Dynamics of extravascular lung water in major burns.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to G Sommer.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The sensitivity of the radiofibrinogen test was investigated to determine the accuracy of the test in diagnosis of venographically proven venous thrombosis in 70 heparinized patients. 125J-fibrinogen was administered between 2 h and 4 days (mean: 1.5 days) after initiating heparin therapy. There were two criteria for a positive test: if the difference between the counts for adjacent points on the same leg or equivalent sites on opposite legs was at least 15%; and/or if there were three adjacent points each with counts greater than 5% that of the same three points on the other leg. The fibrinogen uptake test was positive at the first examination in 67 of 70 patients, giving a sensitivity of 96%. The respective frequencies of truly abnormal results for the 3 X 5% and the 1 X 15% criteria were 94% and 71%. As far as localization and extension of thrombosis were concerned, the fibrinogen uptake test agreed with phlebography in 73% of the cases, when the counts in the groin and the upper third of the thigh were ignored. The 125J-fibrinogen uptake test is an accurate method for detecting established deep leg vein thrombosis even in anticoagulated patients.
In an attempt to evaluate the dynamics of fatty acid metabolism after aortocoronary bypass grafting (ACBG), ten patients were investigated after ACBG by 123I-HDA myocardial scintigraphy. Tracer kinetics were followed for 90 min and compared to those of 36 nongrafted patients with different underlying heart diseases, including healthy volunteers. Regional analysis and monoexponential curve fitting were used to evaluate t1/2 (half-life of the early period of tracer elimination); biexponential curve analysis was used to calculate Ca/Cb, the ratio of a fast and a slow component of tracer elimination. Rest and stress MUGA-RNV served as discriminating parameters to discern between patient groups with normal and abnormal ventricular function. Group I (normal controls) encompassed ten patients with normal ventricular function, including three after ACBG, and group II seven patients after ACBG and with abnormal ventricular function. Group III had coronary artery disease (CAD) documented by angiography, and group IV by prior myocardial infarction (MI). Group V included patients with cardiomyopathy (CMP). Regional analysis of group II revealed no significant differences to control regions (Gr I) for t1/2 or Ca/Cb, but showed for Ca/Cb a nonsignificant shift toward group III values. However, group II differed significantly from group III and V. Three patients with normal ventricular function after ACBG showed elimination values that were all well within the range of completely normal individuals. Thus our data support the assumption that a normal function is indicative of a normal metabolism. Following myocardial fatty acid metabolism during rest might be a helpful noninvasive tool for etiologic differentiation of disturbed ventricular function.
Explore the source record for details and available documents.
In 41 patients with chronic obstructive pulmonary disease (COPD) and pulmonary hypertension, the effects of sublingual administration of 20 mg nifedipine and 0.8 mg nitroglycerin on the hemodynamics were assessed at rest and during bicycle ergometry. Additionally, in six patients, the effects of nifedipine during longterm treatment were analyzed. On acute testing, at rest and during exercise nifedipine led to decreases in mean pulmonary artery pressure of 16% and 23% and pulmonary arteriolar resistance of 23 and 35%, respectively, in 81% (17/21) of the patients. The reduction in the pulmonary vascular resistance was greater than that of the systemic resistance. In all patients, cardiac output increased. There was a similar number of responders to nitroglycerin (16/20). The reductions in mean pulmonary artery pressure and pulmonary arteriolar resistance ranging between 20 and 25% at rest and during exercise were comparable to those affected by nifedipine. In addition to the right ventricular afterload reduction, there was a decrease in cardiac output of 17%. During longterm treatment with nifedipine (average 18 months), the reduction in mean pulmonary artery pressure and pulmonary arteriolar resistance was not of the same magnitude as seen on acute testing. This may be due primarily to progression of the underlying disease since pulmonary function studies demonstrated an increase in the obstructive component. With the intention of circumventing or postponing the onset of right ventricular failure, the individual patient should undergo hemodynamic studies to delineate the optimal medication.
The absorption and scattering in bones with and without metal implants (femur, humerus, ramus mandibulae) is investigated in an automatic water phantom by means of thermoluminescent dosimetry, a semi-conductor detector, and the ionization measuring chamber for different types of radiation. In case of Co-60 gamma radiation a strong back scattering is observed which increases the dose by up to 50% at the side of entry of radiation and reduces the dose at the other side by equally up to 50%. If ultrahard X-radiation of 9 MeV is used under the same conditions, there is considerably less back scattering and an increased forward scattering. Electron radiation of 10 MeV causes a considerable dose increase of up to 45% due to back scattering.
A case of complete heart block during right heart Swan-Ganz balloon-tipped flow-directed catheterization in a patient with intermittent left bundle branch block after aortic valve replacement is reported. After entrance into the right ventricle with the catheter tip as well as after insertion of a temporary balloon-floated pacemaker electrode symptomatic complete heart block occurred. This case demonstrates that in a patient with intermittent left bundle branch block a complete AV block may occur and therefore the possibility of cardiopulmonary resuscitation and temporary pacing has to be taken in account.
Measurement of extravascular lung water (EVLW) was performed by the thermal-dye technique in 55 critically ill patients. The EVLW values were compared with the corresponding radiographic, hemodynamic and functional pulmonary data. EVLW values revealed a positive correlation with the chest X-ray score (CXR) (r = 0.836; p less than 0.001), mean pulmonary artery pressure (PP) (r = 0.414; p less than 0.01), pulmonary capillary wedge pressure (PCWP) (r = 0.353; p less than 0.01), venous admixture (Qs/Qt) (r = 0.288; p less than 0.05), and alveo-arterial oxygen difference/fraction of inspired oxygen (AaDO2/FiO2) (r = 0.441; p less than 0.001). No correlation was found between EVLW values and colloid-osmotic pressure minus PCWP (COP-PCWP) (r = 0.221). Though different positive correlations between EVLW values and these parameters were found, they cannot replace EVLW measurement. Rather, EVLW measurement provides additional information on the degree of pulmonary edema which is useful in differentiating between cardiac and non-cardiac pulmonary edema and in states of radiologic over- or underestimation of EVLW.
Radiological staging of pulmonary oedema was compared with the determination of extra-vascular lung water by means of a double indicator dilution technique. One hundred and forty-six ward chest radiographs were evaluated and compared with the results of simultaneous measurements of lung water. Seventy-seven cases could be evaluated statistically. Chest x-rays regarded as normal corresponded to extra-vascular lung water of 5 to 9 ml./kg. body weight. Interstitial oedema (radiological stage I and II) corresponded to extravascular lung water levels of 8 to 12 ml./kg. Differentiation of stages I and II was not possible. During stage III, extra-vascular lung water was 15 to 21 ml./kg. A comparative analyses of these findings revealed a discrepancy of 34%. The reasons for this are discussed.
Traumata of the orbita usually affect the bony parts of the orbit, in rare cases foreign bodies are found within the orbita. Also in the latter cases usually there are no difficulties in finding the correct diagnosis due to marked trauma also to the anterior ocular segments. But as to be shown, large intraorbital foreign bodies may be present despite of only minute trauma to the anterior segments, a fact which may easily lead to a false diagnosis.
Out of 12 000 sonographic examinations of the abdomen in 211 cases the gallbladder was not visualized. The retrospective analysis of 41 patients revealed in 75% gallstones, in 15% space occupying lesions (4 carcinomas, 1 abscess, 1 sludge). In 10% the sonography gave a false positive result. The reasons are discussed.
Explore the source record for details and available documents.
70 patients with established diffuse liver disease (steatosis, fibrosis, cirrhosis) were investigated by sonography and scintigraphy. Sonographic parenchymal morphology and scintigraphic activity pattern were correlated with the histological diagnosis. Scintigraphy as a functional diagnostic technique revealed early fibrotic changes of the liver not seen by ultrasound. Cirrhosis could be demonstrated equally by both methods. The two major advances of ultrasound were: high accuracy in steatosis and ability of simultaneous analysis of the other abdominal organs.
Extravascular lung water (EVLW) was estimated in 53 critically ill patients by the chest radiograph (CXR) and the thermal dye technique. The comparison between these two methods revealed a direct and positive correlation (r = 0.83, p less than 0.001). However, EVLW-values obtained by the thermal dye technique showed considerable overlap between cases of radiographic low grade pulmonary edema and we were able to identify several reasons for radiographic over- or underestimation of EVLW. In these patients EVLW-measurement by the thermal dye technique provides additional information, thereby probably influencing further treatment.
The results of 293 examinations of the skull by sonography in 170 newborn are presented. In 73 patients the results could be compared with the findings on CT or at post mortem. In 48%, abnormal sonograms of the skull were obtained, due to congenital abnormalities, hydrocephalus or intracerebral bleeds. High accuracy and wide application make real time sonography the diagnostic procedure of first choice for the examination of the brain of the newborn. An attempt has been made to determine the optimum time for the examination and suitable intervals for follow-up.
The incidence of postphlebographic venous thrombosis was investigated by 125I-labeled fibrinogen uptake tests in 60 patients whose veins were flushed with saline solution containing 10,000 IU of heparin after leg phlebography. Ionic methylglucamine iodamide was used as the contrast medium. In six patients superficial thrombophlebitis extending from the contrast-medium injection site was observed after phlebography. The incidence of deep venous thrombosis was 3.3%, significantly less than that reported for studies using triiodinated ionic contrast media without flushing the veins with a heparin solution. It is comparable to the incidence of venous thrombosis reported after using nonionic contrast media. The authors conclude that flushing the veins with heparinized saline solution can improve the safety of phlebography considerably.
Explore the source record for details and available documents.