Search PubMed⌕ Search

Biomedical subjects

F R Tay

Publications and source records attributed to F R Tay.

At least 19 recordsLinked to original sources

Hardness, elasticity, and ultrastructure of bonded sound and caries-affected primary tooth dentin.

Biomechanical properties of bonded dentin are important factors for resin restoration. We evaluated the hardness and elastic modulus of bonded sound and caries-affected primary tooth dentin using a one-step adhesive system, and observed the microstructure of the bonded interface. Six sound and six carious primary teeth were used. For sound teeth, flat occlusal dentin surfaces were prepared with a water-cooled high-speed diamond bur. For carious teeth, infected dentin was stained with a caries detector and removed with a water-cooled low-speed round steel bur and hand instruments. The prepared dentin was bonded with One-Up Bond F Plus (Tokuyama Dental Co., Tokyo, Japan). The resin-dentin interface and dentin beneath the interface were measured with a nano-indentation tester and observed with SEM and TEM. For both the carious and sound teeth, there was no significant difference between the hardness of the interfacial dentin and dentin 10-80 microm beneath the interface. However, the Young's modulus of the interfacial dentin was significantly lower than the dentin 40-80 microm (carious teeth) or 50-80 microm (sound teeth) beneath the interface. Both the hardness and Young's modulus of the interfacial dentin were not significantly different between the carious and sound teeth. Compared to the sound dentin, the hybrid layer on the caries-affected dentin was thicker and exhibited more complicated morphologic features. The thickness of the hybrid layers was generally less than 1 microm.

Dental Caries↗

Chlorhexidine preserves dentin bond in vitro.

Loss of hybrid layer integrity compromises resin-dentin bond stability. Matrix metalloproteinases (MMPs) may be partially responsible for hybrid layer degradation. Since chlorhexidine inhibits MMPs, we hypothesized that chlorhexidine would decelerate the loss of resin-dentin bonds. Class I preparations in extracted third molars were sectioned into two halves. One half was customarily restored (etch-and-rinse adhesive/resin composite), and the other was treated with 2% chlorhexidine after being acid-etched before restoration. Specimens were stored in artificial saliva with/without protease inhibitors. Microtensile bond strengths and failure mode distribution under SEM were analyzed immediately after specimens' preparation and 6 months later. With chlorhexidine, significantly better preservation of bond strength was observed after 6 months; protease inhibitors in the storage medium had no effect. Failure analysis showed significantly less failure in the hybrid layer with chlorhexidine, compared with controls after 6 months. In conclusion, this in vitro study suggests that chlorhexidine might be useful for the preservation of dentin bond strength.

Acid Etching, Dental↗

Evaluation of a new caries detecting dye for primary and permanent carious dentin.

OBJECTIVE: This study evaluated the clinical efficacy of a new caries detecting dye using a laser fluorescence device (DIAGNOdent). METHOD: Primary and permanent teeth with dentin caries were stained with Caries Check (CC), containing 1% acid red in polypropylene glycol (MW=300) or Caries Detector (CD), containing 1% acid red in propylene glycol (MW=76). Primary-CC, primary-CD, permanent-CC and permanent-CD groups were prepared. In the CC groups, stained dentin was completely removed. In the CD groups, pink-stained dentin was retained according to the manufacturers' instructions. Cavities before and after caries removal were measured with the DIAGNOdent. Data were analyzed using ANOVA and Fisher's PLSD multiple comparison test at alpha=0.05. Regression analyses were performed between DIAGNOdent readings and scores obtained from the clinical parameters. RESULTS: For all groups, there were no significant differences in the DIAGNOdent readings before treatment. The DIAGNOdent readings after caries removal were: primary-CC (16.0+/-17.6), primary-CD (9.6+/-5.2), permanent-CC (11.0+/-7.0) and permanent-CD (7.1+/-3.8). Significant differences were identified between the permanent-CC and primary-CD, and permanent-CC and permanent-CD subgroups but not for the primary subgroups. Correlation coefficients between DIAGNOdent readings and clinical parameters were low. CONCLUSIONS: When dentin stained with Caries Check was completely removed, the DIAGNOdent readings were higher than those recorded when palely-stained pink dentin was retained with the Caries Detector, with significant difference observed for the permanent teeth. Caries Check may be used clinically to avoid excessive removal of caries-affected or sound dentin in permanent teeth but not in primary teeth.

Child↗

The adhesion between fibre posts and composite resin cores: the evaluation of microtensile bond strength following various surface chemical treatments to posts.

AIM: To evaluate the influence of various surface treatments to fibre posts on the microtensile bond strength with different composite resins. METHODOLOGY: A total of 110 fibre posts were randomly divided into five groups, according to the surface pre-treatment performed. Group 1: immersion in 24% H(2)O(2) for 10 min and silanization for 60 s; group 2: immersion in 10% H(2)O(2) for 20 min and silanization for 60 s; group 3: immersion in 4% hydrofluoric acid gel for 60 s and silanization for 60 s; group 4: silanization of the post surface for 60 s and application of the bonding agent G-Bond; group 5: silanization of the post surface for 60 s (control group). After treatment, two posts were randomly selected from each group to evaluate the morphological aspect of the post surface with scanning electron microscopy. The remaining posts in each group were divided into five subgroups of five posts each, which differed in the type of composite resin used for the core build-up. Post-core strength were calculated and the differences among experimental groups were analysed with two-way anova and the Tukey test (alpha = 0.05). RESULTS: The post-core strengths achieved in groups 1 and 2 were significantly higher (P < 0.05), than those of groups 3, 4 and 5. The post-core strength in the control group was significantly lower (P < 0.05) than all other groups. CONCLUSIONS: Hydrogen peroxide and hydrofluoric acid both modified the surface morphology of fibre posts and with silane, significantly enhanced the interfacial strength between them and core materials.

Acrylic Resins↗

Reduced antigenicity of type I collagen and proteoglycans in sclerotic dentin.

Antigenic alterations to the dentin organic matrix may be detected by an immunohistochemical approach. We hypothesized that alterations in the antigenicity of type I collagen and proteoglycans occur in sclerotic dentin under caries lesions. Transverse sections were prepared from carious teeth in the sclerotic zone and normal hard dentin. A double-immunolabeling technique was performed on these sections, with anti-type I collagen and anti-chondroitin 4/6 sulfate monoclonal primary antibodies. We used gold-conjugated secondary antibodies to visualize the distribution of intact collagen fibrils and proteoglycans by high-resolution SEM. For sclerotic dentin, labeling densities were 19.57 +/- 3.01/microm2 for collagen and 9.84 +/- 2.62/microm2 for proteoglycans. For normal hard dentin, values were 35.20 +/- 2.73/microm2 and 17.03 +/- 1.98/microm2, respectively. Distribution of intact collagen fibrils and proteoglycans in sclerotic dentin was significantly lower than in normal hard dentin. Reductions in antigenicity from the organic matrix of sclerotic dentin under caries lesions raise concern about the potential of intrafibrillar remineralization.

Collagen Type I↗

Evaluation of a self-limiting concept in dentinal caries removal.

The mechanical removal of dentinal caries traditionally involves the use of tactile sensation and/or caries-indicating dyes. This study tested the hypothesis that self-limiting polymer burs are as effective as conventional carbide burs in creating substrates for dentin bonding. Carious dentin from extracted human molars was removed with carbide or polymer burs, with dental explorer hardness as the end-point for caries removal. Dentin substrates were bonded with etch-and-rinse or self-etch adhesives and prepared for microtensile bond testing and transmission electron microscopy. For each bur type, there was no difference in bond strength between adhesives. However, the polymer bur surface exhibited significantly lower bond strengths than the carbide bur, and both were lower than flat, non-carious dentin controls. TEM revealed areas of incompletely removed, denatured caries-infected dentin in the polymer bur specimens. These first-generation polymer burs might best be utilized for deep caries removal where pulpal exposure is a concern.

Analysis of Variance↗

Hydrolysis of functional monomers in a single-bottle self-etching primer--correlation of 13C NMR and TEM findings.

Self-etching primers/adhesives that combine acidic methacrylate monomers with water in a single bottle are hydrolytically unstable and require refrigeration to extend their shelf-lives. This study tested the null hypothesis that one year of intermittent refrigeration of a 4-MET-containing simplified self-etching primer does not result in hydrolytic changes that are identifiable by transmission electron microscopy and (13)C NMR spectroscopy. Human dentin was bonded with UniFil Bond immediately after being unpacked, or after one year of intermittent refrigeration at 4 degrees C. Fresh and aged primers were analyzed by NMR for chemical changes. Ultrastructural observations indicated that there was an augmentation in etching capacity of the aged adhesive that was not accompanied by resin infiltration or effective polymerization. New NMR peaks detected from the aged ethanol-based primer confirmed that degradation occurred initially via esterification with ethanol, followed by hydrolysis of both ester groups in the 4-MET. Hydrolysis of functional methacrylate monomers occurs despite intermittent refrigeration.

Acid Etching, Dental↗

Effects of resin hydrophilicity on dentin bond strength.

The purpose of this study was to determine if hydrophobic resins can be coaxed into dentin wet with ethanol instead of water. The test hypothesis was that dentin wet with ethanol would produce higher bond strengths for hydrophobic resins than would dentin wet with water. This study examined the microtensile bond strength of 5 experimental adhesives (50 wt% ethanol/50% comonomers) of various degrees of hydrophilicity to acid-etched dentin that was left moist with water, moist with ethanol, or air-dried. Following composite buildups, hourglass-shaped slabs were prepared from the bonded teeth for microtensile testing. For all 3 types of dentin surfaces, higher bond strengths were achieved with increased resin hydrophilicity. The lowest bond strengths were obtained on dried dentin, while the highest bond strengths were achieved when dentin was bonded moist with ethanol. Wet-bonding with ethanol achieved higher bond strengths with hydrophobic resins than were possible with water-saturated matrices.

Analysis of Variance↗

Electric-current-assisted application of self-etch adhesives to dentin.

The use of electric current during the application of etch-and-rinse adhesive systems has been recently claimed to increase bonding of etch-and-rinse adhesives by enhancing substrate impregnation. The null hypothesis tested in this study was that electrically assisted application has no effect on bond strength of self-etching bonding systems. Three self-etch adhesives (Protect-Bond, Xeno III, and Prompt L-Pop) were applied with the aid of an electric signal-generating device (ElectroBond) and tested vs. controls prepared with the same disposable sponges but without electric current. Specimens bonded under the influence of electric current exhibited increased microtensile bond strength compared with the controls (p<0.05). High-resolution SEM analysis showed that bonding under the influence of electricity reduced interfacial nanoleakage. It is speculated that resin infiltration may be improved by the attraction of polar monomers by an electric current or by modification of the dentin surface charges, resulting in better water substitution or evaporation.

Ammonia↗

Effect of load cycling and in vitro degradation on resin-dentin bonds using a self-etching primer.

The objective of this study was to evaluate the effect of in vitro degradation and mechanical loading on microtensile bond strength (MTBS) and microleakage (ML) of a resin composite to dentin using a self-etching primer adhesive [Clearfil SE Bond (SEB)] under two hydration statuses. Twenty-four flat dentin surfaces were divided in groups: 1) blot-dried, 2) air-dried. SEB was applied and resin buildups were performed with Tetric Ceram. Specimens were divided in four subgroups: a) sectioned into beams, b) load cycled, c) beams were immersed in NaOCl for 5 h, d) load cycled and immersed in NaOCl. Beams were tested in tension. For ML testing, 80 Class V cavities were prepared and molars divided in subgroups as described above (in group c and d, specimens were kept in distilled water for 1 year, instead of the 5-h NaOCl immersion). ML was assessed by dye penetration. Analysis of variance and multiple comparisons tests were used for MTBS. For ML, Mann-Whitney U and Wilcoxon matched pairs signed ranked were used (p<0.05). SEB applied to completely dehydrated dentin produced the highest MTBS, at 24-h evaluation. In vitro degradation always decreased MTBS, and fatigue loading only diminished MTBS on dehydrated dentin. Load cycling increased dye penetration on dentin margins. Degradation always increased ML in both enamel and dentin margins.

Dental Caries↗

Shear bond strength of Resilon to a methacrylate-based root canal sealer.

AIM: To evaluate the adhesive strength of Resilon to Next root canal sealant (Heraeus-Kulzer), a methacrylate-based root canal sealer, using a modified microshear bond testing design. METHODOLOGY: Flat Resilon surfaces of different roughnesses (smooth surface and surface roughness equivalent to 320-grit and 180-grit) were prepared by compression moulding for bonding to the sealer and compared with a composite control. The shear strength data were statistically analysed using Kruskal-Wallis one-way anova on ranks and Dunn's multiple comparison tests (alpha = 0.05). After shear testing, fractured specimens were examined using a field emission-scanning electron microscope for detailed analysis of the failure modes. RESULTS: The composite control exhibited significantly higher mean shear strength (7.62 MPa) that was 4.4-4.7 times those of the Resilon groups (1.64-1.74 MPa; P < 0.001). Increasing the surface roughness of the Resilon surface did not contribute to further improvement in shear bond strength for this methacrylate-based sealer (P > 0.05). Failure modes in the composite control were cohesive and mixed failures, while those in the Resilon groups were predominantly adhesive failures, with a small percentage of mixed failures. Ultrastructural evidence of phase separation of polymeric components could be identified in Resilon. Both intact, non deformed and plastically deformed Resilon surfaces could be observed in specimens that exhibited adhesive failures. CONCLUSION: The low shear strength of Resilon to a methacrylate-based sealer compared with a composite control suggests that the amount of dimethacrylate incorporated in this filled, polycaprolactone-based thermoplastic composite may not yet be optimized for effective chemical coupling to methacrylate resins.

Analysis of Variance↗

In vivo fluid movement through dentin adhesives in endodontically treated teeth.

Fluid transudation through simplified dentin adhesives can occur in bonded vital crown dentin, since these adhesives behave as permeable membranes after polymerization. The effect of adhesive permeability in endodontically treated teeth is unknown. This study examined the hypothesis that in vivo fluid movement through simplified adhesives occurs when they are applied to root canals. Dowel spaces were prepared in endodontically treated teeth with single root canals. Six adhesives were applied to the intra-radicular dentin of canal walls. Impressions were obtained with polyvinyl siloxane, and replicas were fabricated with the use of polyether impression material. Replica hemisections were gold-coated for SEM examination. Fluid transudation was evident on the adhesive surfaces of all simplified total-etch and self-etch adhesives. Conversely, most of the specimens bonded with the control three-step total-etch adhesive were devoid of fluid droplets. Permeability of simplified adhesives results in water movement, even in root-treated dentin. This may adversely affect the coupling of auto-/dual-cured resin cements.

Acid Etching, Dental↗

Ultrastructural correlates of in vivo/in vitro bond degradation in self-etch adhesives.

The morphologic correlates of bond degradation in self-etching primers have not been fully elucidated. We hypothesized that there is no difference between the mechanism of degradation of self-etching primers in vivo and in vitro. Class I cavities prepared in vivo in 24 caries-free human molars were bonded with Clearfil SE Bond or Clearfil Protect Bond, and restored with resin composites. Eight teeth were extracted after 24 hrs, and the rest after 1 yr. The same protocol was repeated in vitro with extracted molars. Degradation of resin-dentin bonds was assessed by microtensile bond testing and TEM of interfaces after tracer immersion. Both in vivo and in vitro bond strengths decreased with time for SE Bond but not for Protect Bond, with more pronounced water treeing observed in the former adhesive under both aging conditions. There is no difference between the mechanism of degradation of self-etch adhesives in vivo or in vitro.

Analysis of Variance↗

Water concentration in self-etching primers affects their aggressiveness and bonding efficacy to dentin.

Water is required to ionize acid resin monomers for demineralization of tooth substrates. We tested the null hypothesis that altering the water concentration in two-step self-etching primers has no effect on their aggressiveness and bonding efficacy to dentin. Five experimental self-etching primers were prepared with resin-water-ethanol volume ratios of 9-0-1, 8-1-1, 7-2-1, 5-4-1, and 3-6-1. They were applied to smear-layer-covered dentin, followed by a bonding resin and composite build-ups for microtensile bond testing and TEM examination of tracer penetration. Increasing water concentration from 0-60 vol% improved acidic monomer ionization that was manifested as increasing hybrid layer thickness. However, significantly higher bond strength was observed in the 7-2-1 group, with minimal nanoleakage in the corresponding hybrid layer. When self-etching primers are formulated, a balance must be achieved to provide sufficient water for adequate ionization of the acidic monomers, without lowering the resin concentration too much, to optimize their bonding efficacy to dentin.

Acid Etching, Dental↗

Incompatibility of oxalate desensitizers with acidic, fluoride-containing total-etch adhesives.

The use of oxalate desensitizers on acid-etched dentin prior to adhesive application can result in subsurface tubular occlusion by calcium oxalate crystals. However, the solubility of calcium oxalate increases in acidic solution. We hypothesized that total-etch adhesives can, depending upon their pH, interact with oxalate-desensitizer-treated dentin in an adverse manner. Acid-etched human dentin treated with 2 oxalate desensitizers (BisBlock and Super Seal) was bonded with 4 simplified total-etch adhesives: One-Step (OS), Single Bond (SB), OptiBond Solo Plus (OB), and Prime&Bond NT (PB). Composite-dentin beams were examined by SEM and TEM, both of which revealed numerous spherical globules on OB- and PB-bonded, desensitizer-treated dentin, but not in OS or SB samples. Bond strengths produced by OB and PB were significantly lower in oxalate-treated specimens than those produced by OS or SB. These surface globules may have interfered with hybridization of demineralized dentin with OB and PB resins and caused compromised bond strengths.

Analysis of Variance↗

Chlorhexidine arrests subclinical degradation of dentin hybrid layers in vivo.

The recent paradigm that endogenous collagenolytic and gelatinolytic activities derived from acid-etched dentin result in degradation of hybrid layers requires in vivo validation. This study tested the null hypothesis that there is no difference between the degradation of dentin bonded with an etch-and-rinse adhesive and that in conjunction with chlorhexidine, an MMP inhibitor, applied after phosphoric-acid-etching. Contralateral pairs of bonded Class I restorations in primary molars of clinical subjects were retrieved after a six-month period of intra-oral functioning and processed for transmission electron microscopy. Hybrid layers from the chlorhexidine-treated teeth exhibited normal structural integrity of the collagen network. Conversely, abnormal hybrid layers were seen in the control teeth, with progressive disintegration of the fibrillar network, to the extent that it was beyond detection by collagen staining. Self-destruction of collagen matrices occurs rapidly in resin-infiltrated dentin in vivo and may be arrested with the use of chlorhexidine as an MMP inhibitor.

Acid Etching, Dental↗

Tubular occlusion prevents water-treeing and through-and-through fluid movement in a single-bottle, one-step self-etch adhesive model.

Water entrapment occurs at resin-dentin interfaces of one-step self-etch adhesives. We hypothesized that by preventing water fluxes from dentin, any water entrapment would be attributed to incomplete removal of adhesive solvents. We tested this hypothesis by bonding to transparent carious dentin containing occluded dentinal tubules. An experimental single-bottle, one-step self-etch adhesive was applied to flat surfaces of caries-affected dentin surrounded by sound dentin, with or without pulpal pressure. Resin-dentin interfaces were examined with TEM after silver-impregnation. Although caries-affected dentin was highly porous, adhesive layers were devoid of silver deposits when tubules were occluded. Conversely, variable extents of water-treeing and water-droplets were identified from adhesive layers in bonded sound dentin. Water-treeing and water-droplet formation, being manifestations of evaporative and convective water fluxes, can be eliminated during bonding to occluded transparent carious dentin. However, the highly porous nature of this clinically relevant substrate after bonding may lead to potentially undesirable consequences.

Acid Etching, Dental↗

Tensile strength of mineralized/demineralized human normal and carious dentin.

The bond strengths of resins to caries-affected dentin are low. This could be due to weakened organic matrix. The purpose of this work was to determine if the ultimate tensile strength (UTS) of excavated carious dentin is weaker than that of normal dentin. Soft caries was excavated from extracted human molars, and the tooth was vertically sectioned into slabs. Each slab was trimmed to an hourglass shape, parallel or perpendicular to the tubule direction. Half of the specimens were mineralized, while the other half were completely demineralized in EDTA. ANOVA on ranks showed that the three-factor interactions (mineralization, caries, tubule direction) were all significant (p < 0.0001), indicating that mineralization and tubule direction gave different UTS results in normal and caries-affected dentin. No significant differences were seen between the UTS of normal and and that of caries-affected demineralized dentin in the parallel or perpendicular group. The matrix of demineralized caries-affected dentin was as strong as that of normal demineralized dentin when tested in the same direction.

Chelating Agents↗