Search PubMed⌕ Search

Biomedical subjects

G Brix

Publications and source records attributed to G Brix.

At least 37 records · Page 2Linked to original sources

Elastic matching of dynamic MR mammographic images.

Dynamic magnetic resonance imaging (MRI) carried out with paramagnetic contrast media has been proven to increase sensitivity and specificity in the detection of breast cancer. Due to movements of the patients and changes in the shape of the breasts during the measurement period, a coregistration (matching) of the acquired data volumes is necessary to obtain higher accuracy for the localization of lesions. In this study, an algorithm for the elastic matching of dynamic MRI volume data is presented. The approach includes automatic feature extraction along with the analysis of corresponding features between the data sets. The matching is actually slice-oriented, even though information on displacement vectors in adjacent slices is taken into account. An extension of the procedure to fully three-dimensionally (3D) matching is straight forward. Up until now, the approach has been applied to 20 dynamic MRI studies. The matching time for two image data sets with 256 x 256 x 15 voxels each was about 4 min using a PC (Pentium Pro, 200MHz).

Algorithms↗

[Dynamic MR mammography. Multidimensional visualization of contrast medium enhancement in virtual reality].

BACKGROUND: The purpose of this study was the development of a method for fast and efficient analysis of dynamic MR images of the female breast. The image data sets were acquired with a saturation-recovery turbo-FLASH sequence which enables the detection of the kinetics of the contrast agent concentration in the whole breast with a high temporal and spatial resolution. In addition, a morphologic 3D-FLASH data set was acquired. METHODS: The dynamic image datasets were analyzed by a pharmacokinetic model which enables the representation of the relevant functional tissue information by two parameters. In order to display simultaneously morphologic and functional tissue information, we developed a multidimensional visualization system, which enables a practical and intuitive human-computer interface in virtual reality. DISCUSSIONS: The developed system allows the fast and efficient analysis of dynamic MR data sets. An important clinical application is the localization and definition of multiple lesions of the female breast.

Adult↗

Comparison of rigid and elastic matching of dynamic magnetic resonance mammographic images by mutual information.

The present study aims at (i) the evaluation of the performance of a rigid and of an elastic matching algorithm for the coregistration of dynamic magnetic resonance (MR) images visualizing the female breast, and (ii) the evaluation of the mutual information (MI) as a matching criterion. To this end, ten patient data sets were analyzed. The comparison was performed with respect to the achieved increase in the MI and by visual inspection of the dynamic image series in a continuous film sequence ((cine mode). In most cases, the achieved increase in MI by elastic image registration is much higher than that achieved by rigid registration. Only for three of the ten data sets could the MI be increased by rigid image registration to a similar or even larger degree than by elastic image registration. Taking into account the results of the visual inspection of the rigid and elastic matched data sets, however, the elastic match leads to equal or better results for all data sets. Therefore, elastic matching is the gold standard for the registration of dynamic MR mammographic images of the female breast. The comparison of the increase in MI and the visual inspection further shows that the visual impression agrees in most cases with the result of the calculation of the MI. Therefore, the MI proves to be a suitable matching criterion for the type of data sets studied.

Algorithms↗

[Diagnostic evaluation of the breast using PET: optimization of data acquisition and postprocessing].

PURPOSE: Development and evaluation of an optimized protocol for PET examinations of the female breast with 2-F-18-fluoro-2-deoxyglucose (F-18-FDG). METHODS: All PET measurements were performed with a whole-body PET system (ECAT EXACT HR+). In order to examine the women with the breasts freely pendant, a special extension for the patient table made of carbon layer composite was designed. After data acquisition in the 3D modus, emission data were sorted into 2D sinograms using the Fourier rebinning algorithm and reconstructed by means of an ultra-fast iterative 2D algorithm (HOSP). The reconstructed emission scans were superimposed onto the corresponding transmission images. The protocol presented was evaluated in examinations on 6 women with breast lesions after the administration of 150-220 MBq F-18-FDG. From two adjacent bed positions, emission and transmission data were acquired over periods of 20 min and 10 min, respectively. For comparison, dynamic magnetic resonance (MR) image series were acquired with a whole-body MR system (MAGNETOM SP 4000) using a double-breast coil. RESULTS AND CONCLUSION: Using the designed extension of the patient table, it was possible to examine corpulent women despite the limited patient port of the PET system in the prone position with the breasts freely pendant. Alongside a reduction in motion artifacts, this positioning also offers the possibility of making a direct comparison between PET and MR images. Despite the fact that the amount of F-18-FDG applied to the patient was markedly reduced, the combination of 3D data acquisition and iterative image reconstruction resulted in excellent quality of the emission scans. By super-positioning of iteratively reconstructed emission and transmission scans, anatomical localization of breast lesions visualized on the emission scans could be improved. The postprocessing of the PET data described was completed in 60 min, this meaning that the presented concept can readily be employed in clinical practice.

Algorithms↗

[Evaluation of a scatter correction technique for single photon transmission measurements in PET by means of Monte Carlo simulations].

PURPOSE: Single photon transmission (SPT) measurements offer a new approach for the determination of attenuation correction factors (ACF) in PET. A major drawback of this method is the high fraction of scattered photons in the transmission sinogram resulting in a marked underestimation of the ACFs. It was, therefore, the aim of the present work, to evaluate a scatter correction algorithm proposed by C. Watson by means of Monte Carlo simulations. METHODS: SPT measurements with a Cs-137 point source were simulated for a whole-body PET scanner (ECAT EXACT HR+) in both the 2D and 3D mode. To examine the scatter fraction (SF) in the transmission data, the detected photons were classified as unscattered or scattered. The simulated data were used to determine (i) the spatial distribution of the SFs, (ii) an ACF sinogram from all detected events (ACFtot) and (iii) from the unscattered events only (ACFunscattered), and (iv) an ACFcor = (ACFtot)1 + kappa sinogram corrected according to the Watson algorithm. In addition, density images were reconstructed in order to quantitatively evaluate linear attenuation coefficients. RESULTS: A high correlation was found between the SF and the ACFtot sinograms. For the cylinder and the EEC phantom, similar correction factors kappa were estimated. The determined values resulted in an accurate scatter correction in both the 2D and 3D mode. CONCLUSIONS: The algorithm proposed by Watson allows an accurate correction of scattered radiation in SPT measurements. The correction factor kappa can by determined experimentally using simple phantoms and then applied to more complex objects. SPT measurements should be performed in the 3D mode, in order to increase the total numb of counts and/or to reduce the measurement time.

Algorithms↗

Synergistic interaction of ultrasonic shock waves and hyperthermia in the Dunning prostate tumor R3327-AT1.

Pulsed high-energy ultrasound shock waves (PHEUS), similar to those used for clinical lithotripsy, can deposit energy deep in tissue and thereby destroy the microvasculature of solid tumors. We investigated the potential of PHEUS, generated by an electromagnetic shockwave source (19 kV capacitor voltage, 1 Hz pulse frequency), as a local cancer-therapy modality alone and in combination with local tumor hyperthermia (43.5 +/- 0.1 degrees C, 30 min). Copenhagen rats transplanted with the anaplastic Dunning-prostate-tumor sub-line R3327-AT1 received 1000 PHEUS pulses, which delayed tumor growth by one tumor-doubling time (5 days). Histopathology revealed hemorrhage, disruption of tumor vasculature, and necrosis in the focus of the sound field. Bromodeoxyuridine (BUdR) incorporation was significantly lower in PHEUS-treated tumors than in controls. Dynamic magnetic resonance imaging (MRI) studies using gadolinium-DTPA as contrast agent showed a strong reduction of tumor perfusion after PHEUS treatment, although this effect was partly reversible within 3 days after PHEUS. While hyperthermia alone produced no significant delay in tumor growth, the combination of PHEUS and hyperthermia produced tumor-growth delay by 2 tumor-volume-doubling times. The maximum growth delay was achieved when PHEUS and hyperthermia were separated by 24 hr at the time of maximum perfusion reduction indicated by MRI. Thus, the cytotoxic effect of PHEUS was enhanced by hyperthermia in the anaplastic prostate tumor R3327-AT1 grown on Copenhagen rats in a synergistic manner, due to blood-flow reduction. In conjunction with other agents, such as hyperthermia, PHEUS might become a local cancer-therapy modality in solid tumors accessible to ultrasound.

Animals↗

Assessment of hepatic perfusion in pigs by pharmacokinetic analysis of dynamic MR images.

The purpose of this study was to evaluate a new method based on magnetic resonance imaging for the characterization of hepatic perfusion. In nine pigs dynamic MRI was performed before and after partial occlusion of the portal vein. The pharmacokinetic analysis of the contrast enhancement resulted in a set of parameters (amplitude, A; perfusion rate, kp; elimination rate, kappa(e1); lag time, t(lag)) of which kp was expected to correlate with hepatic perfusion. Reference measurements were done with ultrasound flow-meters and with a thermal diffusion probe (TDP). MR perfusion rate kp significantly dropped under partial portal vein occlusion from an average of 11.3 to 4.9 min(-1) (P < 0.001), while the difference in amplitude A was not significant. The correlation between kp and the TDP measurement was r = 0.89 (P < 0.001). Pharmacokinetic analysis of MRI contrast enhancement provides a non-invasive assessment of hepatic perfusion.

Animals↗

Estimating kinetic parameters from dynamic contrast-enhanced T(1)-weighted MRI of a diffusable tracer: standardized quantities and symbols.

We describe a standard set of quantity names and symbols related to the estimation of kinetic parameters from dynamic contrast-enhanced T(1)-weighted magnetic resonance imaging data, using diffusable agents such as gadopentetate dimeglumine (Gd-DTPA). These include a) the volume transfer constant K(trans) (min(-1)); b) the volume of extravascular extracellular space (EES) per unit volume of tissue v(e) (0 < v(e) < 1); and c) the flux rate constant between EES and plasma k(ep) (min(-1)). The rate constant is the ratio of the transfer constant to the EES (k(ep) = K(trans)/v(e)). Under flow-limited conditions K(trans) equals the blood plasma flow per unit volume of tissue; under permeability-limited conditions K(trans) equals the permeability surface area product per unit volume of tissue. We relate these quantities to previously published work from our groups; our future publications will refer to these standardized terms, and we propose that these be adopted as international standards.

Contrast Media↗

Multicompartment analysis of gadolinium chelate kinetics: blood-tissue exchange in mammary tumors as monitored by dynamic MR imaging.

The blood-tissue exchange kinetics of gadopentetate were studied in 49 malignant and benign mammary tumors. Signal enhancement was monitored simultaneously in the aorta and in tumor for 10.5 minutes after the beginning of a 1 minute i.v. infusion of the contrast medium (CM). Kinetic analysis was based on a model with two compartments for systemic pharmacokinetics and up to three kinetically distinct compartments for tumor. Kinetic heterogeneity, ie, two or more compartments with different exchange rate constants in a given tumor, was found in 85% of carcinomas, 38% of fibroadenomas, and 14% of mastopathic tumors. The within-tumor average of CM exchange rates was 1.22 (0.62-1.65) min(-1) in carcinomas, 0.38 (0.26-0.60) min(-1) in fibroadenomas, and 0.16 (0. 12-0.20) min(-1) in mastopathies (median and interquartile distances). The area under the signal enhancement-time curve of the aorta varied 4.5-fold between individuals. It is concluded that individual CM kinetics in arterial blood should be taken into account when CM exchange rates between blood and tumor are to be determined and that a kinetic model for potentially malignant tumors should allow for kinetic heterogeneity.

Adenocarcinoma↗

Pathophysiologic basis of contrast enhancement in breast tumors.

While the diagnostic benefits of gadolinium (Gd)-chelate contrast agents are firmly established in magnetic resonance imaging (MRI) of tumors, the pathophysiologic basis of the enhancement observed and its histopathologic correlate remained vague. Tumor angiogenesis is fundamental for growth and metastasis and also of interest in new therapeutic concepts. By correlative analysis of a) histology; b) vascular density (CD31); and c) vascular permeability (vascular permeability factor/vascular endothelial growth factor [VPF/VEGF]), we found a) significantly (P < 0.001) faster exchange rates in malignant compared with benign breast lesions; b) distinct differences in enhancement characteristics between the histologic types (invasive ductal carcinoma, invasive lobular carcinoma, and ductal carcinoma in situ); and c) dependence of enhancement kinetics on the VPF/VEGF expression. The pathophysiologic basis for the differences in contrast enhancement patterns of tumors detectable by MRI is mainly due to vascular permeability, which leads to more characteristic differences than vascular density. MRI is able to subclassify malignant breast tumors due to their different angiogenetic properties.

Adult↗

Biochemical modulation of the catabolism and tissue uptake of the anticancer drug 5-fluorouracil by 5-bromovinyluracil: assessment with metabolic (19)F MR imaging.

Using chemical shift-selective (19)F magnetic resonance (MR) imaging, we investigated the biomodulating action of 5-bromovinyluracil (BVU) on the degradation of the anticancer drug 5-fluorouracil (5-FU) to its major catabolite alpha-fluoro-beta-alanine (FBAL) and the tissue uptake of 5-FU in ACI rats with transplanted Morris hepatoma. Rats in the control group (n = 7) received 200 mg/kg body weight of 5-FU intravenously, whereas the rats in the BVU group (n = 7) additionally received 30 mg/kg body weight of BVU intraperitoneally about 45 min before 5-FU injection. In each animal examination, three selective (19)F MR images were acquired sequentially after 5-FU administration with an acquisition time of 32 min each: an early 5-FU image (dominant Fourier line, 8 min p.i.) that characterized the early uptake of the drug into the various tissues, an FBAL image (dominant Fourier line, 56 min p.i.) that reflected the catabolism of the drug, and a late 5-FU image (dominant Fourier line, 78 min p.i.) that assessed the retention ("trapping") of unmetabolized 5-FU and its MR-visible anabolites. Pretreatment with BVU resulted in a highly statistical significant decrease (P < 0.001) of the FBAL signal in the liver. The marked effect of BVU on 5-FU degradation, however, improved neither the early uptake nor the retention of 5-FU in skeletal muscle and tumor tissue (P > 0.7). Moreover, our results indicate that 5-FU tumor uptake is not only dependent on the plasma concentration of unmetabolized 5-FU but is also determined by tumor-specific factors, these showing considerable variations between individual neoplasms. Magn Reson Med 42:936-943, 1999.

Animals↗

Direct detection of intratumoral 5-fluorouracil trapping using metabolic 19F MR imaging.

The effective use of 5-fluorouracil (5-FU) in cancer therapy requires the noninvasive assessment of its transport, metabolism, and retention ("trapping") in the different tissues of the organism, particularly in the tumor. We used a chemical-shift selective 19F magnetic resonance (MR) imaging technique to map selectively 5-FU and its major catabolite alpha-fluoro-beta-alanine (FBAL) in six ACI rats bearing Morris hepatoma. After i.v. administration of 200 mg/kg-bw 5-FU, three metabolic MR maps were acquired consecutively in each animal: 1) an early 5-FU image (5-37 min post-injection (p.i.); dominant Fourier line, 8 min p.i.) characterizing the early uptake of 5-FU into the various tissues; 2) an FBAL image (40-72 min p.i.; dominant Fourier line, 56 min p.i.) reflecting the catabolism of the drug; and 3) a late 5-FU image (75-107 min p.i.; dominant Fourier line, 78 min p.i.) to assess the retention of unmetabolized 5-FU and its MR-visible anabolites. In the early 5-FU maps, the drug was detected in all major organs (e.g., heart, liver, kidneys) as well as in the muscular system. The FBAL maps showed no FBAL accumulation in the hepatoma which reveals that the tumor cells have lost hepatocellular functions relevant for 5-FU catabolism. On the late 5-FU maps, a significant amount of 5-FU was detected in only one of the six Morris hepatomas. The observation in this rat verifies directly that 5-FU can be trapped in solid tumors. The images, moreover, emphasize the necessity of acquiring spatially-resolved MR data to detect metabolic tumor heterogeneity.

Animals↗

Quantitative MR temperature monitoring of high-intensity focused ultrasound therapy.

A new quantitative method has been developed for real-time mapping of temperature changes induced by high intensity focused ultrasound (HIFU). It is based on the temperature dependence of the T1 relaxation time and the equilibrium magnetization. To calibrate the temperature measurement, the functional relationship between T1 and temperature was examined in different samples of porcine muscle and fatty tissue. The method was validated by a comparison of calculated temperature maps with fiber-optic measurements in heated muscle tissue. The experiment showed that the accuracy of the MR method for temperature measurements is better than 1 degree C. Since the acquisition time of the employed MR sequence takes only 3 s per slice and the calculation of the temperature map can be performed within seconds, the imaging technique works nearly in real-time. The temperature measurement could be realized during HIFU showing no disturbances by ultrasound sonication. In comparison to other MR approaches, the advantages of the introduced method lie in a sufficient accuracy and time resolution combined with a reasonable robustness against motion as well as the feasibility for temperature monitoring in fatty tissues.

Adipose Tissue↗

Investigation of scattered radiation in 3D whole-body positron emission tomography using Monte Carlo simulations.

The correction of scattered radiation is one of the most challenging tasks in 3D positron emission tomography (PET) and knowledge about the amount of scatter and its distribution is a prerequisite for performing an accurate correction. One concern in 3D PET in contrast to 2D PET is the scatter contribution from activity outside the field-of-view (FOV) and multiple scatter. Using Monte Carlo simulations, we examined the scatter distribution for various phantoms. The simulations were performed for a whole-body PET system (ECAT EXACT HR+, Siemens/CTI) with an axial FOV of 15.5 cm and a ring diameter of 82.7 cm. With (without) interplane septa, up to one (two) out of three detected events are scattered (for a centred point source in a water-filled cylinder that nearly fills out the patient port), whereby the relative scatter fraction varies significantly with the axial position. Our results show that for an accurate scatter correction, activity as well as scattering media outside the FOV have to be taken into account. Furthermore it could be shown that there is a considerable amount of multiple scatter which has a different spatial distribution from single scatter. This means that multiple scatter cannot be corrected by simply rescaling the single scatter component.

Algorithms↗

Subsets and overrelaxation in iterative image reconstruction.

A number of iterative image reconstruction algorithms were integrated into one formula characterizing each algorithm by only two parameters: overrelaxation and number of subsets. From the formula it follows that the ordered-subsets iteration (OS-EM) is equivalent to iteration with overrelaxation, where the OS level corresponds to the overrelaxation parameter. Algorithms represented by the formula were studied with respect to speed of convergence and image characteristics. In particular, OS-EM was compared with a single-projection iteration procedure using an optimized sequence of overrelaxation parameters (HOSP) which combines rapid convergence with reduced storage requirements. As a result, OS-EM with a constant number of subsets either needed more iteration steps than HOSP or provoked additional noise, depending on the number of subsets used during iteration. OS-EM can be improved by using decreasing OS levels, imitating the decreasing overrelaxation parameters used for HOSP. The resulting OS-EM may be slightly more rapid than HOSP, due to the increasing number of projections used simultaneously.

Algorithms↗

Noninvasive determination of the arterial input function of an anticancer drug from dynamic PET scans using the population approach.

For the application of a kinetic model to PET data, it is generally necessary to obtain the arterial input function (AIF). It was the aim of the present study to introduce a method suitable for the determination of the AIF of a substance that undergoes biochemical transformation from noisy PET data: the population approach. F-18 labeled 5-fluorouracil (5-[18F]FU) was administered i.v. to eight patients suffering from liver metastases of colorectal carcinoma. Radioactivity concentrations in liver and aorta were dynamically measured with PET over 120 min. Pharmacokinetic analysis was carried out by applying a five-compartment model to individual activity-time data for the eight patients or to the mean activity-time data among the eight patients. The mean values of all parameters describing 5-FU transport and catabolism, i.e., volumes of distribution and clearances, as well as interindividual coefficients of variation (CV) were calculated according to both approaches. With our model, we were able to separate the concentration-time course of 5-FU in plasma, i.e., the AIF, from that of its major catabolite alpha-fluoro-beta-alanine (FBAL). As far as the mean parameter estimates are concerned, the differences between both approaches are not significant. For the liver data, the CV's are almost the same for both approaches. For the parameters concerning the aorta, however, there is a decrease in the CV's by using the population approach. For example, the CV of the central distribution volume of 5-FU was 30% for the individual approach and 18% for the population approach. With the population approach, it is possible to determine the AIF of drugs that undergo metabolic conversion, such as anticancer drugs, from the abdominal aorta visualized on PET images. The population approach helps to overcome noise in individual data. Since no measurements are needed in addition to the PET examination, the suggested method helps to reduce risk and pain for the patients as well as cost and thus facilitates large scale patient studies.

Adenocarcinoma↗

Regional blood flow, capillary permeability, and compartmental volumes: measurement with dynamic CT--initial experience.

Sequential computed tomographic scanning was performed in patients with neck tumors after contrast material administration. For data analysis, a pharmacokinetic two-compartment model was employed that takes into account both capillary blood supply and bidirectional diffusion of the contrast agent across the capillary wall. This approach offers the possibility to quantitatively characterize tissue microcirculation with regional blood flow, capillary permeability, and relative compartmental volumes.

Blood Volume↗

[Reduction of radiation exposure in PET examinations by data acquisition in the 3D mode].

AIM: Modern volume PET systems offer the possibility to measure without the shadowing effect of interplane septa (2D mode) and thus to detect coincident events between detectors on distant rings (3D mode). It was the aim of the present paper to characterize the count rate behaviour of a latest-generation whole-body PET system in the 2D and 3D mode as well as to discuss the consequences for the radiation hygiene of PET examinations with 2-[F-18]-fluoro-2-deoxyglucose (18-F-FDG). METHODS: All experiments were performed with the PET system ECAT EXACT HR+. For 2D data acquisition, a collimator of thin tungsten septa was positioned in the field-of-view. The count rate behaviour of the scanner was evaluated in the 2D and 3D mode over a wide range of F-18 activity concentrations following the NEMA protocol. Moreover, PET images of the EEC whole-body phantom with different inserts were acquired in the 2D and 3D mode over a period of 15 min each. For the 3D measurement, the activity concentrations of the F-18 solution were only half of those used for the 2D measurement. RESULTS: For the circular NEMA phantom (phi = 19.4 cm, length = 19.0 cm), we observed an increase of the system sensitivity in the 3D mode by a factor of about 5 with respect to the 2D mode (27.7 vs. 5.7 cps/Bq/ml). The evaluation of the activity distributions of the EEC phantom reconstructed from the 3D data set revealed a superior image quality compared to the corresponding 2D images despite the fact that the activity concentrations were only half as high. CONCLUSIONS: By using the 3D data acquisition mode, it is possible to markedly reduce the amount of activity to be applied to the patient and nevertheless to improve image quality. In our experience, it is sufficient to administer an activity of 150-200 MBq for whole-body examinations with F-18-FDG, which results in an effective equivalent dose of 3 or 4 mSv, respectively.

Environmental Exposure↗