Search PubMed⌕ Search

Biomedical subjects

Francesc Borrull

Publications and source records attributed to Francesc Borrull.

25 records · Page 2Linked to original sources

On-line solid-phase extraction with molecularly imprinted polymers to selectively extract substituted 4-chlorophenols and 4-nitrophenol from water.

Three polymers have been synthesised using 4-chlorophenol (4-CP) as the template, following different protocols (non-covalent and semi-covalent) and using different functional co-monomers, 4-vinylpyridine (4-VP) and methacrylic acid (MAA). The polymers were evaluated to check their selectivity as molecularly imprinted polymers (MIPs) in solid-phase extraction (SPE) coupled on-line to liquid chromatography. The solid-phase extraction procedure using MIPs (MISPE), including the clean-up step to remove any interferences, was optimised. The 4-VP non-covalent polymer was the only one which showed a clear imprint effect. This MIP also showed cross-reactivity for the 4-chloro-substituted phenols and for 4-nitrophenol (4-NP) from a mixture containing the 11 priority EPA (Environmental Protection Agency) phenolic compounds and 4-chlorophenol. The MIP was applied to selectively extract the 4-chloro-substituted compounds and 4-NP from river water samples.

Chlorophenols↗

Using second-order calibration to identify and quantify aromatic sulfonates in water by high-performance liquid chromatography in the presence of coeluting interferences.

We used the Generalized Rank Annihilation Method (GRAM), a second-order calibration method, to quantify aromatic sulfonates in water with high-performance liquid chromatography (HPLC) when interferences coeluted with the analytes of interest. With GRAM, we can quantify in only two chromatographic analyses, one for a calibration sample and one for the unknown sample. The calculated concentrations were not statistically different to those obtained when the chromatographic separation of the unknown sample was modified in order to completely separate the analyte from the interferences before univariate calibration. With GRAM, the concentrations are determined much more quickly because a complete resolution is not required.

Calibration↗

Improving sensitivity by large-volume sample stacking using the electroosmotic flow pump to analyze some nonsteroidal anti-inflammatory drugs by capillary electrophoresis in water samples.

Large-volume sample stacking using the electroosmotic flow (EOF) pump (LVSEP) has been used to analyze some nonsteroidal anti-inflammatory drugs (NSAIDs) in water samples. With methanol as the run buffer solvent to suppress the EOF, sensitivity was enhanced by 80-100-fold. The sample for the analysis of real water sample was pretreated by solid-phase extraction (SPE). When the method was based on off-line SPE-LVSEP-CE, sensitivity improved by as much as 1000 times.

Anti-Inflammatory Agents, Non-Steroidal↗

Non-covalent and semi-covalent molecularly imprinted polymers for selective on-line solid-phase extraction of 4-nitrophenol from water samples.

Two molecularly imprinted polymers (MIPs) have been synthesised for the selective extraction of 4-nitrophenol (4-NP) from water samples. One polymer was synthesised via a non-covalent approach and the other via a semi-covalent approach. The selectivity of the polymers for 4-NP was evaluated when these polymers were applied in on-line solid-phase extraction (MISPE) coupled to reversed-phase HPLC. The MISPE conditions for both MIPs were optimised and a clean-up step was included to eliminate non-specific interactions. Differences between the two MIPs were observed with the non-covalent MIP being the more selective of the two, whereas the recoveries were slightly higher for the semi-covalent MIP. The performance of the imprinted polymers in the MISPE of real water samples was also evaluated.

Chromatography, Liquid↗

Determination of ciprofloxacin, enrofloxacin and flumequine in pig plasma samples by capillary isotachophoresis--capillary zone electrophoresis.

Quinolones are a group of synthetic antibiotics that are widely used in veterinary medicine. Their residues may remain in tissues, milk, etc. intended for human consumption. The European Union fixes the maximum residue limits (MRLs) of veterinary medicinal products in foodstuffs of animal origin. Analytical methods are therefore needed to determine them in biological samples. In this study, we describe capillary isotachophoresis-capillary zone electrophoresis (ITP-CZE) to analyze three quinolones, enrofloxacin (ENR), ciprofloxacin (CPR) and flumequine (FLU), in pig plasma samples. We used solid-phase extraction with Oasis HLB cartridges as a sample pretreatment clean-up step. Capillary zone electrophoresis (CZE) requires low amounts of sample and is not as sensitive as one would wish. ITP-CZE is an easy way to increase the sample loadability and sensitivity. With this system sensitivity increases 40-fold. The detection limits for CPR, ENR and FLU were 70, 85 and 50 microg l(-1), respectively, which were lower than their MRLs in different kinds of samples. This method is simple and sensitive, and is therefore an alternative tool to the existing HPLC methods for analyzing the residuals of these quinolones in biological samples.

Animals↗

Using nonaqueous capillary electrophoresis to analyze several quinolones in pig kidney samples.

We show the potential of nonaqueous capillary electrophoresis (NACE) for analyzing enrofloxacin (ENR), ciprofloxacin (CPR), danofloxacin (DAN), difloxacin (DIF), marbofloxacin (MAR), flumequine (FLU), and oxolinic acid (OXA) in pig kidney samples. We have studied the effects of parameters such as the composition of the organic media, the choice of electrolyte, the pH* of the background electrolyte (BGE), the addition of modifiers, and the reversal of electroosmotic flow. Separation was good with 20 mM ammonium acetate, 0.004% polycation hexadimethrine bromide (HDB), and 4% acetic acid (pH* 5.4) in methanol/acetonitrile (50:50 v/v) medium. We used a quick and simple sample preparation method, hydrochloric acid as an extractant and solid-phase extraction (SPE) with Baker C18 cartridges as the cleanup step. Recoveries for all quinolones were over 80%.

Animals↗

Isotachophoretic focusing and mass spectrometry detection as tools for improving the determination of aromatic sulfonates in capillary electrophoresis.

We explored isotachophoresis-capillary zone electrophoresis (ITP-CZE) with diode array detection on a single capillary to find out how to increase the injection volume and decrease the detection limits of aromatic sulfonates in CZE. The ITP was performed by applying a negative voltage in conjunction with hydrodynamic backpressure programming, and the terminating buffer was removed before the CZE separation, which resulted in highly sensitive determinations. The ITP increased the signal response of conventional hydrodynamic injection by a factor of 100, whereas the separation efficiency was unaffected. The limits of detection of the method were between 3 and 5 nugL(-1). The method was successfully used to determine these compounds in water samples. Experimental conditions for capillary electrophoresis-mass spectrometry were optimized and applied to determine aromatic sulfonates in water samples. These techniques enables the 2-naphthalenesulfonate to be determined in water samples.

Arylsulfonates↗