Search PubMed⌕ Search

Biomedical subjects

G Brix

Publications and source records attributed to G Brix.

At least 55 records · Page 3Linked to original sources

Uterine cervical carcinoma: comparison of standard and pharmacokinetic analysis of time-intensity curves for assessment of tumor angiogenesis and patient survival.

Dynamic studies of Gd-based contrast agents in magnetic resonance imaging (MRI) are increasingly being used for tumor characterization as well as for therapy response monitoring. Because detailed knowledge regarding the pathophysiological properties, which in turn are responsible for differences in contrast enhancement, remains fairly undetermined, it was the aim of this study to: (a) examine the association of standard and pharmacokinetic analysis of time-intensity curves in dynamic MRI with histomorphological markers of tumor angiogenesis [microvessel density (MVD) and vascular endothelial growth factor (VEGF)]; and (b) determine the ultimate value of a histomorphological and a dynamic MRI approach by the correlation of those data with disease outcome in patients with primary cancer of the uterine cervix. Pharmacokinetic parameters (amplitude, A; exchange rate constant, k21) and standard parameters [the maximum signal intensity increase over baseline (SI-I) and the steepest signal intensity-upslope per second (SI-U/s)] were calculated from a contrast-enhanced dynamic MRI series in 37 patients with biopsy-proven primary cervical cancer. On the surgical whole mount specimens, histomorphological markers of tumor angiogenesis (MVD and VEGF) were compared to MRI-derived parameters. For MRI and histomorphological data, Kaplan-Meier survival curves were calculated and compared using log-rank statistics. A significant association was found between MVD and A (P < 0.01) and SI-I (P < 0.05). No significant relationships were observed between VEGF expression and all dynamic MRI parameters. Kaplan-Meier curves based on k21 and SI-U/s showed that tumors with high k21 and SI-U/s values had a significantly (P < 0.05 and 0.001, respectively) worse disease outcome than did tumors with low k21 and SI-U/s values. None of the histomorphological gold standard markers for assessing tumor angiogenesis (MVD and VEGF) had any significant power to predict patient survival. It is concluded that in patients with uterine cervical cancer: (a) the pathophysiological basis for differences in dynamic MRI is MVD but not VEGF expression; (b) a functional, dynamic MRI approach (both standard and pharmacokinetic analysis) may be better suited to assess angiogenic activity in terms of patient survival than are the current histomorphological-based markers of tumor angiogenesis; and (c) compared with standard analysis, a simple pharmacokinetic analysis of time-intensity curves is not superior to assess MVD or patient survival.

Contrast Media↗

[Angiogenesis of cervix carcinoma. Contrast enhanced dynamic MRI, histologic quantification of capillary density and lymphatic system infiltration].

PURPOSE: It was the aim of this project to examine (i) the relationships between contrast-enhanced dynamic MR imaging derived characteristics and histologic microvessel density counts--a recognized surrogate of tumor angiogenesis--from tumors in patients with primary or recurrent cancer of the uterine cervix, and (ii) to correlate these parameters with lymphatic involvement (i.e. lymphatic channels) to assess tumor biological aggressiveness in terms of lymphatic spread. MATERIAL AND METHODS: Pharmacokinetic MR imaging parameters (amplitude A, exchange rate constant k21) were derived from contrast-enhanced dynamic MR imaging in thirty-three patients with biopsy proven cancer of the uterine cervix. The pharmacokinetic MR imaging characteristics were correlated to histologic capillary density counts obtained from whole mount specimen. In addition, these data were correlated to the angiogenic activity as a marker for lymphatic system involvement. RESULTS: Pharmacokinetic MR imaging derived parameters (A, k21) showed a weak but significant (p < 0.05) correlation with microvessel density counts. Lymphatic involvement was more comprehensively assessed by the pharmacokinetic parameter k21 compared with histologic microvessel density, resulting in a significantly (p < 0.05) higher overall accuracy (85% vs. 64%), sensitivity (83% vs. 54%), and comparable specificity (89% vs. 89%), respectively. CONCLUSION: Our first results show that the signal-time curves measured by contrast-enhanced MR imaging are only in part influenced by microvessel density. In addition, MR imaging derived characteristics may assess tumor biological aggressiveness in terms of lymphatic spread (i.e. lymphatic channels) more comprehensively than histologic microvessel density in patients with primary or recurrent cancer of the uterine cervix.

Adult↗

[Multiple reader analysis for evaluation of functional MR mammography].

The diagnostic impact and reproducibility of the different methods used within the concept of functional MR-Mammography (FMRM) was assessed by a multi-reader-analysis. By four experienced readers, 100 histologically confirmed cases were evaluated in six different sessions. Per session, one of the following components was analyzed: clinical history (I), static MRM (II), color-coded projection images (III), time-signal curves of contrast enhancement within a large ROI (IV) and the strongest enhancing pixel (V) obtained from the histologically confirmed lesion and the complete FMRM reading (VI). The functional methods (IV-VI) revealed significantly (p < 0.05) higher specificities than the others (I-III). The highest reproducibility between the readers was observed for (IV) phi chi = 0.80, (V) phi chi = 0.76 and FMRM (VI) phi chi = 0.63. These three methods also presented the best ROC-curves and showed the highest complementarity with respect to the false positive classifications in x-ray mammography. FMRM is a reader independent, reproducible method. The analysis of the contrast enhancement time-intensity curves with high temporal resolution allows an improved differentiation of malignant and benign findings.

Adult↗

[Safety considerations to avoid current-induced skin burns in MRI procedures].

The safety aspects of radiological methods continue to evolve. In this paper we report on two cases of skin burns in MRI caused by induced electrical current. A second- and a third-degree skin burn occurred during imaging in a 1.5 T system. The electromagnetic radiofrequency field inadvertently led to electrical currents caused by a conducting loop through the extremities and trunk. Skin burns induced by electrical current may occur in extremely rare cases even with standard MR imaging protocols operating within all current safety guidelines by inadvertently forming a closed conducting loop. By avoiding focal skin to skin contact of the extremities, this extremely rare adverse event can be avoided.

Adult↗

Functional magnetic resonance imaging of category-specific cortical activation: evidence for semantic maps.

Functional magnetic resonance imaging (fMRI) was used to examine the pattern of cortical activity during a picture naming task. Subjects (n=12) had to covertly name either animals or furniture items. Functional scanning was performed using a conventional 1.5-Tesla whole-body MRI system. Images obtained during naming the two categories were compared using a non-parametric test. The study revealed evidence for domain-specific lexical regions in left middle, right middle and inferior frontal areas, as well as in superior and middle temporal areas. The results corroborate neuropsychological data and demonstrate directly and non-invasively in human volunteers that semantic representations in frontal and temporal areas are, to some degree, localized and possibly implemented as multiple maps. A completely distributed storage of semantic information is rendered unlikely.

Adult↗

Uncoupling of 2-fluoro-2-deoxyglucose transport and phosphorylation in rat hepatoma during gene therapy with HSV thymidine kinase.

This animal study investigates the application of positron emission tomography (PET) with tracers of tumour metabolism for monitoring suicide gene therapy with herpes simplex virus thymidine kinase (HSVtk). After transplantation of HSVtk-expressing Morris hepatoma cells into ACI rats, dynamic PET measurements of 18F-labeled 2-fluoro-2-deoxyglucose (FDG) uptake were performed in animals 2 days (n = 7) and 4 days (n = 5) after the onset of therapy with 100 mg ganciclovir (GCV)/kg body weight as well as after administration of sodium chloride (n = 8). The arterial FDG plasma concentration was measured dynamically in an extracorporeal loop and the rate constants for FDG transport (K1, k2) and FDG phosphorylation (k3) were calculated using a three-compartment model modified for heterogeneous tissues. Also, quantification using the metabolic rate of FDG turnover and the standardized uptake value (SUV) was done. Furthermore, the thymidine incorporation into the tumour DNA was determined after i.v. administration of 3H-thymidine. An uncoupling of FDG transport and phosphorylation was found with enhanced K1 and k2 values and a normal k3 after 2 days of GCV treatment. The increase in FDG transport normalized after 4 days whereas the phosphorylation rate k3 increased. Quantification using the metabolic rate or the SUV showed congruent but less sensitive results compared with the modeling approach. The thymidine incorporation into the DNA of the tumours declined to 10.5% of the controls after 4 days of GCV treatment. The data indicate that PET with 18FDG and 11C-thymidine may be applied for monitoring of gene therapy with the HSVtk/GCV suicide system. Increased transport rates are evidence of stress reactions early after therapy. The measurement of thymidine incorporation into the tumour DNA can be used as an indicator of therapy efficacy.

Animals↗

[Functional magnetic resonance tomography in psychopathological research].

Mental disorders are characterised by psychopathological symptoms which correspond to functional brain states. Functional magnetic resonance imaging (fMRI) is used for the non-invasive study of cerebral activation patterns in man. First of all, the neurobiological principles and presuppositions of the method are outlined. Results from the Heidelberg imaging lab on several simple sensorimotor tasks as well as higher cognitive functions, such as working and semantic memory, are then presented. Thereafter, results from preliminary fMRI studies of psychopathological symptoms are discussed, with emphasis on hallucinations, psychomotoric phenomena, emotions, as well as obsessions and compulsions. Functional MRI is limited by the physics underlying the method, as well as by practical constraints regarding its use in conjunction with mentally ill patients. Within this framework, the problems of signal-to-noise ratio, data analysis strategies, motion correction, and neurovascular coupling are considered. Because of the rapid development of the field of fMRI, maps of higher cognitive functions and their respective pathology seem to be coming within easy reach.

Brain↗

Cerebral blood flow and cerebrovascular reserve capacity: estimation by dynamic magnetic resonance imaging.

We have developed a new method for estimation of regional CBF (rCBF) and cerebrovascular reserve capacity on a pixel-by-pixel basis by means of dynamic magnetic resonance imaging (MRI). Thirteen healthy volunteers, 8 patients with occlusion and/or high grade stenosis of the internal carotid artery (ICA), and 2 patients with acute stroke underwent dynamic susceptibility-weighted contrast enhanced MRI. Using principles of indicator dilution theory and deconvolution analysis, maps of rCBF, regional cerebral blood volume, and of the mean transit time (MTT) were calculated. In patients with ICA occlusion/stenosis, cerebrovascular reserve capacity was assessed by the rCBF increase after acetazolamide stimulation. Mean gray and white matter rCBF values in normals were 67.1 and 23.7 mL x 100 g(-1) x min(-1), respectively. Before acetazolamide stimulation, six of eight patients with ICA occlusions showed decreased rCBF values; and in seven patients increased MTT values were observed in tissue ipsilateral to the occlusion. After acetazolamide stimulation, decreased cerebrovascular reserve capacity was observed in five of eight patients with ICA occlusion. In acute stroke, rCBF in the central core of ischemia was less than 8 mL x 100 g(-1) x min(-1). In peri-infarct tissue, rCBF and MTT were higher than in unaffected tissue but rCBF was normal. Dynamic MRI provides important clinical information on the hemodynamic state of brain tissue in patients with occlusive cerebrovascular disease or acute stroke.

Acute Disease↗

Intra- and extracellular fluorouracil uptake: assessment with contrast-enhanced metabolic F-19 MR imaging.

PURPOSE: To assess the extra- and intracellular uptake of the anticancer drug fluorouracil and its major catabolite alpha-fluoro-beta-alanine (FBAL) at gadolinium-enhanced fluorine-19 magnetic resonance (MR) imaging. MATERIALS AND METHODS: The relative fluorouracil and FBAL F-19 signal intensity increases due to extracellular and hepatobiliary paramagnetic contrast media were evaluated in ACI rats with transplanted Morris hepatoma. Control rats (n = 6) did not receive contrast medium; study rats received gadopentetate dimeglumine (n = 6) or gadoxetic acid (n = 6) before intravenous fluorouracil administration. The biodistributions of fluorouracil and FBAL were mapped at metabolic F-19 MR imaging at about 6 minutes (early distribution phase) and 64 minutes (metabolic phase), respectively, after drug administration. RESULTS: Gadopentetate dimeglumine induced a significant (P < .05) increase in the signal intensity of fluorouracil (70%) in the hepatoma; gadoxetic acid induced a significant increase in the signal intensity of fluorouracil in the hepatoma (85%) and of FBAL in the liver (71%). The fluorouracil liver signal intensity did not increase with either contrast medium. CONCLUSION: Whereas a marked amount of fluorouracil is in the extracellular tumor compartment 6 minutes after fluorouracil administration, the dominant fluorouracil signal intensity in the liver at 6 minutes arises from the intracellular compartment, which can be explained as retention of fluorouracil in hepatocytes. The marked increase in the FBAL signal intensity about 1 hour after fluorouracil administration is congruent with our observation of a high intracellular uptake of gadoxetic acid in the liver at about 1 hour.

Animals↗

[Optimization of PET image quality by means of 3D data acquisition and iterative image reconstruction].

PURPOSE: In the recent past, several algorithms have been developed in order to transform 3D sinograms acquired at volume PET systems into 2D data sets. These methods offer the possibility to combine the high sensitivity of the 3D measurement with the advantages of iterative 2D image reconstruction. The purpose of our study was the assessment of this approach by using phantom measurements and patient examinations. METHODS: The experiments were performed at the latest-generation whole-body PET system ECAT EXACT HR+. For 2D data acquisition, a collimator of thin tungsten septa was positioned in the field-of-view. Prior to image reconstruction, the measured 3D data were sorted into 2D sinograms by suing the Fourier rebinning (FORE) algorithm developed by M. Defrise. The standard filtered backprojection (FBP) method and an optimized ML/EM algorithm with overrelaxation for accelerated convergence were employed for image reconstruction. The spatial resolution of both methods as well as the convergence and noise properties of the ML/EM algorithm were studied in phantom measurements. Furthermore, patient data were acquired in the 2D mode as well as in the 3D mode and reconstructed with both techniques. RESULTS: At the same spatial resolution, the ML/EM-reconstructed images showed fewer and less prominent artefacts than the FBP-reconstructed images. The resulting improved detail conspicuously was achieved for the data acquired in the 2D mode as well as in the 3D mode. The best image quality was obtained by iterative 2D reconstruction of 3D data sets which were previously rebinned into 2D sinograms with help of the FORE algorithm. The phantom measurements revealed that 50 iteration steps with the optimized ML/EM algorithm were sufficient to keep the relative quantitation error below 5%. CONCLUSION: Our measurements show that the image quality in 3D PET can be improved by using iterative reconstruction techniques. The concept of 3D data acquisition and combining the FORE algorithm with 2D ML/EM reconstruction can readily be employed in clinical practice since the computation time is not considerably longer than that in iterative reconstruction of true 2D data.

Aged↗

[Investigation of the signal-to-noise ratio on a state-of-the-art PET system: measurements with the EEC whole-body phantom].

AIM: The spatial resolution of PET scanners can be improved by using smaller detector elements. This approach, however, results in poorer counting statistics of the reconstructed images. Therefore, the aim of this study was to investigate the influence of different acquisition parameters on the signal-to-noise ratio (SNR) and thus to optimize PET image quality. METHODS: The experiments were performed with the latest-generation whole-body PET system (ECAT Exact HR+, Siemens/CTI) using the standard 2D and 3D data acquisition parameters recommended by the manufacturer. The EEC whole-body phantom with different inserts was used to simulate patient examinations of the thorax. Emission and transmission scans were acquired with varying numbers of events and at different settings of the lower level energy discriminator. The influence of the number of counts on the SNR was parameterized using a simple model function. RESULTS: For count rates frequently encountered in clinical PET studies, the emission scan has a stronger influence on the SNR in the reconstructed image than the transmission scan. The SNR can be improved by using a higher setting of the lower energy level provided that the total number of counts is kept constant. Based on the established model function, the relative duration of the emission scan with respect to the total acquisition time was optimized, yielding a value of about 75% for both the 2D and 3D mode. CONCLUSION: The presented phenomenological approach can readily be employed to optimize the SNR and thus the quality of PET images acquired at different scanners or with different examination protocols.

Computer Simulation↗

Dose-response relationship for late functional changes in the rat brain after radiosurgery evaluated by magnetic resonance imaging.

PURPOSE: Only few quantitative data are available on late effects in the healthy brain after radiosurgery. An animal model can contribute to systematically investigate such late effects. Therefore, a model applying radiosurgery at the rat brain was established. A long-term (19 months) follow up study with 66 animals after radiosurgery was carried out. METHODS AND MATERIALS: In 60 animals, an area in the frontal lobe of the brain was irradiated stereotactically with a 15 MV linac. Different doses of 20, 30, 40, 50, and 100 Gy with two field sizes (3.9 and 5.9 mm collimator) were selected, using the integrated logistic formula with input parameters from human brain. The induced alteration of the blood-brain barrier permeability was investigated by means of contrast enhanced magnetic resonance imaging. RESULTS: A first intracranial signal enhancement was observed in one animal 160 days after irradiation with 100 Gy. Beginning at 5 months all animals in the two 100 Gy groups homogeneously showed contrast enhancement, but none of the other groups. This remained until 13 months after irradiation. The volume of contrast enhancement as well as the increase of signal intensity were different between the two 100 Gy groups. After 19 months, the animals irradiated with lower doses also showed contrast enhancements, although not uniformly throughout one group. A maximum likelihood fit of the logistic formula P(D) = 1/[1 + (D50/D)k] to the incidence of late effects for the 5.9 mm collimator at 19 months after irradiation results in the parameters D50 = 37.4(-5.2,+6.1) Gy and k = 4.7 +/- 2.4. CONCLUSIONS: An animal model was established to study late normal brain tissue response. The observed late effects appeared very similar to the estimation of the integrated logistic formula for human brain. Based on these radiosurgery techniques, future experiments will focus on modifications in the irradiation modalities, i.e., irregular volumes, radiation quality or fractionation.

Animals↗

Angiogenesis of uterine cervical carcinoma: characterization by pharmacokinetic magnetic resonance parameters and histological microvessel density with correlation to lymphatic involvement.

Dynamic studies of Gd-based contrast agents in magnetic resonance imaging (MRI) are increasingly being used for tumor characterization as well as therapy response monitoring. Because detailed knowledge regarding the pathophysiological properties, which in turn are responsible for differences in contrast enhancement, remains fairly undetermined, it was the aim of this project to: (a) examine the relationship between contrast-enhanced dynamic MRI-derived characteristics and histological microvessel density counts, a recognized surrogate of tumor angiogenesis, from primary or recurrent cancers of the uterine cervix; and (b) correlate these parameters with lymphatic involvement to characterize tumor aggressiveness in terms of lymphatic spread. Pharmacokinetic parameters (amplitude, A; exchange rate constant, k21) were calculated from a contrast-enhanced dynamic MRI series in 55 patients (ages 25-72 years; mean, 50 years) with biopsy-proven primary (n = 42) or recurrent (n = 13) uterine cervical cancer. Both pharmacokinetic parameters were correlated to histologically determined microvessel density counts (factor VIII-related antigen) and other pathological tumor characteristics obtained from the operative specimens after radical surgery. In addition, the magnetic resonance and histological data were correlated to the presence or absence of lymphatic system involvement. Pharmacokinetic MRI-derived parameters (A and k21) increased with increasing histological microvessel density counts with r = 0.41 and 0.50, respectively. Lymphatic involvement was more comprehensibly assessed by the pharmacokinetic parameter k21 compared with histological microvessel density, resulting in a higher sensitivity, overall accuracy, and comparable specificity. Contrast-enhanced MRI parameters might prove to be applicable for estimation of tumor angiogenesis in uterine cervical cancer; thus, MRI may become an additional tool to characterize malignant progression in terms of lymphatic involvement in uterine cervical cancer.

Adenocarcinoma↗

Pharmacokinetic analysis of 5-[18F]fluorouracil tissue concentrations measured with positron emission tomography in patients with liver metastases from colorectal adenocarcinoma.

The purpose of our study was to develop a pharmacokinetic model to quantify the intracellular 5-fluorouracil (5-FU) concentration in liver metastases, which is expected to be closely correlated to therapy response. In addition, the influence of the biomodulator folinic acid on the action of 5-FU in the metastases was investigated. After i.v. application of 5-FU labeled with the positron emitter fluorine-18 (5-[18F]FU), the kinetics of the regional 5-[18F]FU/uptake was measured dynamically with positron emission tomography over 120 min in 14 patients with a total of 27 liver metastases from colorectal adenocarcinoma. Activity-time curves were evaluated in the metastases, the normal liver tissue, as well as in the aorta and analyzed by a six-compartment model. The catabolic breakdown of 5-FU to alpha-fluoro-beta-alanine (FBAL) in the normal liver tissue was modeled to separate the catabolites from the cytostatic agent 5-[18F]FU and the active 5-[18F]fluorodeoxyuridine nucleotides. With our model, all measured activity-time courses could be described adequately with only small interindividual variations in parameters connected with liver and blood. Extrahepatic clearance of 5-FU was estimated as 0.66 +/- 0.33 liters/min, whereas the hepatic clearance was 0.52 +/- 0.25 liters/min. The Michaelis-Menten parameters describing the nonlinear conversion of 5-FU to FBAL were Km = 11.3 +/- 6.4 micromol and Vmax = 147.1 +/- 130.7 micromol/min. The maximum FBAL concentration in the liver was reached between 35 and 65 min after i.v. 5-FU infusion. The most sensitive parameters for therapy monitoring were k(in) and k(out), which characterize the transport in and out of the intracellular volume of the metastases, respectively. Tumor response can only be expected if k(in) is high and k(out) is low ("trapping"). These criteria were met by 6 of the 27 metastases, which were identical to those with high values for the area under the intracellular 5-FU concentration curve (AUC[meta,IC]5-FU). The parameters k(in) and k(out) were also used to investigate the influence of the biomodulating agent folinic acid on drug effect. Five of the six metastases that showed trapping belonged to patients who received folinic acid. With the exception of one patient, however, all patients who received folinic acid had multiple metastases, of which only one was able to trap 5-FU. Because patient response can only be expected when all metastases trap 5-FU, folinic acid showed no effect on the overall clinical response. With the quantitative modeling approach used, trapping of 5-FU can be assessed noninvasively and on an individual basis. This makes it possible to adjust the dose for each individual patient to optimize the treatment schedule.

Adult↗

Use of scanner characteristics in iterative image reconstruction for high-resolution positron emission tomography studies of small animals.

The purpose of this work was to improve of the spatial resolution of a whole-body positron emission tomography (PET) system for experimental studies of small animals by incorporation of scanner characteristics into the process of iterative image reconstruction. The image-forming characteristics of the PET camera were characterized by a spatially variant line-spread function (LSF), which was determined from 49 activated copper-64 line sources positioned over a field of view (FOV) of 21.0 cm. This information was used to model the image degradation process. During the course of iterative image reconstruction, the forward projection of the estimated image was blurred with the LSF at each iteration step before the estimated projections were compared with the measured projections. The imaging characteristics of the high-resolution algorithm were investigated in phantom experiments. Moreover, imaging studies of a rat and two nude mice were performed to evaluate the imaging properties of our approach in vivo. The spatial resolution of the scanner perpendicular to the direction of projection could be approximated by a one-dimensional Gaussian-shaped LSF with a full-width at half-maximum increasing from 6.5 mm at the centre to 6.7 mm at a radial distance of 10.5 cm. The incorporation of this blurring kernel into the iteration formula resulted in a significantly improved spatial resolution of about 3.9 mm over the examined FOV. As demonstrated by the phantom and the animal experiments, the high-resolution algorithm not only led to a better contrast resolution in the reconstructed emission scans but also improved the accuracy for quantitating activity concentrations in small tissue structures without leading to an amplification of image noise or image mottle. The presented data-handling strategy incorporates the image restoration step directly into the process of algebraic image reconstruction and obviates the need for ill-conditioned "deconvolution" procedures to be performed on the projections or on the reconstructed image. In our experience, the proposed algorithm is of special interest in experimental studies of small animals.

Algorithms↗

[Contrast-enhanced MR "magnetization transfer technique". Improved tumor contrast, delineation and visibility of intracranial malignant gliomas and metastases in radiosurgical treatment planning].

AIMS: To improve tumor conspicuity and delineation on contrast-enhanced T1-weighted MR images with and without magnetization transfer (MT) contrast as a strategy to improve the macroscopic boost volume definition in the planning process of radiosurgery in patients with high grade gliomas or metastatic brain lesions. PATIENTS AND METHODS: Thirty-two patients (mean age 47 years) with histologically proven or suspected high grade glioma (n = 12) or metastatic brain lesions (n = 20) were prospectively examined by MR imaging. After the administration of gadolinium dimeglumine (0.1 mmol/kg body weight) the lesions were imaged with a T1-weighted MT-fast low angle shot (FLASH) pulse sequence and with a conventional T1-weighted SE sequence without MT saturation. RESULTS: The mean CNR of enhancing lesions on T1-weighted MT-FLASH was 15 +/- 5 compared to 11 +/- 4 on SE images, representing a significant (p < .01) improvement. The mean tumor diameter of malignant gliomas was significantly (p < .01) larger measured on T1-weighted MT-FLASH images compared to those obtained from T1-weighted SE images and were comparable for metastatic lesions. Lesion conspicuity and delineation were improved in 50% of patients with high grade gliomas and in 35% of patients with brain metastases. Lesion conspicuity was markedly improved in the posterior fossa. Additional contrast enhancing lesions were detected in 10% of patients with metastases on MT-FLASH images. CONCLUSIONS: It is concluded that contrast-enhanced MT-FLASH images may improve lesion detection and delineation in the planning process of radiosurgery in patients with intracranial high grade gliomas or metastases or even alter the treatment approach.

Adult↗

Functional neuroimaging in the assessment of CNS neoplasms.

Assessment of CNS neoplasms has focused traditionally on morphological analysis. Recent developments in MR sequence design now enable functional assessments. T1-weighted, as well as T2(*)-weighted, dynamic, gadolinium-enhanced, imaging can be used for assessment of vascularisation, permeability, and microcirculation of CNS neoplasms. Characterisation of cerebrovascular blood flow is possible using dynamic MR angiography, while neurofunctional imaging enables visualisation of local alterations in neuronal activity in stimulated cortical areas. Diffusion-weighted imaging can be used for improved delineation of neoplasms, while chemical shift imaging allows metabolic mapping of lesions and surrounding tissues. Implementation of these techniques can improve characterisation, information for therapy, planning and prognosis in clinical imaging of CNS neoplasms.

Brain↗

[Invasive cervix carcinoma (pT2b-pT4a). Value of conventional and pharmacokinetic magnetic resonance tomography (MRI) in comparison with extensive cross sections and histopathologic findings].

PURPOSE: To compare staging of advanced primary cervical carcinoma (pT2b-pT4a) by conventional and pharmacokinetic magnetic resonance imaging (MRI) with the giant cross section specimen and histopathological findings. MATERIALS AND METHODS: Seventeen patients with biopsy-proven cancer of the cervix and clinically suspected invasive cancer (FIGO IIB-IVA) were prospectively examined by conventional (T2 and contrast-enhanced T1-weighted spin echo images) and pharmacokinetic MRI. All MRI findings were compared with the giant cross section specimen and histopathology as the standard of reference. For pharmacokinetic MRI, a saturation recovery TurboFLASH sequence was used with a high temporal resolution of 13 s per ten sections. Signal time changes were analyzed using a pharmacokinetic model and the computed parameter values were visualized by color-coded overlay. RESULTS: Analysis of parametrial invasion on T2-weighted images resulted in an accuracy of 85% and 73% on contrast-enhanced T1-weighted images and on pharmacokinetic MR images respectively. Accuracy of analysis of bladder and/or rectal wall invasion was significantly (P < 0.05) higher on pharmacokinetic MR images (88%) than on T2-weighted images (67%). Contrast-enhanced T1-weighted spin-echo images improved staging accuracy compared with T2-weighted images (76% vs 67%). CONCLUSION: At present, conventional T2-weighted SE images are superior to contrast-enhanced T1-weighted SE and pharmacokinetic MR images in depicting infiltration of the parametrium. However, suspected infiltration of the bladder and/or rectum (pT4a) is diagnosed more accurately on pharmacokinetic images than on conventional MR images.

Adolescent↗