P-31 spectroscopy study of response of superficial human tumors to therapy.

Studies were performed to characterize phosphorus-31 magnetic resonance (MR) spectra obtained from 10 superficial human tumors outside the brain and to determine whether P-31 MR spectroscopy could allow detection of a response to therapy before a change in tumor size was measured. The ratio of phosphomonoester to adenosine triphosphate peak intensities (PME/ATP) was unusually large in all tumors studied. The average PME/ATP in lymphomas (1.8 +/- 0.5) was greater than in nonlymphoma cancers (1.1 +/- 0.15). The average PME/ATP for all tumors studied (1.4 +/- 0.5) was much greater than that of underlying skeletal muscle (0.23 +/- .09). Eight of the tumors were studied before and after therapy. Responders were distinguished from nonresponders on the basis of changes in tumor size. PME/ATP decreased during therapy in three lymphomas that responded to therapy. In an adenocarcinoma and Ewing sarcoma that did not respond to therapy, PME/ATP increased. PME/ATP remained constant in two squamous cell carcinomas that responded to therapy and decreased in one squamous cell carcinoma that decreased in size by 40% but was classified as a nonresponder. Changes in PME/ATP did not always parallel changes in tumor size during therapy. In two patients, a decrease in PME/ATP preceded a decrease in tumor size. In four patients, PME/ATP increased transiently during periods when tumor size remained constant.

Adenosine Triphosphate↗

Comparison of 31P MRS and 1H MRI at 1.5 and 2.0 T.

The goals of this study were to compare 31P magnetic resonance spectroscopy (MRS) and 1H magnetic resonance imaging (MRI) of human subjects and phantoms at 1.5 and 2.0 T. The 31P signal-to-noise (S/N) ratios in phantom standards and in localized volumes in human brain and liver were compared at 1.5 and 2.0 T. In addition, T1 values for 31P resonances in human brain, 31P linewidths of metabolites in human brain and liver, 1H S/N in a phantom standard, and MR image quality in human head and body were compared at the two field strengths. The results of our study showed that at the higher strength field, (1) in vivo 31P MRS studies benefited from up to 32% improvement in S/N; (2) in vivo 31P MRS studies also benefited from increased spectral dispersion; (3) the quality of MR head images remained comparable; and (4) body images showed some decrease in image quality due to increased chemical shift, and flow and motion artifacts.

Brain↗

Spin echo 31P spectroscopic imaging in the human brain.

Spectroscopic imaging of phosphorus metabolites in the human brain has been carried out with two data acquisition methods: by observation of the free induction decay (FID) signal and by a short spin echo sequence. The resultant spectral images and spatially resolved spectra are compared. Spin echo observation is found to provide spectra of superior quality, and by suitably selecting the sequence timing, no significant increase in T2 losses, as compared with the FID method, is encountered. 31P images with approximately 3.5 cm spatial resolution are obtained within times of 37 min at 2.0 T field strength.

Brain↗

Computer modeling of surface coil sensitivity.

A simple model is presented for the calculation of relative signal-to-noise (S/N) ratios of coils of different sizes and configurations when applied to in vivo MRS. Axial symmetry is assumed, which enables rather simple expressions to be used for the calculation of coil loading by the tissue. The model is calibrated to experiments through measurement of the loaded and unloaded coil Q's. Applications of the model demonstrate that for small, superficial regions of interest (ROI), small surface coils can provide a S/N much improved over that of a larger coil. However, for very deep ROIs, larger coils or coils producing uniform B1 provide improved S/N.

Computer Simulation↗

Non-invasive quantitation of human liver metabolites using image-guided 31P magnetic resonance spectroscopy.

Phosphorus-containing metabolites in normal human liver have been quantitated non-invasively with 31P magnetic resonance spectroscopy using surface coils. The location of the volume of interest (VOI) was defined by 1H magnetic resonance imaging. Subsequently, a modified three-dimensional localization technique (ISIS) was used to acquire 31P magnetic resonance spectra from the VOI. To account for partial saturation produced by rapid signal averaging, the spin/lattice relaxation times (T1) of all hepatic phosphorus resonances were measured. The corrected resonance integrals were used to derive absolute molar concentrations for the following hepatic metabolites (mmol/kg wet weight): ATP, 2.0; inorganic phosphate, 2.1; phosphodiesters, 5.4; and phosphomonoesters, 0.9. These values are compared with previously reported values for humans using freeze-clamping techniques, and provide a basis for comparison with studies of hepatic disease in this laboratory.

Adenosine Triphosphate↗

Image-guided 31P magnetic resonance spectroscopy of normal and transplanted human kidneys.

Image-guided 31-phosphorus magnetic resonance spectroscopy (MRS) was used to obtain spatially localized 31P spectra of good quality from healthy normal human kidneys and from well-functioning renal allografts. A surface coil of 14 cm diameter was used for acquiring phosphorus signals solely from a volume-of-interest located within the kidney. To determine the effects of kidney transplantation on renal metabolism, patients with well functioning allografts were studied. Little or no phosphocreatine in all spectra verifies the absence of muscle contamination, and is consistent with proper volume localization. The intensity ratio of phosphomonoesters (PME) to adenosine triphosphate (ATP) resonances in transplanted kidneys (PME/ATP = 1.1 +/- 0.4) was slightly elevated (P = 0.2) compared to that of healthy normal kidneys (PME/ATP = 0.8 +/- 0.3). The inorganic phosphate (Pi) to ATP ratio was similar in the two groups (Pi/ATP = 1.1 +/- 0.1 in transplanted kidneys vs. 1.2 +/- 0.6 in normal kidneys). Acid/base status, as evidenced from the chemical shift of Pi, was the same in both normal controls and transplanted kidneys. Despite the practical problems produced by organ depth, respiratory movement, and tissue heterogeneity, these results demonstrate that image-guided 31P MR spectra can reliably be obtained from human kidneys.

Adult↗

P-31 MR spectroscopy of normal human brain and brain tumors.

Image-guided phosphorus-31 magnetic resonance (MR)-localized image-selected in vivo spectroscopy was performed on normal human brain and brain tumors. Peak area ratios, absolute molar concentrations of metabolites, and pH were determined. T1 values in normal brain were measured. The most important finding was that the metabolite concentrations detectable with MR spectroscopy in brain tumors were reduced from 20% to 70%. Phosphomonoesters, phosphodiesters, and phosphocreatine (PCr) showed the greatest decreases, while inorganic phosphate (Pi) showed the least change. The PCr-Pi ratio was significantly reduced in tumors. The pH of brain tumors (7.12 +/- 0.03) was more alkaline than that of normal brain (6.99 +/- 0.01). The authors conclude that the metabolite concentrations and pH in human brain tumors differ significantly from those in normal brain. These differences may be ultimately useful in characterizing tumors in man.

Adolescent↗

Early metabolic response to tumor necrosis factor in mouse sarcoma: a phosphorus-31 nuclear magnetic resonance study.

To investigate the effects of recombinant human tumor necrosis factor alpha (rHuTNF-alpha) on high-energy phosphate metabolism of cancer cells, 31P nuclear magnetic resonance (NMR) studies were performed on a murine methylcholanthrene-induced sarcoma. Injection of 15 micrograms of rHuTNF-alpha caused progressive depletion of ATP and phosphocreatine within 90 min, together with an increase in inorganic phosphate. Metabolic changes were correlated with the early histological appearance of thrombosis and hemorrhage. A spatially localized NMR technique demonstrated that these changes were specific for the tumor. Acute ischemia of the tumor produced similar metabolic changes; thus the metabolic effects of rHuTNF-alpha could be due to either a primary action on tumor biochemistry or a secondary action produced by ischemia. These findings indicate that rHuTNF-alpha has a very rapid onset of action, which can be detected by 31P NMR. Furthermore, the results suggest that 31P NMR spectroscopy will be extremely useful for detecting early biochemical changes produced by rHuTNF-alpha or other treatments in animal and human cancers.

Adenosine Triphosphate↗

Computer simulation of MRS localization techniques: an analysis of ISIS.

Computer simulations were used to evaluate the ISIS localization technique as implemented with both head and surface coils. The effects of chemical shift, B1 inhomogeneity, repetition time, T2 relaxation, a postacquisition saturation pulse, and a B1 insensitive observation pulse were examined. Integrals of ISIS signals over the sample volume showed that significant signal loss from the volume of interest (VOI) and contamination from outside the VOI can occur for both head and surface coil ISIS experiments. The results showed that the saturation pulse, order of the various ISIS acquisitions, and repetition time affect contamination but not signal loss. In addition, short T2 and high RF power can combine synergistically to degrade the selective inversion pulses, causing further contamination and signal loss.

Computer Simulation↗

Improvement of the rotating frame experiment by detection of residual Z magnetization: a 31P MRS study of metabolite levels in a Meth-A sarcoma.

The radio frequency field (B1) gradient of a surface coil can be used to obtain spectra from a series of sample regions which experience different B1 field strengths. We previously reported that the sensitivity of this method, known as the surface coil rotating frame experiment (SCRFE), can be enhanced by applying a composite pulse immediately after signal acquisition to sample residual Z magnetization which is normally undetected. Initially this modified SCRFE was used to obtain spatially resolved spectra across a B1 gradient of a factor of 2.5. Here we demonstrate the extension of this method to map phosphorylated metabolites across a B1 gradient of a factor of close to 5. Computer simulations were used to evaluate the performance of the composite pulse, and to assist in analyzing the data. The method was used to obtain 31P spectra in vivo from various tissue layers within and beneath a murine Meth-A tumor. The spectra differentiated between metabolite levels in tumor tissue and underlying skeletal muscle. Metabolic heterogeneity within the tumor itself was also evident.

Animals↗

Detection of motion using B1 gradients.

An NMR method which makes use of a radiofrequency (RF) field gradient to detect diffusion, perfusion, or flow is demonstrated. The technique is analogous to the detection of motion using pulsed B0 gradients. The simplest form of the experiment is as follows: A spatially imhomogeneous RF field generated by a surface coil produces dispersal of magnetization in the Y Z plane. After a delay, the RF field is applied within reversed phase to restore polarization along +Z, which is then sampled using an observe pulse or pulse sequence. If molecular motion occurs during the delay period the amplitude of Z magnetization will be reduced. The lengths of the RF pulses and the delay period are varied so that the effects of relaxation, flow, and diffusion or perfusion can be distinguished. The present study demonstrates the use of this method to detect slow fluid flow. Advantages of this method include the availability of large RF gradients, and the avoidance of eddy currents. It is suggested that the method may have application to the study of perfusion and flow in vivo.

Diffusion↗

Nuclear magnetic resonance imaging-guided phosphorus-31 spectroscopy of the human heart.

Phosphorus-31 nuclear magnetic resonance spectroscopy can determine the status of high energy phosphates in vivo. However, its application to human cardiac studies requires precise spatial localization without significant contamination from other tissues. Using image-selected in-vivo spectroscopy (ISIS), a technique that allows three-dimensional localization of the volume of interest, 12 subjects were studied to determine the feasibility and reproducibility of phosphorus-31 spectroscopy of the human heart. Nuclear magnetic resonance imaging was performed using a commercial 1.5 tesla system to define the volume of interest. Phosphorus-31 spectra were obtained from the septum and anteroapical region of the left ventricle in 10 studies. Relative peak heights and areas were determined for high energy phosphates. The mean phosphocreatine to adenosine triphosphate ratio was 1.33 +/- 0.19 by height analysis and 1.23 +/- 0.27 by area analysis. Duplicate measurements in four subjects showed a reproducibility of less than or equal to 10% in three of the subjects. All spectra showed significant signal contribution from the 2,3 diphosphoglycerate in chamber red cells without evidence of skeletal muscle contamination. These results demonstrate the feasibility of image-guided phosphorus-31 spectroscopy for human cardiac studies and indicate the potential of this technique to study metabolic disturbances in human myocardial disease.

Adenosine Triphosphate↗

Application of image-guided surface coil P-31 MR spectroscopy to human liver, heart, and kidney.

Localized phosphorus-31 magnetic resonance (MR) spectroscopy in humans has previously been accomplished with surface coils by means of depth-resolved surface coil spectroscopy or rotating frame experiments, in which the extent of tissue sampled critically depends on surface coil placement. The authors' goal was to modify the surface coil image-selected in vivo spectroscopy (ISIS) experiment to accomplish three-dimensional volume selection through application of selective pulses in the presence of B0 gradients. Advantages of ISIS include the ability to use proton images to define the volume of interest (VOI) and reduced dependence on exact positioning of the surface coil. However, rapid replication of the surface coil ISIS experiment can cause spectral contamination from signals originating outside the VOI. A modified version of the ISIS experiment was developed to alleviate contamination under conditions of rapid replication. Applications of localized P-31 MR spectroscopy for observation of high-energy phosphorus metabolites are presented in human liver, heart, and transplanted and normal kidney.

Computer Simulation↗

Localization of phosphorus metabolites and sodium ions in the rat kidney.

Relative amounts of phosphorus-containing metabolites and sodium ions present in different regions of the in vivo rat kidney were obtained using a surface-coil probe and recently developed NMR rotating-frame methods. During altered physiologic states, changes in distribution of metabolites and sodium ions within the kidney were identified in one-dimensional metabolite maps. This technique may have important applications to disorders commonly found in clinical medicine.

Acidosis↗

A single acquisition localization technique.

A method is demonstrated for detection of magnetization from a selected region within the sensitive volume of a surface coil in a single acquisition. Composite pulses are described which eliminate signals from regions where magnetization is rotated 270 and 450 degrees. There is a loss of 1.3% or less of signal from regions where magnetization is rotated 90 degrees.

Animals↗

Radioimmunotherapy of human lymphoma in athymic, nude mice as monitored by 31P nuclear magnetic resonance.

Human B cell lymphoma (Raji) growing in athymic, nude mice has been successfully treated with a single pulse dose of 131I-labeled monoclonal antibody (Lym-1) specific for this tumor. Sequential in vivo measurements of phosphate metabolites in the tumors by 31P surface coil nuclear magnetic resonance showed a significant initial decrease of phosphocreatine following radioimmunotherapy. Diminution of relative ATP to Pi peak area ratio suggesting tissue damage occurred within 3-4 days. The contribution from metabolites resonating at ca 3.8 ppm (putative sugar phosphate region) increased. There was no significant change in pH either as a function of tumor volume or treatment. The sequence of alterations of nuclear magnetic resonance spectra from tumors of treated mice were strikingly different from sequential nuclear magnetic resonance spectra obtained from tumors of control mice. These observations lead us to conclude that 31P surface coil nuclear magnetic resonance is a promising non-invasive method for assessing and predicting the efficacy of radioimmunotherapy. Further spatial discrimination of the region of tissue observed by the surface coil nuclear magnetic resonance experiment is under exploration in an effort to increase the utility of these methods.

Adenosine Triphosphate↗

Surface coil phosphorus-31 nuclear magnetic resonance studies of the intact eye.

The feasibility of employing the surface coil probe technique for the non-invasive study of ocular tissue metabolism by phosphorus-31 nuclear magnetic resonance spectroscopy (31P NMR) in enucleated bovine, rabbit, human and rat globes is demonstrated. An assessment of individual phosphorus-metabolite contributions from ocular tissues, including the cornea, lens and iris, to the overall 31P NMR spectrum (NMR spectral acquisition parameters optimized for the lens region of the globe) was accomplished through the combination of surgical ablation and difference spectroscopy. The NMR measurements also provided tissue pH values for the lens and cornea. The strengths and limitations of the surface coil NMR method, which is particularly appropriate for in vivo metabolic studies of ocular tissues such as the lens, are discussed.

Adenosine Triphosphate↗

Longitudinal (T1) relaxation times of phosphorus metabolites in the bovine and rabbit lens.

Longitudinal (T1) magnetic relaxation times for the major phosphorus-containing metabolites present in the bovine and rabbit lens under organ culture conditions and in the bovine and rabbit globe have been determined. Significant differences in T1 for the major phosphorus metabolites in each case are observed, as well as for the same metabolite in the two species examined. Species-dependent lens hydration may account, in part, for these differences. Because of the requirement for rapid repetitive pulsing for the attainment of optimum signal collection efficiency by the Fourier transform nuclear magnetic resonance method, significant differential saturation of metabolite resonance intensities occurs in circumstances where appreciable differences in T1 relaxation times are present, which, unless corrected, leads to erroneous determinations of relative metabolite levels. The net effect of assessing relative metabolite levels in terms of the percentage of total phosphate signal, without a correction for T1 discrimination, is to underestimate metabolites with a long T1 (sugar phosphates) and overestimate those metabolites with a short T1 (ATP). Individual metabolite T1 discrimination factors are calculated from integrated areas of spectra acquired using short and long repetition times as well as from metabolite T1 values. They are then employed, for the first time, for the correction of 31P-NMR spectra of bovine and rabbit lenses. Corrected spectra provide relative metabolite levels for lenticular ATP which are in excellent agreement with values determined by chemical and enzymatic assays.

Animals↗