Harmonic imaging--a new method for the sonographic assessment of cerebral perfusion.

In this review, methodological aspects of cerebral perfusion imaging with ultrasound signal enhancing agents are described. The various experimental bases, contributing to the understanding of the phenomena are summarised and the resulting human investigation techniques are illustrated. By means of harmonic imaging technology, human cerebral perfusion can be depicted as a two-dimensional scan. The two major principles of contrast measurement are analysis of the bolus kinetics and analysis of the refill kinetics. Using the bolus method, hypoperfused areas in stroke patients can be visualised and parameter images of wash-in and wash-out curves can be generated off-line. The recently developed theory on the refill kinetics of UCA enables us to calculate quantitative parameters for the description of the cerebral microcirculation, being less affected by the depth dependence of the contrast effect. These parameters, too, can be visualised as parameter images. The ultrasound methods described in this article represent new minimal-invasive bedside techniques for analysing brain perfusion. Although their development is still in an early state, the potential of these ultrasound technologies to compete with perfusion-CT, perfusion-MRI or single-photon emission computed tomography in the diagnostic arsenal of brain imaging techniques is becoming evident.

Albumins↗

Transcranial sonography of brain tumors in the adult: an in vitro and in vivo study.

BACKGROUND: Few reports indicate the potential of transcranial sonography (TCS) in detecting human brain tumors. METHODS: With an Agilent Sonos 2500 ultrasound device, the authors studied 4 brain tumor phantoms and compared the findings with magnetic resonance imaging (MRI). TCS was performed on 40 patients with intracranial tumors in a follow-up design. Sonographic tumor volume and affection of the ventricular system were compared with MRI findings. RESULTS: The authors found a good correlation between TCS and MRI volumetry in the in vitro study. TCS showed good intraobserver and interobserver reliability. A new volumetric formula for TCS measurement was determined. TCS detection rate of brain tumors in vivo was 40%. When the investigators were given access to radiological findings, the rate of tumor identification was 80%. Despite a sufficient acoustic window, 40% of gliomas grade II and III were not detected. One glioblastoma was not identified owing to an insufficient temporal acoustic window. Tumor volumes measured with MRI and TCS correlated well. MRI volumes exceeded TCS volumes by 41%. In the postoperative examinations (mean = 8 days postoperative, n = 15), the resection cavity was displayed as hyperechogenic. It appeared impossible to differentiate between residual tumor tissue and normal repair mechanisms or blood. In the follow-up examination (mean = 99 days postoperative, n = 15) in 5 patients, neither MRI nor TCS showed tumor regrowth. Ten patients had residual tumors that were detected by sonography. CONCLUSIONS: The value of TCS for the diagnostics of brain tumors is at present limited. Once the tumor has been identified, sonographic results match well with those of MRI.

Adolescent↗

Pharmacokinetics of echocontrast agent infusion in a dog model.

Ultrasound contrast agents (UCAs) have a distinct diagnostic impact on transcranial Doppler (TCD) and duplex sonography. In addition to the properties of the UCA and ultrasound imaging modes, the duration of contrast enhancement depends on the administration mode. Infusion of UCAs may be appropriate for prolonging the diagnostically useful time of elevated Doppler intensity. Five sedated dogs were investigated by TCD during infusion with SonoVue, a new UCA consisting of sulfur hexafluoride microbubbles. The infusion rate was varied, and the time-intensity curves were analyzed. Infusion rate of 70 ml/h provided a stable mean level of increased Doppler intensity up to 24 to 26 dB over baseline, whereas a rate of 35 ml/h did not result in a stable plateau (range 8-19 dB over baseline [5 minutes after starting time]). The maximum increases in Doppler mean intensity (18.2 dB [35 ml/h] and 25.6 dB [70 ml/h]) were significantly different (P = .025). Pharmacokinetic analysis of SonoVue during inflow (by exponential functional fitting of the time-mean intensity curves) and elimination (by linear regression analysis) revealed no dose-related differences. This study demonstrated a dose-dependent level of increased Doppler mean intensity within the brain circulation during infusion of SonoVue. Unlike the bell-shaped course of Doppler signal enhancement seen after bolus injection, infusion generates a stable plateau, which is an important prerequisite for more advanced contrast applications.

Analysis of Variance↗

On-line and off-line monitoring of the production of cephalosporin C by Acremonium chrysogenum.

Process monitoring of cephalosporin C formation by Acremonium chrysogenum in laboratory investigations is considered. The goal of these investigations is the identification of bottlenecks in the biosynthesis and the improvement of the process performance. Based on reports of other research groups and own experience the key parameters were selected, which influence the process performance. They are: dissolved oxygen and pH values. In addition the concentrations of biomass, DNA, glucose and reducing sugars (glucose, maltose, maltotriose and oligosaccharides), methionine, other nitrogen sources (ammonium ion, other amino acids), organic acids, phosphate, sulfate, dissolved organic carbon, proteins, product and precursors in the cell free cultivation medium are monitored. In addition the intracellular concentrations of RNA, DNA, proteins, amino acids as well as the activities of the enzymes of the biosynthesis of cephalosporin C are determined. The influence of these parameters on the biosynthesis is discussed.

Acremonium↗

Experiences of breastfeeding and vulnerability among a group of HIV-positive women in Durban, South Africa.

While international guidelines are currently being drawn up about HIV and infant feeding practices, and national and regional guidelines are under discussion in South Africa, there have been remarkably few studies that have sought to elicit HIV-positive mothers' experiences of breastfeeding and of paediatric infection. There is an urgent need to document this 'grass roots' knowledge in different sites, and for this data to be used to inform policy development, and for advocacy and counselling purposes. This qualitative investigation reports on the experiences and decisions taken around breastfeeding by a peer support group of 13 HIV-positive mothers meeting at King Edward VIII Hospital, Durban. In this study, the particular focus of information-giving and decision-making as to breast or formula feed is concerned with the impact on individual HIV-positive women and their babies. The most significant finding is that at no stage during their pregnancy were any of these mothers given information about the risks of HIV transmission through breastmilk. The study data were elicited in an in-depth group discussion, and individual women were invited to re-enact their stories in a follow-up discussion for clarification purposes. The women also discussed how they dealt with problems surrounding confidentiality in cases where few have been able to disclose their status to the extended family. There have been renewed calls for further investment in counsellors, with an enhanced role for community activists as peer educators. While there are severe resource constraints and low morale among many overworked nurses, one of the general problems in hospital settings remains the vertical health paradigm. This does not accommodate women's experiences, preferences, social networks and lay knowledge, and inhibits many women from becoming full participants in decisions affecting their own and their family's health.

Adult↗

Transcranial harmonic power duplex sonography for the evaluation of cerebral arteries.

Harmonic power-based duplex sonography is a new ultrasound method that improves the signal-to-noise ratio of extracranial vascular imaging. The authors evaluated this new method for transtemporal imaging of the basal cerebral arteries. Fundamental power-based duplex sonography (p-TCCS) and harmonic power-based duplex sonography (HI-p-TCCS) in combination with a novel perfluoropropane-containing ultrasound contrast agent (Optison) were investigated for the evaluation of the basal cerebral arteries in 12 healthy volunteers. The number of identified vascular segments and the blood flow velocities in the middle and posterior cerebral arteries were determined for p-TCCS and for two doses of Optison (0.5 and 1.5 mL) using HI-p-TCCS. Furthermore, the authors determined the time course of signal enhancement after Optison bolus injections. The results were compared using Friedman two-way ANOVA test. Significantly more arterial segments were visualized using HI-p-TCCS with enhancement of either 0.5 mL or 1.5 mL Optison (p < 0.01, each) than using p-TCCS. The spatial resolution was markedly increased with HI-p-TCCS, resulting in a striking difference in the detection of distal arterial segments and cortical and parenchymal branches. Except for the diastolic blood flow velocities (BFVs) in the M1 segment, the BFVs did not differ significantly between p-TCCS and HI-p-TCCS. Comparing HI-p-TCCS with 0.5 mL and 1.5 mL Optison, the authors found a small but significant reduction of the latency period (18.2 vs. 15.9 seconds, respectively; p < 0.01), a significant increase of the blooming phase (62.7 vs. 99.8 seconds, respectively; p < 0.0006) and a significant prolongation of the diagnostically useful signal enhancement (233.7 vs. 427.6 seconds, respectively; p < 0.004).

Adult↗

Harmonic imaging of the human brain. Visualization of brain perfusion with ultrasound.

BACKGROUND AND PURPOSE: Through harmonic gray-scale imaging, it is possible to analyze brain tissue perfusion with different ultrasound methods. METHODS: In 12 healthy volunteers, 2 doses (0.5 and 1.5 mL) of Optison, a perfluoropropane-containing contrast agent, were injected intravenously and produced a strong increase of brightness in the brain parenchyma. We used harmonic imaging for quantification of ultrasound intensity in the thalamus, ipsilateral temporoparietal white matter (TPWM), and ipsilateral lateral fissure at both sides. Time-intensity curves were calculated, and peak increase (PI) of intensity and the area under the time-intensity curve (AUC) from baseline were compared. RESULTS: We found a significant dose dependence of the AUC in all regions at both sides. PI only showed a significant dose dependence in the TPWM but not in the ipsilateral thalamus and lateral fissure. No side differences for AUC and PI were detected in all regions and doses used. We found a significantly higher value of the PI insonating the thalamus from the ipsilateral side compared with the contralateral side. The same result was obtained for the AUC in the left thalamus for both doses and in the right thalamus for the high dose. Using 0.5 mL for insonation of the right thalamus AUC again showed a higher value for the insonation from the ipsilateral compared with the contralateral side but failed to show statistical significance (P=0.08, n=12). CONCLUSIONS: Harmonic gray-scale imaging with Optison showed a strong enhancement effect in the brain parenchyma. A quantitative analysis of perfusion seems difficult because of the depth dependence of the effect. The most robust parameter is the AUC.

Brain↗

DIAS I: duplex-sonographic assessment of the cerebrovascular status in acute stroke. A useful tool for future stroke trials.

BACKGROUND AND PURPOSE: A number of controlled trials have evaluated the benefit of intravenous thrombolysis in acute stroke with inconsistent results. None of these studies assessed the initial vascular status or provided information regarding the recanalization rate after therapy. Further trials need to clarify whether certain subgroups might possibly benefit more than others from intravenous thrombolysis. Therefore, a fast and valid method for assessment of cerebrovascular status is needed. In this multicenter study, we evaluated the potentials and limitations of color-coded duplex sonography (TCCS) for cerebrovascular status assessment in acute stroke patients before and after therapy. Furthermore, we compared the recanalization rate for patients referred to thrombolytic and conservative medical therapy. METHODS: Fifty-eight patients suffering from hemispheric stroke were enrolled consecutively in 8 centers. Duplex sonography was performed on admission, 2 hours after start of therapy, and 24 hours after onset of symptoms. Therapy was started within 6 hours. RESULTS: Intravenous thrombolysis was performed in 18 patients, conservative medical therapy in 39 patients, and early thromboendarterectomy in 1 patient. The middle cerebral artery (MCA) mainstem was patent in 29 patients (53.7%), occluded in 25 (46.3%), and was not assessable in 4 patients. Recanalization of the occluded MCA after 2 and 24 hours was diagnosed in 50% and 78% of the patients treated with rtPA and in 0% and 8% in the conservatively treated patients. CONCLUSIONS: Intravenous thrombolysis is highly effective in restoring blood flow after MCA occlusion. TCCS is suitable for assessment of the cerebrovascular status in acute stroke and therefore might define therapeutically relevant subgroups of patients in future stroke trials on the basis of their vascular pathology.

Adult↗

Ultrasound perfusion imaging of the human brain.

BACKGROUND AND PURPOSE: Color-coded perfusion maps can be calculated from ultrasound harmonic gray-scale imaging data to analyze brain tissue perfusion. METHODS: In 13 healthy volunteers, 2 doses (0.5 and 1.5 mL) of Optison, a perfluoropropane-containing ultrasound contrast agent, were injected intravenously, and they produced a strong increase in echo enhancement in the brain parenchyma. The contrast agent was injected twice for ultrasound examination of both hemispheres. A total of 24 hemispheres per dose was available for further analysis. We used harmonic imaging for quantification of echo enhancement. Color-coded perfusion maps were calculated from the ultrasound data. In 1 subject, magnetic resonance images were obtained parallel to the orientation of the ultrasound scans. RESULTS: After administration of both doses of Optison, it was possible to evaluate brain tissue perfusion in all 24 hemispheres. Subtraction of precontrast images and color coding enhanced the visualization of hemispheric perfusion. The epiphyseal gland, anterior interhemispheric fissure, third ventricle, and lateral fissure can be used as reliable anatomic landmarks. Artifacts caused by abrupt changes in thickness of the temporal bone are observed as signal-void streaks oriented from the ultrasound probe toward the cerebral midline. CONCLUSIONS: Harmonic gray-scale imaging with Optison shows strong echo enhancement in the brain parenchyma. By calculating color-coded perfusion maps, it is possible to visualize human brain tissue perfusion at the patient's bedside.

Adult↗

Visualization of brain perfusion with harmonic gray scale and power doppler technology : an animal pilot study.

BACKGROUND AND PURPOSE: It is unclear which harmonic imaging mode (power Doppler or gray-scale imaging) is superior and which measuring method is the most robust for the description of brain perfusion. METHODS: We performed an animal study on 6 beagles through the intact skull using a SONOS 5500 device and Optison injected intravenously in 3 different doses (0.15, 0.3, and 0.6 mL). Intensity versus heart-cycle plots for the brain parenchyma and the basal cerebral arteries were generated to evaluate the peak increase (PI) from baseline and the area under the curve (AUC). RESULTS: With harmonic gray-scale imaging, a homogeneous increase in echo contrast of the brain parenchyma was observed. The effect was dose dependent, resulting in a significant increase in PI as well as an insignificant increase of the AUC with 0.3 mL versus 0.15 mL contrast agent (P=0.03 and P=0.65, respectively; n=5). With harmonic power Doppler, injection of the 3 different doses resulted in a nonsignificant increase in PI and AUC P=0.17, n=6 for both). After normalization of the brain signal to the peak arterial signal in individual dogs, a significant increase could be demonstrated (P=0. 03 and P=0.01, respectively; n=6). The signal pattern of harmonic power Doppler was inhomogeneous, with stronger signal increases in the anterior part of the brain. CONCLUSIONS: Gray-scale imaging leads to a more homogeneous increase in echo contrast of the brain tissue and may be more suitable for displaying brain perfusion. The PI of the signal intensity seems the most robust parameter for the description of cerebral perfusion with both imaging modes under investigation.

Acute Disease↗

Contrast-enhanced transcranial color-coded duplex sonography: efficiency and validity.

OBJECTIVE: To evaluate the diagnostic efficiency and accuracy of contrast-enhanced transcranial color-coded sonography (CE-TCCS). BACKGROUND: TCCS is hampered by insufficient ultrasonic penetration in 20% of cerebrovascular patients. METHODS: In 47 patients whose basal arteries could not be assessed adequately, 59 TCCS examinations were performed before and after administration of the ultrasonic contrast agent (CA) Levovist. The assessability of different basal cerebral arteries after CA administration was evaluated off-line. Angiographic records were available from 11 patients. RESULTS: Satisfactory investigation of the middle cerebral artery, the anterior cerebral artery, the P1 and P2 segments of the posterior cerebral artery, and the supraclinoid portion of the internal carotid artery siphon was possible in 5.1%, 28.8%, 35.6%, 55.9%, and 47.5% of patients before, and in 84.7%, 91.5%, 93.2%, 94.5%, and 93.2% of patients after contrast enhancement. Stenoses or occlusions of basal cerebral arteries were registered in 28 patients (60%). CE-TCCS diagnosis was confirmed by digital subtraction angiography or magnetic resonance angiography in 10 of the 11 patients, leading to positive and negative predictive values of 0.86 and 1.00. CONCLUSION: Contrast enhancement improves the diagnostic potential of TCCS significantly in patients with temporal bone window failure, and proved to be a reliable method for detecting middle cerebral artery and siphon occlusion.

Adult↗

The structure of human parathyroid hormone-related protein(1-34) in near-physiological solution.

Parathyroid hormone-related protein plays a major role in the pathogenesis of humoral hypercalcemia of malignancy. Under normal physiological conditions, parathyroid hormone-related protein is produced in a wide variety of tissues and acts in an autocrine or paracrine fashion. Parathyroid hormone-related protein and parathyroid hormone bind to and activate the same G-protein-coupled receptor. Here we present the structure of the biologically active NH2-terminal domain of human parathyroid hormone-related protein(1-34) in near-physiological solution in the absence of crowding reagents as determined by two-dimensional proton magnetic resonance spectroscopy. An improved strategy for structure calculation revealed the presence of two helices, His-5-Leu-8 and Gln-16-Leu-27, connected by a flexible linker. The parathyroid hormone-related protein(1-34) structure and the structure of human parathyroid hormone(1-37) as well as human parathyroid hormone(1-34) are highly similar, except for the well defined turn, His-14-Ser-17, present in parathyroid hormone. Thus, the similarity of the binding affinities of parathyroid hormone and parathyroid hormone-related protein to their common receptor may be based on their structural similarity.

Amino Acid Sequence↗

Sonographic monitoring of midline shift in hemispheric infarctions.

BACKGROUND AND OBJECTIVE: Transcranial color-coded sonography (TS) allows a noninvasive, accurate evaluation of lateral displacement of the third ventricle. The authors studied the prognostic value of TS monitoring of the midline shift (MLS) in acute hemispheric stroke. METHOD: Sixteen patients with acute middle cerebral artery (MCA) occlusion were investigated. On admission, the median modified Scandinavian Stroke Scale (mSSS) score was 6.0 (range, 5 to 8). Five patients died from cerebral herniation (group 1), 10 survived (group 2), and 1 patient (Patient 16) survived after decompressive surgery. TS was performed on days 1 to 4 (10 +/- 3, 32 +/- 4, 57 +/- 5, and 82 +/- 5 hours after onset of symptoms). Distance from the TS probe to the center of the third ventricle was measured both from the symptomatic (A) and asymptomatic (B) sides. MLS was calculated using the formula MLS = (A - B)/2. RESULTS: Ten hours after stroke onset, MLS and mSSS scores were not significantly different between the two groups. At 32, 57, and 82 hours, MLS was higher in group 1 (32 hours, p = 0.001; 57 hours, p = 0.003; 82 hours, p = 0.023) whereas there was no difference in mSSS score after 32 hours. All patients with an MLS < 4 mm at 32 hours survived, whereas patients with an MLS > 4 mm died as a result of cerebral herniation, with the exception of the one patient who underwent decompressive hemicraniectomy. CONCLUSIONS: The study of MLS at 32 hours after stroke onset in patients with severe MCA infarctions may identify patients who are unlikely to survive. The value of MLS in determining the indication of decompressive craniectomy merits further study.

Adult↗

The influence of Doppler system settings on the clearance kinetics of different ultrasound contrast agents.

OBJECTIVE: To evaluate the influence of different Doppler system settings on time-intensity curves after ultrasound contrast agent (UCA) bolus injection. This is important for the comparison of different UCAs. METHODS: Six sedated dogs were investigated with a transcranial Doppler system and Doppler power, sample volume size and high pass filter settings were modified during the procedure. Mean time intensity curves were determined and peak values of mean intensity as well as the decrease in Doppler intensity were compared for the different system settings. Three different UCAs were used (SonoVue(TM), BY963 and Levovist(TM)). RESULTS: The Doppler time intensity curves showed a typical two phase decrease with a distribution phase alpha and an elimination phase beta with all three UCAs. Altering the system settings had a significant effect on the mean peak Doppler intensity for SonoVue(TM) (P=0.02) but not for BY963 or Levovist(TM) (P=0.07 and P=0.39, respectively), due to high variation of the Levovist(TM) and BY963 intensity values. There were no significant differences between the alpha slopes of BY963 and Levovist(TM) (P=0.96), or the beta slope of Levovist(TM) and SonoVue(TM) (P=0.62), when the results of all system settings were combined. CONCLUSION: Different Doppler system settings show no significant influence on the decrease of mean Doppler intensity, but have a significant effect on peak intensity.

Analysis of Variance↗

Safety and ultrasound-enhancing potentials of a new sulfur hexafluoride-containing agent in the cerebral circulation.

Insufficient ultrasound penetration through the temporal bone is a serious limitation of transcranial ultrasound diagnostics. In a phase I study, the authors studied safety and ultrasound enhancing potentials of the new transpulmonary ultrasound contrast agent SonoVue, which contains sulfur hexafluoride gas microbubbles stabilized by a phospholipid shell. Twelve healthy volunteers received four different doses of SonoVue (0.3 ml, 0.6 ml, 1.2 ml, and 2.4 ml) intravenously. The duration of ultrasound contrast enhancement was measured by transcranial Doppler sonography (TCD) and transcranial color-coded sonography (TCCS). Safety and tolerability was monitored during the study and for 24 hours after contrast agent administration. TCD: Duration of spectral enhancement (signal intensity of 5 dB over baseline) was observed dose-related (p < 0.0001; Friedman-test) for (0.3 ml) 136 +/- 63.4 seconds; (0.6 ml) 191 +/- 63.3 seconds; (1.2 ml) 314 +/- 88 seconds; (2.4 ml) 434 +/- 168 seconds [mean +/- SD]. Dependent on dosage, the peak signal amplification in TCD was significantly different (p < 0.001; Friedman-test) as well: (0.3 ml) 24.5 +/- 2.0 dB; (0.6 ml) 26.0 +/- 1.6 dB; (1.2 ml) 27.6 +/- 2.2 dB; (2.4 ml) 28.4 +/- 2.2 dB (mean +/- SD). TCCS: Mean time of optimal enhancement increased from 214 +/- 73 seconds (0.3 ml) to 356 +/- 14 seconds (2.4 ml) in a dose-dependent manner. In TCCS, signal amplification appeared to be stronger with increasing doses. Adverse events were not observed during the study. This investigation describes the ultrasound enhancing potential of SonoVue in the intracranial cerebral circulation. SonoVue proved to be well tolerated and provided a long-lasting ultrasound contrast enhancement that supports an optimal transcranial ultrasound diagnostic.

Adult↗

Harmonic grey scale imaging of the human brain.

Harmonic imaging increases the signal-to-noise ratio in grey-scale imaging. With the use of ultrasound contrast agents (UCA), imaging of brain perfusion seems possible. The authors used an ultrasound system in connection with a 1.8/3.6-MHz harmonic sector transducer and an acoustic densitometry unit for quantification of ultrasound intensity in the thalamus (THAL), the temporoparietal white matter (TPWM), and the lateral fissure (LF). Ten milliliters of BY963, a spherosome-air-based UCA, was injected intravenously in 12 healthy volunteers. Time-intensity curves were calculated. Mean increase of intensity (standard deviation [SD]), mean area under the time-intensity curve (AUC) from baseline (SD), and mean transit time (MTT) (SD) in the region of LF, THAL, and TPWM were 2.2 +/- 1.7, 1.1 +/- 0.6, 0.9 +/- 0.9 dB and 16.7 +/- 22.7, 4.7 +/- 4.7, 3.7 +/- 6.3 as well as 11.1 +/- 3.5, 9.7 +/- 3.1, and 11.9 +/- 8.0, respectively. There was a statistically significant difference for mean AUC (p = 0.02) but none comparing mean intensity increase (p = 0.07) and MTT (p = 0.9). The authors' study indicates that different regions of the human brain show different time-intensity curves. These results suggest that it is possible to measure parameters closely related to perfusion in various regions of the adult human brain.

Adult↗

Comparison of transcranial color-coded duplex sonography and cranial CT measurements for determining third ventricle midline shift in space-occupying stroke.

BACKGROUND AND PURPOSE: Transcranial color-coded duplex sonography (TCCS) allows the noninvasive, easily reproducible measurement of midline dislocation (MLD) of the third ventricle in space-occupying stroke, even in critically ill patients. However, the method has been validated only in a small number of subjects. The aim of this study was to test the method under clinical conditions. METHODS: In 61 prospectively recruited patients (mean age, 62+/-15 years) with supratentorial ischemic infarction or intracranial hemorrhage, the sonographic measurement of MLD was compared with cranial CT data in a 12-hour time window. Subgroup analysis was also undertaken for comparing TCCS and cranial CT measurements within a 3-hour time window. RESULTS: One hundred twenty-two data pairs of TCCS and cranial CT MLD measurements were correlated within the 12-hour time window. TCCS and cranial CT measurements of MLD correlated both in the total patient group and in the different subgroups with coefficients of over 0.9. The 2-SD confidence interval of the difference between the TCCS measurements and the respective means of both methods in the total patient collective was +/-1.78 mm. CONCLUSION: TCCS provides a noninvasive, easily reproducible and reliable method for monitoring MLD of the third ventricle in stroke patients. It is particularly suitable for critically ill patients who are not fit for transportation.

Adult↗