Continuous glucose monitoring in the free-moving rat.

The aim of this work was to set up an experimental model of glycemic fluctuations for assessing in the conscious freely moving rat, the performance of a continuous glucose-monitoring system, using a pocket-calculator-size electronic control unit and a miniaturized subcutaneous glucose sensor. The well-known triphasic glycemic pattern following streptozotocin injection (initial peak and secondary hypoglycemia preceding the establishment of permanent hyperglycemia) was used as a way to obtain spontaneous changes in blood glucose level over a wide concentration range. This report demonstrates that streptozotocin injection produced highly reproducible changes in the current generated by the sensor: an initial peak and a secondary nadir, during which blood sampling provided the evidence of hyperglycemia associated with immunoreactive hypoinsulinemia, and of hypoglycemia associated with hyperinsulinemia, respectively. This reproducible experimental model should be valuable for the assessment of a continuous glucose-monitoring system.

Animals↗

A user-friendly method for calibrating a subcutaneous glucose sensor-based hypoglycaemic alarm.

A crucial step in developing a glucose monitoring system using a subcutaneous implanted glucose sensor is the transformation of the sensor signal (a current) into an estimation of a blood glucose concentration. We have developed an Electronic Control Unit (ECU) able to recognize, before and after a glucose load, that the sensor current presents a plateau, thus triggering an alarm asking for blood glucose determination. The system, fed with these results, subsequently transforms the current into an estimation of glucose concentration by linear extrapolation based on the sensor sensitivity and the background current computed from the two sets of current and glycaemia values (two-point calibration). In addition, the system is able to trigger an alarm when this estimation decreases below a threshold that can be set by the user. This system was evaluated in experiments performed in 12 normal rats. The quality of the calibration was assessed by comparing, by error grid analysis, the data displayed on the liquid-crystal display of the ECU to concomitant plasma glucose concentration determined at frequent intervals, 65 +/- 6 and 26 +/- 5% of the values were in zones A (good) and B (acceptable estimation) of the grid, respectively. The system was set to trigger an alarm when the estimation of glucose concentration decreased below 70 mg/dl. Following an insulin administration, the alarm was triggered when the system displayed a 64 +/- 2 mg/dl glucose concentration. The concomitant plasma glucose concentration was 59 +/- 5 mg/dl (NS). In conclusion, this work validates experimentally the new, user-friendly method for calibrating the glucose sensor integrated into the ECU, based on an automatic detection of plateaus. The quality of the sensor calibration performed with this procedure is compatible with the appropriate functioning of this continuous glucose monitoring system, which was demonstrated by its ability to detect mild hypoglycaemia following insulin injection.

Animals↗

A novel high-dose chemotherapy protocol with autologous hematopoietic rescue in patients with metastatic breast cancer or recurrent non-Hodgkin's lymphoma.

In this phase II trial, we used a double dose-intensive chemotherapy and stem cell rescue protocol to treat breast cancer (BCA) patients or non-Hodgkin's lymphoma patients (NHL). The first cycle consisted of high-dose melphalan followed by ABMT. The second cycle used a novel chemotherapy combination; thiotepa, etoposide, carboplatin and cyclophosphamide (TECC) followed by ABMT. We treated 12 patients in total, nine with BCA, three with NHL. All nine BCA patients were treated with the two cycle protocol. The three NHL patients were treated with the second cycle only. Bone marrow (BM, 1 patient), peripheral blood stem cells (PBSC, 10 patients) or both (1 patient) were reinfused 60-72 h after completion of each cycle of chemotherapy. Recovery was rapid; the ANC rose to greater than 500/microl on day +11 (+8 to + 20) and the platelet count to greater than 20000/microl on day +12 (+6 to +20). The toxicities included the expected neutropenic fevers, severe mucositis, diarrhea, and a low incidence of mild renal insufficiency. No patients developed veno-occlusive disease, hemorrhagic cystitis or overt bleeding. With a mean follow-up of 37 months, 83.3% of the patients are alive. Six patients are in complete remission; one patient with BCA relapsed and expired; one patient with NHL is in CR now over 18 months after relapse and subsequent treatment with interferon; one patient is too early to evaluate. Progression-free survival overall is 75%, which is at least equivalent to many other recent studies using similar regimens. In addition, we have also found that delayed addition of G-CSF during the mobilization of PBSC was feasible and resulted in excellent CD34+ cell counts and engraftments, and reduced treatment costs. These results indicate that this chemotherapy is effective with good remission rates and high progression-free survival rates. It is also well tolerated with acceptable toxicities that are manageable. Long-term follow-up of a larger cohort of patients will be needed to ascertain the overall efficacy of this type of therapy.

Adult↗

Rapid changes in local extracellular rat brain glucose observed with an in vivo glucose sensor.

A needle-type electrochemically based microsensor for glucose (110 microns o.d.) is described. This sensor, designed for monitoring transient glucose content changes in response to neural stimuli, has a response time of approximately 5 s and has been shown to be free of interference from endogenous electroactive species such as ascorbate, urate, and various neurotransmitters. It exhibits linear response to glucose up to 10 mM. The usefulness of the sensor has been demonstrated by examining the time-dependent interstitial glucose concentration in the rat hippocampus in response to KCl depolarization and by stimulation of glutamate neurons through a perforant pathway. Simultaneous monitoring of oxygen is also carried out and demonstrates that for both oxygen and glucose there is substantial local depletion of both species and that their pools are replenished by increased regional cerebral blood flow. The transient initial rapid (10-13 s) decrease up to 20-34%, observed on a time scale comparable to that for neurotransmitter release, may be involved in a recently suggested astrocytic uptake for glutamate-stimulated aerobic glycolysis possibly needed to meet energy homeostasis in brain. These studies demonstrate the importance of microsensors in monitoring transient events linked to neuronal stimulation.

Animals↗

A temporary local energy pool coupled to neuronal activity: fluctuations of extracellular lactate levels in rat brain monitored with rapid-response enzyme-based sensor.

A successfully developed enzyme-based lactate microsensor with rapid response time allows the direct and continuous in vivo measurement of lactic acid concentration with high temporal resolution in brain extracellular fluid. The fluctuations coupled to neuronal activity in extracellular lactate concentration were explored in the dentate gyrus of the hippocampus of the rat brain after electrical stimulation of the perforant pathway. Extracellular glucose and oxygen levels were also detected simultaneously by coimplantation of a fast-response glucose sensor and an oxygen electrode, to provide novel information of trafficking of energy substances in real time related to local neuronal activity. The results first give a comprehensive picture of complementary energy supply and use of lactate and glucose in the intact brain tissue. In response to acute neuronal activation, the brain tissue shifts immediately to significant energy supply by lactate. A local temporary fuel "reservoir" is established behind the blood-brain barrier, evidenced by increased extracellular lactate concentration. The pool can be depleted rapidly, up to 28% in 10-12 s, by massive, acute neuronal use after stimulation and can be replenished in approximately 20 s. Glutamate-stimulated astrocytic glycolysis and the increase of regional blood flow may regulate the lactate concentration of the pool in different time scales to maintain local energy homeostasis.

Animals↗

Optimal and predicted anxiety in 9-12-year-old track and field athletes.

In an effort to determine the applicability of individual zone of optimal functioning (IZOF) theory in young athletes, state anxiety was assessed in 40 track and field athletes (20 male and 20 female) from 9 to 12 years of age. Optimal anxiety was determined by having participants complete the state-trait anxiety scale for children (STAIC) with instructions to recall how anxious they felt prior to their best performance of the season. Twenty-four hours prior to three 'more important' and three 'less important' track meets, participants completed the STAIC under instructions to predict how anxious they would feel 1 h prior to the upcoming track meet. Actual precompetition anxiety was assessed 1 h prior to each meet. Self-ratings of performance were collected following each meet in which the athletes competed. Athletes were grouped by age (younger, 9-10 years old); (older, 11-12 years old) and by gender for analysis. Analysis by independent t-tests indicated that predicted and actual precompetition anxiety values did not differ for either age or gender for the more important meets. However, the 11-12-year-old girls had higher (P<0.05) predicted and actual anxiety values in the 'less important' meets than all other groups. Significant correlations (P<0.05) between predicted and actual precompetition anxiety occurred in all groups for both the less important and more important meets (r=0.66-0.97), with the exception of the 9-10-year-old girls for less important meets (r=0.38, P>0.05). Of all the participants, 26% reported performing best when anxiety values were in the high range. Self-ratings of performance were not lower (P>0.05) in cases in which the athlete experienced high levels of precompetition anxiety. In summary, the present findings indicate that several aspects of IZOF theory apply to preadolescent athletes.

Age Factors↗

Use of a subcutaneous glucose sensor to detect decreases in glucose concentration prior to observation in blood.

The development of a hypoglycemic alarm system using a subcutaneous glucose sensor implies that a decrease in blood glucose is rapidly followed by a decrease in the signal generated by the sensor. In a first set of experiments the linearity and the kinetics of the response of sensors implanted in the subcutaneous tissue of normal rats were investigated during a progressive increase in plasma glucose concentration: the sensitivities determined between 5 and 10 mM and between 10 and 15 mM were not significantly different, and a 5-10 min delay in the sensor's response was observed. In a second set of experiments, performed in diabetic rats, the kinetics of the decrease in subcutaneous glucose concentration following insulin administration was monitored during a decrease in plasma glucose level, from 15 to 3 mmol/L. During the 20 first min following insulin administration, the sensor monitored glucose concentration in subcutaneous tissue with no lag time. Subsequently, the decrease in the estimation of subcutaneous glucose concentration preceded that of plasma glucose. This phenomenon was not observed when the same sensors were investigated in vitro during a similar decrease in glucose concentration and may be due to a mechanism occurring in vivo, such as the effect of insulin on glucose transfer from the interstitial space to the cells surrounding the sensor. It reinforces the interest of the use of implantable glucose sensors as a part of a hypoglycemic alarm.

Scintillation Counting↗

Polymeric mercaptosilane-modified platinum electrodes for elimination of interferants in glucose biosensors.

An oxidase-based glucose sensor has been developed that uses a mercaptosilane-modified platinum electrode to achieve selectivity of electrochemical interferants. A platinum-iridium (9:1) wire (0.178 mm o.d., sensing area of 1.12 mm2) is modified with (3-mercaptopropyl)trimethoxysilane. The modified sensors show excellent operational stability for more than 5 days. Glucose oxidase is immobilized on the modified surface (i) by using 3-maleimidopropionic acid as a linker or (ii) by cross-liking with bovine serum albumin using glutaraldehyde. Sensitivities in the range of 9.97 nA/mM glucose are observed when the enzyme is immobilized by method ii. Lower sensitivities (1.13 x 10(-1) nA/mM glucose) are observed when immobilization method i is employed. In terms of linear response range, the sensor enzyme-immobilized by method i is superior to that immobilized by method ii. The linearity is improved upon coating the enzyme layer with polyurethane. The sensor immobilized by method ii and coated with polyurethane exhibits a linear range to 15 mM glucose and excellent selectivity to glucose (0.47 nA/mM) against interferants such as ascorbic acid, uric acid, and acetaminophen.

Biosensing Techniques↗

Modification of the sensitivity of glucose sensor implanted into subcutaneous tissue.

The mechanism of reducing the glucose sensitivity of sensors implanted into the subcutaneous tissue of the normal rat was evaluated (n = 10) by comparing sensitivities observed in vitro and in vivo. In vivo sensitivity was significantly lower than that observed in vitro before implantation (p < 0.005). Most interestingly, in vitro sensitivity immediately after explanation did not differ from that in vivo and increased progressively during rinsing (p < 0.02 after 30 min). These results demonstrate that the reduction of in vivo sensitivity was not due to a local factor or factors but to a reversible alteration of the glucose sensor characteristics induced in vivo by some local factor(s). This suggests that modifications of the outer sensor membrane, the nature of which remains to be determined, may prevent this effect and resolve the problem.

Animals↗

Solid phase synthesis of bifunctional antibodies.

Bifunctional antibodies were prepared using the principle of solid-phase synthesis. The two Fab' fragments were chemically linked together via a bismaleimide crosslinking reagent. The F(ab')2 fragments from intact IgG were prepared using an immobilized pepsin column. Goat, mouse and human antibodies were digested completely within 4 h. The F(ab')2 fragments thus produced did not contain any IgG impurities. The Fab' fragments were produced by reducing the inter-heavy chain disulfide bonds using 2-mercaptoethylamine. The use of the solid-phase reactor in the preparation of the bifunctional antibodies eliminated many of the time-consuming separation steps between the fragmentation and conjugation steps. This procedure facilitates the automation of the bifunctional antibody preparation and the rapid optimization of reaction conditions.

Animals↗

Direct measurement of glutamate release in the brain using a dual enzyme-based electrochemical sensor.

The in vivo measurement of the rapid changes in the extracellular concentrations of L-glutamic acid in the mammalian brain during normal neuronal activity or following excessive release due to episodes of anoxia or ischemia has not been possible to this date. Current techniques for the measurement of the release of endogenous glutamate into the extracellular space of the central nervous system are relatively slow and do not measure the actual concentration of free glutamate in the extracellular space. An enzyme-based electrode with rapid response times (about 1 s) and high degree of sensitivity (less than 2 microM) and selectivity for L-glutamic acid is described in this paper. This electrode has both L-glutamate and ascorbate oxidase immobilized on its surface. The latter enzyme removes almost completely any interferences produced by the high levels of extracellular ascorbate present in brain tissue. The response of the electrode to glutamate and other potentially interfering substances was fully characterized in vitro and its selectivity, sensitivity and rapidity in responding to a rise in extracellular glutamate concentrations was also demonstrated in vivo. Placement of the electrode in the dentate gyrus of the hippocampus led to the detection of both KCl-induced release of L-glutamic acid and the release induced by stimulation of the axons in the perforant pathway. The development of this selective, sensitive and rapidly responding glutamate sensor should make it now possible to measure the dynamic events associated with glutamate neurotransmission in the central nervous system.

Animals↗

Enhanced immunogenicity of leucine enkephalin following coupling to anti-immunoglobulin and anti-CD3 antibodies.

Leucine enkephalin (Leu-enk) was coupled to both T and B cell antibodies in order to investigate the possibility of enhanced immunogenicity via targeted immunization. The two antibodies used were Hm x Mo CD3 and Gt x Mo Ig, respectively. The data indicate that while both antibody carriers enhanced the immunogenicity of Leu-enk, the use of the Hm x Mo CD3 antibody resulted in a greater number of mice with positive Leu-enk specific serum titers. 12 Leu-enk cell lines were produced and one, LE4H8, was chosen for characterization.

Amino Acid Sequence↗

Elimination of the acetaminophen interference in an implantable glucose sensor.

Acetaminophen has been one of the most serious electrochemical interferences to oxidase-based amperometric biosensors that measure H2O2. A study was carried out to investigate various polymer materials for their selectivity as the sensor inner membrane. A composite membrane of cellulose acetate and Nafion was found to eliminate acetaminophen and other electrochemical interferences effectively while at the same time maintaining reasonable diffusivity for hydrogen peroxide. The excellent in vivo performance of the sensor was attributed not only to significantly reduced steady-state sensitivity to acetaminophen but also to very slow acetaminophen response. These features, combined with rapid acetaminophen clearance pharmacokinetics, led to the decreased response as demonstrated in the rat.

Acetaminophen↗

Improved clean-up method for the enkephalins in plasma using immunoaffinity chromatography.

A rapid and selective method of sample clean-up using immunoaffinity chromatography (IAC) was developed to isolate enkephalins from plasma. The enkephalin antibodies were produced utilizing novel protein carriers. Two antibodies, LE4H8 and 33FC6, were selected because of their moderate binding affinity and different epitopes. Enkephalin-spiked plasma was loaded onto the immunoaffinity column and eluted with acidic pH buffer. The eluate was derivatized with naphthalene-2,3-dicarboxaldehyde in the presence of cyanide (NDA-CN), and the enkephalins were separated using reversed-phase liquid chromatography (RPLC). IAC sample clean-up of enkephalin-spiked plasma was compared to the existing solid-phase extraction method. The limit of detection for IAC was 30 pmol. The recovery of the enkephalins from plasma was 90% with a variance ranging from 2 to 9%. The immunoaffinity column was used for approximately 70 samples without any deterioration in performance.

Amino Acid Sequence↗

Reduction of acetaminophen interference in glucose sensors by a composite Nafion membrane: demonstration in rats and man.

Amperometric glucose sensors typically monitor the production of hydrogen peroxide generated in the course of the enzymatic oxidation of glucose. At the applied potential necessary to oxidize the peroxide produced, other species are also electroactive and contribute to the signal. Interference of ascorbate or urate has been effectively eliminated, but that resulting from the widely used analgesic acetaminophen is not. The aim of this work was to reduce this interference, which was found to be possible by introducing a membrane constructed of Nafion. We compared the in vitro sensitivity to acetaminophen of five Nafion sensors with that of five non-Nafion sensors with identical glucose sensitivity (2.0 +/- 0.4 vs 1.9 +/- 0.1 nA.mmol-1.l-1, NS): sensitivity to acetaminophen was 12.2 +/- 2.7 vs 30.8 +/- 6.3 nA.mmol-1.l-1, respectively (p < 0.05). These sensors were tested in rats by implanting in each animal one Nafion and one non-Nafion sensors. The in vivo sensitivity to glucose was similar (0.33 +/- 0.09 vs 0.30 +/- 0.05 nA.mmol-1.l-1, NS). The current generated by an acetaminophen infusion (plasma acetaminophen plateau = 140 +/- 10 mumol/l) was much decreased in the case of the Nafion sensor: 0.5 +/- 0.3 vs 2.0 +/- 0.7 nA, p < 0.05). Five Nafion sensors were implanted in the subcutaneous tissue of normal human volunteers who were given on oral dose of 500 mg acetaminophen.(ABSTRACT TRUNCATED AT 250 WORDS)

Acetaminophen↗

Pharmacokinetic studies of alpha-difluoromethylornithine in rabbits using an enzyme-linked immunosorbent assay.

Using an inhibition immunoassay, the pharmacokinetics of DFMO have been evaluated. After intravenous infusion, DFMO concentration in serum is observed to reach a maximum after 2-3 h followed by a decrease. This profile is consistent with the formation of a covalent adduct between DFMO and the enzyme which it irreversibly inhibits. The adduct was isolated by immunoaffinity chromatography.

Amino Acids↗