Search PubMed⌕ Search

Biomedical subjects

Felix Eckstein

Publications and source records attributed to Felix Eckstein.

At least 19 recordsLinked to original sources

Trabecular bone structure of the calcaneus: comparison of MR imaging at 3.0 and 1.5 T with micro-CT as the standard of reference.

PURPOSE: To investigate in vitro the calcaneal trabecular bone structure in elderly human donors with high spatial resolution magnetic resonance (MR) imaging at 3.0 T and 1.5 T, to quantitatively compare MR measures of bone microarchitecture with those from micro-computed tomography (CT), and to compare the performance of 3.0-T MR imaging with that of 1.5-T MR imaging in differentiating donors with spinal fractures from those without spinal fractures. MATERIALS AND METHODS: The study was performed in line with institutional and legislative requirements; all donors had dedicated their body for educational and research purposes prior to death. Sagittal MR images of 49 human calcaneus cadaveric specimens were obtained (mean age of donors, 79.5 years +/- 11 [standard deviation]; 26 male donors, 23 female donors). After the spatial coregistering of images acquired at 3.0-T and 1.5-T MR imaging, the signal-to-noise-ratios and structural parameters obtained at each magnetic field strength were compared in corresponding sections. Micro-CT was performed on calcaneus cores obtained from corresponding regions in 40 cadaveric specimens. Vertebral deformities of the thoracic and lumbar spine were radiographically classified by using the spinal fracture index. Diagnostic performance of the structural parameters in differentiating donors with vertebral fractures from those without was assessed by using receiver operator characteristic (ROC) analysis, including area under the ROC curve (A(z)). RESULTS: Correlations between structural parameters at 3.0-T MR imaging and those at micro-CT were significantly higher (P < .05) than correlations between structural parameters at 1.5-T MR imaging and those at micro-CT (trabecular thickness, r = 0.76 at 3.0 T vs r = 0.57 at 1.5 T). Trabecular dimensions were amplified at 3.0 T because of increasing susceptibility artifacts. Also, higher ROC values were found for structural parameters at 3.0 T than at 1.5 T, but differences were not significant (trabecular thickness, A(z) = 0.75 at 3.0 T vs A(z) = 0.66 at 1.5 T, P > .05). CONCLUSION: MR imaging at 3.0 T provided a better measure of the trabecular bone structure than did MR imaging at 1.5 T. There was a trend for better differentiation of donors with from those without osteoporotic vertebral fractures at 3.0 T than at 1.5 T.

Aged↗

Quantitative MRI of cartilage and bone: degenerative changes in osteoarthritis.

Magnetic resonance imaging (MRI) and quantitative image analysis technology has recently started to generate a great wealth of quantitative information on articular cartilage and bone physiology, pathophysiology and degenerative changes in osteoarthritis. This paper reviews semiquantitative scoring of changes of articular tissues (e.g. WORMS = whole-organ MRI scoring or KOSS = knee osteoarthritis scoring system), quantification of cartilage morphology (e.g. volume and thickness), quantitative measurements of cartilage composition (e.g. T2, T1rho, T1Gd = dGEMRIC index) and quantitative measurement of bone structure (e.g. app. BV/TV, app. TbTh, app. Tb.N, app. Tb.Sp) in osteoarthritis. For each of these fields we describe the hardware and MRI sequences available, the image analysis systems and techniques used to derive semiquantitative and quantitative parameters, the technical accuracy and precision of the measurements reported to date and current results from cross-sectional and longitudinal studies in osteoarthritis. Moreover, the paper summarizes studies that have compared MRI-based measurements with radiography and discusses future perspectives of quantitative MRI in osteoarthritis. In summary, the above methodologies show great promise for elucidating the pathophysiology of various tissues and identifying risk factors of osteoarthritis, for developing structure modifying drugs (DMOADs) and for combating osteoarthritis with new and better therapy.

Animals↗

Association of geometric factors and failure load level with the distribution of cervical vs. trochanteric hip fractures.

UNLABELLED: We experimentally studied the distribution of hip fracture types at different structural mechanical strength. Femoral neck fractures were dominant at the lowest structural strength levels, whereas trochanteric fractures were more common at high failure loads. The best predictor of fracture type across all failure loads and in both sexes was the neck-shaft angle. INTRODUCTION: Bone geometry has been shown to be a potential risk factor for osteoporotic fractures. Risk factors have been shown to differ between cervical and trochanteric hip fractures. However, the determinants of cervical and trochanteric fractures at different levels of structural mechanical strength are currently unknown. In addition, it is not known if the distribution of fracture types differs between sexes. The aim of this experimental study on excised femora was to investigate whether there exist differences in the distribution of cervical and trochanteric fractures between different structural mechanical strength levels and different sexes and to identify the geometric determinants that predict a fracture type. MATERIALS AND METHODS: The sample was comprised of 140 cadavers (77 females: mean age, 81.7 years; 63 males: mean age, 79.1 years) from whom the left femora were excised for analysis. The bones were radiographed, and geometrical parameters were determined from the digitized X-rays. The femora were mechanically tested in a side impact configuration, simulating a sideways fall. After the mechanical test, the fracture patterns were classified into cervical and trochanteric. RESULTS: The overall proportion of cervical fractures was higher in females (74%) than in males (49%) (p = 0.002). The fracture type distribution differed significantly across load quartiles in females (p = 0.025), but not in males (p = 0.205). At the lowest load quartiles, 94.7% of fractures in female and 62.5% in males were femoral neck fractures. At the highest quartiles, in contrast, only 52.6% of fractures in females and 33.3% in males were cervical fractures. Among geometric variables, the neck-shaft angle was the best predictor of fracture type, with higher values in subjects with cervical fractures. This finding was made in females (p < 0.001) and males (p = 0.02) and was consistent across all failure load quartiles. CONCLUSIONS: Femoral neck fractures predominate at the lowest structural mechanical strength levels, whereas trochanteric fractures are more common at high failure loads. Females are more susceptible to femoral neck fractures than males. The best predictor of fracture type across all structural strength levels and both sexes was the neck-shaft angle.

Aged↗

Non-invasive axial loading of mouse tibiae increases cortical bone formation and modifies trabecular organization: a new model to study cortical and cancellous compartments in a single loaded element.

Systematic study of bones' responses to loading requires simple non-invasive models in appropriate experimental animals where the applied load is controllable and the changes in bone quantifiable. Herein, we validate a model for applying axial loads, non-invasively to murine tibiae. This allows the effects of mechanical loading in both cancellous and cortical bone to be determined within a single bone in which genetic, neuronal and functional influences can also be readily manipulated. Using female C57Bl/J6 mice, peak strains at the tibial mid-shaft were measured during walking (<300 micro epsilon tension) and jumping (<600 micro epsilon compression) with single longitudinally oriented strain gauges attached to the bone's lateral and medial surfaces. Identically positioned gauges were also used to determine, for calibration, the strains engendered by external applied compressive tibial loading between the flexed knee and ankle ex vivo. Applied loads between 5 and 13 N produced strains of 1150-2000 micro epsilon on the lateral surface, and in vivo repetitions of these loads on alternate days for 2 weeks produced significant load magnitude-related increases in cortical bone formation that were similar in mice at 8, 12 and 20 weeks of age. Micro-CT scans showed that loading significantly increases trabecular bone volume in 8 week old mice, but modifies trabecular organization with decreases in trabecular bone volume in 12 and 20 week old mice. This model for loading the tibia has several advantages over other approaches, including scope to study the effects of loading in cancellous as well as cortical bone, against a background of either disuse or of treatment with osteotropic agents within a single bone in normal, mutant and transgenic mice.

Adaptation, Physiological↗

Accuracy and precision of quantitative assessment of cartilage morphology by magnetic resonance imaging at 3.0T.

OBJECTIVE: Quantitative magnetic resonance imaging (MRI) of articular cartilage represents a powerful tool in osteoarthritis (OA) research, but has so far been confined to a field strength of 1.5T. The aim of this study was to evaluate the precision of quantitative MRI assessments of human cartilage morphology at 3.0T and to correlate the measurements at 3.0T with validated measurements at 1.5T. METHODS: MR images of the knee of 15 participants with OA and 15 healthy control subjects were acquired using Siemens 1.5T and 3.0T scanners. Double oblique coronal scans were obtained at 1.5T with a 1.5-mm partition thickness, at 3.0T with a 1.5-mm partition thickness, and at 3.0T with a 1.0-mm partition thickness. Cartilage volume, thickness, and surface area of the femorotibial cartilage plates were quantified using proprietary software. RESULTS: For 1.5-mm partition thickness at 1.5T, the precision error was 3.0% and 2.6% for cartilage volume and cartilage thickness, respectively. The error was smaller for a 1.5-mm partition thickness at 3.0T (2.6% and 2.5%) and still smaller for a 1.0-mm partition thickness at 3.0T (2.1% and 2.0%). Correlation coefficients between values obtained at 3.0T and 1.5T were high (r > or = 0.96), with no significant deviation between the two field strengths. CONCLUSION: Quantitative MRI measurement of cartilage morphology at 3.0T (partition thickness 1 mm) was found to be accurate and tended to be more reproducible than at 1.5T (partition thickness 1.5 mm). Imaging at 3.0T may therefore provide superior ability to detect changes in cartilage status over time and to determine responses to treatment with structure-modifying drugs.

Aged↗

Improved performance of hip DXA using a novel region of interest in the upper part of the femoral neck: in vitro study using bone strength as a standard of reference.

We tested the hypothesis that bone mineral density (BMD) and bone mineral content (BMC) in proximal human femur specimens in the upper neck region of interest (ROI) and femoral neck axis length (FNAL) provide a significantly better prediction of femoral bone strength than standard ROIs in vitro. BMD and BMC were measured in 110 proximal femur specimens using a standard dual-energy X-ray absorptiometry (DXA) scanner. The analysis included a new ROI in the upper neck as well as the standard ROIs. FNAL was obtained from the scan images. The specimens' failure-load was measured in a mechanical loading device, simulating a fall on the greater trochanter. For the standard ROIs, correlations between failure-load and BMD ranged from R2 = 0.64 (shaft ROI) to R2 = 0.70, p < 0.001 (femoral neck). Prediction of strength by BMD did not significantly differ from those of BMC (R2 ranging from 0.65 to 0.75, p < 0.001). In the upper neck ROI, for both BMD and BMC correlations with failure-load were higher (R2 = 0.76 and 0.81, respectively; p < 0.001). A lower, yet still significant, correlation was found between FNAL and bone strength (R2 = 0.23, p < 0.001). Normalization of failure-load with respect to FNAL did not significantly increase the correlations with densitometric measures. This study provides in vitro evidence indicating that among the ROIs of the proximal femur the newly defined upper neck ROI provides the best prediction of bone strength. Only a weak association was observed between failure load and FNAL.

Absorptiometry, Photon↗

Longitudinal in vivo effects of growth hormone overexpression on bone in transgenic mice.

UNLABELLED: In this study we examined the effect of systemic overexpression of GH on bone in transgenic mice longitudinally in vivo over a period of 9 months. We observed substantially increased BMC in GH transgenic mice and a significant reduction in serum osteocalcin. GH effects on bone were strongly dependent on gender and developmental stage. INTRODUCTION: State-of-the-art bone marker and microimaging technology was applied in this longitudinal study to examine bone metabolism, BMC, bone density, and cortical bone structure over the life span of growth hormone (GH) transgenic (tg) mice. MATERIALS AND METHODS: Thirty-eight mice from four genetic groups (male, female, tg, and controls) were examined with DXA, and their femur and tibia were examined with peripheral QCT (pQCT). Osteocalcin (formation) and collagen cross-links (resorption) from serum and urine were also measured at postnatal weeks 3, 6, 9, 12, 18, 26, and 38. RESULTS: GH tg mice displayed a significant increase in body weight (up to 50%) and BMC (up to 90%), but serum osteocalcin was significantly reduced compared with controls. GH tg females (but not males) displayed increased trabecular density over controls up to week 12. In contrast, male (but not female) GH tg mice displayed a higher cortical cross-sectional area than controls. Cortical density was significantly lower in both male and female GH tg mice compared with control mice. CONCLUSIONS: The increase in BMC in GH tg mice is associated with reduced serum osteocalcin levels, indicating that bone turnover may be lower than in the control mice. On a structural level, bone responds to GH excess in a gender-specific manner, with alterations varying substantially between different developmental stages.

Amino Acids↗

Quantitative assessment of cartilage status in osteoarthritis by quantitative magnetic resonance imaging: technical validation for use in analysis of cartilage volume and further morphologic parameters.

OBJECTIVE: Quantitative diagnostic tools for osteoarthritis (OA) are important for evaluating the treatment response to structure-modifying drugs. This study was undertaken to test the technical validity (accuracy) of quantitative magnetic resonance imaging (qMRI) for reliable determination of the total bone interface area, percentage of cartilaginous (denuded) joint surface area, and cartilage thickness in OA. METHODS: High-resolution MRIs of femorotibial and patellar cartilage were acquired in 21 patients prior to total knee arthroplasty, using a T1-weighted gradient-echo sequence with water excitation. After segmentation of original bone interface areas (before disease onset) and the actual cartilage layer, the percentages of cartilaginous joint surface area, cartilage thickness, and cartilage volume were determined using proprietary software. During surgery, the patella and the medial and lateral tibia were resected. Results obtained with qMRI were compared with those obtained by direct image analysis of surface area, cartilage thickness, and cartilage volume of the surgically removed tissue. RESULTS: Pairwise differences between results obtained with qMRI and morphologic analysis were +/-4.6% for percentage of cartilaginous surface area, +/-8.9% for cartilage thickness, and +/-9.1% for cartilage volume. Correlation coefficients ranged from 0.92 (thickness) to 0.98 (volume). CONCLUSION: Quantitative MRI permits technically accurate and differential assessment of increases in eroded joint surface area and reductions in cartilage thickness in OA. The surrogate validity of these parameters requires testing in longitudinal studies. These parameters may be advantageous over determination of cartilage volume alone when diagnosing OA, exploring its progression, or testing responsiveness to new therapies.

Aged↗

Determinants and heterogeneity of mechanical competence throughout the thoracolumbar spine of elderly women and men.

Vertebral fractures represent the hallmark of osteoporosis. Here, we test the hypotheses that (sub)cortical bone strength and density predict failure better than trabecular core strength and density, and that elderly women display lower failure stress of thoracic vertebrae than men. We examined the vertebral bodies T3 to L5 in 39 spines from elderly donors (23 women; 16 men; age 79 +/- 11 years). Peripheral quantitative computed tomography was used to measure total, trabecular, and (sub)cortical bone density. Mechanical tests were performed in functional spinal units, planoparallel sections of vertebrae, trabecular cores, and (sub)cortical ring specimens. The failure stress decreased with descending vertebral level. Failure stress was highest for the (sub)cortical rings and planoparallel sections and lowest for the trabecular core. The failure stress did not differ significantly between men and women. Mechanical strength of the functional unit was more strongly correlated with the strength of the (sub)cortical ring (r = 0.78) than with that of the trabecular core (r = 0.62). However, total density was more highly correlated with mechanical strength of the same and remote vertebrae (r = 0.63) than trabecular (r = 0.50) or (sub)cortical density (r = 0.36), respectively. The results show that vertebral strength is similar in elderly women and men. Strength of (sub)cortical bone provides significantly better prediction of strength of functional spinal units than that of the trabecular core. However, total density predicts functional segment failure stress with higher accuracy than (sub)cortical or trabecular density and is thus recommended for predicting fracture strength clinically.

Aged↗

Strength prediction of the distal radius by bone densitometry--evaluation using biomechanical tests.

Osteoporotic fractures represent an important medical problem as they are often early predictors of future fractures at other skeletal sites. The distal radius is one such fracture site. To determine the individual's risk of fracture, different measurement techniques have been developed. These methods differ in physical background, measurement site, output parameters, and cost. If correctly applied, biomechanical testing can be an efficient tool for the preclinical evaluation of these techniques. With biomechanical testing it is possible to determine the structural strength of bone which can then be correlated with various densitometric parameters. Here we will review experimental work performed in this context. Biomechanical testing conditions vary considerably from study to study with 3-point bending (shaft), axial compression (metaphysis), and fall simulations being some of the techniques used. Experimental evidence suggests that site-specific osteodensitometric measurements can predict the mechanical strength of the distal radius with moderate to high accuracy, but that measurements at remote sites display considerably lower predictive value. Geometry-based parameters of cortical bone are also good predictors, but have not been shown to offer significant advantage over measurement of bone mass. Some (but not all) studies have found that quantitative ultrasound and microstructural parameters contribute significant additional information to bone mass measurement. The most accurate prediction of distal radius fractures, however, appears to be (patient-specific) microstructural finite element modeling.

Animals↗

Measuring cartilage morphology with quantitative magnetic resonance imaging.

Magnetic resonance imaging (MRI) is a three-dimensional imaging technique with unparalleled ability to delineate articular cartilage morphology in health and disease. In this article we will review work on the assessment of cartilage morphology with quantitative magnetic resonance imaging and its relevance to the study of cartilage anatomy, physiology, deformation, disease status, disease progression, and response to treatment. The review outlines available pulse sequences and techniques for segmentation and morphological analysis of cartilage morphology. It addresses the accuracy (validity) and precision (reproducibility) of these techniques and summarizes studies on cartilage deformation in intact joints. This article will also review work on determinants and functional adaptation of cartilage morphology and describe changes seen in osteoarthritis. We conclude that fat-suppressed or water excitation gradient-echo magnetic resonance sequences and state-of-the-art digital image analysis techniques display high accuracy and adequate precision for quantitative assessment of cartilage morphology. This renders these techniques powerful and promising tools for cartilage and osteoarthritis research.

Cartilage, Articular↗

Toward imaging biomarkers for osteoarthritis.

Many new therapeutic strategies have been and are being developed to correct, prevent, or slow the progression of osteoarthritis. Our ability to evaluate the efficacy of these techniques, or to determine the situations for which they might provide the most benefit, critically depends on diagnostic measures that can serve as proxies for the present or predicted state of the cartilage. Many of the magnetic resonance imaging techniques that have been emerging over the past decades appear promising in that they have shown technical validity in measuring the morphologic and molecular state of cartilage. With continued development and added insight from pilot clinical studies, these or related methods may soon be in customary use. These techniques are part of a paradigm shift where therapeutic strategies are developed hand-in-hand with diagnostic approaches-a shift that offers the promise of speeding development of effective therapies, and focusing their use in areas where they can be most successful.

Biomarkers↗

Trabecular bone structure of the distal radius, the calcaneus, and the spine: which site predicts fracture status of the spine best?

RATIONALE AND OBJECTIVES: To compare trabecular bone structure measures obtained in magnetic resonance images of the distal radius and the calcaneus as well as computed tomographic images of the spine versus bone mineral density (BMD) of the spine and the calcaneus in the prediction of osteoporotic spine fracture status. MATERIAL AND METHODS: High-resolution magnetic resonance images of the calcaneus and the distal radius and thin-section computed tomographic images of thoracic and lumbar vertebrae were obtained from 74 cadavers. Structure analysis was performed using parameters analogous to standard histomorphometry. BMD of the spine was determined by using quantitative computed tomography and of the calcaneus by using dual x-ray absorptiometry. Spine radiographs of these cadavers were assessed concerning vertebral deformities. RESULTS: The diagnostic performance in differentiating fracture and nonfracture subjects was highest for structure parameters in the spine and slightly lower for these parameters in the distal radius and for BMD of the spine. CONCLUSION: In this study structure parameters in the spine were best suited to predict the osteoporotic fracture status of the spine.

Absorptiometry, Photon↗

Noninvasive study of human cartilage structure by MRI.

Magnetic resonance (MR) imaging is a 3D imaging technique that has recently begun to permit direct delineation of cartilage structure. This chapter summarizes current methodology for the morphological (e.g., volume, thickness) and compositional imaging of cartilage using quantitative MR as well as for semiquantitative scoring of cartilage disease. The chapter explains the relevance of MR in identifying disease status, in monitoring disease progression, and in identifying risk factors of osteoarthritis, as well as in evaluating treatment response to so-called structure-modifying osteoarthritis drugs. The practical methodological procedures presented involve the description of how to acquire MR images for structural analysis and the semiquantitative scoring of articular cartilage. We also present a description of image-analysis techniques for cartilage segmentation and characterization of cartilage structure (quantitative outcome parameters, such as volume and thickness) and guidelines for how to test the validity (accuracy), precision (reproducibility), and sensitivity to change of such methodologies inosteoarthritis.

Antirheumatic Agents↗

Multislice computed tomography of the distal radius metaphysis: relationship of cortical bone structure with gender, age, osteoporotic status, and mechanical competence.

We explore the relationship of region-specific densitometric and geometry-based (cortical) parameters at the distal radial metaphysis with gender, age, and osteoporotic status, using multislice computed tomography (CT). We specifically test the hypothesis that these parameters can improve the prediction of mechanical strength of the distal radius vs bone mass (bone mineral content [BMC]). The BMC was determined in 56 forearm specimens with peripheral dual-energy X-ray absorptiometry (DXA). Trabecular and cortical density and geometric properties of the metaphyseal cortex were determined using multislice CT and proprietary image analysis software. Specimens were tested to failure in a fall simulation, maintaining the integrity of the elbow joint and hand. Women displayed significantly lower failure strength (-34%), BMC (-35%), trabecular density (-26%), and cortical area (-12%) than men. The reduction of trabecular density with age and osteoporotic status was stronger than that of cortical density or thickness. DXA explained approx 50% (r2) of the variability in bone failure loads. This proportion was slightly increased (55%) when adding geometry-based parameters. The study suggests that high-resolution tomographic measurements with current clinical imaging methodology can marginally improve the prediction of mechanical failure strength. Further efforts are required to improve spatial resolution for determining metaphyseal cortical properties clinically.

Aged↗

Reproducibility and side differences of mechanical tests for determining the structural strength of the proximal femur.

UNLABELLED: In this experimental study, we evaluated the reproducibility error of mechanical strength tests of the proximal femur when simulating a fall on the trochanter. Based on side differences in femoral failure loads in 55 pairs of femora, we estimated the upper limit of the precision error to be 15% for the side impact test, whereas the intersubject variability was >40%. INTRODUCTION: Mechanical tests are commonly used as the gold standard for determining one of the main functions of bones, that is, to provide mechanical strength. However, it is unknown what magnitude of error is associated with these tests. Here we investigate the precision error and side difference of a side impact test of the proximal femur. MATERIALS AND METHODS: BMC was measured using DXA in 54 pairs of femora from donors 79.0 +/- 10.6 years of age. Bones were tested to failure, simulating a fall on the greater trochanter. RESULTS: Failure loads were 3951 +/- 1659N (CV% = 42%) on the right and 3900 +/- 1652N (CV% = 42%) on the left (no significant side difference). The average random difference of femoral BMC was 7 +/- 7% and that of femoral failure loads was 17 +/- 12%. The correlation between BMC and failure load was 79% (r2), but the association between side differences in failure load with those in BMC was only 4%. When confining the analysis to pairs with less than 5% differences in BMC (n = 31), side differences in failure loads were 15 +/- 13%. When correcting failure loads for side differences of BMC, the difference was 16 +/- 15% CONCLUSIONS: These results suggest that the upper limit of the precision error for femoral strength tests is approximately 15% in a side impact configuration. Given the large intersubject variability of failure loads, this test provides an efficient tool for determining the structural strength of the proximal femur in a fall.

Biomechanical Phenomena↗

Correlation of knee-joint cartilage morphology with muscle cross-sectional areas vs. anthropometric variables.

We tested the hypothesis that muscle cross-sectional areas (MCSAs) are more highly (and independently) correlated with cartilage morphology than are body height and weight, and that the physiological reduction of cartilage thickness with aging is associated with a proportional, age-dependent decrease in MCSAs. In 59 asymptomatic individuals (23-75 years old), morphological parameters of the knee cartilages (volume, thickness, and bone-cartilage interface area), and MCSAs were determined from magnetic resonance imaging (MRI) data. Multiple regression models were used to calculate which proportion of the variability of the normal cartilage morphology can be predicted based on independent variables. MCSAs and body height and weight showed correlation coefficients of +0.66, +0.60, and +0.25, respectively, with knee-joint cartilage volume. The correlation coefficients with cartilage thickness were +0.44, +0.35, and +0.24, respectively. Age accounted for a significant (P<0.01) reduction in cartilage thickness, but there was no proportional change of MCSAs. Approximately 76% of the variability of the knee cartilage volume could be predicted from independent variables in a multiple regression model with MCSAs contributing significant, independent information. In conclusion, we find that MCSAs are more highly correlated with cartilage morphology than are body height and weight. The significant decrease in cartilage volume and thickness with age is not associated with a proportional decrease in MCSAs.

Adult↗