Search PubMed⌕ Search

Biomedical subjects

Felix Eckstein

Publications and source records attributed to Felix Eckstein.

30 records · Page 2Linked to original sources

Femoro-tibial cartilage metrics from coronal MR image data: Technique, test-retest reproducibility, and findings in osteoarthritis.

MRI-based measures of cartilage morphology are being increasingly used as surrogate markers in osteoarthritis. In contrast to other knee joint surfaces, quantitative analysis of the femoral condyles from sagittal MRI suffers from limited precision. The objective, therefore, was to develop a technique for reproducible assessment of femoral cartilage morphology from coronal image data. Coronal MR images (3D T(1)-w FLASHwe) of the knee were obtained in 16 healthy volunteers and in 7 patients with severe osteoarthritis (OA, prior to knee arthroplasty), with repositioning between repeated scans. After segmentation the cartilage volume, thickness, and joint surface areas were quantified in the tibia and in an anatomically defined region of the femoral condyle. Immediate test-retest interscan precision errors (CV%) for femoral cartilage volume were 3.0% (SD = 26 microl) and 3.2% (29 microl) medially and laterally in volunteers, and 3.0% (34 microl) and 7.0% (37 microl) in OA patients. The estimated loss, from cross sectional data, in the patients in the medial femoral condyle (-61%/-4.4 SD) was higher than that in the medial tibia (-45%/-3.1 SD) and compared favorably with precision errors (ratio > 16:1). The technique proposed overcomes some of the problems associated with sagittal scans and thus shows high promise for reliable assessment of femoro-tibial cartilage loss in OA.

Adult↗

Inhomogeneous cartilage properties enhance superficial interstitial fluid support and frictional properties, but do not provide a homogeneous state of stress.

It has been well established that articular cartilage is compositionally and mechanically inhomogenous through its depth. To what extent this structural inhomogeneity is a prerequisite for appropriate cartilage function and integrity is not well understood. The first hypothesis to be tested in this study was that the depth-dependent inhomogeneity of the cartilage acts to maximize the interstitial fluid load support at the articular surface, to provide efficient frictional and wear properties. The second hypothesis was that the inhomogeneity produces a more homogeneous state of elastic stress in the matrix than would be achieved with uniform properties. We have, for the first time, simultaneously determined depth-dependent tensile and compressive properties of human patellofemoral cartilage from unconfined compression stress relaxation tests. The results show that the tensile modulus increases significantly from 4.1 +/- 1.9 MPa in the deep zone to 8.3 +/- 3.7 MPa at the superficial zone, while the compressive modulus decreases from 0.73 +/- 0.26 MPa to 0.28 +/- 0.16 MPa. The experimental measurements were then implemented with the finite-element method to compute the response of an inhomogeneous and homogeneous cartilage layer to loading. The finite-element models demonstrate that structural inhomogeneity acts to increase the interstitial fluid load support at the articular surface. However, the state of stress, strain, or strain energy density in the solid matrix remained inhomogeneous through the depth of the articular layer, whether or not inhomogeneous material properties were employed. We suggest that increased fluid load support at the articular surface enhances the frictional and wear properties of articular cartilage, but that the tissue is not functionally adapted to produce homogeneous stress, strain, or strain energy density distributions. Interstitial fluid pressurization, but not a homogeneous elastic stress distribution, appears thus to be a prerequisite for the functional and morphological integrity of the cartilage.

Anisotropy↗

Influence of adducting and abducting muscle forces on the subacromial space width.

PURPOSE: Strengthening of the shoulder depressors is an important component in the treatment of impingement syndrome. However, the quantitative effect of various muscle forces on the width of the subacromial space has never been demonstrated in vivo. Therefore, the purpose of this study was to analyze the influence of adducting and abducting muscle forces on the subacromial space width in healthy volunteers in various arm positions. METHODS: The shoulders of 12 healthy volunteers were imaged with an open MR system at 30 degrees, 60 degrees, 90 degrees, 120 degrees, and 150 degrees of arm elevation under both isometric adducting and abducting muscle activity (15 N). After segmentation and three-dimensional reconstruction of anatomically relevant structures, the minimal spatial acromiohumeral and claviculohumeral distances were quantified. RESULTS: Adducting muscle forces led to a significant increase of the acromiohumeral distance in all arm positions (P < 0.01), varying from 32% (30 degrees ) to 138% (90 degrees ) relative to abducting muscle forces. The claviculohumeral distance showed an increase of 9% (30 degrees ) to 24% (90 degrees ), this increase being also statistically significant at all positions (P < 0.05). During elevation of the arm (30-120 degrees ), the absolute subacromial space width was reduced significantly (P = 0.001) by 30% under isometric contraction of the adductors compared with 53% (P = 0.001) under activation of the abductors. CONCLUSION: This in vivo study shows for the first time that adducting muscle forces lead to a significant increase of the subacromial space width compared with abducting muscle activity. In the future, this technique and data can be used to objectively quantify the effect of physical therapy protocols focused on increasing the depressor effect of adducting muscles in the postoperative and conservative treatment of impingement syndrome of the shoulder.

Acromion↗

Can novel clinical densitometric techniques replace or improve DXA in predicting bone strength in osteoporosis at the hip and other skeletal sites?

New peripheral techniques are now available for the diagnosis of osteoporosis, but their value in the clinical management of the disease remains controversial. This study tests the hypothesis that peripheral quantitative computed tomography (pQCT) at the distal radius and/or quantitative ultrasound (QUS) at the calcaneus can serve as replacement or improvement of current methodology (QCT and DXA) for predicting bone strength at the hip and other sites. In 126 human cadavers (age, 80.2 +/- 10.4 years), DXA of the femur, spine, and radius and pQCT of the radius were acquired with intact soft tissues. QCT (spine) and QUS (calcaneus) were performed ex situ in degassed specimens. Femoral failure loads were assessed in side impact and vertical loading. Failure loads of the thoracolumbar spine were determined at three levels in compression and those of the radius by simulating a fall. Site-specific DXA explained approximately 55% of the variability in femoral strength, whereas pQCT and QUS displayed a lower association (15-40%). QUS did not provide additional information on mechanical strength of the femur, spine, or radius. All techniques displayed similar capability in predicting a combined index of failure strength at these three sites, with only QUS exhibiting significantly lower associations than other methods. These experimental results suggest that clinical assessment of femoral fracture risk should preferably rely on femoral DXA, whereas DXA, QCT, and pQCT display similar capability of predicting a combined index of mechanical strength at the hip, spine, and radius.

Absorptiometry, Photon↗

Precision and accuracy of peripheral quantitative computed tomography (pQCT) in the mouse skeleton compared with histology and microcomputed tomography (microCT).

UNLABELLED: pQCT was evaluated for accuracy of phenotypic characterization of mouse bone in vivo. Bones (tibia, femur, spine) of 27 animals were measured ex vivo with pQCT, microCT, and histomorphometry and of 23 mice in vivo (pQCT). pQCT yielded satisfactory in vivo precision and accuracy in skeletal characterization. INTRODUCTION: Important aspects of modern skeletal research depend on the phenotypic characterization of genetically manipulated mice, with some approaches requiring in vivo measurement. Peripheral quantitative computed tomography (pQCT) is applicable in vivo and provides opportunities to determine a large variety of bone parameters. Here we test the ex vivo and in vivo reproducibility of pQCT, and its accuracy in comparison with histomorphometry and microcomputed tomography (microCT). MATERIALS AND METHODS: We examined the tibia, femur, and lumbar spine of 27 mice ex vivo with high-resolution pQCT, using two mouse models (wild-type and ob/ob) with known differences in bone density. Measurements were repeated three times at different days in nine animals. In a second experiment, 23 animals (10 wild-type and 13 bGH transgenic mice) were repeatedly measured in vivo at 12 and 13 weeks of age, respectively. RESULTS: Among metaphyseal sites, the ex vivo precision was highest at the distal femur (RMS CV < 1% for density and < 2% for area). The correlation between density (pQCT) and bone volume fraction (histomorphometry) was r2 = 0.79 (tibia, femur, and spine), and that with microCT was r2 = 0.94 (femur). At the diaphysis, the precision was highest at the femur (< 2% for total and cortical area), and the correlation with microCT was r2 > 0.77. The in vivo precision for bone density (distal femur) was 2.3-5.1%, and that for absolute and relative cortical area (tibia) was 3.1% and 2.2%. CONCLUSIONS: The results show that pQCT can yield satisfactory precision and accuracy in skeletal characterization of mouse bones, if properly applied. The potential advantage of pQCT is that it provides a large set of parameters on bone properties and that it can be used in vivo, extending the available methodological repertoire for genetic studies.

Animals↗

Insulin-like growth factor-binding protein-2 (IGFBP-2) overexpression negatively regulates bone size and mass, but not density, in the absence and presence of growth hormone/IGF-I excess in transgenic mice.

Insulin-like growth factor-binding protein-2 (IGFBP-2) has been suggested to be a negative regulator of bone growth and maintenance. The objective of this study was to characterize the effect of elevated IGFBP-2 on the skeletal phenotype of adult transgenic mice, in the absence and presence of growth hormone (GH) excess. 43 male mice were examined at an age of 4 months (7 IGFBP-2 transgenic mice, 12 GH transgenic mice, 10 mice carrying both transgenes, and 14 controls). The bone mineral content of the total skeleton and of isolated bones was quantified by dual energy X-ray absorptiometry (DXA), after validation versus ash analysis. Cortical and trabecular bone was quantified by peripheral quantitative computed tomography (pQCT), after validation versus microCT. A strong linear relationship was found between DXA and ash weight, and between pQCT and micro CT ( r>0.95). Bone size and bone mineral content were significantly reduced in IGFBP-2 transgenic mice, the magnitude of the effect varying between skeletal sites and between bone compartments. Elevated IGFBP-2 negatively modulated the GH-stimulated increase in bone size and mineral content, and completely blocked GH-effects at cortical sites. Notably, bone density was not decreased in IGFBP-2 transgenic animals compared with controls. In conclusion, IGFBP-2 is identified as a potent negative regulator of normal and GH-stimulated bone growth in vivo. Interestingly, elevated IGFBP-2 levels did not lead to a decrease in bone density, suggesting that IGFBP-2 negatively affects bone size and mineral content, but not bone maintenance in adult mice.

Absorptiometry, Photon↗

Surface size, curvature analysis, and assessment of knee joint incongruity with MRI in vivo.

The purpose of this study was to develop an MR-based technique for quantitative analysis of joint surface size, surface curvature, and joint incongruity and to assess its reproducibility under in vivo imaging conditions. The surface areas were determined after 3D reconstruction of the joint by triangulation and the incongruity by Gaussian curvature analysis. The precision was tested by analyzing four replicated MRI datasets of human knees in 14 individuals. The algorithms were shown to produce accurate data in geometric test objects. The interscan precision was <4% (CV%) for surface area, 2.9-5.7 m(-1) (SD) for the mean principal curvature, and 4.1-7.4 m(-1) for congruence indices. Incongruity was highest in the femoropatellar joint (79.7 m(-1)) and lowest in the medial femorotibial joint (28.6 m(-1)). This technique will permit identification of the specific role of surface size, curvature, and incongruity as potential risk factors for osteoarthritis.

Adult↗

Quantitative cartilage imaging of the human hind foot: precision and inter-subject variability.

Alterations of ankle cartilage are observed in degenerative and inflammatory joint disease, but cartilage cannot be directly visualized by radiography. The purpose of this study was therefore to analyze the feasibility and precision of quantitative cartilage imaging in the human hind foot (talocrural, talotarsal, and intertarsal joints), and to report the inter-subject variability for cartilage volume, thickness and surface areas. The feet of 16 healthy volunteers were imaged using a 3D gradient-echo magnetic resonance imaging sequence with water-excitation. After interpolation to a resolution of 1 x 0.125 x 0.125 mm3 the cartilage plates were segmented, and the cartilage volume, thickness, and surface areas determined. The precision (four repeated measurements) was examined in eight volunteers, the RMS average CV% being 2.1% to 10.9% in single joint surfaces, and < or = 3% for the cumulative values of all joints. The mean cartilage thickness ranged from 0.57+/-0.08 (navicular surface) to 0.89+/-0.19 mm (trochlear surface for tibia). In conclusion this study shows that it is feasible to quantify thin cartilage layers in the hind foot under in vivo imaging conditions, and that the precision errors are substantially smaller than the inter-subject variability in healthy subjects.

Adult↗

Three-dimensional analysis and visualization of regional MR signal intensity distribution of articular cartilage.

The aim of this study was to develop a technique for analyzing and visualizing the regional, three-dimensional signal intensity distribution of articular cartilage in MR images, as a potential surrogate marker of structural or biochemical alterations in early osteoarthritis. Exemplary MR-images of human patellae were acquired at a resolution of 1.5 x 0.31 x 0.31 mm(3), using a gradient-echo sequence with water excitation, and by combining three data sets to secondary images of proton density. After segmentation of the cartilage outlines, these were transferred to the other images. Contiguous slices were automatically divided into sub-regions that extend from the surface to the bone interface (layers) as well as from medial to lateral (sections). The signal intensity was then calculated and projected onto a three-dimensional representation of the articular surface, either by averaging through the depth (sections) or by visualizing the signal intensity at distinct levels in depth (layers). The exemplary data indicate that the reproducibility for regional analyses is in the same range as for the entire patellar cartilage, and that the distribution patterns of proton density delineated with MRI are in agreement with the literature. In conjunction with suitable MR protocols, this post-processing technique has potential to allow for detection and quantification of early degenerative processes in cartilage, before macro-morphological lesions occur.

Adult↗

Bone strength at clinically relevant sites displays substantial heterogeneity and is best predicted from site-specific bone densitometry.

In this study we test the hypotheses that mechanical bone strength in elderly individuals displays substantial heterogeneity among clinically relevant skeletal sites, that ex situ dual-energy X-ray absorptiometry (DXA) provides better estimates of bone strength than in situ DXA, but that a site-specific approach of bone densitometry is nevertheless superior for optimal prediction of bone failure under in situ conditions. DXA measurements were obtained of the lumbar spine, the left femur, the left radius, and the total body in 110 human cadavers (age, 80.6 +/- 10.5 years; 72 female, 38 male), including the skin and soft tissues. The bones were then excised, spinal and femoral DXA being repeated ex situ. Mechanical failure tests were performed on thoracic vertebra 10 and lumbar vertebra 3 (compressive loading of a functional unit), the left and right femur (side impact and vertical loading configuration), and the left and right distal radius (fall configuration, axial compression, and 3-point-bending). The failure loads displayed only very moderate correlation among sites (r = 0.39 to 0.63). Ex situ DXA displayed slightly higher correlations with failure loads compared with those of in situ DXA, but the differences were not significant and relatively small. Under in situ conditions, DXA predicted 50-60% of the variability in bone failure loads at identical (or closely adjacent) sites, but only around 20-35% at distant sites, advocating a site-specific approach of densitometry. These data suggest that mechanical competence in the elderly is governed by strong regional variation, and that its loss in osteoporosis may not represent a strictly systemic process.

Absorptiometry, Photon↗

Radius bone strength in bending, compression, and falling and its correlation with clinical densitometry at multiple sites.

This study comprehensively analyzes the ability of site-specific and nonsite-specific clinical densitometric techniques for predicting mechanical strength of the distal radius in different loading configurations. DXA of the distal forearm, spine, femur, and total body and peripheral quantitative computed tomography (pQCT) measurements of the distal radius (4, 20, and 33%) were obtained in situ (with soft tissues) in 129 cadavers, aged 80.16 +/- 9.8 years. Spinal QCT and calcaneal quantitative ultrasound (QUS) were performed ex situ in degassed specimens. The left radius was tested in three-point bending and axial compression, and the right forearm was tested in a fall configuration, respectively. Correlation coefficients with radius DXA were r = 0.89, 0.84, and 0.70 for failure in three-point bending, axial compression, and the fall simulation, respectively. The correlation with pQCT (r = 0.75 for multiple regression models with the fall) was not significantly higher than for DXA. Nonsite-specific measurements and calcaneal QUS displayed significantly (p < 0.01) lower correlation coefficients, and QUS did only contribute to the prediction of axial failure stress but not of failure load. We conclude that a combination of pQCT parameters involves only marginal improvement in predicting mechanical strength of the distal radius, nonsite-specific measurements are less accurate for this purpose, and QUS adds only little independent information to site-specific bone mass. Therefore, the noninvasive diagnosis of loss of strength at the distal radius should rely on site-specific measurements with DXA or pQCT and may be the earliest chance to detect individuals at risk of osteoporotic fracture.

Absorptiometry, Photon↗

Trabecular bone structure obtained from multislice spiral computed tomography of the calcaneus predicts osteoporotic vertebral deformities.

PURPOSE: To compare multislice computed tomography (MSCT)-derived parameters of the trabecular bone structure of the calcaneus with bone mineral density (BMD) in their ability to differentiate between donors with and without osteoporotic fractures of the spine and to optimize CT scan protocols. METHODS: Forty-two postmortem calcanei (81.2 +/- 10 years) were imaged with a 16-detector row MSCT system using 4 different scan protocols varying spatial resolution (12-24 lp/cm) and radiation dose. Structural parameters of trabecular bone were derived from these images, and BMDs of the calcanei were determined using dual x-ray absorptiometry. Vertebral deformities of the spine were radiographically classified using the Spinal Fracture Index. Diagnostic performance in differentiation between donors with and without vertebral fractures was assessed using receiver operating characteristic (ROC) analysis. RESULTS: There were significant case-control differences for many of the structural parameters measured (P < 0.05). The highest ROC values were found for apparent trabecular thickness using the high-resolution and high-dose protocols. Statistically significant correlations were found between most structure parameters and BMD (up to r = 0.85, P < 0.01). CONCLUSION: Structural parameters of trabecular bone as obtained from high-resolution MSCT images of the calcaneus can be used to differentiate between donors with and without osteoporotic vertebral fractures, using a high-resolution and high-dose CT protocol.

Absorptiometry, Photon↗