Search PubMed⌕ Search

Biomedical subjects

Francesc Borrull

Publications and source records attributed to Francesc Borrull.

At least 19 recordsLinked to original sources

Different sample stacking strategies to analyse some nonsteroidal anti-inflammatory drugs by micellar electrokinetic capillary chromatography in mineral waters.

Three on-column preconcentration techniques were compared to analyse a group of nonsteroidal anti-inflammatory drugs (NSAIDs) using micellar electrokinetic capillary chromatography (MEKC) under pH-suppressed electroosmotic flow (EOF) in water samples. The analysed drugs were ibuprofen, fenoprofen, naproxen, ketoprofen, and diclofenac sodium. The micellar background electrolyte (BGE) solution was formed by 75 mM sodium dodecyl sulfate (SDS), 40% (v/v) acetonitrile, and 25 mM sodium phosphate at pH 2.5. When this BGE solution was used the applied voltage was reversed, -10 kV, and the drugs were separated within 20 min. The on-column preconcentration modes, characterised all of them for the sample matrix removal out of the capillary by itself under a reverse potential at the same time as the EOF was reduced, were stacking with reverse migrating micelles (SRMM), stacking with reverse migrating micelles-anion selective exhaustive injection (SRMM-ASEI), and field-enhanced sample injection with reverse migrating micelles (FESI-RMM). The sensitivity was improved up to 154-, 263-, and 63-fold, respectively when it was calculated through the peaks height. The optimised methods were validated with spiked mineral water by combining off-line solid-phase extraction (SPE) and the proposed on-line sample stacking strategies. The detection limits (LODs) of NSAIDs in mineral water were at ng/L levels.

Anti-Inflammatory Agents, Non-Steroidal↗

Direct determination of ciprofloxacin by mass spectrometry after a two-step solid-phase extraction using a molecularly imprinted polymer.

A molecularly imprinted polymer (MIP) has been prepared for the first time with ciprofloxacin (CIPRO) as the template molecule, via a noncovalent synthetic procedure. Prior to its use as a sorbent in SPE, the MIP was evaluated chromatographically to confirm that it was indeed molecularly imprinted. The MIP was then used to extract CIPRO selectively from urine samples by means of a two-step SPE procedure in which a commercial Oasis cartridge and a molecularly imprinted SPE cartridge were combined in series. This approach allowed the matrix compounds present in the samples to be removed effectively. The urine extracts obtained after this two-step SPE procedure was applied were relatively clean compared to the original samples, and this made it possible to inject directly the extracts into a mass spectrometer and thus quantify CIPRO in urine samples at low levels and reduce the time of analysis.

Evaluation Study↗

Comparison of mixed-mode anion-exchange performance of N-vinylimidazole-divinylbenzene sorbent.

A newly synthesized copolymer based on N-vinylimidazole-divinylbenzene (NVIm-DVB) was evaluated as a mixed-mode anion-exchange sorbent for SPE, since the NVIm monomer apart from its hydrophilic properties can be protonated at a certain pH, and then performs as an anion-exchanger. To investigate the behavior of the NVIm-based sorbent, the SPE performance was evaluated under reversed-phase (RP), weak anion-exchange, and strong anion-exchange conditions. The results for the NVIm-DVB sorbent were also compared to commercial reference sorbents from each group: Oasis HLB, Oasis WAX, and Oasis MAX, respectively. SPE results from this evaluation showed that NVIm-DVB can be used as an RP material, compared to Oasis HLB. It also has the potential to act as a strong anion-exchange sorbent, compared to Oasis MAX, since under the proper conditions it was able to fraction and quantitatively recover a group of selected solutes.

Journal Article↗

Sample stacking for the analysis of penicillins by microemulsion electrokinetic capillary chromatography.

We present a method for determining eight penicillin antibiotics using microemulsion electrokinetic chromatography (MEEKC). We studied how the composition of the microemulsion affected separation by modifying such parameters as the surfactant or the addition of organic solvents. The best microemulsion system consisted of 0.5% ethyl acetate, 1.2% 1-butanol, 2% Brij 35, 10% 2-butanol and 86.3% 10 mM borate buffer at pH 10. We studied the suitability of this microemulsion composition for analyzing a commercial drug. To improve the sensitivity of the method, we used the stacking technique reversed electrode polarity stacking mode (REPSM), which increased the detection limits by about 40-fold.

Buffers↗

Evaluation of a new hypercrosslinked polymer as a sorbent for solid-phase extraction of polar compounds.

A new hypercrosslinked polymer (HXLGp) with hydrophilic character due to the presence of hydroxyl moieties has been tested as a sorbent for the solid-phase extraction (SPE) of several polar compounds from water samples. This new sorbent enables the on-line extraction of 300 ml of sample with recoveries higher than 80% for polar compounds such as oxamyl, methomyl or desisopropylatrazine (DIA). The HXLGp has also been compared to other commercially available sorbents such as Oasis HLB (hydrophilic macroporous), to hydrophobic hypercrosslinked resins and to a previously synthesized sorbent based on N-vinylimidazole-divinylbenzene. The results are consistently better with the new synthesized sorbent. The method was successfully applied to the on-line SPE-HPLC of tap and river water samples. The validation with river water samples provided good linearity range and detection limits between 0.03 for methomyl and 4-nitrophenol (4NP) to 0.2 microg l(-1) for phenol (Ph).

Chromatography↗

Sample stacking for the analysis of eight penicillin antibiotics by micellar electrokinetic capillary chromatography.

We studied the use of micellar electrokinetic capillary chromatography for separating eight penicillins. The method consists of (i) an electrophoretic separation based on micellar electrokinetic capillary chromatography, which uses sodium dodecyl sulfate (SDS) as surfactant; (ii) a sample stacking technique called reverse electrode polarity stacking mode (REPSM); and (iii) direct UV detection. The background electrolyte that gave complete separation contained 20 mM sodium borate buffer and 60 mM SDS. The sensitivity of the method was improved by an enrichment step that used on-column stacking. The limits of detection were at the microg.L(-1) level for the penicillins and did not detract from the peak resolution.

Anti-Bacterial Agents↗

Separation and on-column preconcentration of some nonsteroidal anti-inflammatory drugs by microemulsion electrokinetic capillary chromatography using high-speed separations.

Various strategies have been investigated for separating a group of nonsteroidal anti-inflammatory drugs (NSAIDs) by microemulsion electrokinetic capillary chromatography (MEEKC) using high-speed separations. The parameters that of affect the separation, such as the nature of the oil droplet and the buffer, and the surfactant concentration have been studied. In addition, several organic solvents were used to decrease the retention of the analytes in the oil droplet phase and to improve the resolution of the NSAIDs. The optimum microemulsion background electrolyte (BGE) solution made of 0.8% w/w ethyl acetate, 6.6% w/w butan-1-ol, 6.0% w/w acetonitrile, 1.0% w/w sodium dodecyl sulfate (SDS), and 85.6% w/w of 10 mM sodium tetraborate at pH 9.2 resolved the drugs within 8 min. The short-end injection procedure is an alternative for reducing the analysis time. When this procedure was used, the microemulsion BGE solution consisted of 0.8% w/w ethyl acetate, 6.6% w/w butan-1-ol, 17.0% w/w methanol, 1.0% w/w SDS, and 74.6% w/w of 10 mM sodium tetraborate, pH 9.2, and the NSAIDs were separated within 3 min. The reversed electrode polarity stacking mode (REPSM) technique was applied to the on-line concentration of the NSAIDs. In this technique, the sample matrix was pumped out of the capillary using a polarity-switching step. When this technique was applied, the sensitivity was enhanced up to 40-fold and the limits of detection (LODs) were in the low microg.L(-1) levels.

2-Propanol↗

Selective enrichment of anti-inflammatory drugs from river water samples by solid-phase extraction with a molecularly imprinted polymer.

A molecularly imprinted polymer (MIP) is synthesised by a noncovalent protocol in which ibuprofen was used as a template molecule. The polymer was evaluated chromatographically and it was seen that the MIP showed cross-reactivity. Subsequently, when this polymer was used as sorbent in SPE it was possible to selectively extract a mixture of nonsteroidal anti-inflammatory drugs from aqueous samples when a cleanup step with dichloromethane was performed. The performance of the MIP was evaluated with river water and water from a wastewater treatment plant, and compared with the performance of a commercial Isolute ENV+ sorbent.

Anti-Inflammatory Agents↗

Occurrence of polybrominated diphenylethers, polychlorinated dibenzo-p-dioxins, dibenzofurans and biphenyls in coastal sediments from Spain.

Fifteen sediment samples were analysed in order to determine their content of polybrominated diphenylethers (PBDEs), polychlorinated dibenzo-p-dioxins (PCDDs), dibenzofurans (PCDFs) and biphenyls (PCBs). Samples were collected from several hot spots on the Spanish coast, such as the harbours of Almeria and Tarragona, and the mouths of the Besos and Llobregat rivers in Barcelona. A generic analytical procedure based on Soxhlet extraction followed by an automated cleanup system and gas chromatography-ion trap-mass spectrometry was employed for determining the toxic congeners of PCDDs and PCDFs, as well as dioxin-like PCBs. As regards PBDE determinations, a rapid method based on the use of selective pressurized liquid extraction followed by gas chromatography-negative ion chemical ionization-mass spectrometry was applied. Total toxicity equivalent (WHO-TEQ) values were calculated using the toxicity equivalent factors proposed by WHO for dioxin-like PCBs, PCDDs and PCDFs. WHO-TEQ values ranged from 0.3 to 75 pg/g dry weight (dw), with PCB contribution on the toxicity of the samples between 1 and 84%. Total PBDE levels ranged from 2.7 to 134 ng/g dw, with BDE-209 contribution on the total PBDE contamination between 50 and 99%.

Benzofurans↗

Occurrence of twenty-six endocrine-disrupting compounds in environmental water samples from Catalonia, Spain.

We monitored 26 compounds known or suspected to be endocrine disruptors in several environmental water samples from a river, the sea, and an irrigation canal. Because of the various chemical properties of the compounds monitored, analyses were carried out by using two different methods. One method is based on solid-phase extraction (SPE) on-line coupled to gas chromatography-mass spectrometry through an on-column interface. Another is based on high-performance liquid chromatography-(electrospray) mass spectrometry working in negative ionization mode and using off-line SPE. The limits of detection for the two methods were at levels of low microg/L. Phthalates and bis-(2-ethylhexyl) adipate were found at levels between 0.05 and 13 microg/L in all of the water samples analyzed. Some pesticides, alkylphenols, and estrogens were determined in a few samples at levels below 0.1 microg/L.

Adipates↗

A new molecularly imprinted polymer for the selective extraction of naproxen from urine samples by solid-phase extraction.

A non-covalent molecularly imprinted polymer (MIP) was synthesised using naproxen (a non-steroidal, anti-inflammatory drug (NSAID)) as a template molecule. The MIP was chromatographically evaluated to confirm the imprinting effect, and was then applied as a selective sorbent in solid-phase extraction (SPE) to selectively extract naproxen. After this study, the MIP was used to extract naproxen from urine samples; it was demonstrated that by applying a selective washing step with acetonitrile (ACN) the compounds in the sample that were structurally related to naproxen could be eliminated.

Anti-Inflammatory Agents, Non-Steroidal↗

Molecularly imprinted solid-phase extraction of naphthalene sulfonates from water.

A new polymeric sorbent synthesised by exploiting molecular imprinting technology has been used to selectively extract naphthalene sulfonates (NSs) directly from aqueous samples. In the non-covalent molecular imprinting approach used to prepare this polymer, 1-naphthalene sulfonic acid (1-NS) and 4-vinylpyridine (4-VP) were used as a template molecule and functional monomer, respectively, and both dissolved in a mixture of methanol/water (4:1) as porogen together with the cross-linker ethylene glycol dimethacrylate. The new non-covalent molecularly imprinted polymer (MIP) prepared in aqueous environment was used as a sorbent in solid-phase extraction (SPE) to selectively extract a group of naphthalene mono- and disulfonates. When one litre of a standard aqueous solution, which contained a mixture of eight NSs, was percolated through the SPE cartridge, all the NSs were retained on the MIP because of the cross-reactivity of the polymer. Recoveries were higher than 80% for all the compounds even after a clean-up step with methanol (MeOH). The MIP was also used to analyse water from the Ebro river.

Naphthalenesulfonates↗

New hydrophilic polymeric resin based on 4-vinylpyridine-divinylbenzene for solid-phase extraction of polar compounds from water.

A 4-vinylpyridine-divinylbenzene (VP-DVB) resin was synthesized to be used for on-line solid-phase extraction process and it was tested for a group of polar compounds. The high specific surface area and the nitrogen content of the VP-DVB sorbent increased the interactions with the polar analytes in the preconcentration process. The sorbent enabled 100 ml of water to be concentrated with recoveries higher than 70% for several polar compounds (including phenol) except for oxamyl (55%) and methomyl (43%). The method was used to analyse water samples by liquid chromatography and UV detection. Linearity was good and detection limits were 0.1-0.2 microg l(-1) for all compounds. Several tap and river water and waste water treatment plant samples were analyzed; phenol and (4-chloro-2-methyl-phenoxy)acetic acid (MCPA) were tentatively determined in some samples.

Polymers↗

Quantification from highly drifted and overlapped chromatographic peaks using second-order calibration methods.

For determining low levels of pesticides and phenolic compounds in river and wastewater samples by high performance liquid chromatography (HPLC), solid phase extraction (SPE) is commonly used before the chromatographic separation. This preconcentration step is not necessarily selective for the analytes of interest and it may retain other compounds of similar characteristics as well. In this case, we present, humic and fulvic acids caused a large baseline drift and overlapped the analytes to be quantified. The inaccurate determinations of the area of the peaks of these analytes made it difficult to quantify them with univariate calibration. Here we compare three second-order calibration algorithms (generalized rank annihilation method (GRAM), parallel factor analysis (PARAFAC) and multivariate curve resolution-alternating least squares (MCR-ALS)) which efficiently solve this problem. These methods use second-order data, i.e., a matrix of responses for each peak, which is easily obtained with a high performance liquid chromatography-diode array detector (HPLC-DAD). With these methods, the area does not need to be directly measured and predictions are more accurate. They also save time and resources because they can quantify analytes even if the peaks are not resolved. GRAM and PARAFAC require trilinear data. Biased and imprecise concentrations (relative standard deviation, %R.S.D. = 34) were obtained without correcting the time-shift. Hence, a time-shift correction algorithm to align the peaks was needed to obtain accurate predictions. MCR-ALS was the most robust to the time-shift. All three algorithms provided similar mean predictions, which were comparable to those obtained when sulfite was added to the samples. However, the predictions for the different replicates were more similar for the second-order algorithms (%R.S.D. = 3) than the ones obtained by univariate calibration after the sulfite addition (%R.S.D. = 13).

Calibration↗

Solid-phase extraction of polar compounds with a hydrophilic copolymeric sorbent.

A new synthesized copolymer based on N-vinylimidazole-divinylbenzene (VIm-DVB) was tested as a sorbent for the solid-phase extraction (SPE) of polar analytes. In the on-line SPE, this synthesized sorbent enabled 100 ml of sample to be preconcentrated with recoveries as high as 80% for oxamyl, phenol (Ph) and derivates, bentazone and (4-chloro-2-methylphenoxy)acetic acid (MCPA). For the off-line SPE, 1000 ml of sample was extracted and recoveries were higher than 92% for all compounds with the exception of oxamyl (83%) and methomyl (78%). The VIm-DVB sorbent gives better recoveries than the previously synthesized 4-vinylpyridine-divinylbenzene (VP-DVB) resin and similar to such highly crosslinked commercial sorbents as LiChrolut EN or Oasis HLB. Real water samples were used to validate the on-line SPE method. Linearity was good and detection limits were between 0.1 and 0.2 microg l(-1).

Imidazoles↗

Application of capillary electrophoresis with different sample stacking strategies for the determination of a group of nonsteroidal anti-inflammatory drugs in the low microg x L(-1) concentration range.

Several on-column sample preconcentration modes--large-volume sample stacking using the EOF pump (LVSEP), LVSEP with anion-selective exhaustive injection (LVSEP-ASEI) and field-amplified sample injection with sample matrix removal using the electroosmotic flow (EOF) pump (FAEP)--were used to analyze some nonsteroidal anti-inflammatory drugs (NSAIDs) by capillary electrophoresis, and then compared. Methanol was the background electrolyte solvent to suppress the EOF. The effect of the type and length of the solvent plug, and the sample injection time were investigated in FAEP to determine the conditions that provided the best response. LVSEP, LVSEP-ASEI, and FAEP improved the sensitivity of the peak area by 100-, 1200-, and 1800-fold, respectively. The methodology developed, in combination with solid-phase extraction (SPE), was applied to the analysis of water samples.

Anti-Inflammatory Agents, Non-Steroidal↗

Determination of some acidic drugs in surface and sewage treatment plant waters by capillary electrophoresis-electrospray ionization-mass spectrometry.

We describe an analytical method involving solid-phase extraction (SPE) and capillary zone electrophoresis-electrospray ionization-mass spectrometry (CZE-ESI-MS) for determining some pharmaceutical compounds - naproxen, clofibric acid and bezafibrate - in real water samples. The electrospray parameters were optimized to maximize sensitivity. When a mixed aqueous-organic solvent and CZE-ESI-MS were used to analyze these drugs in water samples, the capillary was coated with hexadimethrin bromide (HDB) to permanently reverse the EOF. The method was developed from off-line SPE-CZE-MS and was validated with surface water. The detection limits were 100 ng.L(-1) for all analytes. The method was applied to analyze water samples from the influent and effluent of a sewage treatment plant. A liquid-liquid extraction step was required before SPE, and the compounds studied were found, some of them between detection and quantification limits.

Acids↗

Determination of antibiotic compounds in water by solid-phase extraction-high-performance liquid chromatography-(electrospray) mass spectrometry.

We developed a sensitive method based on solid-phase extraction and high-performance liquid chromatography coupled to mass spectrometry using an electrospray interface for the determination of four tetracyclines and two quinolones in water. The method was applied to river, well and sewage-treatment-plant waters. For the solid-phase extraction of 1000 ml river water samples, recoveries were between 88 and 112% and limits of detection were as low as 4 and 6 ng l(-1). Recoveries were higher than 64% for 1000 ml well water samples for the majority of the compounds. For the influent and effluent of the sewage-treatment-plant sample volumes of 100 and 250 ml were extracted, respectively. The method developed allowed ciprofloxacin to be determined in samples from the influent and effluent of the sewage-treatment-plant at 0.58 and 0.60 microg l(-1), respectively.

Anti-Bacterial Agents↗