Developments, complications and limitations of catheter-mediated electrical ablation of posterior accessory atrioventricular pathways.

Nineteen patients with posterior accessory pathways and disabling, refractory arrhythmias, underwent catheter ablation using standard defibrillator pulses at energy settings of 150 to 400 J. Accessory pathway ablation was successful in 13 of 19 (68%). Effective catheter ablation correlated with local ventriculoatrial (VA) intervals determined from the coronary sinus catheter at the site of earliest retrograde atrial activation during orthodromic reciprocating tachycardia. In 12 of the 13 successfully ablated patients, the local VA interval was less than 80 ms. In 4 of the 6 unsuccessfully treated patients, the local VA interval was greater than or equal to 80 ms, p less than 0.01. Transient abnormalities noted with the procedure included sinus bradycardia (3 patients), atrioventricular block (5), accelerated junctional rhythm (3), ectopic atrial tachycardia (2), myocardial depression (1), "ischemic" appearing T-wave inversions (10) and hemodynamically insignificant small pericardial effusions (5) Creatine kinase-MB increased from 3 +/- 2 U/liter to 26 +/- 18 U/liter (p less than 0.001), 4 to 8 hours after ablation. In addition, electrical shorts occurring during the ablation procedure in 2 patients were identified and corrected only with oscilloscopic monitoring of voltage and current waveforms. Significant adverse sequelae were seen in 4 patients. Three patients required sternotomy for control of cardiac tamponade secondary to a ruptured coronary sinus and 1 patient had a small posterior left ventricular infarction related to spasm of a right coronary artery extension branch. Coronary sinus rupture correlated with the ratio of catheter diameter to coronary sinus diameter.(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗

Tocainide for drug-resistant sustained ventricular tachyarrhythmias.

Eighty-two patients with drug-resistant ventricular tachycardia or fibrillation were treated with oral tocainide. Treatment in 54 patients, all with inducible ventricular tachycardia or fibrillation at baseline electrophysiologic testing, was based on the results of invasive electrophysiologic testing. Twenty-eight additional patients with frequent spontaneous ventricular tachycardia or no inducible arrhythmia during electrophysiologic testing were treated on the basis of the findings of electrocardiographic (ECG) Holter monitoring. Tocainide was effective in 7 (13%) and partially effective in 5 (8%) of the 54 patients in the electrophysiologic study group and was effective in 17 (61%) of the 28 patients in the ECG monitoring group. History of previous myocardial infarction and failure of response to lidocaine correlated with failure to respond to tocainide. Side effects were common both during initial therapy and during long-term treatment and necessitated discontinuation of tocainide therapy in 17% of the patients. At a mean follow-up period of 14 months, 13 patients are still receiving tocainide and are arrhythmia-free. In conclusion, the usefulness of oral tocainide in the management of drug-refractory sustained ventricular tachycardia or fibrillation is limited because of its low effectiveness and frequent side effects.

Anti-Arrhythmia Agents↗

Sustained ventricular arrhythmias: differences between survivors of cardiac arrest and patients with recurrent sustained ventricular tachycardia.

Clinical, angiographic, echocardiographic and electrophysiologic data were examined in 101 patients with a history of sustained ventricular arrhythmia not associated with acute myocardial infarction. These patients included 66 survivors of out of hospital cardiac arrest and 35 patients presenting with hemodynamically well tolerated sustained ventricular tachycardia. On univariate analysis, patients in the cardiac arrest group had a lower incidence of previous myocardial infarction and left ventricular aneurysm and a higher ejection fraction compared with the ventricular tachycardia group. During electrophysiologic testing, the arrhythmia induced in the patients in the cardiac arrest group was fast and polymorphic and frequently degenerated into ventricular fibrillation. In contrast, in the ventricular tachycardia group, a slower, monomorphic and hemodynamically well tolerated ventricular tachycardia was commonly induced. On multivariate analysis, a polymorphic pattern of the induced ventricular arrhythmia was the only independent variable that distinguished the survivors of cardiac arrest from those presenting with sustained ventricular tachycardia. These results suggest that 1) the survivors of cardiac arrest and patients presenting with sustained well tolerated ventricular tachycardia are clinically distinct groups; and 2) the polymorphic tachycardia induced during programmed electrical stimulation in the survivors of cardiac arrest may indicate an unstable tachycardia mechanism. This may explain why these patients present with ventricular fibrillation and cardiac arrest, whereas others present with hemodynamically stable ventricular tachycardia.

Aged↗

Catheter-mediated electrical ablation: the relation between current and pulse width on voltage breakdown and shock-wave generation.

Voltage waveform breakdown is characteristic of barotraumatic shock-wave generation during electrical catheter ablation of cardiac arrhythmias. The purpose of this investigation was to avoid barotrauma by defining, in vitro, the limits of pulse amplitude and pulse width for rectangular constant-current pulses that do not result in voltage breakdown and subsequently to determine what pulsing frequency is safe for use when high-energy trains of pulses are used. Electric pulses were delivered with a variable waveform modulator with a wide dynamic range and bandwidth capable of delivering pulses of 30-10,000-mu sec duration with amplitudes of up to 25 A. Cathodal pulses were delivered to a 6F catheter immersed in fresh anticoagulated bovine blood warmed to 37 degrees C to stimulate the milieu of a catheter in the chambers of the human heart. The maximum pulse amplitude that could be delivered without incurring voltage waveform breakdown varied inversely with pulse duration. Pulses of 30 mu sec broke down at currents above 24 A (2,500 V). Pulses of 10,000-mu sec duration broke down at 1 A (250 V). The maximum safely delivered energy for a single pulse was 2.5 J for pulses of 80-120 mu sec. Peak power for single pulses was maximum at 50-55 kW with 30-50-mu sec pulses. Charge delivery for single pulses was maximized at 9 mC with long, 10,000-mu sec duration pulses. To deliver an electrical pulse with energy significantly greater than 2.5 J without incurring voltage breakdown, trains of pulses were delivered where each pulse in the train had previously been shown to be free of voltage breakdown.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Intraoperative comparison of sequential-pulse and single-pulse defibrillation in candidates for automatic implantable defibrillators.

Sixteen survivors of cardiac arrest underwent intraoperative comparison of the effectiveness of sequential-pulse and single-pulse defibrillation. Defibrillation was tested alternately with the single-pulse or sequential-pulse technique 10 seconds into an episode of ventricular fibrillation that was induced with alternating current. The sequential-pulse defibrillation technique using truncated exponential pulses was performed with a right ventricular endocardial catheter and a left ventricular epicardial patch electrode. The first pulse was delivered between the right ventricular apical and the superior vena caval electrode on the right ventricular endocardial catheter. The second pulse was delivered between the right ventricular apical electrode and the left ventricular patch electrode 0.2 ms after termination of the first pulse. Single-pulse defibrillation was performed with a standard intracardiac defibrillation system in which a single truncated exponential pulse was delivered across 2 epicardial patch electrodes positioned over the anterolateral right ventricle and the posterolateral left ventricle. During defibrillation threshold determination, voltage and current waveforms were recorded and integrated to determine delivered energy. Average defibrillation threshold leading-edge voltage for the sequential pulse technique was 496 +/- 140 V, compared with 365 +/- 157 V for the single-pulse technique (p less than 0.005). Defibrillation threshold leading-edge current for the sequential-pulse technique was 6.0 +/- 2.3 A, compared with 10.6 +/- 5.1 A for the single-pulse method (p less than 0.0005).(ABSTRACT TRUNCATED AT 250 WORDS)

Aged↗

Determinants of induced sustained arrhythmias in survivors of out-of-hospital ventricular fibrillation.

We prospectively studied 196 consecutive survivors of out-of-hospital ventricular fibrillation (VF) not associated with acute myocardial infarction and 46 consecutive, control patients without prior ventricular arrhythmias. Programmed stimulation included two extrastimuli (S3 protocol) in all patients and three extrastimuli (S4 protocol) in the last 140 study patients and in all control patients. Sustained ventricular tachycardia (VT) or VF was not induced in any control patient. In study patients, logistic regression identified two independent predictors of induced, sustained VT for both S3 and S4 protocols: prior spontaneous, sustained VT (37 patients; p less than or equal to .001) and prior myocardial infarction (113 patients; p = .005). With the S3 protocol, sustained VT was induced in 54% of patients with both prior myocardial infarction and prior sustained VT vs 4% without either; with the S4 protocol, sustained VT was induced in 91% vs 13%, respectively. Eighty-three percent of induced VT episodes had a cycle length less than 300 msec, and all required termination by cardioversion or pacing. VF was induced only in survivors of out-of-hospital VF without prior, spontaneous, sustained VT (S3 protocol, 9%; S4 protocol, 24%) but not in study patients with prior sustained VT (S3, p = .10; S4, p = .05) or control patients (S3, p = .06; S4, p = .01). The mean coupling intervals of extrastimuli that induced VF were not significantly different from the intervals that induced sustained VT.(ABSTRACT TRUNCATED AT 250 WORDS)

Arrhythmias, Cardiac↗

Tachycardia-induced cardiomyopathy: a reversible form of left ventricular dysfunction.

Eight patients, aged 5 to 57 years, with uncontrolled symptomatic tachycardia for 2.5 to 41 years (mean 15) and significant left ventricular (LV) dysfunction in the absence of any other apparent underlying cardiac disease underwent evaluation. Incessant tachycardia was present for 0.5 to 6.0 years (mean 2.1) in 7 patients. One patient had an ectopic atrial tachycardia and 7 patients had an accessory atrioventricular pathway that participated in reciprocating tachycardia. Six patients underwent surgery; the ectopic focus was ablated in 1 patient and an accessory pathway was divided in 5 patients. One patient underwent open ablation of the His bundle and 1 patient underwent closed-chest ablation of the atrioventricular conduction system. Myocardial biopsy specimens were obtained from 5 patients, none of which yielded a specific diagnosis. Pretreatment radionuclide angiography demonstrated a mean ejection fraction (EF) of 19 +/- 9% (range 10 to 35%). Following tachycardia control a marked improvement in LV function was noted in 6 of 8 patients at rest and in 1 additional patient during exercise. The EF increased to 33 +/- 17% (range 16 to 56%) an average of 8 days after treatment and to 45 +/- 15% (range 22 to 67%) at late follow-up 3.5 +/- 40 months (mean 17) later (p less than 0.005). Seven patients remain asymptomatic 11 to 40 months (mean 22) after the corrective procedure and have resumed normal activities. These findings suggest that chronic uncontrolled tachycardia may result in significant LV dysfunction, which is reversible in some cases after control of the arrhythmia.

Adolescent↗

Intolerance and ineffectiveness of mexiletine in patients with serious ventricular arrhythmias.

Fifty-one patients were treated with mexiletine over 10.4 +/- 16 months. The clinical arrhythmia in 25 (49%) was ventricular fibrillation (VF), 11 (22%) had sustained ventricular tachycardia (VT), and 15 (29%) had symptomatic nonsustained VT. Ischemic heart disease was present in 33 patients (66%), cardiomyopathy in nine (17%), and valvular or congenital heart disease in nine (17%). Only six (12%) remain on the drug. Arrhythmias recurred in 21 patients (41%): seven (14%) with VF, three (5%) with sustained VT, and 11 (22%) with symptomatic nonsustained VT. Intolerable side effects occurred in another 17 (33%). Seven patients (14%) died from nonarrhythmic-related deaths while taking mexiletine. Mexiletine was combined with a conventional type IA antiarrhythmic agent in 25 patients (49%). In 12 of these 25 patients (48%), ventricular arrhythmias recurred. These findings were not significantly different from those of the group treated with mexiletine alone, where arrhythmias recurred in 9 of 26 patients (35%) (p = NS). Thus mexiletine, alone or in combination with a type IA antiarrhythmic agent, has limited clinical utility in patients with life-threatening ventricular arrhythmias.

Cardiac Pacing, Artificial↗

Catheter-mediated electrical ablation: the relation between current and pulse width on voltage breakdown and shock-wave generation.

Barotrauma from arc induced shock waves may result in dangerous sequelae during ablation of arrhythmogenic foci. In this report, maximum pulse amplitude and pulse width determinations were made to assess avoidance of shock-wave generation using rectangular constant current pulses. Energy delivery appears to be optimal between 80-100 microseconds. If higher energies are required, multiple pulses will be needed to avoid barotrauma.

Animals↗

Some factors affecting bubble formation with catheter-mediated defibrillator pulses.

Factors affecting bubble formation during delivery of defibrillator pulses to arrhythmogenic cardiac tissue via a catheter are unknown. We investigated the role of energy, electrode surface area, interelectrode distance, and electrode polarity on bubble formation and on current and voltage waveforms during delivery of damped sinusoidal discharges from a standard defibrillator to anticoagulated bovine blood. Gas composition was studied with mass spectrometry. Defibrillator energy settings were varied between 5 and 360 J. The principal catheter used for study was a Medtronic 6992A lead. Additional electrodes tested included 2, 5, and 10 mm long No. 6F, 7F, and 8F copper electrodes. Interelectrode distances used to assess the effect of anode-cathode spacing were 1, 5, 10, and 20 cm. Bubble volume increased linearly from 0.043 to 0.134 ml per cathodal pulse and from 0.030 to 3.50 ml per anodal pulse as energy settings were increased from 5 to 360 J (r = .99). Typical smooth waveforms for both current and voltage were seen only in the absence of bubbles. The voltage waveform was distorted for each cathodal pulse of 100 J or more and for each anodal pulse of 10 J or more only if bubbles were present. The effect of electrode surface area on bubble formation was tested at a 200 J energy setting and at a 10 cm interelectrode distance with the use of cathodal pulses. Bubble formation varied inversely with electrode surface area (r = .876). Bubble formation, however, varied minimally as interelectrode spacing was changed from 1 to 20 cm. The effect of polarity on bubble formation when the Medtronic 6992A distal electrode and an 8.5 cm disk electrode separated by 10 cm were used was highly significant. For a 200 J pulse, bubble formation with the catheter as anode was 3.30 +/- 0.10 ml and with the catheter as cathode it was 0.070 +/- 0.002 ml (p less than .001). Mass spectrometry of both anodal and cathodal gas samples demonstrated the constituents of the gas bubble to include a variety of gases, which is inconsistent with simple electrolytic production of the bubbles observed. The predominance of nitrogen in either polarity sample suggested that the principal source of the bubble was dissolved air. In summary, bubble formation at an electrode receiving damped sinusoidal outputs from a standard defibrillator does not vary significantly with varying interelectrode distance. However, it is directly proportional to energy and inversely proportional to electrode surface area. Anodal catheter discharges produce considerably more bubbles than do cathodal discharges.(ABSTRACT TRUNCATED AT 400 WORDS)

Catheterization↗

Effects of varying electrode configuration with catheter-mediated defibrillator pulses at the coronary sinus orifice in dogs.

We compared two methods of delivering single damped sine-wave defibrillator pulses to the coronary sinus orifice in 20 dogs. Ten dogs had "unipolar" (coronary sinus to precordial disc) and 10 had "bipolar" (coronary sinus proximal to coronary sinus distal electrode) discharges. Delivered voltage, current, and energy were recorded during each pulse. Electrophysiologic testing was done before and 4 weeks after the procedure. Histologic examination of the atrioventricular groove was done at 1 mm serial sections. For the unipolar configuration a 200 J defibrillator pulse resulted in a peak voltage of 3370 +/- 125 V, a peak current of 21 +/- 4 A, and a delivered energy of 253 +/- 29 J as compared with 3010 +/- 99 V, 70 +/- 4 A, and 144 +/- 18 J, respectively, for the bipolar configuration (p less than .001). Three dogs (two with bipolar, one with unipolar pulses) had gross coronary sinus rupture and died from acute pericardial tamponade. In addition, irrespective of electrode configuration, all dogs showed microscopic rupture of the coronary sinus internal elastic membrane. Transmural atrial scarring occurred in all 10 dogs that received a unipolar pulse but in only two dogs that received a bipolar pulse (p = .0004). Unlike the atrium, injury to the left ventricle was limited in both groups. Similarly, injury to the periannular myocardium was inconsistent and not transmural in either group. No significant electrophysiologic changes were observed. With the present technique, unipolar rather than bipolar catheter-mediated defibrillator pulses result in transmural atrial injury that might prevent accessory pathway conduction. Regardless of electrode configuration, high-energy defibrillator pulses consistently cause some degree of coronary sinus rupture, most likely related to a barotraumatic mechanism.

Animals↗

Wide complex tachycardia: misdiagnosis and outcome after emergent therapy.

The extent and consequence of misdiagnosis of wide complex tachycardia (QRS, 120 ms or more; heart rate, 100 or more beats/min) presenting emergently were assessed. Forty-six consecutive episodes of wide complex tachycardia were reviewed and their tachycardia mechanisms subsequently established. All 8 episodes of supraventricular tachycardia with aberrant conduction were correctly diagnosed, whereas 15 of 38 episodes of ventricular tachycardia (39%) were misdiagnosed as supraventricular tachycardia at the time initial therapy was given. Ventriculoatrial dissociation was evident in 11 (73%) of the electrocardiograms of misdiagnosed ventricular tachycardia. Patients with misdiagnosed episodes had poorer outcomes than those with episodes correctly diagnosed (p = 0.0003). Verapamil was administered to patients in 13 of the 15 episodes of misdiagnosed ventricular tachycardia; hemodynamic deterioration occurred in all 13 episodes. Wide complex tachycardia is often incorrectly diagnosed as supraventricular tachycardia when, in fact, the 12-lead electrocardiogram strongly suggests ventricular tachycardia. Verapamil is commonly administered in these circumstances and is frequently associated with a poor outcome.

Adolescent↗

Double tachycardia following surgery for recurrent ventricular arrhythmias.

Simultaneous accelerated "junctional" rhythm and atrial flutter were observed postoperatively in a patient who had undergone electrophysiologic surgery for recurrent ventricular fibrillation. Digitalis toxicity was excluded, based on the low serum level of the drug and on the recurrence of the tachycardia after withdrawal of digitalis. While atrial flutter probably represented a postoperative recurrence of a clinically occurring arrhythmia, the accelerated "junctional" rhythm at unusually fast rates most likely developed as a consequence of a cryolesion applied to the ventricular septum as part of the surgical treatment. Phenytoin proved effective in suppressing this "junctional" tachycardia.

Aged↗

Effect of damped sine-wave shocks on catheter dielectric strength.

This study evaluated the ability of 24 new standard tripolar and quadripolar U.S. Catheter Instruments catheters to withstand a single damped sinusoidal shock delivered by a standard defibrillator. The schema for energy delivery was meant to simulate possible clinical practices. Delivered peak voltage and current were measured during each shock. Each electrode was examined for pitting and changes in line resistance as a consequence of the shock. Electrode pitting occurred on all selected anodal poles. However, it also was found on "unsolicited" electrodes from 7 catheters, indicating that current had followed unanticipated routes. Electrode line resistance was unmeasurable in 6 of these 7 inappropriately pitted electrodes. Delivered peak voltage and postshock catheter dielectric strength depended on the manner of energy delivery. To simulate a posterior septal accessory pathway ablation procedure, a shock was delivered to 2 proximal (anodal) poles in 16 quadripolar catheters (8 received 200 J and 8 received 360 J). Delivered peak voltage was 3,125 +/- 362 V for the 200-J shock and 4,100 +/- 160 V for the 360-J shock. Postshock catheter dielectric strength for the 200- and 360-J shock was 1,425 +/- 826 V and 601 +/- 707 V, respectively. This was significantly lower than peak delivered voltage (p less than 0.001 for either energy). To simulate His bundle or ventricular tachycardia focus ablation, 8 tripolar catheters each received a single 200-J shock to the tip electrode. This resulted in a delivered peak voltage of 2,900 +/- 351 V, compared with a postshock dielectric strength of 1,325 +/- 1,320 V (p less than 0.002).(ABSTRACT TRUNCATED AT 250 WORDS)

Cardiac Catheterization↗

Comparison of two-dimensional echocardiographic and angiographic findings in arrhythmogenic right ventricular dysplasia.

Comparison of 2-dimensional (2-D) echocardiographic and right ventricular (RV) angiographic findings was performed in 10 patients with arrhythmogenic RV dysplasia. Diagnosis was based on accepted electrocardiographic and angiographic criteria. Nine patients underwent invasive electrophysiologic study, which confirmed RV source of ventricular tachycardia (VT) in 7. Biopsy findings of RV dysplasia were available in 3 patients. Two-dimensional echocardiography and angiography corresponded closely when diffuse RV enlargement and hypokinesia were present. Such diffuse findings were not invariably present. Localized abnormalities consisting of bulging or sacculation of the RV wall were noted by both techniques, even in the absence of diffuse changes. Echocardiographic evidence of localized disease predicted the presence of similar lesions at angiography, but agreement as to specific location was poor. Subjectivity in interpreting subtle RV abnormalities by either technique and the inherent differences in information provided by the 2 methods probably account for the inconsistencies. In the patient with suspected arrhythmogenic RV dysplasia, 2-D echocardiographic evidence of diffuse RV enlargement, otherwise unexplained, strongly supports the diagnosis and angiography may be avoided. Isolated local changes seen by echocardiography should increase suspicion of RV dysplasia, but complementary angiographic study is warranted.

Adolescent↗