A comparison of a peripheral DXA system with conventional densitometry of the spine and femur.

Because of the perceived high cost of dual-energy X-ray absorptiometry (DXA) studies of the spine and femur, there is renewed interest in small, low-cost X-ray devices for scanning the peripheral skeleton. We have compared forearm bone mineral density (BMD) measurements (distal and ultradistal sites) performed on a DTX-200 (Osteometer MediTech, Hoersholm, Denmark) with spine (L1-L4) and femur (femoral neck and total hip sites) scans performed on a QDR-4500 (Hologic, Waltham, MA) in 172 white UK women aged 22-84 yr with a view to establishing differences caused by inconsistent reference ranges and different age-related changes in BMD. All BMDs were expressed as T-scores using the manufacturers' reference ranges for the forearm and spine, and the National Health and Nutrition Examination Survey (NHANES) ranges for the femur. Linear regression between peripheral and axial sites gave correlation coefficients r = 0.71-0.74 and roof mean standard errors (RMSE) 0.88-1.14 in T-score units. Subjects were divided into the following five age groups: <40 yr; 40-49 yr; 50-59 yr; 60-69 yr and >/=70 yr. A large systematic difference between distal and ultradistal T-scores (mean DeltaT = 0.59, SEM = 0.05) was found affecting all age groups. When the mean difference in T-score between each forearm site (distal, ultradistal) and each axial site (spine, femoral neck, total hip) was examined for premenopausal subjects (n = 58) the mean difference between forearm and axial T-score showed a consistent negative offset (DeltaT = -0.41 to -0.48) for the distal forearm site and a consistent positive offset (DeltaT = +0.30 to +0.37) for the ultradistal site. When interpreting results in postmenopausal women, age-related T-score changes in the forearm were in close agreement with the femoral neck region of exterest (ROI), but systematic differences were found between the forearm and the spine and total hip sites. The two forearm and three axial sites were compared to evaluate the number of postmenopausal subjects identified as osteoporotic on the basis of the World Health Organization (WHO) Study Group criteria (T-score <-2.5). Although forearm and spine T-scores identified approximately equal numbers of subjects as osteoporotic (distal 38/114; ultradistal 31/114; spine 30/114), the two femur sites identified fewer subjects as osteoporotic (femoral neck 25/114; total hip 16/114). The number for the total hip site was statistically significantly smaller than the spine and forearm sites.

Journal Article↗

Screening for osteopenia and osteoporosis: do the accepted normal ranges lead to overdiagnosis?

Osteoporosis is a common disease which causes significant morbidity and mortality and in many cases may be preventable. In the absence of fragility fractures the accepted method of identifying those at high risk is based upon bone mineral density (BMD) measurements with defined cut-off points. To correctly delineate normal from abnormal, reliable reference ranges appropriate to the observed population are required. We have studied the age-dependent changes in mean BMD and standard deviation at the lumbar spine and femoral neck in a normal population extracted from 4280 women screened for osteopenia and compared our findings with the manufacturer's normal range (MNR). The recent World Health Organization criteria for the diagnosis of osteopenia and osteoporosis using the 'manufacturer's young normal' (MYN) values and our 'study young normal' (SYN) values have been applied. The study normal population (SNP) included 2068 women (mixed social class; mean age 53 years, range 30-79 years). The distribution of mean lumbar spine BMD with age in SNP was generally similar to the MNR. In contrast mean femoral neck bone density from SNP was significantly different from the MNR, ranging from 3% to 12% lower in each 5-year group analysed (p < 0.05). Comparison of standard deviations in spine BMD in SNP against the fixed MNR standard deviation showed a statistically significant increase commencing at 45 years of age. The magnitude of this increase appeared to rise with age and remained significant in the 75- to 79-year age group (p < 0.05). In contrast, standard deviation in femoral neck BMD in SNP appeared relatively constant with age except in the group of women at and around the time of the menopause. The SYN value for mean lumbar spine BMD was 0.994 g/cm2 (cf. MYN value 1.047, p < 0.0001) with a standard deviation of 0.122 g/cm2 (cf. MYN 0.11, p = 0.0005). Similarly our SYN value for femoral neck BMD was 0.787 (cf. MYN value 0.895, p < 0.0001) with a standard deviation of 0.109 (cf. MYN value 0.10, p = 0.0027). Using SYN values 36% (748) for the spine and 33% (675) for the hip of our normal population are classified as osteopenic or osteoporotic. Using MYN values increases the proportion of women classified as osteopenic or osteoporotic to 52% (1078) for the spine and 68% (1409) for the femur. If both sites of measurement are considered simultaneously SYN classifies 46% (952) as either osteopenic or osteoporotic at one or other site, which is increased to 73% (1513) when the MYN values are used. We observe that manufacturer's reference ranges may not be appropriate for the local population and may lead to an erroneously high diagnosis of osteopenia and osteoporosis, which would lead to unnecessary patient anxiety and perhaps errors regarding treatment.

Adult↗

The effect of weight change on DXA scans in a 2-year trial of etidronate therapy.

Variation in soft tissue composition is a potential cause of error in dual X-ray absorptiometry (DXA) measurements of bone mineral density (BMD). We investigated the effect of patients' change of weight on DXA scans in 152 women enrolled in a 2-year trial of cyclical etidronate therapy. Scans of the spine, hip, and total body were performed at baseline, 1 and 2 years on a Hologic QDR-2000. The study was completed by 135 subjects (64 on etidronate, 71 on placebo). Results were expressed as the percentage change in BMD (spine, femoral neck, total body) or bone mineral content (BMC)(total body only) at 2 years. Total body scans were analyzed using the manufacturer's 'standard' and 'enhanced' algorithms. Analysis was performed using multivariate regression with percentage change in BMD or BMC as the dependent variable, and treatment group and percentage change in weight as the independent variables. Weight change varied between -14.4% and +16.7%. All DXA variables showed a statistically significant treatment effect. Standard total body BMD and BMC and enhanced total body BMC all showed a significant dependence on weight change (P < 0.01, P < 0.001 and P < 0.01, respectively). No effect of weight change was seen on spine, femoral neck, or enhanced total body BMD. In order to investigate the effects of weight on long-term precision, patients were allocated to two groups according to baseline body mass index (BMI < 25 and > 25 kg/m2, respectively). For femoral neck BMD the root mean square (RMS) residual percentage change was statistically significantly larger in the high BMI group (P < 0.05) but all other bone density variables showed no significant difference. With patients allocated to two groups according to their absolute percentage change in weight (< 5% and > 5%, respectively) the RMS residual percentage changes in the bone density variables were statistically significantly larger in the large weight change group for femoral neck BMD (P < 0.05) and for standard and enhanced total body BMC (P < 0.01 and P < 0.05, respectively). With the exception of the standard total body algorithm, weight change in a longitudinal study of postmenopausal women was not found to cause systematic errors in the results of DXA studies but may adversely affect precision.

Absorptiometry, Photon↗

Technical principles of dual energy x-ray absorptiometry.

Since its introduction nearly ten years ago, dual-energy x-ray absorptiometry (DXA) has become the single most widely used technique for performing bone densitometry studies. One reason for its popularity is the ability of DXA systems to measure bone mineral density (BMD) in the spine and proximal femur, the two most common sites for osteoporotic fractures. Other advantages of DXA include the exceptionally low radiation dose to patients, short scan times, high resolution images, good precision and inherent stability of calibration. For these reasons DXA scans are widely used to diagnose osteoporosis, assist making decisions in treatment, and as a follow-up response to therapy. Another important application has been the use of DXA in many clinical trials of new treatments for osteoporosis. Since the first generation pencil beam DXA systems became available, the most significant technical innovation has been the introduction of fan beam systems with shorter scan times, increased patient throughput, and improved image quality. New clinical applications include the measurement of lateral spine and total body BMD, body composition, and vertebral morphometry. Despite these advances, posteroanterior (PA) spine and proximal femur scans remain the most widely used application because of their utility in treatment decisions and monitoring response to therapy.

Absorptiometry, Photon↗

Interpretation of bone densitometry studies.

Dual-energy x-ray absorptiometry (DXA) is widely used for identifying patients with osteoporosis, making decisions about the commencement of preventive therapy, and following up response to treatment. It is important that radiologists and nuclear medicine physicians issuing clinical reports present clear interpretations that aid the primary care physician in making decisions affecting treatment. This review discusses the principles behind the interpretation of bone mineral density (BMD) studies. After a World Health Organization report published in 1994, osteoporosis is often diagnosed on the basis of the patient's T-score value (difference of BMD from young adult mean normalized to the population SD). T-scores are a measure of current fracture risk. There are problems relating to the use of T-scores in the elderly, and we argue that decisions about treatment are generally best made on the basis of the Z-score value (difference of BMD from age-matched mean normalized to the population SD) because this measures the patient's fracture risk relative to his or her peers. Recent studies confirm that the posteroanterior (PA) projection lumbar spine scan is still the optimum measurement site for monitoring response to treatment. A BMD change of 4.5% is required to register a statistically significant change.

Absorptiometry, Photon↗

Vertebral morphometry studies using dual-energy x-ray absorptiometry.

Vertebral fractures are one of the most common consequences of osteoporosis. They are usually diagnosed by visual interpretation of lateral radiographs of the lumbar and thoracic spine. Vertebral morphometry, based on measurements of the anterior, middle, and posterior heights of the vertebral bodies from T4 to L4, is a useful adjunct to the visual reading of radiographs. A new generation of dual-energy x-ray absorptiometry (DXA) scanners offers software for acquiring lateral images of the spine and performing vertebral morphometry analysis. Advantages of DXA morphometry include straightforward and reproducible patient positioning, absence of geometrical distortion of the image, low radiation dose, digital acquisition, and simplified, semi-automated scan analysis. The widespread availability of such DXA systems should make the investigation of vertebral fractures more widely accessible.

Absorptiometry, Photon↗

The prevention of early postmenopausal bone loss by cyclical etidronate therapy: a 2-year, double-blind, placebo-controlled study.

PURPOSE: To determine whether intermittent cyclical etidronate therapy can prevent early postmenopausal bone loss. PATIENTS AND METHOD: This was a 2-year outpatient, randomized, double-blind, placebo-controlled clinical trial. The subjects were 152 women within 1 to 10 years of the onset of menopause and bone mineral density (BMD) between 0 and -2 SD of normal values for a 50 year old woman. The women were stratified according to years since the menopause (1 to 3 years: n = 43; 4 to 6 years: n = 53; 7 to 10 years: n = 56). Measurements of lumbar spine, proximal femur and total body BMD were performed at baseline, 12 and 24 months by dual x-ray absorptiometry. Biochemical markers of bone resorption and bone formation were measured on the same visits. RESULTS: One hundred thirty-five subjects completed the study. Mean percentage change in lumbar spine BMD (and SEM) at 2 years was +2.14 (0.47)% in the etidronate group and -1.72 (0.41)% in the placebo group. Results for lumbar spine BMD in the treated and control groups stratified according to years since the menopause were: 1 to 3 years: +1.73 (0.84)% and -3.30 (0.70)%; 4 to 6 years: +1.37 (0.88)% and -1.80 (0.61)%; 7 to 10 years: +3.42 (0.61)% and -0.38 (0.70)%. The effect of both treatment group and menopausal stratum were highly statistically significant for lumbar spine and total body BMD. Treatment group, but not stratum, was significant for BMD in the proximal femur. Markers of bone resorption and bone formation were significantly decreased by etidronate therapy. CONCLUSIONS: Cyclical etidronate prevents bone loss in the total skeleton and at the clinically relevant sites (spine and proximal femur) even in the early postmenopausal years. Hence, it appears to be an effective and safe nonhormonal therapy in postmenopausal women with normal or low BMD.

Absorptiometry, Photon↗

Long-term precision of glomerular filtration rate measurements using 51Cr-EDTA plasma clearance.

The long-term precision of chromium-51 ethylenediamine tetraacetic acid (51Cr-EDTA) measurements of glomerular filtration rate (GFR) was evaluated in a retrospective study of data obtained over a 12 year period. Each GFR measurement was derived from plasma samples taken at 2, 3 and 4 h following injection of 3 MBq 51Cr-EDTA. The records of 7507 patients were reviewed, from which 55 subjects were identified as having had studies on 10 or more occasions. The mean number of studies per patient was 12.9 (range 10-23) over a mean period of 9.4 years (range 4.3-11.8 years). Plots of GFR, clearance half-life, (T1/2) and volume of distribution (VD) were drawn for each patient and used to identify subjects showing linear changes with time that could be fitted using linear regression. Each residual was expressed as a percentage of the expected value calculated from the regression line and all the residuals combined to give histograms for GFR, T1/2 and VD. Each histogram was fitted with a normal distribution between the -3 S.D. and +3 S.D. limits using weighted least squares. Final results for the coefficient of variation were: GFR 9.8%, T1/2 6.7%, VD 9.4%. The precision errors were used to calculate the smallest statistically significant change measurable by the 51Cr-EDTA technique. With 10% significance and 80% power, the smallest measureable change was 30% for GFR and 20% for T1/2. Unless there are clinical grounds for thinking that a patient's volume of distribution has changed, T1/2 is the optimal parameter for identifying real changes in renal function.

Chromium Radioisotopes↗

Bone densitometry: current status and future prospects.

Over the past decade, growing awareness of the impact of osteoporosis on the elderly population and the consequent costs of healthcare have stimulated development of new treatments to prevent fractures, together with new imaging technologies to assist in diagnosis. With its ability to perform high-precision measurements of bone mineral density (BMD) in the spine and hip, dual X-ray absorptiometry (DXA) is well suited to meet this latter need. However, there is continuing interest in smaller, less expensive, systems for assessing the peripheral skeleton. These include peripheral DXA scanning of the distal forearm and a variety of devices for performing quantitative ultrasound (QUS) measurements of broad-band ultrasonic attenuation (BUA) and speed of sound (SOS) in bone. Pivotal to all these developments is the demonstration in prospective studies that new technologies can reliably identify patients at risk of osteoporotic fractures. Whether DXA technology can meet the anticipated need for wider provision of diagnostic services is uncertain at present. The likely alternative is bone ultrasound. Although QUS technology is substantially cheaper than DXA and has proved its ability to predict fracture risk in the elderly, it is less precise, there is a lack of appropriate phantoms for quality control and there are doubts about how to interpret results in younger women.

Absorptiometry, Photon↗

A longitudinal study of supine lateral DXA of the lumbar spine: a comparison with posteroanterior spine, hip and total-body DXA.

We report a study to assess whether supine lateral dual-energy X-ray absorptiometry (DXA) scans of the lumbar spine provide better data for monitoring response to treatment than alternative measurement sites such as the posteroanterior (PA) spine, hip and total body. The study population was 152 women enrolled in a placebo-controlled clinical trial of cyclical etidronate therapy. All subjects were 1-10 years after the menopause with bone mineral density (BMD) between 0 and -2 SD of age-matched normal women. Paired PA and lateral spine, left hip and total-body DXA scans were performed at baseline, 1 year and 2 years on a Hologic QDR-2000. One hundred and thirty-one subjects completed the study. Mean percentage change from baseline at 2 years in the treated (n = 61) and control (n = 70) groups was calculated for vertebral body, width-adjusted (WA) vertebral body, mid-vertebral body and WA mid-vertebral body BMD measurement on the lateral scans and compared with the percentage changes in PA spine, femoral neck, trochanter, Ward's triangle and total-body BMD. The long-term precision for each BMD measurement site was obtained by linear regression analysis in subjects taking placebo. Overall treatment effect, defined as the difference in the percentage change in BMD in the two treatment groups at 2 years, was divided by long-term precision to give an index of the ability of each site to monitor response to treatment. Results (and standard errors) normalized to the ratio of treatment effect/ precision for PA spine BMD were as follows: PA spine, 1.00; vertebral body, 0.89 (0.14); WA vertebral body, 0.78 (0.14); mid-vertebral body, 0.65 (0.14); WA mid-vertebral body, 0.60 (0.13); femoral neck, 0.35 (0.15); trochanter, 0.45 (0.15); Ward's triangle, 0.59 (0.22); total body, 0.52 (0.19). Although treatment effect was larger for lateral than for PA spine BMD, this advantage was offset by the greater precision errors. PA spine BMD remains the optimum measurement for longitudinal studies in recently postmenopausal women.

Absorptiometry, Photon↗

Replacing DXA scanners: cross-calibration with phantoms may be misleading.

The high precision and stable calibration of dual X-ray absorptiometry (DXA) has led to its widespread use in clinical trials of new therapies for osteoporosis. Daily scanning of phantoms provides a check on the continuity of the bone mineral density (BMD) calibration and allows for correction of minor changes. However, because clinical trials may last up to 5 years, it is likely that the scanner will need replacing during the course of a study. We report the upgrade of a Hologic QDR-2000 to a QDR-2000plus. The new scanner was cross-calibrated with the old according to the manufacturer's instructions using the Hologic spine phantom. The accuracy of cross-calibration was checked by in vivo scans of patients in clinical trials and also using the European spine phantom (ESP). Daily QC scans with the Hologic phantom over the 6-week period of the in vivo study showed that the new scanner agreed within 0.2% with the old. However, in vivo scans at 10 sites in the spine, hip, total body, and forearm showed significant mismatch between the two systems with five sites differing by more than 2%. Results for the ESP phantom lay closer to the in vivo spine data than the Hologic phantom. The mismatch revealed was larger than anticipated and emphasized the importance of performing adequate in vivo cross-calibration studies whenever DXA systems are replaced. Typically, scans of 20-30 subjects are required at each scan site to achieve an accuracy of 1%. Such studies require careful planning and make significant demands on space, patient cooperation, scanning time, scientific resources, and, not least, the implementation of the findings.

Absorptiometry, Photon↗

Occupational dose to the radiographer in dual X-ray absorptiometry: a comparison of pencil-beam and fan-beam systems.

The introduction of advanced dual X-ray absorptiometry (DXA) scanners with fan-beam geometry, improved image definition and faster scan times raises the question as to whether there is a significant radiation dose to the radiographer. We have measured the radiation dose to the operator from studies performed on four DXA systems; the Lunar DPX, Hologic QDR-1000, QDR-2000 plus and QDR-4500. The results were compared with the radiographer dose from 99Tcm-MDP radionuclide bone scanning, where it is not usual to use a radiation barrier between the patient and the operator, and 18F-FDG positron emission tomography (PET) scanning where it is usual to protect staff. Ambient dose equivalent rate averaged over 1 h at 1 m from the patient with the DXA systems working at maximum patient throughput were 0.012, 0.12, 2.1 and 2.4 microSv h-1, respectively, for the DPX, QDR-1000, QDR-2000plus and QDR-4500. Annual operator dose for the DPX and QDR-1000 was well below the 1 mSv limit for members of the public recommended by the International Commission on Radiological Protection (ICRP) (1990). Results for the QDR-2000plus and QDR-4500 were similar to a radionuclide bone scan (2.2 microSv h-1), but smaller than for a PET scan (8.9 microSv h-1), and were close to the 5 mSv year-1 limit for a supervised area defined in the 1985 Ionising Radiation Regulations. Precautions to reduce radiographer dose with fan beam DXA include placing the operator at least 2 m from the patient, scanning the right hip instead of the left and using scan modes with short scanning times.

Absorptiometry, Photon↗

Concordance and precision of dual X-ray absorptiometry with a 10 s scan.

Development of dual energy X-ray absorptiometry (DXA) scanners with multidetector array technology has resulted in greatly shortened scanning times. The Hologic QDR-4500 includes an ultrafast (10 s) "turbo" scan mode recommended by the manufacturer for fast screening studies or as an aid to positioning the patient prior to scanning using the normal fast (30 s), medium (1 min) or high definition (2 min) modes. The suitability of the turbo mode for use in routine clinical studies was assessed by examining the concordance of bone mineral density (BMD) measurements obtained in this mode with measurements obtained using the three normal scanning modes. Studies in 151 female patients showed statistically significant discrepancies in four out of the six scan sites studied with systematic differences of 2.9% and 3.1% being observed for the posteroanterior (PA) spine and intertrochanteric region of the hip, respectively. In vivo precision for the 10 s scan found by performing duplicate measurements on 37 patients had a coefficient of variation of 1.3% for PA spine and 2.5% for femoral neck BMD. An investigation of the dependence of precision on body mass index (BMI) shows that the precision of spine and hip BMD was adversely affected with increasing BMI but the trend was statistically significant only in the spine. It was concluded that turbo mode scans are acceptable for routine clinical studies of the spine and hip but should not be used for longitudinal studies or patients with BMI greater than 30 kg m-2.

Absorptiometry, Photon↗

The accuracy of volumetric bone density measurements in dual x-ray absorptiometry.

New developments in dual x-ray absorptiometry (DXA) allow the performance of high precision anteroposterior (AP) and lateral scans of spinal bone mineral density (BMD, units: g/cm2) without the patient moving from the supine position. Data from both projections may be combined to give an estimate of the true volumetric bone mineral density (VBMD, units: g/cm3) of the lumbar vertebral bodies. This report presents a cadaver study designed to validate DXA measurements of volumetric bone density. Sections of whole lumbar spine were scanned in AP and lateral projections in a water tank to simulate soft tissue. Individual vertebrae were then divided to separate the vertebral body from the neural arch, and vertebral body volume was measured using the displacement of sand. The bone mineral content (BMC) of vertebral bodies and neural arches was measured by ashing at 250 degrees C for 60 hours followed by 500 degrees C for a further 24 hours. The results showed that DXA scanning systematically underestimated ashing data by 14% for AP BMC, 33% for vertebral body BMC, 23% for vertebral body volume, and 12% for VBMD. Despite these significant systematic errors, the DXA measurements and ashing values were highly correlated (r = 0.979-0.992). The results suggested that after allowing for the systematic errors, lateral DXA parameters related closely to true BMC, volume, and VBMD.

Absorptiometry, Photon↗

Distribution of bone mineral density in the lumbar spine in health and osteoporosis.

The significance of variability in bone mineral density (BMD) between lumbar vertebrae L1 to L4 in the same individual was investigated by dual-energy X-ray absorptiometry in 1000 normal women aged 40-60 years (average 52 years) and 145 women aged 45-80 years (average 65 years) with vertebral osteoporosis. The mean BMD increased from L1 to L4 in normal women from 0.841 g/cm2 to 1.017 g/cm2, and in osteoporotics from 0.562 g/cm2 to 0.709 g/cm2. Z scores for osteoporotic women (Z = osteoporotic BMD - age-normal BMD/normal SD) were significantly lower for individual vertebrae compared with L1-4 and at L4 compared with L1, L2 and L3 (p < 0.001). The mean difference between Z scores for the highest and lowest vertebrae in an individual was 0.70 for normals (SD = 0.40) and 0.64 for osteoporotics (SD = 0.36). The mean Z score difference between the L1-4 Z score and the lowest individual vertebral Z score was 0.36 for normals (SD = 0.23) and 0.06 for osteoporotics (SD = 0.31). However, receiver operating analysis (ROC) curves showed that the lowest Z score for any individual vertebra did not provide improved discrimination between normals and osteoporotics when compared with the L1-4 Z score. The area under the ROC curve for L1-4 was significantly greater than for individual vertebrae (p < 0.05) and that for L4 was significantly smaller than for L1, L2 or L3 (p < 0.001). In conclusion, L1-4 BMD gives greater diagnostic sensitivity for osteoporosis than individual vertebrae, and L1, L2 and L3 are better than L4.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Patient dose in dual x-ray absorptiometry.

Dual x-ray absorptiometry (DXA) provides a convenient, non-invasive method of assessing skeletal bone mineral which is widely used for clinical studies. This report describes a study to estimate the effective dose of radiation (ICRP-60 (1990)) to a typical female patient from scans performed on three DXA scanners: the Hologic QDR-1000, QDR-1000/W and QDR-2000. The scans modes studied were: total body; anteroposterior (AP) lumbar spine; lateral lumbar spine; proximal femur; distal forearm. An ionization chamber and tissue-equivalent phantom were used to determine entrance surface dose and percentage depth-dose curves for each scan mode. Anatomical data from ICRP-23 (Reference Man) and a body section atlas were used to estimate the absorbed dose to each organ in the scan fields. Effective dose was estimated using the ICRP-60 tissue weighting factors and the fraction of each organ in the scan field. Results are summarized below. Figures for the effective dose are given both excluding and (in brackets) including the ovaries to cover the cases of postmenopausal and premenopausal women respectively.

Absorptiometry, Photon↗

Post-menopausal vertebral osteoporosis: can dual energy X-ray absorptiometry forearm bone density substitute for axial measurements?

This study compared measurements of BMD using dual energy X-ray absorptiometry (DXA) at three sites in the nondominant forearm (ultradistal, distal one-third and a mid-region between these two), the lumbar spine (L1-L4) and the proximal femur (femoral neck, trochanter and Ward's triangle) for the evaluation of vertebral osteoporosis. Studies were performed on 100 normal women aged 29-69 yr (average 52 yr) and 63 osteoporotic women age 48-75 yr (average 66 yr) using the Hologic QDR-1000. Precision values of < 1% were obtained in both normal and osteoporotic women at both forearm and axial sites. Z-scores for the osteoporotics [Z = (mean BMD normal--mean abnormal)/S.D.] were--2.02 lumbar spine, -1.96 femoral neck, -1.79 ultradistal forearm, -1.73 mid region and -1.66 distal one-third forearm. Receiver operating characteristic curves showed that the lumbar spine and femoral neck equally discriminated between normals and osteoporotics with a 95% area under each curve, significantly greater values than those for the forearm which were 87% ultradistal, 89% mid forearm and 86% distal one-third forearm. Fracture thresholds, defined as the 90th centile of BMD for osteoporotic patients, were 1 S.D. below the normal mean for lumbar spine and femoral neck but equal to the mean for ultradistal, 0.6 S.D. below mean for mid region and 0.3 S.D. below mean for distal one-third region. We conclude that for the discrimination of normals and osteoporotic women the three forearm sites are comparable. However, both lumbar spine and proximal femur BMD are superior to all forearm sites.

Absorptiometry, Photon↗