Search PubMed⌕ Search

Biomedical subjects

G B Matson

Publications and source records attributed to G B Matson.

At least 37 records · Page 2Linked to original sources

Proton magnetic resonance spectroscopic imaging in patients with frontal lobe epilepsy.

Proton magnetic resonance spectroscopic imaging (1H MRSI) has demonstrated decreased N-acetyl compounds (NA) in the epileptogenic hippocampus in patients with temporal lobe epilepsy. We studied 8 patients with frontal lobe epilepsy and found mean NA/creatine (Cr) in the epileptogenic frontal lobe decreased by 27% compared with that of the contralateral homologous region (1.81 +/- 0.36 vs 2.49 +/- 0.60, p < 0.008). In every patient, NA/Cr was decreased in the epileptogenic region by at least 5%. These findings suggest that 1H MRSI may be useful in the presurgical evaluation of patients with frontal lobe epilepsy.

Aspartic Acid↗

Phosphorus magnetic resonance spectroscopic imaging in patients with frontal lobe epilepsy.

Phosphorus magnetic resonance spectroscopic imaging has previously demonstrated localized metabolic abnormalities within the epileptogenic region in patients with temporal lobe epilepsy, including alkalosis, increased inorganic phosphate level, and decreased phosphomonoester levels. We studied 8 patients with frontal lobe epilepsy, finding interictal alkalosis in the epileptogenic region compared to the contralateral frontal lobe in all patients (7.10 +/- 0.05 vs 7.00 +/- 0.06, p < 0.001). Seven patients exhibited decreased phosphomonoester levels in the epileptogenic frontal lobe compared to the contralateral frontal lobe (16.0 +/- 6.0 vs 23.0 +/- 4.0, p < 0.01). In contrast to findings in temporal lobe epilepsy, inorganic phosphate level was not increased in the epileptogenic region. Based on values derived from normal control subjects, 5 patients had elevated pH in the seizure focus and 2 patients had decreased phosphomonoesters while none had abnormalities in the contralateral frontal lobe. These data suggest that magnetic resonance spectroscopy will be useful in the presurgical evaluation of patients with frontal lobe epilepsy.

Adolescent↗

Biochemical alterations in multiple sclerosis lesions and normal-appearing white matter detected by in vivo 31P and 1H spectroscopic imaging.

The goals of the current study were threefold: first, to confirm previous single volume proton (1H) magnetic resonance spectroscopy results of reduced N-acetyl aspartate (NAA, a putative marker of neurons) in multiple sclerosis (MS) white matter lesions using multiple volume 1H magnetic resonance spectroscopic imaging (MRSI); second, to measure the phospholipid metabolites phosphomonoesters and phosphodiesters in such lesions using phosphorus (31P) MRSI; and third, to test the hypothesis that biochemical changes occur in the normal-appearing (on spin echo T2-weighted magnetic resonance images) white matter in patients with MS. Thirteen subjects with clinically definite MS were studied with both 1H and 31P MRSI, and 19 controls were studied with either 1H MRSI, 31P MRSI, or both. MS lesion, MS normal-appearing white matter, and region-matched control spectra from the centrum semiovale were analyzed. The major findings of this study were that in both white matter lesions and normal-appearing white matter in patients with MS, the metabolite ratio NAA/creatine and the total 31P peak integrals were significantly reduced compared with controls. In addition, in MS lesions NAA/choline and phosphodiesters/total 31P were significantly reduced compared with controls, and in MS normal-appearing white matter there was a trend for NAA/choline to be reduced compared with controls. In normal-appearing white matter in patients with MS, total creatine and phosphocreatine were significantly increased compared to controls, as detected with both 1H (total creatine peak integrals) and 31P (phosphocreatine/total 31P) MRSI techniques. These results suggest reduced neuronal density and altered phospholipid metabolites in white matter lesions in patients with MS.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

In vivo detection of myelin phospholipids in multiple sclerosis with phosphorus magnetic resonance spectroscopic imaging.

The goal of this study was to investigate myelin phospholipids in vivo in multiple sclerosis lesions and normal-appearing white matter by evaluating the spectral broad component from phosphorus 31 magnetic resonance spectroscopic imaging data. The phospholipid broad component was reduced nearly 35% (p < 0.001) in both lesions and in normal-appearing white matter in multiple sclerosis subjects compared to control subjects, suggesting reduced myelin phospholipid concentration or altered relaxation times.

Adult↗

Reduced phase encoding in spectroscopic imaging.

The effect of different spatial-encoding (k-space) sampling distributions are evaluated for magnetic resonance spectroscopic imaging (MRSI) using Fourier reconstruction. Previously, most MRSI studies have used square or cubic k-space functions, symmetrically distributed. These studies examine the conventional k-space distribution with spherical distribution, and 1/2 k-space acquisition, using computer simulation studies of the MRSI acquisition for three spatial dimensions and experimental results. Results compare the spatial response function, Gibbs ringing effects, and signal contamination for different spatial-encoding distribution functions. Results indicate that spherical encoding, in comparison with cubic encoding, results in a modest improvement of the response function with approximately equivalent spatial resolution for the same acquisition time. For spin-echo acquired data, reduced acquisition times can readily be obtained using 1/2 k-space methods, with a concomitant reduction in signal to noise ratio.

Adenosine Triphosphate↗

An integrated program for amplitude-modulated RF pulse generation and re-mapping with shaped gradients.

Efficient generation of amplitude modulated, frequency selective RF pulses has been demonstrated by the Shinnar-Le Roux (SLR) algorithm. In the present article, we provide an overview of a relatively comprehensive computer program that includes a version of the SLR algorithm and also incorporates an algorithm for re-mapping a selective RF pulse onto a new dwell time with modulated gradients. The re-mapping may be used to reduce SAR, or to shorten the RF pulse time by increasing the gradient and RF strength in regions where the original RF pulse amplitude was low. The program includes additional useful features including a Bloch equations algorithm, and pulse scaling, to enable examination of pulse profiles under a variety of conditions such as RF inhomogeneity and even nuclear relaxation. The program, MATPULSE, was developed with the MATLAB for Windows programming language and makes extensive use of the MATLAB graphical user interface (GUI) features to generate a user-friendly interface. A number of examples are provided to illustrate the capabilities of the MATPULSE program.

Image Processing, Computer-Assisted↗

Molar quantitation of in vivo proton metabolites in human brain with 3D magnetic resonance spectroscopic imaging.

A method for molar quantitation of in vivo proton metabolites in human brain with three-dimensional (3D) proton magnetic resonance spectroscopic imaging (MRSI) is described. The method relies on comparison of brain and calibration phantom measurements, with corrections for coil loading, and spin-lattice and spin-spin relaxation times. A 3D proton MRSI pulse sequence was developed which acquires two echoes and enables acquisition of both the TMS coil loading reference phantom and proton metabolite signals from a single experiment. With the aqueous fraction (tissue water) taken into account, the calculated molar concentrations from 24 centrum semiovale white matter voxels from 4 control subjects were (mmol/l +/- SD): N-acetyl aspartate = 14.6 +/- 2.8, total creatine+phosphocreatine = 6.0 +/- 1.2, total choline = 1.9 +/- 0.4. These values are equivalent to previously reported results obtained from single volume localized proton magnetic resonance spectroscopy.

Aspartic Acid↗

Neuron loss localizes human temporal lobe epilepsy by in vivo proton magnetic resonance spectroscopic imaging.

Temporal lobe epileptogenic foci were blindly localized in 8 patients with medically refractory unilateral complex partial seizures using noninvasive in vivo proton magnetic resonance spectroscopic imaging (1H-MRSI) with 4-ml effective voxel size. The brain proton metabolite signals in 8 matched normal controls were bilaterally symmetrical within +/- 10%. The hippocampal seizure foci had 21 +/- 5% less N-acetyl aspartate signal than the contralateral hippocampal formations (p < 0.01). The focal N-acetyl aspartate reductions were consistent with pathology findings of mesial temporal sclerosis with selective neuron loss and gliosis in the surgically resected epileptogenic foci. Proton MRSI correctly localized the seizure focus in all 8 cases. By comparison, MR imaging correctly localized 7 of 8 cases and single photon emission computed tomography correctly localized 2 of 5 cases. No lactate was detected in these interictal studies. No significant changes in choline or creatine were observed. In conclusion, 1H-MRSI is a useful tool for the noninvasive clinical assessment of intractable focal epilepsy. These preliminary results suggest that 1H-MRSI can accurately localize temporal lobe epileptogenic foci.

Adult↗

Quantitation of in vivo phosphorus metabolites in human brain with magnetic resonance spectroscopic imaging (MRSI).

A method for quantitation of in vivo 31P metabolite concentrations in human brain with 31P magnetic resonance spectroscopic imaging (MRSI) is described. The method relies on comparison of brain and calibration phantom measurements, with corrections for coil loading and metabolite magnetic relaxation. Estimated metabolite concentrations for the centrum semiovale in 11 normal adults (mean +/- SD) were: phosphomonoesters = 3.0 +/- 0.7 mM, inorganic phosphate = 0.7 +/- 0.2 mM, phosphodiesters = 10.9 +/- 1.8 mM, phosphocreatine = 2.7 +/- 0.5 mM, and adenosine triphosphate = 2.9 +/- 0.3 mM. These values are similar to previous results obtained from single-volume localized spectroscopy.

Adenosine Triphosphate↗

Phosphorus-31 MR spectroscopic imaging (MRSI) of normal and pathological human brains.

The goals of this study were to evaluate 31P MR spectroscopic imaging (MRSI) for clinical studies and to survey potentially significant spatial variations of 31P metabolite signals in normal and pathological human brains. In normal brains, chemical shifts and metabolite ratios corrected for saturation were similar to previous studies using single-volume localization techniques (n = 10; pH = 7.01 +/- 0.02; PCr/Pi = 2.0 +/- 0.4; PCr/ATP = 1.4 +/- 0.2; ATP/Pi = 1.6 +/- 0.2; PCr/PDE = 0.52 +/- 0.06; PCr/PME = 1.3 +/- 0.2; [Mg2+]free = 0.26 +/- 0.02 mM.) In 17 pathological case studies, ratios of 31P metabolite signals between the pathological regions and normal-appearing (usually homologous contralateral) regions were obtained. First, in subacute and chronic infarctions (n = 9) decreased Pi (65 +/- 12%), PCr (38 +/- 6%), ATP (55 +/- 6%), PDE (47 +/- 9%), and total 31P metabolite signals (50 +/- 8%) were observed. Second, regions of decreased total 31P metabolite signals were observed in normal pressure hydrocephalus (NPH, n = 2), glioblastoma (n = 2), temporal lobe epilepsy (n = 2), and transient ischemic attacks (TIAs, n = 2). Third, alkalosis was detected in the NPH periventricular tissue, glioblastoma, epilepsy ipsilateral ictal foci, and chronic infarction regions; acidosis was detected in subacute infarction regions. Fourth, in TIAs with no MRI-detected infarction, regions consistent with transient neurological deficits were detected with decreased Pi, ATP, and total 31P metabolite signals. These results demonstrate an advantage of 31P MRSI over single-volume 31P MRS techniques in that metabolite information is derived simultaneously from multiple regions of brain, including those outside the primary pathological region of interest. These preliminary findings also suggest that abnormal metabolite distributions may be detected in regions that appear normal on MR images.

Adult↗

3D phase encoding 1H spectroscopic imaging of human brain.

A three-dimensional (3D) phase-encoding proton spectroscopic imaging method is presented for a whole body MRI/MRS system. Metabolite images at 2 T of choline, creatine, and N-acetyl aspartate (NAA) of normal brain were obtained with a spatial resolution of 1.5 cc. With PRESS volume preselection and outer volume suppression pulses, brain regions close to the skull could be studied without significant contamination by lipid and water signals.

Brain↗

Elevated lactate and alkalosis in chronic human brain infarction observed by 1H and 31P MR spectroscopic imaging.

The goal of this study was to investigate lactate and pH distributions in subacutely and chronically infarcted human brains. Magnetic resonance spectroscopic imaging (MRSI) was used to map spatial distributions of 1H and 31P metabolites in 11 nonhemorrhagic subacute to chronic cerebral infarction patients and 11 controls. All six infarcts containing lactate were alkalotic (pHi = 7.20 +/- 0.04 vs. 7.05 +/- 0.01 contralateral, p less than 0.01). This finding of elevated lactate and alkalosis in chronic infarctions does not support the presence of chronic ischemia; however, it is consistent with the presence of phagocytic cells, gliosis, altered buffering mechanisms, and/or luxury perfusion. Total 1H and 31P metabolites were markedly reduced (about 50% on average) in subacute and chronic brain infarctions (p less than 0.01), and N-acetyl aspartate (NAA) was reduced more (approximately 75%) than other metabolites (p less than 0.01). Because NAA is localized in neurons, selective NAA reduction is consistent with pathological findings of a greater loss of neurons than glial cells in chronic infarctions.

Adult↗

Hepatic cancers and their response to chemoembolization therapy. Quantitative image-guided 31P magnetic resonance spectroscopy.

RATIONALE AND OBJECTIVES: Hepatic embolization combined with intra-arterial administration of cytostatic drugs (chemoembolization) is frequently used to treat primary and metastatic cancers to the liver. Quantitative phosphorus-31 magnetic resonance spectroscopy (31P MRS) was used to assess the metabolic state of hepatic cancers and their metabolic response to chemoembolization. METHODS: Fifteen localized 31P MRS studies were performed on five patients with liver tumors. Thirteen healthy volunteers served as controls. Metabolite ratios and molar metabolite concentrations were calculated. RESULTS: Untreated hepatic tumors, relative to normal controls, showed elevated phosphomonoester/adenosine triphosphate (PME/ATP) ratios, reduced concentrations of ATP and inorganic phosphate (Pi), and normal phosphodiester (PDE) concentrations. As an acute response to chemoembolization, ATP, PME, and/or PDE concentrations diminished, whereas Pi concentrations increased or stayed relatively constant. Long-term follow-up after chemoembolization showed decreased PME/ATP and increased ATP concentrations in the absence of changes on standard magnetic resonance and computed tomographic images. CONCLUSIONS: These preliminary spectroscopic data suggest that quantitative 31P MRS can be successfully used to monitor directly metabolic response to hepatic chemoembolization.

Adenocarcinoma↗

Decreased phosphorus metabolite concentrations and alkalosis in chronic cerebral infarction.

A study was performed to determine quantitatively the alterations in phosphorus metabolite concentrations and pH in regions of the human brain damaged by chronic stroke. Image-guided phosphorus-31 magnetic resonance spectroscopy was performed on the brains of eight healthy subjects and six patients with cerebral infarction of more than 3 months duration. Phosphorus metabolite concentrations in infarcted regions were reduced 8%-67%. Significant decreases occurred in phosphomonoester (PME), phosphodiester (PDE), and adenosine triphosphate (ATP) concentrations, while inorganic phosphate (Pi) and phosphocreatine (PCr) concentrations showed smaller, nonsignificant decreases. The PCr/ATP ratio was significantly increased, while the ATP/Pi ratio was somewhat lower. The phospholipid ratio PDE/PME was also significantly increased, while the ratios of phospholipid (PME, PDE) to phosphate (PCR, Pi) metabolites were significantly decreased. The pH of the infarcted region indicated significantly more alkalinity than in the normal brain. The results suggest that chronic stroke is associated with significant changes in brain metabolite concentrations and pH that are different from those reported for other brain diseases.

Adenosine Triphosphate↗

Human brain infarction: proton MR spectroscopy.

Two-dimensional proton magnetic resonance (MR) spectroscopic imaging studies were performed of the distributions of the major hydrogen-1 metabolites of choline, creatine, N-acetyl aspartate (NAA) and lactate in normal (n = 6) and subacutely to chronically infarcted (n = 10) human brain. The two dimensions of phase encoding were applied over a 20-mm-thick section of brain tissue that had been selected with a double spin-echo localization method. Normal brain showed bilaterally symmetric metabolite distributions and no detectable lactate. Nine of 10 studies of brain infarction showed substantial decreases in NAA, creatine, and choline in the infarcted area compared with control areas; averaged for all studies, the decreases were 77% +/- 8, 63% +/- 11, and 54% +/- 12, respectively (mean +/- standard error). The decreased metabolite concentrations are probably due primarily to diminished cell density in the infarct. The decrease in NAA was larger than the decreases in choline and creatine. Findings in all of the studies showed lactate in the infarcted tissue and/or ventricles. The continued presence of lactate in the infarct indicates increased anaerobic glycolysis due to ischemia or other factors.

Adult↗

In vivo 31P-NMR spectroscopy of right ventricle in pigs.

The energy metabolism of the right ventricle (RV) in vivo has been largely unexplored. The goal of this study was to develop and implement techniques for in vivo 31P nuclear magnetic resonance (NMR) spectroscopy of the RV free wall. A two-turn, crossover-design elliptical surface coil was constructed to provide high sensitivity across the thin RV wall but minimal sensitivity in the blood-filled RV cavity. In 36 open-chest, anesthetized pigs, 31P spectroscopy of the RV free wall was performed with this coil at a field strength of 2 Tesla. Spectra were obtained from 800 acquisitions in 24 min with an average signal-to-noise ratio of 13.2 for phosphocreatine (PCr). The PCr-to-ATP (PCr/ATP) ratio of porcine RV was 1.42 +/- 0.05 (mean +/- SE), uncorrected for saturation at a repetition time of 1.8 s. With the use of literature values of the time constant of longitudinal relaxation (T1) to correct for partial saturation, the RV PCr/ATP was estimated to lie between 1.7 and 2.3. Decreased RV PCr/ATP was observed during RV ischemia and pressure overload. Thus in vivo 31P spectroscopy of the RV is readily accomplished with an appropriate surface coil and can provide new information about RV energy metabolism.

Adenosine Triphosphate↗

Lateralization of human focal epilepsy by 31P magnetic resonance spectroscopic imaging.

We attempted to lateralize the epileptogenic focus (seven temporal lobe hippocampal foci, one frontal lobe focus) in medically refractory unilateral complex partial seizures, using noninvasive 31P magnetic resonance spectroscopic imaging (MRSI) blindly and interictally to compare hippocampal or frontal regions. The seizure foci were more alkaline (intracellular pH = 7.17 +/- 0.03) compared with the contralateral region (7.06 +/- 0.02, p < 0.01) in all eight cases; the inorganic phosphate was relatively increased (240 +/- 50% of contralateral, seven of eight cases, p < 0.01); and phosphomonoesters were relatively reduced (68 +/- 9% of contralateral, seven of eight cases, p < 0.01). Other phosphorus metabolites were symmetric (+/- 10%). 31P MRSI correctly lateralized the seizure focus in all eight cases. By comparison, imaging correctly lateralized four cases and SPECT, two cases. In conclusion, 31P MRSI is a useful tool for the noninvasive clinical assessment of focal epilepsy and can accurately lateralize the epileptogenic focus.

Adult↗

31P MRS of myocardial inorganic phosphate using radiofrequency gradient echoes.

Determination of the chemical shift and integral of the myocardial intracellular inorganic phosphate (Pi) resonance by 31P magnetic resonance spectroscopy (MRS) is often precluded due to a large overlapping signal from 2,3-diphosphoglycerate (2,3-DPG) from chamber and myocardial blood. This report demonstrates the use of radiofrequency (RF) magnetic field gradient echoes (RFGE) to eliminate signals from 2,3-DPG in flowing blood, while retaining signals from intracellular myocardial Pi, ATP, and phosphocreatine (PCr). The ECG-triggered 31P spectra were acquired from the myocardium of open chest pigs using a Philips Gyroscan 2-T magnetic resonance spectrometer. A 2.5-cm-diameter surface coil attached to the myocardium was used to provide the RF gradient as well as for excitation and detection of signals. Optimal performance of the RFGE pulse sequence was obtained when the RF gradient pulses were centered at peak diastole or peak systole. Under these conditions, 2,3-DPG signals were completely suppressed, and sensitivity was usually sufficient to allow detection of a well-resolved Pi signal. Myocardial pH determined from RFGE experiments was 7.16 +/- 0.10, and the ratio of the integrals of the Pi and ATP resonances (Pi/ATP) was 0.24. The mean signal-to-noise ratio (S/N) for PCr in control spectra acquired in 4 min was 19/1, while the mean S/N for PCr in RFGE-edited spectra acquired in 15 min was 11/1, demonstrating that the present implementation of the RFGE method results in significant loss in sensitivity. These experiments demonstrate that RFGE-editing allows accurate determination of the chemical shift and integral of the Pi resonance in blood-perfused myocardium in situ.

2,3-Diphosphoglycerate↗