Numerical determination of the adsorption isotherms of tryptophan at different temperatures and mobile phase compositions.

Single-component adsorption isotherm data were acquired by frontal analysis (FA) for tryptophan on a C(18)-Kromasil packed column, using acetonitrile-water solutions of various compositions (2.5, 5, and 7.5% ACN+1% acetic acid) and at five different temperatures between 25 and 65 degrees C. The adsorption isotherm model accounting best for these data is the bi-Moreau model, showing that two types of adsorption sites coexist on the surface and that strong adsorbate-adsorbate interactions take place. Large concentration band profiles of tryptophan were obtained for the three mobile phase compositions, at five different temperatures and the best values of the adsorption isotherm coefficients were determined by the inverse method (IM) of chromatography. The advantages and drawbacks of using the FA and the IM for determining the coefficients of the adsorption isotherm of tryptophan under the experimental conditions selected are discussed. The results of the FA and IM measurements are in good agreement. Both indicate that the retention time of tryptophan decreases rapidly with increasing acetonitrile concentration in the mobile phase as well as the saturation capacities of the two types of adsorption sites, with the highest values of the two saturation capacities being found for the lowest ACN content and the lowest temperature. The adsorption constant on the low-energy sites decreases with increasing acetonitrile content and temperature. In contrast, the adsorption constant on the high-energy sites increases with increasing ACN content of the mobile phase but decreases with increasing temperature. The solute-solute interaction parameters for the low and the high-energy adsorption sites increase rapidly with increasing ACN concentration in the mobile phase and with increasing temperature.

Adsorption↗

Measurement of the axial and radial temperature profiles of a chromatographic column. Influence of thermal insulation on column efficiency.

The temperatures of the metal wall along a chromatographic column (longitudinal temperature gradients) and of the liquid phase across the outlet section of the column (radial temperature gradients) were measured at different flow rates with the same chromatographic column (250 mm x 4.6 mm). The column was packed with 5 microm C18-bonded silica particles. The measurements were carried out with surface and immersion thermocouples (all junction Type T, +/-0.1 K) that measure the local temperature. The column was either left in a still-air bath (ambient temperature, T(ext) = 295-296 K) or insulated in a packing foam to avoid air convection around its surface. The temperature profiles were measured at several values of the inlet pressure (approximately = 100, 200, 300 and 350 bar) and with two mobile phases, pure methanol and a 2.5:97.5 (v/v, %) methanol:water solution. The experimental results show that the longitudinal temperature gradients never exceeded 8 K for a pressure drop of 350 bars. In the presence of the insulating foam, the longitudinal temperature gradients become quasi-linear and the column temperature increases by +1 and +3 K with a water-rich (heat conductivity approximately = 0.6 W/m/K) and pure methanol (heat conductivity approximately = 0.2 W/m/K), respectively. The radial temperature gradients are maximum with methanol (+1.5 K at 290 bar inlet pressure) and minimum with water (+0.8 K at 290 bar), as predicted by the solution of the heat transfer balance in a chromatographic column. The profile remains parabolic all along the column. Combining the results of these measurements (determination of the boundary conditions on the wall, at column inlet and at column outlet) with calculations using a realistic model of heat dispersion in a porous medium, the temperature inside the column could be assessed for any radial and axial position.

Chromatography, Liquid↗

Empirical development of a binary adsorption isotherm based on the single-component isotherms in the framework of a two-site model.

The adsorption behavior of mixtures of the enantiomers of 2,2,2-(trifluoro)-1-(9-anthryl)-ethanol (TFAE) on a quinidine carbamate bonded stationary phase was studied as an example of competitive binary adsorption on a Pirkle-type chiral adsorbent. A model of the adsorption isotherms is proposed and discussed. Binary adsorption isotherms derived by combination of the single-component isotherms of the two enantiomers in the framework of the classical bi-Langmuir model allow the correct prediction of the retention times of the elution bands of the components of binary mixtures but fail properly to predict the separation of the two enantiomers. Use of a quadratic model was needed to improve the agreement between calculated and experimental chromatograms of binary mixtures. The existence of a third type of adsorption sites besides the high-energy enantioselective and the low-energy nonselective sites was assumed. These sites have a low interaction energy, exhibit some affinity toward (S)-TFAE, but none toward (R)-TFAE.

Adsorption↗

Separation of free sterols by high temperature liquid chromatography.

Increasing the column temperature accelerates markedly elution in HPLC. The separation of five free sterols was studied on three packing materials that can withstand high temperatures. These stationary phases included graphitic carbon, a polymeric C18 silica, and a zirconia-based adsorbent. Measurements of retention data were made at up to 150 degrees C with mobile phases of different compositions. Since the columns tested afford different retention mechanisms, a variety of elution patterns were observed, with some being more advantageous than others for certain sterol separations. Effects observed include some selectivity improvements and some elution order reversals. The separation of free sterols in selected fruit juices is also presented. Albeit at the expense of a longer analysis time, the graphitic carbon column produced the best separation of the sterols in this study.

Alkanes↗

Influence of the errors made in the measurement of the extra-column volume on the accuracies of estimates of the column efficiency and the mass transfer kinetics parameters.

The influences of the errors made in the measurement of the extra-column volume of an instrument on the accuracies of the estimates made of the column efficiency and of the parameters of the mass transfer kinetics were investigated from an experimental point of view. A standard HP1090 apparatus (extra-column volume, approximately 50 micro L) was used to measure the efficiency of a Sunfire-C(18) RPLC column (column hold-up volume, approximately 1.50 mL). The first and second moments of the peaks of phenol (a retained compound) and of thiourea (a practically non-retained compound) were measured at six different temperatures between 22 and 78 degrees C, for flow rates between 0.10 and 4.70 mL/min (i.e., for linear velocities between 0.025 and 1.179 cm/s). Each series of measurements was successively made with the instrument being fitted with and without the column. The experimental HETP data must be corrected for the solute dispersion in the connected tubes in order properly to assess the true column efficiency. Even with a modern, high performance instrument, the dispersion of a non-retained compound is essentially due to the band broadening phenomena that take place in the extra-column volumes, the sum of all these extra-column band broadening contributions accounting for more than 80% of the total band broadening measured. The contribution of the sampling device is particularly deleterious since, for a 2 mu L injection, the maximum solute concentration in the peak that enters into the column is nearly ten-fold lower than that of the sample. Nevertheless, the impact of the extra-column volumes on the estimates of the kinetic parameters (e.g., molecular diffusion coefficient D(m) and effective particle diffusivity D(e)) remains negligible. Obviously, the relative error made on the column efficiency of a retained compound depends much on its retention factor. It decreases from 8 to 1% when the retention factor increases from 5 to 17.

Chromatography, Liquid↗

Experimental evidence of the influence of the surface chemistry of the packing material on the column pressure drop in reverse-phase liquid chromatography.

The permeabilities of six columns packed with different packing materials (neat silica, C(1) endcapped silica at 3.92 micro mol/m(2), C(18) bonded and endcapped silica with 0.42, 1.01, 2.03, and 3.15 micro mol/m(2) of C(18) bonded chains) were measured. All these materials derive from the same batch of spherical particles, 5 micro m in diameter. The columns have the same tube inner diameter (phi=0.460+/-0.003 cm) and length (L=15.000+/-0.003 cm). The experimental conditions were the same, flow-rate (F(v)=1.000+/-0.003 mL/min) and temperature (295 K). Nevertheless, it was found that the column permeability decreases significantly, by about 25%, from the neat silica column to the one packed with the highest density of C(18)-bonded silica (3.15 micro mol/m(2)). The results measured on two duplicate columns were very reproducible. Accurate (+/-0.5 %) measurements of the hold-volumes with concentrated and dilute solutions of NO(3)(-) showed that the columns had all nearly the same external porosity. The result cannot be explained by the error made on the volume of the column tube either as it was measured accurately for all the columns. The residual explanation is that the interstitial velocity distribution between the packed particles depends on the chemical nature of the external surface of these particles.

Chromatography, Liquid↗

Visualising viscous fingering in chromatography columns: high viscosity solute plug.

The interface between two fluids that have different viscosities and are percolating through a porous bed is unstable. Sooner or later, a flow instability termed viscous fingering (VF) develops. This phenomenon is important in chromatography because the solute plug does not have the same viscosity as the mobile phase. Because the sample is often much more viscous than the mobile phase, it is the interface at the rear of the sample band that is usually unstable. This situation is frequent in many modes of chromatography, e.g., in preparative and in multidimensional chromatography, in size exclusion chromatography, in frontal analysis, and in other physicochemical measurements (e.g., determination of adsorption isotherms and of mass transfer parameters). When the solute plug is more viscous than the mobile phase, we observed that the solute band compressed. When the viscosity contrast increased up to 0.30 cP, fingers appeared to trail behind the solute plug. The development of fingers then became more substantial as the viscosity contrast increased. To avoid effects associated with VF, the mobile phase and the solute plug should have nearly the same viscosity.

Adsorption↗

Effects of the thermal heterogeneity of the column on chromatographic results.

The influence of the thermal heterogeneity of HPLC columns on retention data was investigated. The retention factor of the retained compound phenol was measured at 24 increasing values of the flow rate, from 0.025 to 4.9 mL/min, on six different packing materials prepared with the same batch of silica particles (5 microm diameter, 90 A pore size). One column was packed with the neat silica particles, another with the silica endcapped with trimethylchlorosilane (TMS)(C(1), 3.92 micromol/m(2)), and the other four with silica first derivatized with octadecyl-dimethyl-chlorosilane (C(18), 0.42, 1.01, 2.03, and 3.15 micromol/m(2)), and second endcapped with TMS. Four different sources of heat contributing to raise the column temperature were considered: (1) the heat supplied by the hot high-pressure pump chamber to the solvent; (2) the adiabatic (dS=0) compression of the solvent in the high-pressure pump; (3) the isenthalpic (dH=0) decompression of the solvent during its migration along the porous chromatographic bed; and (4) the heat released by the friction of the solvent percolating through the column bed. The main contributions appear to be the heat supplied to the solvent by the HP pump and the friction heat. The average column temperature (ACT) was indirectly derived from the measurements of the first moment, mu(1), of phenol peak, of the column pressure drop, DeltaP, and of the retention factors of the phenol peak apices as a function of the flow rate applied. If the column is placed in a still-air bath at 298 K (and its temperature is not externally controlled), a longitudinal temperature gradient is established along the column and the average column temperature is about 6 K higher when this column is operated at 4.9 mL/min than when the flow rate is only 0.025 mL/min. If the column is placed in a heated air bath (temperature controlled at 316 or 338 K), the ACT changes by less than 3 K over the whole flow rate range applied.

Chromatography, High Pressure Liquid↗

Heterogeneity of the adsorption mechanism of low molecular weight compounds in reversed-phase liquid chromatography.

The retention mechanism in RPLC mode was investigated based on the acquisition of adsorption isotherm data by frontal analysis measurements and their modeling. This work is a review of the results of four years of adsorption data measurements. The data were acquired on a wide variety of brands of C18-silica columns (from Akzo Nobel, Bishoff, Hypersil, Merck, Phenomenex, Supelco, Vydac, and Waters) with several low molecular weight compounds such as phenol (94 g/mol), caffeine (194 g/mol), tryptophan (204 g/mol), sodium 2-naphthalenesulfonate (235 g/mol), and propranololium chloride (295 g/mol). The mobile phase was a mixture of methanol and water at variable composition. The adsorption isotherms were all convex upward (langmuirian), and the degree of heterogeneity of the adsorption system was determined from the calculation of the adsorption energy distribution using the expectation-maximization method. The adsorption isotherm parameters (number of types of adsorption sites, surface concentration of each type of site, and difference between the adsorption energies E(i) - E(j) on sites i and j), obtained from the mathematical fit of the adsorption data to the appropriate multi-Langmuir adsorption isotherm model, were analyzed and compared. The results allow the drawing of general conclusions regarding the relationships between the size of the analyte and the adsorption properties (saturation capacities, adsorption energies) characterizing the retention mechanism in RPLC mode for neutral, anionic, and cationic compounds.

Journal Article↗

The limits of the separation power of unidimensional column liquid chromatography.

The practical limit of the separation power of HPLC depends on time, money, and skill. That is it depends on the time available for the analysis, on the quality and performance of the pump and hardware and particularly on the maximum pressure at which the pump can deliver the mobile phase to the column, and on the temperature at which the column can be operated. It also depends on the properties of the packing material selected (e.g., its particle size, its pore geometry, and its connectivity) and on the packing method used since it affects the coefficients of the HETP equation. Finally, it depends on the thermal stability of the sample and the packing material. The complexity of the sample also plays an important role in that it determines whether the analysis should be made under isocratic, isothermal conditions, in gradient elution, in temperature programming, or with a combination of both types of programming. The various phenomena that affect column properties and separation performance are discussed. Past achievements suggest that columns providing efficiencies in excess of a million plates in less than 1 day are within the grasp of current technology. The possibility of further advances are considered.

Animals↗

General HETP equation for the study of mass-transfer mechanisms in RPLC.

Classical HETP equations including the Van Deemter and the Knox equations, are semiempirical, approximate equations that provide apparent mass-transfer coefficients with little sound physical justifications. The conventional A and B coefficients are revisited, the former through the use of the fundamental theory of eddy diffusion due to Giddings, the latter by taking into account the intraparticle diffusion (pore and surface diffusion). Our work confirms that eddy diffusion originated from three different sources in RPLC: trans-channel, short-range interchannel, and long-range interchannel velocity biases. Accordingly, the eddy diffusion term is given by the ratio of two third-degree polynomials. Finally, the C term is the sum of two terms corresponding to the resistance to mass transfer due to diffusion through the external stationary film of liquid phase surrounding the silica particles and to the classical resistances to mass transfer due to diffusion through the silica particles. It is easily related to the physical characteristics of the phenomena involved. Experimental HETP data were derived from moment analysis for phenol on a C(18)-Sunfire column, with a mixture of acetonitrile and water as the mobile phase (15/85, v/v). The linear interstitial velocity ranged between 0.027 cm/s and 4.7 mL/min, and six temperature (21, 36, 45, 55, 67, and 77 degrees C) were applied successively. The HETP equation obtained was tested to study the mass-transfer mechanism. An excellent agreement was found between the experimental and theoretical HETP. The model allows the precise calculation of the activation energy for surface diffusion (E(S) = 31.3 kJ/mol) and the coefficient beta that relates the restriction energy for molecular diffusion on the C(18)-bonded surface to the isosteric heat of adsorption Q(st) (beta = 0.80).

Chemical Phenomena↗

Effect of the density of the C(18) surface coverage on the adsorption mechanism of a cationic compound and on the silanol activity of the stationary phase in reversed phase liquid chromatography.

RPLC columns with different surface coverages (a C(1) endcapped column with a bonding density of 3.92 micromol/m(2) and four C(18)-bonded, endcapped columns, with octadecyl chain densities of 0.42, 1.01, 2.03, and 3.15 micromol/m(2)) were used to investigate the effects of the density of the surface coverage of RPLC columns on the adsorption mechanism of a cationic compound, amitriptyline chloride, and on the silanol activity of these columns. The mobile phases used were acetonitrile-water (30/70, v/v) solutions, buffered at either pH 2.7 or pH 6.9. At pH 2.7, the residual silanol groups are not ionized. At pH 6.9, some of these groups are ionized and these surface anions can strongly interact with the cationic compound. The adsorption isotherms were measured by frontal analysis (FA) at pH 2.7 and by frontal analysis by characteristic points (FACP) at pH 6.9, because the very high retention observed at neutral pH made FA measurements excessively long and poorly accurate. The adsorption energy distributions (AEDs) were calculated when possible, according to the expectation-maximization (EM) algorithm. A bimodal and a trimodal energy distribution were found for all the columns at pH 2.7 and 6.9, respectively. The third site measured at pH 6.9 was attributed to the strong ion-exchange interactions between the ionized silanol groups and the amitriptylinium cation. The contribution of the ionized silanol groups to the overall retention is maximum for the phases with intermediary bonding densities (1.01 and 2.03 micromol/m(2)). The peak tailing is most pronounced for the lowest (C(1) column) and the highest (3.15 micromol/m(2)) surface coverages.

Adsorption↗

Effect of temperature on the adsorption behavior of tryptophan in reversed-phase liquid chromatography.

Single-component adsorption isotherm data of l-tryptophan on a C(18)-bonded silica column were acquired by frontal analysis (FA), with aqueous mobile phases containing 5% of acetonitrile at five different temperatures between 23 and 62 degrees C. The non-linear fitting of these data provided the bi-Moreau model for all temperatures as the best isotherm model. The inverse method (IM) was used to derive the parameters at these temperatures from the parameters of the 25 degrees C isotherm. The adsorption constants and the saturation capacities of the low and high-energy sites decreases by increasing the temperature, while the adsorbate-adsorbate parameters of both sites increase. An excellent agreement was found between the experimental and calculated overloaded band profiles at all the temperatures used. The breakthrough curves obtained and the overloaded band profiles obtained were found to have different shapes according to the range of concentration studied and the temperatures. At low concentration 0.05-0.5 g/L the breakthrough curves and the overloaded band profiles have a front shock and diffuse rear, which indicates langmuirian behavior, but at intermediate 1-2 g/L and high concentration 8 g/L they start to have diffuse fronts and shocks at the rear or more than one shock at the rear which indicates non-langmuirian behavior. At 23 degrees C the isotherm has another langmuirian part, which appears at high concentration. The behavior of the breakthrough curves is explained by the shape of the isotherm in which all of the isotherms have a langmuirian part (the isotherm is concave upward) and an antilangmuirian part (the isotherm is concave downward). The temperature affected the breakthrough curves by decreasing the time of the appearance of the fronts for all concentration ranges studied, and by decreasing the time difference between the highest concentration and lowest concentration of the fronts, especially the low concentration range at 0.5 g/L. The fronts of the breakthrough curves at high concentration seems to be the most affected by temperature.

Acetates↗

Influence of the degree of coverage of C18-bonded stationary phases on the mass transfer mechanism and its kinetics.

The influence of the degree of coverage of a silica surface with bonded C18 alkyl chains on the mass transfer mechanism in RPLC was investigated. Five packing materials were used, prepared with the same batch of silica particles (5 microm diameter, 90 A average pore size): one column was packed with the silica derivatized by trimethylchlorosilane (TMS) (C1, 3.92 micromol/m2), and the other four with the silica first derivatized with octadecyl-dimethyl-chlorosilane (C18, 0.42, 1.01, 2.03, and 3.15 micromol/m2), and then endcapped with TMS. A solution of methanol and water (25/75, v/v) was used as the mobile phase. The experimental HETP curves were acquired for each column by measuring the first moment and the second central moment of phenol and correcting them for the influence of the temperature increase due to the heat generated by the friction of the stream against the bed. The different kinetic parameters of the mass transfer in these packed chromatographic columns were identified (longitudinal diffusion, eddy diffusion, film mass transfer, and transparticle mass transfer) and quantified by fitting the experimental data to a new general HETP equation recently derived [F. Gritti, G. Guiochon, Anal. Chem., in press (AC-060203R).]. The agreement was excellent and allowed the comparison of the kinetic parameters among the six columns used. The highest column efficiency measured at conventional or fast flow rates (>0.5 ml/min) is obtained for the most retentive column, which has a surface coverage of 2.03 micromol/m2. The smallest HETP measured is as low as 10 microm, only twice the average particle diameter dp, due to the large contribution of surface diffusion (90%) to the particle effective diffusivity. However, no significant difference was observed between the efficiencies of the columns packed with C1 and C18 derivatized silica.

Chromatography, High Pressure Liquid↗

Adsorption mechanisms and effect of temperature in reversed-phase liquid chromatography. meaning of the classical Van't Hoff plot in chromatography.

The effect of temperature on the adsorption and retention behaviors of a low molecular weight compound (phenol) on a C18-bonded silica column (C18-Sunfire, Waters) from aqueous solutions of methanol (20%) or acetonitrile (15%) was investigated. The results of the measurements were interpreted successively on the basis of the linear (i.e., overall retention factors) and the nonlinear (i.e., adsorption isotherms, surface heterogeneity, saturation capacities, and equilibrium constants) chromatographic methods. The confrontation of these two approaches confirmed the impossibility of a sound physical interpretation of the conventional Van't Hoff plot. The classical linear chromatography theory assumes that retention is determined by the equilibrium thermodynamics of analytes between a homogeneous stationary phase and a homogeneous mobile phase (although there may be two or several types of interactions). From values of the experimental retention factors in a temperature interval and estimates of the activity coefficients at infinite dilution in the same temperature interval provided by the UNIFAC group contribution method, evidence is provided that such a retention model cannot hold. The classical Van't Hoff plot appears meaningless and its linear behavior a mere accident. Results from nonlinear chromatography confirm these conclusions and provide explanations. The retention factors seem to fulfill the Van't Hoff equation, not the Henry constants corresponding to the different types of adsorption sites. The saturation capacities and the adsorption energies are clearly temperature dependent. The temperature dependence of these characteristics of the different assorption sites are different in aqueous methanol and acetonitrile solutions.

Adsorption↗

Visualising the onset of viscous fingering in chromatography columns.

Viscous fingering is an important fluid transport phenomenon that manifests itself when two fluids having different viscosities move in the same direction. Their interface is unstable and a complex fingering pattern may arise. This phenomenon is important in chromatography because it may lead to a decrease or even a failure in separations. The onset of viscous fingering was visually observed by packing a glass column with particles having the same refractive index as the mobile phase and injecting plugs of dye solutions having viscosities different from that of the mobile phase. Severe fingering effects are observed if the viscosity difference exceeds 0.17 cP. However, for smaller viscosity differences, band distortions are observed that may affect retention data, band efficiency, and band resolution. Careful attention should be paid to matching the mobile phase viscosity and that of the injection plug when accurate chromatographic information is required.

Chromatography, High Pressure Liquid↗

Adsorption mechanism in reversed-phase liquid chromatography. Effect of the surface coverage of a monomeric C18-silica stationary phase.

The effect of the bonding density of the octadecyl chains onto the same silica on the adsorption and retention properties of low molecular weight compounds (phenol, caffeine, and sodium 2-naphthalene sulfonate) was investigated. The same mobile phase (methanol:water, 20:80, v/v) and temperature (T = 298 K) were applied and two duplicate columns (A and B) from each batch of packing material (neat silica, simply endcapped or C1 phase, 0.42, 1.01, 2.03, and 3.15 micromol/m2 of C18 alkyl chains) were tested. Adsorption data of the three compounds were acquired by frontal analysis (FA) and the adsorption energy distributions (AEDs) were calculated using the expectation-maximization method. Results confirmed earlier findings in linear chromatography of a retention maximum at an intermediate bonding density. From a general point of view, the saturation capacity of the adsorbent tends to decrease with increasing bonding density, due to the vanishing space intercalated between the C18 bonded chains and to the decrease of the specific surface area of the stationary phase. The equilibrium constants are maximum for an intermediary bonding density (approximately 2 micromol/m2). An enthalpy-entropy compensation was found for the thermodynamic parameters of the isotherm data. Weak equilibrium constants (small deltaH) and high saturation capacities (large deltaS) were observed at low bonding densities, higher equilibrium constants and lower saturation capacities at high bonding densities, the combinations leading to similar apparent retention in RPLC. The use of a low surface coverage column is recommended for preparative purposes.

Adsorption↗

Effect of the mobile phase composition on the adsorption behavior of tryptophan in reversed-phase liquid chromatography.

Single-component adsorption isotherm data of l-tryptophan on a C18-bonded silica column were acquired by frontal analysis (FA), with aqueous mobile phases containing 2.5, 5, and 7.5% of acetonitrile (ACN) or 7, 10, 15, and 20% of methanol (MeOH). Most of these isotherms have two inflection points and three different parts. The low and the high concentration parts exhibit langmuirian behavior. The intermediate part exhibits anti-langmuirian behavior. The inflection points shift toward higher concentrations with increasing mobile phase concentration in ACN or MeOH, which causes the differences in the isotherm profiles. The nature of the organic modifier and its concentration affect only the isotherm profile and the numerical values of its parameters, not the nature of the best model, which is the bi-Moreau model in all cases. The isotherm profiles depend on the experimental conditions because they affect the intensity of the adsorbate-adsorbate interactions. Overloaded band profiles of tryptophan were recorded with the seven mobile phase compositions. They were used to determine the best values of the isotherm coefficients by the inverse method (IM) of chromatography. There is an excellent agreement between the values of these parameters obtained by FA and by IM. Increasing the concentration of either ACN or MeOH in the mobile phase causes a slight decrease in the saturation capacities of the low and the high energy sites, and in the adsorption constant of the low energy sites. The adsorption constant of the high energy sites increases with increasing concentration of either solvent or is little affected. The adsorbate-adsorbate interaction constants of both low and high energy sites increase for both solvents. Saturation capacities of the high energy sites are higher for ACN than for MeOH.

Acetonitriles↗