Search PubMed⌕ Search

Biomedical subjects

Georges Guiochon

Publications and source records attributed to Georges Guiochon.

At least 55 records · Page 3Linked to original sources

Effect of the endcapping of reversed-phase high-performance liquid chromatography adsorbents on the adsorption isotherm.

The retention mechanisms of n-propylbenzoate, 4-t ert-butylphenol, and caffeine on the endcapped Symmetry-C(18) and the non-endcapped Resolve-C(18) are compared. The adsorption isotherms were measured by frontal analysis (FA), using as the mobile phase mixtures of methanol or acetonitrile and water of various compositions. The isotherm data were modeled and the adsorption energy distributions calculated. The surface heterogeneity increases faster with decreasing methanol concentration on the non-endcapped than on the endcapped adsorbent. For instance, for methanol concentrations exceeding 30% (v/v), the adsorption of caffeine is accounted for by assuming three and two different types of adsorption sites on Resolve-C(18) and Symmetry-C(18), respectively. This is explained by the effect of the mobile phase composition on the structure of the C(18)-bonded layer. The bare surface of bonded silica appears more accessible to solute molecules at high water contents in the mobile phase. On the other hand, replacing methanol by a stronger organic modifier like acetonitrile dampens the differences between non-endcapped and endcapped stationary phase and decreases the degree of surface heterogeneity of the adsorbent. For instance, at acetonitrile concentrations exceeding 20%, the surface appears nearly homogeneous for the adsorption of caffeine.

Acetonitriles↗

Thermodynamic functions and intra-particle mass transfer kinetics of structural analogues of a template on molecularly imprinted polymers in liquid chromatography.

The parameters of the thermodynamics and mass transfer kinetics of the structural analogues (L-enantiomers) of the template were measured on an Fmoc-L-tryptophan (Fmoc-L-Trp) imprinted polymer, at different temperatures. The equilibrium isotherm data and the overloaded band profiles of these compounds were measured at temperatures of 298, 313, 323, and 333 K. The isotherm data were modeled. The thermodynamic functions of the different adsorption sites were derived from the isotherm parameters, using van't Hoff plots. The mass transfer parameters were derived by comparing the experimental peak profiles and profiles calculated using the lumped pore diffusion (POR) model for chromatography. These data show that (1) the strength between the substrate molecules and the MIP increases with increasing number of functional groups on the substrates; (2) enthalpy is the driving force for the affinity of the substrates for the MIP; (3) surface diffusion is the dominant mass transfer mechanism of the substrates through the porous MIP. For those substrate molecules that have the same stereochemistry as the template, the energetic surface heterogeneity needs to be incorporated into the surface diffusion coefficients. Heterogeneous surface diffusivities decrease with increasing affinity of the substrates for the MIP.

Adsorption↗

Systematic errors in the measurement of adsorption isotherms by frontal analysis Impact of the choice of column hold-up volume, range and density of the data points.

Besides the accuracy and the precision of the measurements of the data points, several important parameters affect the accuracy of the adsorption isotherms that are derived from the data acquired by frontal analysis (FA). The influence of these parameters is discussed. First, the effects of the width of the concentration range within which the adsorption data are measured and of the distribution of the data points in this range are investigated. Systematic elimination of parts of the data points before the calculation of the nonlinear regression of the data to the model illustrates the importance of the numbers of data points (1) within the linear range and (2) at high concentrations. The influence of the inaccuracy of the estimate of the column hold-up volume on each adsorption data point, on the selection of the isotherm model, and on the best estimates of the adsorption isotherm parameters is also stressed. Depending on the method used to measure it, the hold-up time can vary by more than 10%. The high concentration part of the adsorption isotherm is particularly sensitive to errors made on t(0,exp) and as a result, when the isotherm follows bi-Langmuir isotherm behavior, the equilibrium constant of the low-energy sites may change by a factor 2. This study shows that the agreement between calculated and experimental overloaded band profiles is a necessary condition to validate the choice of an adsorption model and the calculation of its numerical parameters but that this condition is not sufficient.

Adsorption↗

The adsorption mechanism of nortryptiline on C18-bonded Discovery.

The adsorption isotherms of an ionizable compound, nortriptyline, were accurately measured by frontal analysis (FA) on a C(18)-Discovery column, first without buffer (in an aqueous solution of acetonitrile at 15%, v/v of ACN), then with a buffer (in 28%, v/v ACN solution). The buffers were aqueous solutions containing 20 mM of formic acid or a phosphate buffer at pH 2.70. The linear range of the isotherm could not be reached with the non-buffered mobile phase using a dynamic range larger than 40,000 (from 1.2 x 10(-3) g/L to 50 g/L). With a 20 mM buffer in the liquid phase, the isotherm is linear for concentrations of nortriptyline inferior to 10(-3) g/L (or 3 micromol/L). The adsorption energy distribution (AED) was calculated to determine the heterogeneity of the adsorption process. AED and FA were consistent and lead to a trimodal distribution. A tri-Moreau and a tri-Langmuir isotherm models accounted the best for the adsorption of nortriptyline without and with buffer, respectively. The nature of the buffer affects significantly the middle-energy sites while the properties of the lowest and highest of the three types of energy sites are almost unchanged. The desorption profiles of nortriptyline show some anomalies in relation with the formation of a complex multilayer adsorbed phase of acetonitrile whose excess isotherm was measured by the minor disturbance method. The C(18)-Discovery column has about the same total saturation capacity, around 200 g of nortriptyline per liter of adsorbent (or 116 mg/g), with or without buffer. About 98-99% of the available surface consists in low energy sites. The coexistence of these different types of sites on the surface solves the McCalley's enigma, that the column efficiency begins to drop rapidly when the analyte concentration reaches values that are almost one hundred times lower than those that could be predicted from the isotherm data acquired under the same experimental conditions. Due to the presence of some relatively rare high energy sites, the largest part of the saturation capacity is not practically useful.

Acetonitriles↗

Stress distribution and dimensional changes in chromatographic columns.

High pressures, in the kilobar range, are now used in liquid chromatography. Basic equations from mechanics are applied to investigate the stress state in several idealized chromatography tubes, and these stresses are evaluated with respect to the maximum allowable stresses predicted by several methods used in pressure vessel design. An analytical solution is developed for the dimensional changes of idealized tubes subjected to internal pressure, and the analytical solutions used to verify the results from a numerical approximation. Numerical approximations are then used to explore the effects of the end restraint provided by the end frits. Conclusions are derived regarding the requirements for a safe operation of these high pressure chromatography tubes.

Chromatography↗

Viscous fingering induced flow instability in multidimensional liquid chromatography.

Viscous fingering is a flow instability phenomenon that results in the destabilisation of the interface between two fluids of differing viscosities. The destabilised interface results in a complex mixing of the two fluids in a pattern that resembles fingers. The conditions that enhance this type of flow instability can be found in coupled chromatographic separation systems, even when the solvents used in each of the separation stages have seemingly similar chemical and physical properties (other than viscosity). For example, the viscosities of acetonitrile and methanol are sufficiently different that instability at the interface between these two solvents can be established and viscous fingering results. In coupled chromatographic systems, the volume of solvent transported from one separation dimension to the second often exceeds the injection volume by two or more orders of magnitude. As a consequence, viscous fingering may occur, when otherwise following the injection of normal analytical size injection plugs viscous fingering would not occur. The findings in this study illustrate the onset of viscous fingering in emulated coupled chromatographic systems and show the importance of correct solvent selection for optimum separation performance.

Acetonitriles↗

Adsorption mechanism in RPLC. Effect of the nature of the organic modifier.

The adsorption isotherms of phenol and caffeine were acquired by frontal analysis on two different adsorbents, Kromasil-C18 and Discovery-C18, with two different mobile phases, aqueous solutions of methanol (MeOH/H2O = 40/60 and 30/70, v/v) and aqueous solutions of acetonitrile (MeCN/H2O = 30/70 and 20/80, v/v). The adsorption isotherms are always strictly convex upward in methanol/water solutions. The calculations of the adsorption energy distribution confirm that the adsorption data for phenol are best modeled with the bi-Langmuir and the tri-Langmuir isotherm models for Kromasil-C18 and Discovery-C18, respectively. Because its molecule is larger and excluded from the deepest sites buried in the bonded layer, the adsorption data of caffeine follow bi-Langmuir isotherm model behavior on both adsorbents. In contrast, with acetonitrile/water solutions, the adsorption data of both phenol and caffeine deviate far less from linear behavior. They were best modeled by the sum of a Langmuir and a BET isotherm models. The Langmuir term represents the adsorption of the analyte on the high-energy sites located within the C18 layers and the BET term its adsorption on the low-energy sites and its accumulation in an adsorbed multilayer system of acetonitrile on the bonded alkyl chains. The formation of a complex adsorbed phase containing up to four layers of acetonitrile (with a thickness of 3.4 A each) was confirmed by the excess adsorption isotherm data measured for acetonitrile on Discovery-C18. A simple interpretation of this change in the isotherm curvature at high concentrations when methanol is replaced with acetonitrile as the organic modifier is proposed, based on the structure of the interface between the C18 chains and the bulk mobile phase. This new model accounts for all the experimental observations.

Journal Article↗

Csaba Horváth and preparative liquid chromatography.

Few chromatographers have been interested in furthering preparative liquid chromatography. The pioneers, Tswett, Kuhn and Lederer, A.J.P. Martin, Tiselius, isolated fractions but as an intermediate step in the analysis of their samples. The progress in electronics and sensors, and in their miniaturization has lead to the paradoxical situation that the analysts never see the transient pure fractions that their detector quantitates. Yet, over the last 25 years, preparative liquid chromatography has become an important industrial process for the separation, the extraction, and/or the purification of many pharmaceuticals or pharmaceutical intermediates, including pure enantiomers, purified peptides and proteins, compounds that are manufactured at the relatively large industrial scale of a few kilograms to several hundred tons per year. This development that has strongly affected the modem pharmaceutical industry is mainly due to the pioneering work of Csaba Horváth. His work in preparative HPLC was critical at both the practical and the theoretical levels. He was the first scientist in modem times to pay serious attention to the relationships between the curvature of the equilibrium isotherms, the competitive nature of nonlinear isotherms, and the chromatographic band profiles of complex mixtures. The thermodynamics of multi-component phase equilibria and mass transfer kinetics in chromatography attracted his interest and were the focus of ground-breaking contributions. He investigated displacement chromatography, an old method invented by Tiselius that Csaba was first to implement in HPLC. This choice was explained by the essential characteristic of displacement chromatography, in that it delivers fractions that can be far more concentrated than the feed. Remarkably, once the basics of nonlinear chromatography had been mastered in his group, most of the applications that were studied by his coworkers dealt with peptides of various sizes and with proteins. Thus, all the applications of preparative HPLC in the biotechnologies derive directly from Csaba's work. Although displacement did not pan out as a general method, the reasons are related more to practical constraints of the production of pharmaceuticals and to the long period of cheap energy that might be ending now. This report reviews Csaba's work in nonlinear chromatography.

Chromatography, High Pressure Liquid↗

Extrathermodynamic study of surface diffusion in reversed-phase liquid chromatography with silica gels bonded with alkyl ligands of different chain lengths.

Surface diffusion on adsorbents made of silica gels bonded to C1, C4, C8, and C18 alkyl ligands was studied in reversed-phase liquid chromatography (RPLC) from the viewpoints of two extrathermodynamic relationships: enthalpy-entropy compensation (EEC) and linear free-energy relationship (LFER). First, the values of the surface diffusion coefficient (D(s)), normalized by the density of the alkyl ligands, were analyzed with the modified Arrhenius equation, following the four approaches proposed in earlier research. This showed that an actual EEC resulting from substantial physicochemical effects occurs for surface diffusion and suggested a mechanistic similarity of molecular migration by surface diffusion, irrespective of the alkyl chain length. Second, a new model based on EEC was derived to explain the LFER between the logarithms of D(s) measured under different RPLC conditions. This showed that the changes of free energy, enthalpy, and entropy of surface diffusion are linearly correlated with the carbon number in the alkyl ligands of the bonded phases and that the contribution of the C18 ligand to the changes of the thermodynamic parameters corresponds to that of the C10 ligand. The new LFER model correlates the slope and intercept of the LFER to the compensation temperatures derived from the EEC analyses and to several parameters characterizing the molecular contributions to the changes in enthalpy and entropy. Finally, the new model was used to estimate D(s) under various RPLC conditions. The values of D(s) that were estimated from only two original experimental D(s) data were in agreement with corresponding experimental D(s) values, with relative errors of approximately 20%, irrespective of some RPLC conditions.

Journal Article↗

Separation of peptides from myoglobin enzymatic digests by RPLC. Influence of the mobile-phase composition and the pressure on the retention and separation.

The influence of the mobile-phase composition and the pressure on the chromatographic separation of the peptides from the enzymatic digest of myoglobin was studied under linear conditions. The retention behavior of these tryptic peptides was measured under isocratic conditions with different mobile-phase compositions, ranging from 9 to 28% (v/v) acetonitrile in 0.1% (v/v) aqueous trifluoroacetic acid. The effect of the pressure was studied by analyzing the separation of the tryptic peptides under different average column pressures between 14 and 220 bar, at 13, 20, and 26% (v/v) acetonitrile. The differences between the partial molar volumes of these peptides in the stationary and mobile phases were derived from these results. All the measurements were performed on a 10-cm-long C18-bonded, end-capped monolithic column. The results obtained illustrate the highly complicated behavior of the complex peptide mixtures afforded by tryptic digestion. The capacity factors of the analyzed peptides do not depend linearly on the acetonitrile concentration but follow exactly a quadratic relationship. The adsorption changes of partial molar volumes are in good agreement with other literature data. The consequences of the influence of the average column pressure (hence of the flow rate) on the column phase ratio and on the retention factors of the peptides are discussed. The retention pattern of the complex mixture is affected by both the mobile-phase composition and the pressure, and the resolution of certain peptide pairs is so much affected by the pressure that inversions in the elution order of some pairs are observed.

Adsorption↗

Calibration of a detector for nonlinear chromatography.

In many studies of nonlinear or preparative chromatography, chromatographic signals must be recorded for relatively concentrated solutions and the detectors, that are designed for analytical applications and are highly sensitive, must be used under such experimental conditions that their responses are often nonlinear. Then, a calibration curve is needed to derive the actual concentration profiles of the eluates from the measured detector response. It becomes necessary to derive a relationship between the concentration of the eluent and the detector signal at any given time. The simplest approach consists in preparing a series of solutions of known concentrations and in flushing them successively through the detector cell, recording the height of the plateau response obtained. However, this method requires relatively large amounts of the pure solutes being studied and these are not always available or they may be most costly, although these solutions can be recovered. We describe and validate an alternative procedure providing this calibration from a series of peaks recorded upon the injection of increasingly large pulses of the studied compound.

Calibration↗

Influence of the pressure on the properties of chromatographic columns .III. retention volume of thiourea, hold-up volume, and compressibility of the C18-bonded layer.

The influence of the average column pressure (ACP) on the elution volume of thiourea was measured on two RPLC columns, packed with Resolve-C18 (surface coverage 2.45 micromol/m2) and Symmetry-C18 (surface coverage 3.18 micromol/m2), and it was compared to that measured under the same conditions on an underivatized silica (Resolve). Five different methanol-water mixtures (20, 40, 60, 80 and 100% methanol, v/v) were used. Once corrected for the compressibility of the mobile phase, the data show that the elution volume of thiourea increases between 3 and 7% on the C18-bonded columns when the ACP increases from 50 to 350 bar, depending on the methanol content of the eluent. No such increase is observed on the underivatized Resolve silica column. This increase is too large to be ascribed to the compressibility of the stationary phase (silica + C18 bonded chains) which accounts for less than 5% of the variation of the retention factor. It is shown that the reason for this effect is of thermodynamic origin, the difference between the partial molar volume of the solute in the stationary and the mobile phase, Delta V, controlling the retention volume of thiourea. While Delta V is nearly constant for all mobile phase compositions on Resolve silica (with Delta V approximately equal to -4 mL/mol), on RPLC phases, it significantly increases with increasing methanol content, particularly above 60% methanol. It varies between -5 mL/mol and -17 mL/mol on Resolve-C18 and between -9 mL/mol and -25 mL/mol on Symmetry-C18. The difference in surface coverage between these two RP-HPLC stationary phases increases the values of Delta V by about 5 mL/mol.

Chromatography, Liquid↗

Thermodynamic studies of the solvent effects in chromatography on molecularly imprinted polymers. 3. Nature of the organic mobile phase.

Experimental isotherm data of the Fmoc-tryptophan (Fmoc-Trp) enantiomers were measured by frontal analysis on a Fmoc-L-Trp imprinted polymer, using different organic mobile phases, in a wide concentration range. The nonlinear regression of the data and the independent calculation of the affinity energy distributions of the two enantiomers allowed the selection of the isotherm model and the determination of the isotherm parameters. The organic solvents studied were acetonitrile (MeCN), methylene chloride, chloroform, and tetrahydrofuran (THF), all in the presence of the same concentration of acetic acid, used as an organic modifier. It was found that the highest overall affinity and enantiomeric selectivity were obtained in MeCN, which is also the solvent used in the polymerization. In the other solvents, the overall affinity decreases with increasing hydrogen-bonding ability of the solvents but not the enantiomer selectivity. In MeCN, three types of adsorption sites coexist for the two enantiomers on the MIP. The highest energy sites for Fmoc-L-Trp in MeCN are inactive in CH(2)Cl(2), CHCl(3), and THF, and only two types of sites were identified in these solvents. Increasing the acetic acid concentration from 0.2 to 0.9 M causes a large decrease in the association constant of the highest energy sites in CH(2)Cl(2), CHCl(3), and THF but not in MeCN. The overall affinity of Fmoc-L-trp in CH(2)Cl(2), CHCl(3), and THF is dominated by adsorption on the lowest energy sites, the most abundant ones. In contrast, in MeCN, the overall affinity of Fmoc-L-Trp is dominated by adsorption on the highest energy sites, the least abundant sites. In CH(2)Cl(2), CHCl(3), and THF, the number of each type of sites increases with decreasing hydrogen-bonding ability of the solvents while the association constant of the corresponding sites does not change significantly.

Journal Article↗

Influence of the pressure on the properties of chromatographic columns. I. Measurement of the compressibility of methanol-water mixtures on a mesoporous silica adsorbent.

The compressibilities of aqueous solutions of methanol or acetonitrile containing 0, 20, 40, 60, 80 and 100% (v/v) organic solvent were measured with a dynamic chromatographic method. The elution volumes of thiourea samples (2 microL) in these solutions were measured at different average column pressures, adjusted by placing suitable capillary restrictors on-line, after the detector. The reproducibility of the measurements was better than 0.2%. In the range of average pressures studied (10-350 bar), the maximum change in elution volume of thiourea is 1.3% (in pure water) and 4.0% (in pure methanol). This difference is due to the different compressibilities of these pure solvents. For mixtures, the plots of the elution volume of thiourea versus the pressure are convex downward, which is inconsistent with the opposite curvature predicted by the classical Tait model of liquid compressibility. This difference is explained by the variation of the amount of thiourea adsorbed with the pressure. The deconvolution of the two effects, adsorption of thiourea and solvent compressibility, allows a fair and consistent determination of the compressibilities of the methanol-water mixtures. A column packed with non-porous silica particles was also used to determine the compressibility of methanol-water and acetonitrile-water mixtures. A negative deviation by respect to ideal behavior was observed.

Chromatography, Liquid↗

Influence of pressure on the properties of chromatographic columns. II. The column hold-up volume.

The effect of the local pressure and of the average column pressure on the hold-up column volume was investigated between 1 and 400 bar, from a theoretical and an experimental point of view. Calculations based upon the elasticity of the solids involved (column wall and packing material) and the compressibility of the liquid phase show that the increase of the column hold-up volume with increasing pressure that is observed is correlated with (in order of decreasing importance): (1) the compressibility of the mobile phase (+1 to 5%); (2) in RPLC, the compressibility of the C18-bonded layer on the surface of the silica (+0.5 to 1%); and (3) the expansion of the column tube (<0.001%). These predictions agree well with the results of experimental measurements that were performed on columns packed with the pure Resolve silica (0% carbon), the derivatized Resolve-C18 (10% carbon) and the Symmetry-C18 (20% carbon) adsorbents, using water, methanol, or n-pentane as the mobile phase. These solvents have different compressibilities. However, 1% of the relative increase of the column hold-up volume that was observed when the pressure was raised is not accounted for by the compressibilities of either the solvent or the C18-bonded phase. It is due to the influence of the pressure on the retention behavior of thiourea, the compound used as tracer to measure the hold-up volume.

Chromatography, Liquid↗

Effect of the flow rate on the measurement of adsorption data by dynamic frontal analysis.

The adsorption data of propyl benzoate were acquired by frontal analysis (FA) on a Symmetry-C18 column, using a mixture of methanol (65%, v/v) and water as the mobile phase, at three different flow rates, 0.5, 1.0 and 2.0 mL/min. The exact flow rates Fv were measured by collecting the mobile phase in volumetric glasses (deltaFv / Fv < or = 0.2%). The extra-column volumes and the column hold-up volume were accurately measured at each flow rate by tracer injections. The detailed effect of the flow rate on the value of the amount adsorbed was investigated. The best isotherm model accounting for the adsorption data was the same BET isotherm model at all three flow rates. Only slight differences (always less than 5%) were found between the three different sets of isotherm parameters (saturation capacity, q(s), equilibrium constant on the adsorbent, b(s) and equilibrium constant on successive layers of propyl benzoate, bL). The reproducibility of the same isotherm parameters measured by the inverse method (IM) is less satisfactory, leading to R.S.D.s of up to 10%. A flow rate increase is systematically accompanied by a slight increase of the amount adsorbed. This phenomenon is consistent with the influence of the pressure on the equilibrium constant of adsorption due to the difference between the partial molar volumes of the solute and the adsorbate. The larger average pressure along the column that is required to achieve a larger flow rate causes a larger amount of solute to be adsorbed on the column at equilibrium. This result comforts the high sensitivity and versatility of the FA method for isotherm determination under any kind of situation.

Adsorption↗

Thermodynamic studies on the solvent effects in chromatography on molecularly imprinted polymers. 1. Nature of the organic modifier.

Molecularly imprinted polymers (MIPs) are used as highly enantioselective stationary phases in liquid chromatography. To optimize the binding performance of MIPs, different types of polar modifiers are frequently used. Previous studies have shown that the hydrogen-bonding donor parameter (HBD) of the modifier has a large influence on the binding performance of MIPs in chiral separations. This possibility is addressed in a detailed thermodynamic study of a Fmoc-L-tryptophan (Fmoc-L-Trp) imprinted polymer, eluted with four different polar modifiers, i.e., THF, propan-2-ol, methanol, and acetic acid, which have different HBDs (0.00, 0.33, 0.43, and 0.61, respectively). Adsorption isotherm data for each enantiomer in each of these organic modifiers were acquired by frontal analysis over a 20 000 dynamic concentration range. Nonlinear regression of the isotherm data, along with independent calculation of the affinity energy distributions, identified four different types of binding sites coexisting for the enantiomers on the MIP. The exception was acetic acid, which has the highest HBD. In this case, three types of binding sites only coexist on the MIP. The isotherm parameters obtained from these data show the following: (1) The association energies of the two enantiomers with a given type of sites have a similar magnitude; however, the density of the sites is higher for the template than for its antipode. (2) The nature of the organic modifier has a larger influence on the density of high-energy sites than on the association constant of these sites. (3) The molecular size of the organic modifier has a larger influence on the site density (especially for Fmoc-D-Trp) than does HBD. (4) Using an organic modifier with a higher HBD reduces the enantioselectivity on each site. (5) High-energy sites are more enantioselective than low-energy ones. (6) Using an organic modifier with a high HBD causes a larger reduction in the density of high-energy sites approached by the template molecules.

Acetic Acid↗

Thermodynamic studies on solvent effects in molecularly imprinted polymers. 2. Concentration of the organic modifier.

The effects of the organic modifier concentration on the isotherm parameters of the two enantiomers of Fmoc-tryptophan (Fmoc-L,D-Trp) on an Fmoc-L-Trp-imprinted polymer were investigated over a wide concentration range (0.005-100 mM), using frontal analysis. The modifier was acetic acid; concentrations of 0.2, 0.9, 1.7, and 3.7 M in an acetonitrile-based mobile phase were studied. At each concentration, adsorption isotherm data were acquired for each enantiomer. From these data, the isotherm parameters of each compound were derived from nonlinear isotherm fitting and the affinity energy distributions were calculated independently. We found that three types of sites coexist for Fmoc-L-Trp but only two types of sites for Fmoc-D-Trp, except at the lowest acetic acid concentration (0.2 M), at which three types of sites coexist. Increasing the acetic acid concentration decreases the selectivity and the overall affinity of both enantiomers. The overall affinity of Fmoc-L-Trp is dominated by the contribution of the low-density highest energy sites while that of Fmoc-D-Trp is dominated by the most abundant, low-energy sites. For the low-energy sites, increasing the acetic acid concentration affects the association constant of the enantiomers more than the number of corresponding sites. In contrast, for the highest energy sites (sites that exist only for Fmoc-L-Trp), increasing the concentration of acetic acid affects significantly the number of sites but hardly changes the association constant.

Acetic Acid↗