Search PubMed⌕ Search

Biomedical subjects

Ge Wang

Publications and source records attributed to Ge Wang.

At least 73 records · Page 4Linked to original sources

An error-reduction-based algorithm for cone-beam computed tomography.

Image reconstruction from cone-beam projections collected along a single circular source trajectory is commonly done using the Feldkamp algorithm, which performs well only with a small cone angle. In this report, we propose an error-reduction-based algorithm to increase the cone angle by several folds to achieve satisfactory image quality at the same radiation dose. In our scheme, we first reconstruct the object using the Feldkamp algorithm. Then, we synthesize cone-beam projection data from the reconstructed volume in the same geometry, and reconstruct the volume again from the synthesized projections. Finally, these two reconstruction results are combined to reduce the reconstruction error and produce a superior image volume. The merit of this algorithm is demonstrated in numerical simulation.

Algorithms↗

An NADPH quinone reductase of Helicobacter pylori plays an important role in oxidative stress resistance and host colonization.

Oxidative stress resistance is one of the key properties that enable pathogenic bacteria to survive the toxic reactive oxygen species released by the host. In a previous study characterizing oxidative stress resistance mutants of Helicobacter pylori, a novel potential antioxidant protein (MdaB) was identified by the observation that the expression of this protein was significantly upregulated to compensate for the loss of other major antioxidant components. In this study, we characterized an H. pylori mdaB mutant and the MdaB protein. While the wild-type strain can tolerate 10% oxygen for growth, the growth of the mdaB mutant was significantly inhibited by this oxygen condition. The mdaB mutant is also more sensitive to H(2)O(2), organic hydroperoxides, and the superoxide-generating agent paraquat. Although the wild-type strain can survive more than 10 h of air exposure, exposure of the mutant strain to air for 8 h resulted in recovery of no viable cells. The oxidative stress sensitivity of the mdaB mutant resulted in a deficiency in the ability to colonize mouse stomachs. H. pylori was recovered from 10 of 11 mouse stomachs inoculated with the wild-type strain, with about 5,000 to 45,000 CFU/g of stomach. However, only 3 of 12 mice that were inoculated with the mdaB mutant strain were found to harbor any H. pylori, and these 3 contained less than 2,000 CFU/g of stomach. A His-tagged MdaB protein was purified and characterized. It was shown to be a flavoprotein that catalyzes two-electron transfer from NAD(P)H to quinones. It reduces both ubiquinones and menaquinones with similar efficiencies and preferably uses NADPH as an electron donor. We propose that the physiological function of the H. pylori MdaB protein is that of an NADPH quinone reductase that plays an important role in managing oxidative stress and contributes to successful colonization of the host.

Animals↗

[Report of a rare distal arthrogrophy large family].

We describe a seven-generation large family with talipomanus and talipes, 175 individuals in this family were involved. 32 affected individuals including 18 males and 14 females whose clinical features were different and 1 suspicious male were found. The talipomanus were symmetrical, and varus and valgus were caused by vertical talus. We investigated their living environment, the dietary habit, obstetrical history, physical status, lifespan, and studied cytogenetics and so on. We propose these defects were rare distal arthrogrophy genetic disease.

Adult↗

C-terminal amino acids of Helicobacter pylori alpha1,3/4 fucosyltransferases determine type I and type II transfer.

The alpha1,3/4 fucosyltransferase (FucT) enzyme from Helicobacter pylori catalyzes fucose transfer from donor GDP-beta-l-fucose to the GlcNAc group of two series of acceptor substrates in H. pylori lipopolysaccharide: betaGal1,3betaGlcNAc (Type I) or betaGal1,4betaGlcNAc (Type II). Fucose is added either in alpha1,3 linkage of Type II acceptor to produce Lewis X or in alpha1,4 linkage of Type I acceptor to produce Lewis A, respectively. H. pylori FucTs from different strains have distinct Type I or Type II substrate specificities. FucT in H. pylori strain NCTC11639 has an exclusive alpha1,3 activity because it recognizes only Type II substrates, whereas FucT in H. pylori strain UA948 can utilize both Type II and Type I acceptors; thus it has both alpha1,3 and alpha1,4 activity, respectively. To identify elements conferring substrate specificity, 12 chimeric FucTs were constructed by domain swapping between 11639FucT and UA948FucT and characterized for their ability to transfer fucose to Type I and Type II acceptors. Our results indicate that the C-terminal region of H. pylori FucTs controls Type I and Type II acceptor specificity. In particular, the highly divergent C-terminal portion, seven amino acids DNPFIFC at positions 347-353 in 11639FucT, and the corresponding 10 amino acids CNDAHYSALH at positions 345-354 in UA948FucT, controls the Type I and Type II acceptor recognition. This is the opposite of mammalian FucTs where acceptor preference is determined primarily by the N-terminal residues in the hypervariable stem domain.

Amino Acid Sequence↗

Automatic measurement of the labyrinth using image registration and a deformable inner ear atlas.

RATIONALE AND OBJECTIVES: This article presents a new method for measuring the shape of the cochlea, vestibule, semi-circular canals, and internal auditory canal using image registration and a deformable inner ear atlas. MATERIALS AND METHODS: Computed tomography images of the inner ear are analyzed by placing them into a common orientation and then registering a digital atlas of the inner ear to the data set. The atlas is deformed from its original shape to match the shape of the inner ear in the computed tomography data set using inverse consistent elastic image registration. This process produces an individualized inner ear atlas containing subject-specific measurements and segmentations of the inner ear anatomy in the target computed tomography data set. The shape measurements include the volume and length of the cochlea, vestibule, semi-circular canals, and internal auditory canal; and the angles between the semi-circular canals. RESULTS: A simulated population of inner ear shapes were generated based on the shape of a real population of inner ear shapes and were used to characterize the measurement error of this method. The deformable atlas was used to measure the shape of the left and right inner ear of six individuals. CONCLUSION: Measurement error for 15 of the 24 measurements of our simulated population had an average error of less than 1% and only one measurement had an average error greater than 2.54%. The deformable human inner ear atlas shows promise as a new method for automatically measuring the shape of the labyrinth.

Adult↗

Spatial variation of resolution and noise in multi-detector row spiral CT.

RATIONALE AND OBJECTIVES: The authors performed this study to evaluate an approach for measuring the variations of three-dimensional spatial resolution and image noise throughout a field of view imaged with multi-detector row spiral computed tomographic (CT) scanners. MATERIALS AND METHODS: The authors designed a phantom (diameter, 320 mm) that contained 37 metallic spheres (diameter, approximately 0.8 mm) positioned between two disks made of a material with attenuation being that of water. One sphere was located at the isocenter of the phantom, and the rest were evenly spaced in three concentric rings with diameters of 100, 200, and 300 mm, respectively. The phantom was imaged with two widely used multi-detector row CT scanners by using a standard protocol and four variations of that protocol. Because a recently developed theory holds that image resolution should be proportional to the square root of the trace of the covariance matrix of a point spread function, the authors developed a software package to segment high-attenuation spheres from the CT image volume and compute point spread functions from blurred images of the spheres. Three-dimensional spatial resolution and image noise were calculated as a function of radial distance within the field of view. RESULTS: Resolution and noise were quantified in the resultant CT image volumes and found to be nonisotropic, with worse resolution and less noise occurring at the periphery of the field of view. CONCLUSION: The method enabled measurement of variations in spatial resolution and of their distribution on images obtained with multi-detector row CT scanners. These findings may contribute to the development of an improved algorithm for image reconstruction.

Humans↗

Convergence studies on iterative algorithms for image reconstruction.

We introduce a general iterative scheme for image reconstruction based on Landweber's method. In our configuration, a sequential block-iterative (SeqBI) version can be readily formulated from a simultaneous block-iterative (SimBI) version, and vice versa. This provides a mechanism to derive new algorithms from known ones. It is shown that some widely used iterative algorithms, such as the algebraic reconstruction technique (ART), simultaneous ART (SART), Cimmino's, and the recently designed diagonal weighting and component averaging algorithms, are special examples of the general scheme. We prove convergence of the general scheme under conditions more general than assumed in earlier studies, for its SeqBI and SimBI versions in the consistent and inconsistent cases, respectively. Our results suggest automatic relaxation strategies for the SeqBI and SimBI versions and characterize the dependence of the limit image on the initial guess. It is found that in all cases the limit is the sum of the minimum norm solution of a weighted least-squares problem and an oblique projection of the initial image onto the null space of the system matrix.

Algorithms↗

Blind deblurring of spiral CT images.

To discriminate fine anatomical features in the inner ear, it has been desirable that spiral computed tomography (CT) may perform beyond their current resolution limits with the aid of digital image processing techniques. In this paper, we develop a blind deblurring approach to enhance image resolution retrospectively without complete knowledge of the underlying point spread function (PSF). An oblique CT image can be approximated as the convolution of an isotropic Gaussian PSF and the actual cross section. Practically, the parameter of the PSF is often unavailable. Hence, estimation of the parameter for the underlying PSF is crucially important for blind image deblurring. Based on the iterative deblurring theory, we formulate an edge-to-noise ratio (ENR) to characterize the image quality change due to deblurring. Our blind deblurring algorithm estimates the parameter of the PSF by maximizing the ENR, and deblurs images. In the phantom studies, the blind deblurring algorithm reduces image blurring by about 24%, according to our blurring residual measure. Also, the blind deblurring algorithm works well in patient studies. After fully automatic blind deblurring, the conspicuity of the submillimeter features of the cochlea is substantially improved.

Algorithms↗

A pointwise limit theorem for filtered backprojection in computed tomography.

Computed tomography (CT) is one of the most important areas in the modern science and technology. The most popular approach for image reconstruction is filtered backprojection. It is essential to understand the limit behavior of the filtered backprojection algorithms. The classic results on the limit of image reconstruction are typically done in the norm sense. In this paper, we use the method of limited bandwidth to handle filtered backprojection-based image reconstruction when the spectrum of an underlying image is not absolutely integrable. Our main contribution is, assuming the method of limited bandwidth, to prove a pointwise limit theorem for a class of functions practically relevant and quite general. Further work is underway to extend the theory and explore its practical applications.

Algorithms↗

A Grangeat-type half-scan algorithm for cone-beam CT.

Modern CT and micro-CT scanners are rapidly moving from fan-beam toward cone-beam geometry. Half-scan CT algorithms are advantageous in terms of temporal resolution, and widely used in fan-beam and cone-beam geometry. While existing half-scan algorithms for cone-beam CT are in the Feldkamp framework, in this paper we compensate missing data explicitly in the Grangeat framework, and formulate a half-scan algorithm in the circular scanning case. The half-scan spans 180 degrees plus two cone angles that guarantee sufficient data for reconstruction of the midplane defined by the source trajectory. The smooth half-scan weighting functions are designed for the suppression of data inconsistency. Numerical simulation results are reported for verification of our formulas and programs. This Grangeat-type half-scan algorithm produces excellent image quality, without off-mid-plane artifacts associated with Feldkamp-type half-scan algorithms. The Grangeat-type half-scan algorithm seems promising for quantitative and dynamic biomedical applications of CT and micro-CT.

Algorithms↗

X-ray micro-CT with a displaced detector array: application to helical cone-beam reconstruction.

In x-ray micro-CT applications, it is useful to increase the field of view by offsetting a two-dimensional (2D) detector array. In this technical note, we briefly review the methods for image reconstruction with an asymmetric 2D detector array, elaborate on the use of an associated weighting scheme in the case of helical/spiral cone-beam scanning, and perform a series of numerical tests to demonstrate helical cone-beam image reconstruction with such an arrangement.

Algorithms↗

Blind deblurring of spiral CT images-comparative studies on edge-to-noise ratios.

A recently developed blind deblurring algorithm based on the edge-to-noise ratio has been applied to improve the quality of spiral CT images. Since the discrepancy measure used to quantify the edge and noise effects is not symmetric, there are several ways to formulate the edge-to-noise ratio. This article is to investigate the performance of those ratios with phantom and patient data. In the phantom study, it is shown that all the ratios share similar properties, validating the blind deblurring algorithm. The image fidelity improvement varies from 29% to 33% for different ratios, according to the root mean square error (RMSE) criterion; the optimal iteration number determined for each ratio varies from 25 to 35. Those ratios that are associated with most satisfactory performance are singled out for the image fidelity improvement of about 33% in the numerical simulation. After automatic blind deblurring with the selected ratios, the spatial resolution of CT is substantially refined in all the cases tested.

Algorithms↗

X-ray micro-CT with a displaced detector array.

Because the sizes of samples differ in x-ray micro-CT applications, it is desirable to have a mechanism to change the field of view of a micro-CT scanner. A well-known way to double the diameter of the field of view is to displace a detector array by 50%. In this paper, we propose to displace a detector array by an amount of greater than 0% but less than 50% for a continuously adjustable field of view, and formulate a weighting scheme for artifact-free reconstruction. Then, we perform numerical simulation with the Shepp-Logan phantom to demonstrate the feasibility in fan-beam and cone-beam geometry.

Computer Simulation↗

A knowledge-based cone-beam x-ray CT algorithm for dynamic volumetric cardiac imaging.

With the introduction of spiral/helical multislice CT, medical x-ray CT began a transition into cone-beam geometry. The higher speed, thinner slice, and wider coverage with multislice/cone-beam CT indicate a great potential for dynamic volumetric imaging, with cardiac CT studies being the primary example. Existing ECG-gated cardiac CT algorithms have achieved encouraging results, but they do not utilize any time-varying anatomical information of the heart, and need major improvements to meet critical clinical needs. In this paper, we develop a knowledge-based spiral/helical multislice/cone-beam CT approach for dynamic volumetric cardiac imaging. This approach assumes the relationship between the cardiac status and the ECG signal, such as the volume of the left ventricle as a function of the cardiac phase. Our knowledge-based cardiac CT algorithm is evaluated in numerical simulation and patient studies. In the patient studies, the cardiac status is estimated initially from ECG data and subsequently refined with reconstructed images. Our results demonstrate significant image quality improvements in cardiac CT studies, giving clearly better clarity of the chamber boundaries and vascular structures. In conclusion, this approach seems promising for practical cardiac CT screening and diagnosis.

Algorithms↗

Artifacts associated with implementation of the Grangeat formula.

To compensate for image artifacts introduced in approximate cone-beam reconstruction, exact cone-beam reconstruction algorithms are being developed for medical x-ray CT. Although the exact cone-beam approach is theoretically error-free, it is subject to image artifacts due to the discrete nature of numerical implementation. We report a study on image artifacts associated with the Grangeat algorithm as applied to a circular scanning locus. Three types of artifacts are found, which are thorn, wrinkle, and V-shaped artifacts. The thorn pattern is created by inappropriate extrapolation into the shadow zone in the radon domain. If the shadow zone is filled in with continuous data, the thorn artifacts along the boundary of the shadow zone can be removed. The wrinkle appearance arises if interpolated first derivatives of the radon data are not smooth between adjacent detector planes. In particular, the nearest-neighbor interpolation method should not be used. If the number of projections is not small, the bilinear interpolation method is effective to suppress the wrinkle artifacts. The V-shaped artifacts on the meridian plane come from the line integrations through the transition zones where derivative data change abruptly. Two remedies are to increase the sampling rate and suppress data noise.

Algorithms↗