G S Wilson

Publications and source records attributed to G S Wilson.

At least 55 records · Page 3Linked to original sources

Iron-thiolate induced oxidation of methionine to methionine sulfoxide in small model peptides. Intramolecular catalysis by histidine.

Peptides containing either glycine and methionine, or glycine, methionine and histidine at various locations were oxidized by the dithiothreitol/ferric chloride system in phosphate buffer. The yields of peptide degradation and sulfoxide formation were measured as a function of peptide sequence and pH. In general little change of the final yields of peptide degradation is observed whereas the final yields of sulfoxide formation progressively decrease on going from pH 6.0 to 8.0. The pH profiles vary with the structure of the respective peptide. Efficient sulfoxide formation occurred when histidine and methionine were present within the same peptides sequence, and particularly when methionine was located at the C-terminus of the peptide. Added superoxide dismutase, catalase, and methanol did neither promote nor inhibit both the degradation of peptide and the formation of sulfoxide excluding free superoxide, hydrogen peroxide, and hydroxyl radicals as responsible reactive oxygen species. The observations are rationalized by invoking a pH-dependent conversion of an efficiently sulfoxide yielding oxidant into another oxidant which still degrades peptides but does not form methionine sulfoxide. The first might be a metal-bound peroxide or peroxyl species which converts into a metal-bound or 'complexed' hydroxyl radical.

Amino Acid Sequence↗

Noncompetitive flow injection immunoassay for a hapten, alpha-(difluoromethyl)ornithine.

A noncompetitive flow injection immunoassay method has been developed to assay small haptens. In this assay the sample containing the hapten is incubated with excess enzyme-labeled monovalent antibody for a brief period. The excess antibody is then separated from the bound antibody by eluting through an antigen-immobilized immunoaffinity column. The enzyme label of the eluting antibody-hapten complex is fluorometrically detected. The applicability of the method is demonstrated by assaying alpha-(difluoromethyl)ornithine (DFMO), an anticancer drug in human plasma samples. The assay is sensitive enough to detect 200 amol of DFMO. Interferences from other similar endogenous amines have been eliminated by selective immunoaffinity purification of the antibodies.

Animals↗

A glucose monitoring system for on line estimation in man of blood glucose concentration using a miniaturized glucose sensor implanted in the subcutaneous tissue and a wearable control unit.

We have developed a miniaturized glucose sensor which has been shown previously to function adequately when implanted in the subcutaneous tissue of rats and dogs. Following a glucose load, the sensor output increases, making it possible to calculate a sensitivity coefficient to glucose in vivo, and an extrapolated background current in the absence of glucose. These parameters are used for estimating at any time the apparent subcutaneous glucose concentration from the current. In the previous studies, this calibration was performed a posteriori, on the basis of the retrospective analysis of the changes in blood glucose and in the current generated by the sensor. However, for clinical application of the system, an on line estimation of glucose concentration would be necessary. Thus, this study was undertaken in order to assess the possibility of calibrating the sensor in real time, using a novel calibration procedure and a monitoring unit which was specifically designed for this purpose. This electronic device is able to measure, to filter and to store the current. During an oral glucose challenge, when a stable current is reached, it is possible to feed the unit with two different values of blood glucose and their corresponding times. The unit calculates the in vivo parameters, transforms every single value of current into an estimation of the glucose concentration, and then displays this estimation. In this study, 11 sensors were investigated of which two did not respond to glucose. In the other nine trials, the volunteers were asked to record every 30 s what appeared on the display during the secondary decrease in blood glucose.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Chemical pathways of peptide degradation. V. Ascorbic acid promotes rather than inhibits the oxidation of methionine to methionine sulfoxide in small model peptides.

The effect of primary structure and external conditions on the oxidation of methionine to methionine sulfoxide by the ascorbate/Fe3+ system was studied in small model peptides. Degradation kinetics and yield of sulfoxide formation were dependent on the concentration of ascorbate and H+, with a maximum rate observed at pH 6-7. Phosphate buffer significantly accelerated the peptide degradation compared to Tris, HEPES, and MOPS buffers; however, the formation of sulfoxide was low. The oxidation could not be inhibited by the addition of EDTA. Other side products besides sulfoxide were observed, indicating the existence of various other pathways. The influence of methionine location at the C terminus, at the N terminus, and in the middle of the sequence was investigated. The presence of histidine in the sequence markedly increased the degradation rate as well as the sulfoxide production. The histidine catalysis of methionine oxidation occurred intramolecularly with a maximum enhancement of the oxidation rate and sulfoxide production when one residue was placed between the histidine and the methionine residue.

Amino Acid Sequence↗

Studies of the low dose 'hook' effect in a competitive homogeneous immunoassay.

The interactions of two monoclonal antibodies with human growth hormone (hGH) have been investigated. The individual antibodies showed normal behavior in a competitive binding assay, but mixtures of the antibodies demonstrated a 'hook' attributable to cooperative interactions. Cooperativity was observed in titrations which preceded the competitive binding assay. Size exclusion chromatographic data suggest that the cooperativity is explained by the formation of higher molecular weight complexes (up to 700 kDa). The major complex is probably linear, consisting of three antibody molecules. Circular and linear complexes with four antibody molecules (octameric complexes) are also possible. Theoretical models also support the formation of cyclic complexes in a competitive binding assay.

Allosteric Regulation↗

Studies of the 'hook' effect in the one-step sandwich immunoassay.

The one-step sandwich immunoassay is increasingly replacing the traditional two-step immunoassay due to obvious advantages such as assay speed. However, the one-step sandwich immunoassay suffers from the 'hook' effect irrespective of the analyte characteristics. The 'hook' effect is dependent primarily on the analyte concentration. Three different model analytes, human growth hormone (hGH), the dimeric form of hGH (D-hGH, having a discrete number of repeating epitopes) and ferritin (multiple epitopes) having different immunological properties have been employed in studies of the one-step sandwich immunoassay. The characteristics of each of the model analytes offer new insights into general guidelines for assay procedures. These guidelines permit rapid optimization of assay conditions for an immunoassay without a priori knowledge of the immunological characteristics of the antibody or antigen. Both experimental and theoretical data show several instances where high capacity solid-phase antibodies can effectively shift the 'hook' to relatively higher analyte concentrations. The effect of the concentration of labeled antibody on assay response was examined theoretically.

Antigen-Antibody Reactions↗

Multiple epitope interactions in the two-step sandwich immunoassay.

The 'hook' effect as related to the two-step sandwich immunoassay has been investigated experimentally and theoretically. The multiple epitope interactions between the analyte and the labeled antibody cause a 'hook' in the two-step sandwich immunoassay. Three different analytes and monoclonal antibodies were chosen to carefully demonstrate the effect of the analyte characteristics on this immunoassay. Two monoclonal antibodies against two different epitopes of biosynthetic human growth hormone (hGH) was the simplest model for this study. The sandwich immunoassay for hGH shows no 'hook' effect. The non-covalent dimeric form of hGH (D-hGH) possesses two repeating epitopes which is the simplest model for an analyte having a discrete number of repeating epitopes. The D-hGH assay demonstrated a 'hook' effect in the two-step sandwich immunoassay if the labeled antibody was allowed to interact with more than one epitope. In a third system multiple epitope interactions with the labeled antibody were observed using ferritin. The effect of the analyte concentration and the liquid-phase antibody have been examined to elucidate the nature of these various interactions. The cause of the 'hook' effect in the two-step sandwich immunoassay is attributed to the desorption of the bound analyte due to a conformational change after the labeled antibody interacts with several epitopes of the adsorbed analyte.

Antibodies, Monoclonal↗

Can continuous glucose monitoring be used for the treatment of diabetes.

In the case of the glucose sensor, clinicians and chemists must cooperate in interdisciplinary research to carefully define the analytical problem. Although not specifically discussed in this article, another group that must participate in this effort is engineers. Their expertise is needed to design the monitoring and control unit that contains the alarm and pump systems. The glucose sensor must operate reliably in an in vivo environment, provide the clinical information needed, and be easy to operate and manufacture.

Animals↗

Towards continuous glucose monitoring: in vivo evaluation of a miniaturized glucose sensor implanted for several days in rat subcutaneous tissue.

A miniaturized amperometric, enzymatic, glucose sensor (outer diameter 0.45 mm) was evaluated after implantation in the subcutaneous tissue of normal rats. A simple experimental procedure was designed for the long-term assessment of the sensor's function which was performed by recording the current during an intraperitoneal glucose load. The sensor was calibrated by accounting for the increase in the current during the concomitant increase in plasma glucose concentration, determined in blood sampled at the tail vein. This made it possible to estimate the glucose concentration in subcutaneous tissue. During the glucose load, the change in subcutaneous glucose concentration followed that in blood with a lag time consistently shorter than 5 min. The estimations of subcutaneous glucose concentration during these tests were compared to the concomitant plasma glucose concentrations by using a grid analysis. Three days after implantation (n = 6 experiments), 79 estimations were considered accurate, except for five which were in the acceptable zone. Ten days after implantation (n = 5 experiments), 101 estimations were accurate, except for one value, which was still acceptable. The sensitivity was around 0.5 nA.mmol-1.l-1 on day 3 and day 10. A longitudinal study on seven sensors tested on different days demonstrated a relative stability of the sensor's sensitivity. Finally, histological examination of the zone around the implantation site revealed a fibrotic reaction containing neocapillaries, which could explain the fast response of the sensor to glucose observed in vivo, even on day 10. We conclude that this miniaturized glucose sensor, whose size makes it easily implanted, works for at least ten days after implantation into rat subcutaneous tissue.

Animals↗

Progress toward the development of an implantable sensor for glucose.

The development of an electrochemically based implantable sensor for glucose is described. The sensor is needle-shaped, about the size of a 28-gauge needle. It is flexible and must be implanted subcutaneously by using a 21-gauge catheter, which is then removed. When combined with a monitoring unit, this device, based on the glucose oxidase-catalyzed oxidation of glucose, reliably monitors glucose concentrations for as long as 10 days in rats. Various design considerations, including the decision to monitor the hydrogen peroxide produced in the enzymatic reaction, are discussed. Glucose constitutes the most important future target analyte for continuous monitoring, but the basic methodology developed for glucose could be applied to several other analytes such as lactate or ascorbate. The success in implementation of such a device depends on a reaction of the tissue surrounding the implant so as not to interfere with the proper functioning of the sensor. Histochemical evidence indicates that the tissue response leads to enhanced sensor performance.

Biocompatible Materials↗

Factors affecting the specific activity of immobilized antibodies and their biologically active fragments.

Factors affecting the specific activity of immobilized antibodies and their biologically active fragments were studied with goat anti-mouse and goat anti-human immunoglobulin G. Antibodies were immobilized on HW 65 polymeric support matrix activated with carbonyldiimidazole, hydrazide and iodoacetic acid. The most significant factors influencing the specific activity of stochastic coupling of antibodies are multi-site attachment, multiple orientations and steric hindrance imposed by crowding of antibody and the size of the antigen. In oriented immobilization the specific activity is affected only by steric hindrance. The specific activity of immunosorbents prepared by immobilization of F(ab') fragments can be improved to almost 100% by limiting the amount of protein immobilization and the size of the antigen. The present study shows the protocols for optimizing immobilized antibody performance.

Adipates↗

Design and in vitro studies of a needle-type glucose sensor for subcutaneous monitoring.

A new miniaturized glucose oxidase based needle-type glucose microsensor has been developed for subcutaneous glucose monitoring. The sensor is equivalent in shape and size to a 26-guage needle (0.45-mm o.d.) and can be implanted with ease without any incision. The novel configuration greatly facilitates the deposition of enzyme and polymer films so that sensors with characteristics suitable for in vivo use (upper limit of linear range greater than 15 mM, response time less than 5 min, and sensitivity yielding a 5:1 signal-to-background ratio at normal basal glucose levels) can be prepared in high yield (greater than 60%). The sensor response is largely independent of oxygen tension in the normal physiological range. It also exhibits good selectivity against common interferences except for the exogenous drug acetaminophen.

Animals↗

Application of cell culture toxicity tests to the development of implantable biosensors.

Cell culture toxicity testing methods were modified and applied to the development of implantable glucose microsensors, and positive and negative control materials suitable for the microsensor assessment were established. The location, source and degree of the toxic effect in a multi-component biosensor was spatially visualized with cell monolayers. A freshly prepared sensor showed moderate toxicity, mainly as a result of the presence of glutaraldehyde and the residual solvents in the polymer layers. However, it was possible to reduce the toxicity by removing the leachable toxic substances through extraction in phosphate buffer, and a non-toxic sensor was readily obtained.

Agar↗

Children of battered women: developmental and learning profiles.

Children in battered women's shelters have been shown to have more behavior problems than their peers but limited information is available about their development. A pilot survey was undertaken to determine the prevalence of developmental or academic problems in children of residents of a battered women's shelter. Demographic data, medical and school histories and responses to standardized developmental or behavioral surveys were obtained from 39 mothers of 76 children. Two-thirds of the children were victims of abuse. On the Minnesota Child Development Inventory, the mean General Developmental Quotient (DQ) of 28 preschool children was 98; however, 39% had developmental delays by test criteria. Of 46 school-aged children, 21 (46%) had evidence of academic problems, including grade repetition, failing grades and need for special educational services. On the Louisville Behavior Checklist, 75% of 48 children had behavior problems. Children in a battered women's shelter are likely to experience academic and behavioral problems; however, further study is needed to elucidate etiological factors.

Adolescent↗

Patterns of growth and development in narcotic-exposed children.

The results of the studies reviewed indicate that intrauterine growth is adversely affected by drug use during pregnancy. Whether the impairment is a direct effect of narcotic exposure or is the result of the interaction of deleterious health, environmental, and socioeconomic factors closely associated with the lifestyle of the woman who abuses drugs cannot be determined at present. Reports on the long-term effects of drug use on growth and intellectual functioning in the offspring of women who abuse drugs are not consistent. While some studies indicate that most of the exposed infants exhibit catchup growth by 6 months of age (Lifschitz et al. 1983, 1985), one methodologically strong study suggests that methadone may have a small direct teratogenic effect reflected in reduced head size at 2 years of age (Hans 1989). Unexplained is the pattern of growth deceleration observed in some narcotic-exposed children (Lifschitz et al. 1983, 1985). The few available reports on long-term outcome concur that narcotic-exposed children have a high incidence of behavioral and learning problems (Strauss et al. 1979; Rosen and Johnson 1985; Wilson 1989), but population studies have been too small to demonstrate that they differ significantly from controls. There is a suggestion that narcotic use during pregnancy promotes a biological vulnerability to adverse environments, manifested in the neurobehavioral and intellectual areas.

Child↗

Optimization of multienzyme flow reactors for determination of acetylcholine.

Immobilized enzyme reactors have been used with high-performance liquid chromatography (HPLC) and electrochemical detection to detect acetylcholine and choline in brain tissue samples. Acetylcholine and choline eluting from the LC column are introduced into a reactor containing immobilized acetylcholinesterase, which hydrolyzes acetylcholine to choline. The product is converted by a second enzyme, choline oxidase, to hydrogen peroxide, which is determined amperometrically. Several novel immobilization techniques including immobilization through enzyme-specific antibodies were used to immobilize these enzymes to retain maximum activity. Improved detection limits were observed when the enzymes were immobilized through the avidin-biotin linkage. Better sensitivity and detection limit were obtained when both enzymes were immobilized together on the same support through the avidin-biotin linkage than when they were separately immobilized and used in two columns. The postcolumn system was applied to brain tissue extracts.

Acetylcholine↗

Improved methods for separation of human cytokeratins.

The cytokeratins from human bladder and esophageal epithelia were separated using chromatographic techniques. The cytokeratins were first extracted from fresh autopsy tissue using high and low salt buffers. Urea, 8.0-9.5 M, was used to solubilize the resulting cytokeratin pellet. Imidazole was found to increase the solubility of the pellet but reducing agents such as 2-mercaptoethanol were not beneficial. DEAE ion exchange chromatography produced three fractions which were analyzed by using one and two-dimensional electrophoresis. The third fraction was shown to contain the acidic cytokeratins and was further fractionated on a moderately polar reverse phase HPLC column using an acetonitrile elution gradient. Tetramethylammonium tetrafluoroborate was added to the mobile phase to react with any unreacted silanol groups on the stationary phase, and trifluoroacetic acid was added to ion pair with the protein. HPLC fractions of the acidic proteins from human esophagus revealed seven reproducible peaks. All seven peaks were shown by Western blotting to contain an epitope found on cytokeratin 13. The results suggest that the isolation and separation procedures have produced a series of peptide products which all retain a similar epitope but which vary significantly in their hydrophobic characteristics.

Chromatography, High Pressure Liquid↗