Search PubMed⌕ Search

Biomedical subjects

F R Tay

Publications and source records attributed to F R Tay.

At least 37 records · Page 2Linked to original sources

Effect of resin hydrophilicity and water storage on resin strength.

This study evaluated the change in the ultimate tensile strength (UTS) of five polymerised resin blends of increasing hydrophilicity, after ageing in distilled water or silicon oil. Resin blocks were prepared from each resin blend by dispensing the uncured resin into a flexible, embedding mould, containing multiple cavities. The resins were polymerised in the moulds under nitrogen at 551.6 kPa and light-activated at 125 degrees C for 10 min. After dry ageing for 24 h at 37 degrees C, the middle third of each resin specimen was trimmed into an 'I' shape. Fifteen control specimens were randomly selected from each resin blend for baseline UTS evaluation. The UTS of the experimental specimens were determined after 1, 3, 6 and 12 months of ageing in water or oil. The UTS of each group of resins at different storage periods in water or oil were analysed using the Friedman multiple ANOVA on ranks and Dunn's multiple comparison tests at 95% confidence level. Significant reduction (p < 0.01) in UTS was observed in Groups II-V resins after 12-month storage in water, while the most hydrophobic Group I resin showed no significant change (p > 0.05) in the same period. The percentage reduction in UTS increased with the hydrophilicity of the resin blends. Long-term water storage of hydrophilic resin blends such as those employed in dentine adhesives, resulted in a marked reduction in their mechanical strength that may compromise the durability of resin-dentine bonds.

Absorption↗

Adhesive permeability affects coupling of resin cements that utilise self-etching primers to dentine.

OBJECTIVES: To examine the effects of an experimental bonding technique that reduces the permeability of the adhesive layer on the coupling of resin cements to dentine. METHODS: Extracted human third molars had their mid to deep dentin surface exposed flat by transversally sectioning the crowns. Resin composite overlays were constructed and cemented to the surfaces using either Panavia F (Kuraray) or Bistite II DC (Tokuyama) resin cements mediated by their respective one-step or two-step self-etch adhesives. Experimental groups were prepared in the same way, except that the additional layer of a low-viscosity bonding resin (LVBR, Scotchbond Multi-Purpose Plus, 3M ESPE) was placed on the bonded dentine surface before luting the overlays with the respective resin cements. The bonded assemblies were stored for 24 h in water at 37 degrees C and subsequently prepared for microtensile bond strength testing. Beams of approximately 0.8 mm(2) were tested in tension at 0.5 mm/min in a universal tester. Fractured surfaces were examined under scanning electron microscopy (SEM). Additional specimens were prepared and examined with TEM using a silver nitrate-staining technique. RESULTS: Two-way ANOVA showed significant interactions between materials and bonding protocols (p<0.05). When bonded according to manufacturer's directions, Panavia F produced bond strengths that were significantly lower than Bistite II DC (p<0.05). The placement of an additional layer of a LVBR improved significantly the bond strengths of Panavia F (p<0.05), but not of Bistite II DC (p>0.05). SEM observation of the fractured surfaces in Panavia F showed rosette-like features that were exclusive for specimens bonded according to manufacturer's directions. Such features corresponded well with the ultrastructure of the interfaces that showed more nanoleakage associated with the more permeable adhesive interface. The application of the additional layer of the LVBR reduced the amount of silver impregnation for both adhesives suggesting that reduced permeability of the adhesives resulted in improved coupling of the resin cements to dentin. CONCLUSIONS: Placement of an intermediate layer of a LVBR between the bonded dentine surface and the resin cements resulted in improved coupling of Panavia F to dentine.

Acid Etching, Dental↗

Interaction of resin-modified glass-ionomer cements with moist dentine.

OBJECTIVES: The objective of this study was to report on a novel phenomenon that occurs when resin-modified glass-ionomer cements (RMGICs) are bonded to moist human dentine. METHODS: Dentine surfaces from extracted third molars were abraded with 180-grit SiC paper. Ten teeth were prepared for each of the two RMGICs tested (Fuji II LC, GC Corp. and Photac-Fil Quick, 3M ESPE). RMGIC buildups were made according to the manufacturers' instructions. After storage at 37 degrees C, 100% humidity for 24 h, the bonded specimens were cut occlusogingivally into 0.9 x 0.9 mm beams. Dentine surfaces bonded with the two RMGICs were examined along the fractured RMGIC/dentine interfaces. Additional beams fractured within the RMGICS and at 3 mm away from the interfaces were used as controls. The fractured beams were examined using scanning electron microscopy (SEM), field emission-environmental SEM (FE-ESEM) and transmission electron microscopy (TEM). RESULTS: SEM and FE-ESEM revealed numerous solid spherical bodies along the RMGIC/dentine interfaces. By contrast, no spherical bodies could be identified within the RMGIC fractured 3 mm distant from the bonded interface. TEM and energy dispersive X-ray analyses performed on carbon-coated ultrathin sections showed that these solid spherical bodies consisted of a thin aluminum and silicon-rich periphery and an amorphous hydrocarbon core within the air voids of the original resin matrix. CONCLUSION: The spherical bodies probably represent a continuation of GI reaction and poly(HEMA) hydrogel formation that results from water diffusion from the underlying moist dentine. Their existence provides evidence for the permeation of water through RMGIC/dentine interfaces.

Aluminum↗

Single-bottle adhesives behave as permeable membranes after polymerization. I. In vivo evidence.

OBJECTIVES: This study tested the hypothesis that single-bottle total-etch adhesives are effective in reducing dentine permeability under in vivo conditions. METHODS: Crown preparations on vital human teeth were performed under local analgesia as part of the treatment plan for prosthetic rehabilitation. Four single-bottle adhesives (Single Bond, 3M ESPE; Excite DSC, Ivoclar Vivadent; Prime and Bond NT Dual-Cure, Dentsply DeTrey and One-Step, Bisco Inc.) were applied to the cut dentine after acid-etching. Polyvinyl siloxane impressions were taken, using an ultra-low viscosity impression material, of the smear layer-covered dentine before applying the adhesives to deep vital dentine, and after adhesive placement. Additional impressions were taken of the adhesive-sealed dentine following the removal of the provisional prostheses after a 7-10 day period. Epoxy resin replicas of the crown preparations were examined with scanning electron microscopy to evaluate the extent of dentinal fluid transudation during pre-bonded, immediately bonded and post-bonded periods. RESULTS: Dentinal fluid transudation from localised areas that were close to the dental pulp was universally observed from all epoxy resin replicas, irrespective of the adhesive employed. The transudation of dentinal fluid from the control smear layer-covered dentine of each crown preparation was comparatively mild when compared to the extent that was observed after total-etching and application of the single-bottle adhesive. Dentinal fluid droplets were specifically located over the surface of the adhesive layer. Continuous transudation of dentinal fluid occurred even after the removal of the provisional prostheses, and was considerably more profuse in subjects who opted for the fitting of the permanent prostheses without the use of a local anaesthetic solution. CONCLUSION: Single-bottle adhesives, because of their lack of a comparatively more hydrophobic bonding resin layer, behave as permeable membranes after polymerisation. They permit the continuous transudation of dentinal fluid and do not provide a hermetic seal in vital deep dentine. Although the relatively slow rate of diffusion of dentinal fluid is unlikely to result in post-operative cold sensitivity, it may interfere with the optimal polymerisation of dual-cured or auto-cured composites or resin cements in both direct and indirect restorations.

Adhesives↗

Collagen degradation by host-derived enzymes during aging.

Incompletely infiltrated collagen fibrils in acid-etched dentin are susceptible to degradation. We hypothesize that degradation can occur in the absence of bacteria. Partially demineralized collagen matrices (DCMs) prepared from human dentin were stored in artificial saliva. Control specimens were stored in artificial saliva containing proteolytic enzyme inhibitors, or pure mineral oil. We retrieved them at 24 hrs, 90 and 250 days to examine the extent of degradation of DCM. In the 24-hour experimental and 90- and 250-day control specimens, we observed 5- to 6-microm-thick layers of DCM containing banded collagen fibrils. DCMs were almost completely destroyed in the 250-day experimental specimens, but not when incubated with enzyme inhibitors or mineral oil. Functional enzyme analysis of dentin powder revealed low levels of collagenolytic activity that was inhibited by protease inhibitors or 0.2% chlorhexidine. We hypothesize that collagen degradation occurred over time, via host-derived matrix metalloproteinases that are released slowly over time.

Acid Etching, Dental↗

Interaction of glass-ionomer cements with moist dentin.

Glass-ionomer cements (GICs) are regarded as aqueous gels made up of polyalkenoic acid salts containing ion-leachable glass fillers. The consequence of water permeation across the GIC-dentin interface is unknown. This study used SEM, field-emission/environmental SEM (FE-ESEM), and TEM to examine the ultrastructure of GIC-bonded moist dentin. Dentin surfaces bonded with 6 auto-cured GICs were examined along the fractured GIC-dentin interfaces. Additional specimens fractured 3 mm away from the interfaces were used as controls. SEM revealed spherical bodies along GIC-dentin interfaces that resembled hollow eggshells. FE-SEM depicted similar bodies with additional solid cores. Energy-dispersive x-ray analysis and TEM showed that the spherical bodies consisted of a silicon-rich GIC phase that was absent from the air-voids in the controls. The GIC inclusions near dentin surfaces result from a continuation of the GI reaction, within air-voids of the original polyalkenoate matrix, that occurred upon water diffusion from moist dentin.

Adhesiveness↗

Osmotic blistering in enamel bonded with one-step self-etch adhesives.

One-step self-etch adhesives behave as permeable membranes after polymerization, permitting water to move through the cured adhesives. We hypothesize that osmotic blistering occurs in bonded enamel when these adhesives are used without composite coupling. Tooth surfaces from extracted human premolars were bonded with 5 one-step self-etch adhesives. They were immersed in distilled water or 4.8 M CaCl(2), and examined by stereomicroscopy, field-emission/environmental SEM, and TEM. Water blisters were observed in bonded enamel but not in bonded dentin when specimens were immersed in water. They collapsed when water was subsequently replaced with CaCl(2). Blisters were absent from enamel in specimens that were immersed in CaCl(2) only. Water trees were identified from adhesive-enamel interfaces. Osmotic blistering in enamel is probably caused by the low water permeability of enamel. This creates an osmotic gradient between the bonded enamel and the external environment, causing water sorption into the interface.

Acid Etching, Dental↗

Collagen degradation in endodontically treated teeth after clinical function.

Endodontically treated teeth restored with posts are susceptible to coronal leakage after long-term function. We hypothesize that demineralized collagen matrices (DCMs) created in dentin by acidic zinc phosphate cement within the dowel spaces degrade with time. Forty-two post-restored teeth were extracted after three periods of clinical service and were examined, by means of scanning and transmission electron microscopy, for the status of the DCMs. SEM revealed a progressive degradation of the DCMs, becoming less dense after 3 to 5 years, losing structural integrity after 6 to 9 years, and partially disappearing after 10 to 12 years. TEM revealed evidence of collagenolytic activity within the DCMs, with loss of cross-banding and unraveling into microfibrils, and gelatinolytic activity that resulted in disintegration of the microfibrils. Bacterial colonization and the release of bacterial enzymes and of host-derived matrix metalloproteinases may contribute to the degradation of collagen fibrils in root dentin after clinical function.

Bacteria↗

In vivo and in vitro permeability of one-step self-etch adhesives.

Adhesive dentistry should effectively restore the peripheral seal of dentin after enamel removal. We hypothesize that non-rinsing, simplified, one-step self-etch adhesives are effective for minimizing dentin permeability after tooth preparation procedures. Crown preparations in vital human teeth were sealed with Adper Prompt, Xeno III, iBond, or One-Up Bond F. Epoxy resin replicas were produced from polyvinyl siloxane impressions for SEM examination. Dentin surfaces from extracted human teeth were bonded with these adhesives and connected to a fluid-transport model for permeability measurements and TEM examination. Dentinal fluid droplets were observed from adhesive surfaces in resin replicas of in vivo specimens. In vitro fluid conductance of dentin bonded with one-step self-etch adhesives was either similar to or greater than that of smear-layer-covered dentin. TEM revealed water trees within the adhesives that facilitate water movement across the polymerized, highly permeable adhesives. Both in vitro and in vivo results did not support the proposed hypothesis.

Acid Etching, Dental↗

Water-dependent interfacial transition zone in resin-modified glass-ionomer cement/dentin interfaces.

The function of the interfacial transition zone (absorption layer) in resin-modified glass-ionomer cements bonded to deep dentin remains obscure. This study tested the hypotheses that the absorption layer is formed only in the presence of water derived from hydrated dentin and allows for better bonding of resin-modified glass-ionomer cements to dentin. Ten percent polyacrylic acid-conditioned, hydrated, and dehydrated deep dentin specimens were bonded with 2 resin-modified glass-ionomer cements and sealed with resins to prevent environmental water gain or loss. A non-particulate absorption layer was identified over hydrated dentin only, and was clearly discernible from the hybrid layer when bonded interfaces were examined with transmission electron microscopy. This layer was relatively more resistant to dehydration stresses, and remained intact over the dentin surface after tensile testing. The absorption layer mediates better bonding of resin-modified glass-ionomer cements to deep dentin, and functions as a stress-relieving layer to reduce stresses induced by desiccation and shrinkage.

Compomers↗

Fluid movement across the resin-dentin interface during and after bonding.

This study evaluated the extent of water penetration through resin-dentin interfaces before and after being sealed with adhesives. Four adhesive resin systems (2 total-etch adhesives and 2 self-etching primer adhesives) were used in this study. Dentin disks were placed in a split-chamber device, and in situ fluid movement across dentin was measured, with and without physiological pressure, during bonding procedures or 24 hrs after bonding. The fluid movement across dentin occurs via dentin tubules after acid-etching. Large outward or inward fluid shifts across dentin were observed during air-drying and light-curing for resin application. The amount of fluid movement across resin-bonded dentin when total-etch adhesives were used was significantly greater than that with self-etching adhesives. The milder acid-etching effects of self-etching primers may retain hybridized smear plugs within the tubules that reduce outward fluid flow, resulting in superior dentin sealing.

Acid Etching, Dental↗

Dimensional changes in acid-demineralized dentin matrices following the use of HEMA-water versus HEMA-alcohol primers.

Although dried acid-etched dentin can be reexpanded by hydroxyethyl methacrylate (HEMA)/water primers, the primed dentin collapses when the water is evaporated. Experimental HEMA/alcohol primers should stiffen the matrix and permit less shrinkage when the solvent is evaporated. The purpose of this study was to test the hypotheses that matrix shrinkage induced by solvent evaporation from HEMA primers is inversely related to solvent-induced matrix stiffness. Dentine discs were prepared from midcoronal dentine of unerupted human third molars. After demineralization in 37% phosphoric acid, the specimens were placed in the well of a linear variable differential transformer instrument, which measures changes in the matrix height and stiffness by load displacement after the application of weights. This was done in their hydrated state after water had been applied, after drying with dry nitrogen gas, and after the application of 35 vol % HEMA-water, HEMA-methanol, HEMA-ethanol, or HEMA-propanol primers. The degree of reexpansion after the application of the primers to the dentine in the dried state was found to be highest using the HEMA-water primer, followed by HEMA-methanol and HEMA-ethanol, with the HEMA-propanol primer producing no expansion. However, when the solvents were evaporated the HEMA-water-treated specimens shrank the most, the HEMA-ethanol-treated specimens shrank an intermediate amount, and the HEMA-methanol-treated specimens shrank the least. The net result of expansion minus shrinkage produced by evaporation determines how much HEMA remains in the hybrid layer just prior to polymerization.

Acids↗

Optimizing filler content in an adhesive system containing pre-reacted glass-ionomer fillers.

OBJECTIVES: (1) To evaluate the optimal concentration of the calcium type pre-reacted glass-ionomer (PRG-Ca) fillers in experimental light-activated adhesives for bonding to tooth substrates and fluoride release; (2) to evaluate the polymerization reactivity of these experimental filled adhesives; and (3) to examine the ultrastructure of the resin-dentin interface bonded with the commercial version of this self-etching adhesive (Imperva Fluoro Bond, Shofu Inc., Kyoto, Japan). MATERIALS AND METHODS: PRG-Ca fillers were prepared from the acid-base reaction of calcium type fluoroaluminosilicate glass with poly(acrylic acid) in water. Different experimental light-cured adhesives were prepared, with 0-57wt% PRG-Ca fillers and 3wt% aerosil silica incorporated in a resin matrix. Twenty-four hours shear bond strengths to bovine enamel and dentin were assessed using the adhesive with/or without accelerated aging. The cumulative amount of fluoride released from the cured adhesives and differential scanning calorimetry (DSC) measurements were also conducted. 180-grit SiC paper polished human dentin disks were treated with Imperva Fluoro Bond that contains 17wt% PRG-Ca fillers and prepared for TEM examination. RESULTS: Increase in PRG-Ca filler content of experimental adhesives was highly correlated with the decrease in bond strengths to dentin (r=-0.96 to -0.99), the increase in cumulative fluoride release, (r=0.97) and the decrease in polymerization energy (cal/g) of the adhesives (r=-0.99) (p<0.001). A PRG-Ca content of 17wt% provided optimal bond strength to enamel and dentin after accelerated aging and fluoride release. TEM showed that salt-like matrices were present around the hydrogels and remnant glass cores of the PRG-Ca fillers. The commercial self-etching primer completely dissolved the smear layer and formed 2 micrometer thick hybrid layers in intact dentin. SIGNIFICANCE: The use of silanized PRG-Ca fillers provides good adhesion and a source of fluoride release in a commercially available self-etching adhesive system.

Analysis of Variance↗

Aging affects two modes of nanoleakage expression in bonded dentin.

Water sorption into resin-dentin interfaces precedes hydrolytic degradation. We hypothesized that these processes are morphologically manifested by the uptake of ammoniacal silver nitrate, which is thought to trace hydrophilic domains and water-filled channels within matrices. Water sorption is thought to be nonuniform and can be traced by the use of silver nitrate. Human teeth bonded with an experimental filled-adhesive were aged in artificial saliva (experimental) or non-aqueous mineral oil (control). Specimens retrieved for up to a 12-month period were immersed in 50 wt% ammoniacal silver nitrate and examined by transmission electron microscopy for identification of the changes in their silver uptake. Reticular silver deposits initially identified within the bulk of hybrid layers in the experimental group were gradually reduced over time, but were subsequently replaced by similar deposits that were located along the hybrid layer-adhesive interface. Silver uptake in water-binding domains of the adhesive layers increased with aging, resulting in water tree formation. These water-filled channels may act as potential sites for hydrolytic degradation of resin-dentin bonds.

Absorption↗

Effects of HEMA/solvent combinations on bond strength to dentin.

Re-expansion of dried demineralized dentin is required to optimize resin adhesion. This study tested the hypothesis that bond strengths to dentin depend upon the ability of experimental HEMA(2-hydroxy-ethyl-methacrylate)/solvent primers to re-expand the matrix. Dentin surfaces were acid-etched with 37% phosphoric acid for 20 sec, air-dried for 30 sec, primed with either 35/65% (v/v) HEMA/water, HEMA/methanol, HEMA/ethanol, or HEMA/propanol for 60 sec, and bonded with 4-META-TBBO(4-methacryloyloxyethyl trimellitate anhydride-tri-n-butyl borane) adhesive. After storage in water for 1 day at 37 degrees C, the samples were prepared for microtensile bond strength testing. We used transmission electron microscopy to measure the width of interfibrillar spaces in the hybrid layers. The HEMA/ethanol primer and the HEMA/propanol primer produced the highest and the lowest bond strengths, respectively (p < 0.05). Bond strengths were directly correlated with the width of the interfibrillar spaces (p < 0.05). Bond strengths are related to the ability of the primer to maintain the re-expansion of collapsed demineralized dentin matrix.

1-Propanol↗

Integrating oxalate desensitizers with total-etch two-step adhesive.

Compromised bonding of total-etch adhesives to dentin treated with oxalate desensitizers results from the interference of a surface layer of acid-resistant crystals of calcium oxalate. We hypothesize that effective tubular occlusion and dentin bonding may be simultaneously achieved by depleting dentin surfaces of calcium with acids before desensitizer application. Dentin specimens treated with 4 oxalate desensitizers before or after being acid-etched were bonded with a two-step adhesive. Microtensile bond strengths ( micro TBS) were significantly lower, compared with the control, when oxalates were used before the specimens were acid-etched; in contrast, when oxalates were used after acid-etching. micro TBS were similar to nonoxalate-treated controls. Dentin surfaces and tubular orifices were covered with a surface layer of crystals when desensitizers were applied to fractured dentin and smear-layer-covered dentin before specimens were acid-etched. However, when the dentin was acid-etched prior to the application of oxalate desensitizers, the crystals were largely limited to the subsurface of dentinal tubules, where they did not interfere with subsequent resin bonding.

Acid Etching, Dental↗

Comparison of pulse activation vs conventional light-curing on marginal adaptation of a compomer conditioned using a total-etch or a self-etch technique.

OBJECTIVES: This study investigated the effect of two factors: conditioning methods and light-curing techniques on the marginal adaptation of Dyract AP (Dentsply DeTrey, Germany). The 'pulse activation' curing technique was compared with a conventional light-curing technique for their effectiveness in reducing marginal gaps in restorations that were conditioned with three different protocols. MATERIALS AND METHODS: Cylindrical cavities, 3mm in diameter, were prepared in extracted human molar teeth. They were restored with Dyract AP using Prime&Bond NT (PBNT; Dentsply DeTrey) as the adhesive. Cavities were etched with: Conditioner36/PBNT (group 1), Non-Rinse Conditioner (NRC)/PBNT (group 2), and PBNT only (group 3). Either conventional or the 'pulse activation' technique was used for light-curing of the material. Epoxy resin replicas were obtained from longitudinal sections of the specimens, and the restoration-tooth interfaces were examined using scanning electron microscopy. Marginal qualities along the resin-dentin interfaces were further measured using image analysis and analyzed using nonparametric statistical methods. RESULTS: With the conventional curing technique, enamel margin fractures were frequently observed. Marginal gaps were found along the compomer-dentin interfaces irrespective of the conditioning protocol. A significantly lower percentage of gap-containing margins were found in cavities that were conditioned with 36% phosphoric acid. With the 'pulse activation' technique, no marginal gap was found along compomer-dentin interfaces that were etched with either Conditioner36 or NRC. More than 90% of the total margin length were excellent. No cohesive failure of enamel could be observed along cavosurface margins. SIGNIFICANCE: The 'pulse activation' curing technique significantly improves the marginal integrity of Dyract AP when Conditioner36/Prime&Bond NT and NRC/Prime&Bond NT are used as conditioning/bonding systems. The use of Prime&Bond NT without etching is not recommended, as marginal gaps are present irrespective of the curing techniques employed.

Acid Etching, Dental↗

Micro-tensile bond strengths to sclerotic dentin using a self-etching and a total-etching technique.

OBJECTIVES: To evaluate the in vitro regional micro-tensile bond strengths of a self-etching/self-priming adhesive system to sclerotic dentin, in the absence or presence of phosphoric acid conditioning. METHODS: Naturally-occurring, non-carious cervical lesions on extracted premolars were hand-cleaned with a slurry of pumice and chlorhexidine, then bonded without further cavity preparation. One group was bonded using Clearfil Liner Bond 2V (Kuraray Co. Ltd., Osaka, Japan). The other group was first conditioned with K-etchant; 40% phosphoric acid gel (Kuraray) prior to the application of the self-etching primer. Artificially prepared wedge-shaped cavities were also made in sound premolars and bonded with the two methods as controls. Resin composite build-ups were made using Clearfil Protect Liner F and AP-X resin composite (Kuraray). After storage in water for 24h, the teeth were sectioned into 0.7 x 0.7 mm composite-dentin beams along the occlusal and gingival walls, and at the apex of the lesions. The use of two conditioning methods, two substrate types, and three different locations yielded 10-14 beams for each of the 12 groups. After testing for the microTBS, representative beams that were stressed to failure were examined with SEM. Remaining fractured beams were demineralized and processed for TEM examination. Statistical analysis was performed using a three-way ANOVA and Student-Newman-Keuls tests. RESULTS: Regardless of the conditioning methods, bond strengths to sound dentin were significantly higher than to sclerotic dentin (P< 0.05). With sclerotic dentin, there was no significant difference for the conditioning methods used, except that K-etchant significantly improved the bond strength at the gingival aspect of the lesions. Fractographic analysis revealed that the self-etching primer could not etch beyond the surface hypermineralized layer of sclerotic dentin. Interfacial failure occurred along the surface of the mineralized intermicrobial matrix and/or hypermineralized layer. With the use of phosphoric acid, a hybrid layer was only seen when the surface layers were thin. Incompletely removed sclerotic casts were evident in both groups. SIGNIFICANCE: Removal of the surface layers of sclerotic dentin and/or conditioning with stronger acids may be beneficial to obtain stronger bonding to sclerotic dentin.

Acid Etching, Dental↗