS: Compared to the combined evaluation of T1/T2 and STIR images, the separate evaluation of T1/T2 SE images revealed identical results for rotator-cuff lesions and Hill-Sachs lesions, but different results for the bone bruises in the area of the major tubercle. CONCLUSION: Occult fractures of the major tubercle, indicated by areas of bone bruising, might be missed with MR using conventional SE images. We recommend the use of additional paracoronal fat-suppressed sequences in patients with clinically suspected lesions and equivocal findings on plain radiographs and on standard SE sequences.

Adult↗

Low-field magnetic resonance imaging (0.2 T) of tendons with sonographic and histologic correlation. Cadaveric study.

RATIONALE AND OBJECTIVES: The authors evaluate the role of low-field strength magnetic resonance imaging (MRI) compared with sonography in the evaluation of degenerative changes of tendons, with histologic correlation, based on investigations of horse cadavers. METHODS: Low-field MRI and sonography was performed in 42 hours specimens for the evaluation of tendons and ligaments. Magnetic resonance imaging included sagittal and axial T1-weighted, T2-weighted, and gradient echo images. Sonography and MR images were evaluated for degenerative changes or tears and the findings were correlated with the histologic results. RESULTS: Using histologic findings as a gold standard, the accuracy for the sonographic evaluation was 65.9%, sensitivity was 16.7%, and specificity was 100%. The corresponding data for low-field MR imaging were 70.5% accuracy, 44.4% sensitivity, and 88.5% specificity. CONCLUSIONS: Low-field MRI investigation allows more accurate staging of tendinous changes than sonography. It is more reproducible and potentially includes the advantages of the combined evaluation of bones, ligaments, and soft tissue.

Animals↗

MR imaging of the inner ear and cerebellopontine angle: comparison of three-dimensional and two-dimensional sequences.

OBJECTIVE: The aim of the study was to compare the ability of three-dimensional (3D) T2-weighted turbo spin-echo and gadolinium-enhanced 3D T1-weighted gradient-echo sequences with two-dimensional (2D) T2-weighted turbo spin-echo and gadolinium-enhanced T1-weighted spin-echo sequences to reveal anatomic and pathologic structures of the inner ear and cerebellopontine angle. SUBJECTS AND METHODS: Thirty-one patients underwent axial 2D T2-weighted turbo spin-echo and 3D T2-weighted turbo spin-echo MR imaging, axial and coronal 2D T1-weighted spin-echo MR imaging before and after i.v. injection of gadopentetate dimeglumine, and gadolinium-enhanced axial 3D T1-weighted gradient-echo MR imaging. The visualization of anatomic and pathologic structures on the different sequences was evaluated. Statistical analysis was performed from the data obtained from the visual evaluation of the anatomic structures on the different sequences. Signal-to-noise and contrast-to-noise ratios were calculated for the gadolinium-enhanced 3D T1-weighted gradient-echo and 2D T1-weighted spin-echo sequences, and statistical evaluation was performed. RESULTS: The 3D sequences enabled excellent visualization of 94% of all evaluated anatomic structures, and the 2D sequences enabled excellent visualization in only 3% of these structures. Pathologic structures were revealed in all cases by one or both of the 3D sequences. Diagnosis in all patients could be made by using the combination of the 3D T2-weighted turbo spin-echo and the gadolinium-enhanced 3D T1-weighted gradient-echo sequences. However, the 2D sequences failed to show pathologic structures in three patients. We found a significant statistical difference for the visualization of anatomic structures with the 3D and 2D sequences (p < .0001) and no significant statistical difference for the signal-to-noise and contrast-to-noise ratios with the 3D T1-weighted gradient-echo and 2D T1-weighted spin-echo sequences. CONCLUSION: The 3D sequences revealed anatomic structures significantly better than did the 2D sequences and showed pathologic structures considerably more often than did the 2D sequences in all patients. MR imaging of the inner ear and cerebellopontine angle performed with 3D T2-weighted turbo spin-echo and gadolinium-enhanced 3D T1-weighted gradient-echo sequences provided the most accurate imaging leading to diagnosis in cases of abnormality.

Adult↗

[MRI on low-field tomography systems (0.2 Tesla). A quantitative comparison with equipment of medium-field strength (1.0 Tesla)].

AIM OF THE STUDY: Using phantom studies, a dedicated low-field MR system with 0.2 T and a whole-body MR-scanner with 1.0 T were compared. METHODS: A spin-echo sequence was performed on the 0.2-T MR unit using the knee coil and on the 1.0-T MR unit with the head coil. In a water-filled phantom, signal-to-noise ratios (SNR) were calculated and contrast measurements on gels with well-defined relaxation times were obtained and compared to nominal relaxation times. Measurements of T1 and T2 relaxation times on the low-field system were compared to the 1.0-T unit. As a parameter for geometrical image quality, magnetic field distortions were calculated. In theory, influence of field strength and and receiver bandwidth on the minimal echo time and on chemical shift artifacts were calculated. RESULTS: The SNR was 63.2 on the 0.2-T and 179.6 on the 1.0-T MR unit (difference factor 3, against a theoretical difference of 5-16). Relaxation times on the low-field system were significantly (around 40-50%) lower. Measurements of contrast were similar on both systems. On the low-field system geometrical distortions of several pixels were recorded. The minimal echo time on the low-field system was 21.3 ms with the low receiver bandwidth and 4.3 ms on the 1.0-T MR unit. The amount of chemical shift artefacts was the same on both systems. DISCUSSION: On low-field MR systems SNR is markedly improved by small read-out gradients and a low receiver bandwidth (factor 3 vs 5-16 in comparison with the 1.0-T MR unit). However, an optimal homogeneous magnetic field is required, since inhomogeneities may create severe geometrical distortion.

Artifacts↗

[Comparison of diagnostic sensitivity in meniscus diagnosis of MRI examinations with a 0.2 T low-field and a 1.5 T high field system].

The aim of this study was to evaluate the reliability of a low field strength MRI unit (0.2 T; Esaote, Biomedica) and a high field strength MRI unit (1.5 T; Siemens) in detecting meniscal lesions. Twenty patients were investigated on a 0.2-T low-field MRI unit and a 1.5-T high-field MRI unit for meniscal lesions. Evaluation was performed of four meniscal compartments (anterior and posterior medial and lateral meniscus), for a total of 80 observations. The reliability of diagnosis was ranked qualitatively on a three-point scale. Investigations of the high-field MRI unit revealed a meniscal tear in 6 patients and ruled out a tear in 14 patients. Evaluation of individual meniscal compartments revealed diagnosis with high confidence in 58 observations and with moderate confidence in 22 observations. Investigations of the low-field MRI unit revealed a meniscal tear in 5 patients and ruled out tears in 15 patients. Evaluation of individual meniscal compartments revealed diagnosis with high confidence in 39 observations, with moderate confidence in 38 observations, and with low confidence in 3 observations. The diagnosis in high- and low-field images was identical in 98.7% of cases; in one patient observations from the high-field unit changed the therapeutic management. Diagnostic reliability was significantly higher with high-field strength MR imaging. Low field strength MR imaging shows comparatively high diagnostic accuracy for meniscal lesions compared to high field strength imaging; however, we demonstrated a significantly higher confidence in diagnosis with high-field MR imaging.

Adult↗

[MRI diagnosis of lesions of the anterior cruciate ligament--comparison of 1.0 Tesla and 0.2 Tesla. Initial results].

The purpose of our study was to compare the diagnostic performance of a 0.2-T MRI unit and a 1.0-T MRI unit in the evaluation of the anterior cruciate ligament in patients with clinically suspected lesions of this ligament. Twenty four patients with clinically suspected lesions of the anterior cruciate ligament underwent MRI of the knee on both 0.2-T and 1.0-T MRI units. Three independent observers evaluated the examinations for primary and secondary signs of a tear of the anterior cruciate ligament. Frequency of these signs was determined for both modalities, and observer agreement was assessed using the kappa statistic. Sixteen of 24 patients had signs of tears of the anterior cruciate ligament on the 1.0-T unit; the 0.2-T unit detected primary signs in 15/16 (93%) patients and secondary signs in 7/12 (43%) patients. In 8 patients the 1.0 T unit showed neither primary nor secondary signs for tears of the anterior cruciate ligament; in these patients the 0.2-T unit detected primary signs in 1/8 cases (12%), and secondary signs in 3/8 cases (37%). Observer agreement was very good for the 1.0-T unit and fair for the 0.2-T unit. There is no substantial difference between 1.0-T units and 0.2-T MRI units in the visualisation of primary signs of tears of the anterior cruciate ligament. In the visualisation of secondary signs, 1.0-T units are superior to 0.2-T units, and there is a surprisingly high rate of false-positive results with the 0.2-T unit. As to the reproducibility of the results, the 1.0-T unit is far superior to the 0.2-T unit.

Adult↗