Search PubMed⌕ Search

Biomedical subjects

F Maillard

Publications and source records attributed to F Maillard.

At least 19 recordsLinked to original sources

Ru-decorated Pt surfaces as model fuel cell electrocatalysts for CO electrooxidation.

This feature article concerns Pt surfaces modified (decorated) by ruthenium as model fuel cell electrocatalysts for electrooxidation processes. This work reveals the role of ruthenium promoters in enhancing electrocatalytic activity toward organic fuels for fuel cells, and it particularly concerns the methanol decomposition product, surface CO. A special focus is on surface mobility of the CO as it is catalytically oxidized to CO(2). Different methods used to prepare Ru-decorated Pt single crystal surfaces as well as Ru-decorated Pt nanoparticles are reviewed, and the methods of characterization and testing of their activity are discussed. The focus is on the origin of peak splitting involved in the voltammetric electrooxidation of CO on Ru-decorated Pt surfaces, and on the interpretative consequences of the splitting for single crystal and nanoparticle Pt/Ru bimetallic surfaces. Apparently, screening through the literature allows formulating several models of the CO stripping reaction, and the validity of these models is discussed. Major efforts are made in this article to compare the results reported by the Urbana-Champaign group and the Munich group, but also by other groups. As electrocatalysis is progressively more and more driven by theory, our review of the experimental findings may serve to summarize the state of the art and clarify the roads ahead. Future studies will deal with highly dispersed and reactive nanoscale surfaces and other more advanced catalytic materials for fuel cell catalysis and related energy applications. It is expected that the metal/metal and metal/substrate interactions will be increasingly investigated on atomic and electronic levels, with likewise increasing participation of theory, and the structure and reactivity of various monolayer catalytic systems involving more than two metals (that is ternary and quaternary systems) will be interrogated.

Journal Article↗

Cervical assessment at 22 and 27 weeks for the prediction of spontaneous birth before 34 weeks in twin pregnancies: is transvaginal sonography more accurate than digital examination?

OBJECTIVES: This study compared the accuracy of ultrasound cervical assessment (cervical length and cervical index) and digital examination (Bishop score and cervical score) in the prediction of spontaneous birth before 34 weeks in twin pregnancies. METHODS: In a prospective multicenter study, digital examination and transvaginal sonography were performed consecutively in twin pregnancies attending for routine sonography at either 22 weeks (175 women) or 27 weeks (153 women). The digital examination took place first, and the Bishop score and cervical score (cervical length minus cervical dilatation) were calculated. Ultrasound measurements were then made of cervical length and funnel length to yield the cervical index (1 + funnel length/cervical length). The association between each variable and delivery before 34 weeks was tested by the Mann-Whitney U-test. The receiver-operating characteristics (ROC) curves of the ultrasound and digital indicators were determined for both gestational age periods, and the areas under the ROC curves compared. The best cut-off values for each indicator were used to determine predictive values for delivery before 34 weeks. RESULTS: The median gestational age at delivery among the women included in the 22-week examination period was 36.0 (range, 21-40) weeks; 10.9% (19) gave birth spontaneously before 34 weeks. The median cervical length was 40 (range, 6-65) mm. All four parameters were predictors of delivery before 34 weeks. The areas under the ROC curves for cervical index, cervical length, Bishop score and cervical score did not differ significantly. The median gestational age at delivery among the women in the 27-week examination period was 36.0 (range, 27-40) weeks; 9.2% (14) gave birth spontaneously before 34 weeks. The median cervical length was 35 (range, 1-57) mm. All parameters except the Bishop score were predictors of delivery before 34 weeks. The likelihood ratio of the positive and negative tests for cervical length < or = 25 mm was 5.4 (range, 3.2-9.0) and 0.3 (range, 0.1-0.7), respectively, compared with 2.3 (range, 1.3-4.2) and 0.6 (range, 0.3-1.1), respectively, for cervical score < or = 1. The area under the curve for the cervical index was significantly larger than that for the Bishop score (P = 0.008) or cervical score (P = 0.02). CONCLUSION: Transvaginal sonography predicted spontaneous delivery before 34 weeks better than digital examination at the 27-week but not the 22-week examination.

Cervical Ripening↗

Interleukin-8 mRNA in vaginal secretions: a prenatal marker of congenital infection in case of preterm labor with intact membranes.

OBJECTIVE: To study whether interleukin-8 (IL-8) mRNA in vaginal secretions is associated with congenital infection and preterm delivery in the case of preterm labor with intact membranes. METHODS: This prospective clinical study in a tertiary referral center included 280 patients who gave birth to 360 infants from 1997 through 1999. IL-8 mRNA in vaginal secretions was determined with reverse transcriptase polymerase chain reaction. Logistic regression was used to examine the association between vaginal IL-8 mRNA and congenital infection independently of the time of birth. Main outcome measures were congenital infection and delivery before 37 and 33 weeks' gestation. RESULTS: A total of 100 women (100/280 (35.7%)) gave birth before 37 weeks. A total of 54 children (54/360 (15%)) had congenital infection. IL-8 mRNA in vaginal secretions was associated with delivery within 14 days of the sampling (24 (15.6%) vs. 7 (5.6%) p < 0.01), but not with delivery within 48 h, 7 days (p = 0.07) or before 37 or 33 weeks. There were more congenital infections in the group with detectable IL-8 mRNA (37 (19.3%) than in the negative group (17 (10.1%); p < 0.05). IL-8 mRNA was associated with congenital infection independently of the time of birth (OR: 2.6 (1.3-5.1)). This test had a sensitivity for predicting neonatal infection of 69%. Its specificity was 49%, its positive predictive value 19%, and its negative predictive value 90%. CONCLUSION: IL-8 mRNA could be a prenatal noninvasive vaginal marker of congenital infection.

Adult↗

Size effects on reactivity of Pt nanoparticles in CO monolayer oxidation: the role of surface mobility.

In the present paper we study the reactivity of model Pt nanoparticles supported on glassy carbon. The particle size effect is rationalized for CO monolayer oxidation exploring electrochemical methods (stripping voltammetry and chronoamperometry) and modelling. Significant size effects are observed in the particle size interval from ca. 1 to 4 nm, including the positive shift of the CO stripping peak with decreasing particle size and a pronounced asymmetry of the current transients at constant potential. The latter go through a maximum at low COads conversion and exhibit tailing, which is the longer the smaller the particle size. Neither mean field nor nucleation & growth models give a coherent explanation of these experimental findings. We, therefore, suggest a basic model employing the active site concept. With a number of reasonable simplifications a full analytical solution is obtained, which allows a straightforward comparison of the theory with the experimental data. A good correspondence between experiment and theory is demonstrated. The model suggests restricted COads mobility at Pt nanoparticles below ca. 2 nm size, with the diffusion coefficient strongly dependent on the particle size, and indicates a transition towards fast diffusion when the particle size exceeds ca. 3 nm. Estimates of relevant kinetic parameters, including diffusion coefficient, reaction constant etc. are obtained and compared to the literature data for extended Pt surfaces.

Journal Article↗

Survival of very preterm infants: Epipage, a population based cohort study.

OBJECTIVE: To evaluate the outcome for all infants born before 33 weeks gestation until discharge from hospital. DESIGN: A prospective observational population based study. SETTING: Nine regions of France in 1997. PATIENTS: All births or late terminations of pregnancy for fetal or maternal reasons between 22 and 32 weeks gestation. MAIN OUTCOME MEASURE: Life status: stillbirth, live birth, death in delivery room, death in intensive care, decision to limit intensive care, survival to discharge. RESULTS: A total of 722 late terminations, 772 stillbirths, and 2901 live births were recorded. The incidence of very preterm births was 1.3 per 100 live births and stillbirths. The survival rate for births between 22 and 32 weeks was 67% of all births (including stillbirths), 85% of live births, and 89% of infants admitted to neonatal intensive care units. Survival increased with gestational age: 31% of all infants born alive at 24 weeks survived to discharge, 78% at 28 weeks, and 97% at 32 weeks. Survival among live births was lower for small for gestational age infants, multiple births, and boys. Overall, 50% of deaths after birth followed decisions to withhold or withdraw intensive care: 66% of deaths in the delivery room, decreasing with increasing gestational age; 44% of deaths in the neonatal intensive care unit, with little variation with gestational age. CONCLUSION: Among very preterm babies, chances of survival varies greatly according to the length of gestation. At all gestational ages, a large proportion of deaths are associated with a decision to limit intensive care.

Birth Weight↗

Bacterial vaginosis: prevalence and predictive value for premature delivery and neonatal infection in women with preterm labour and intact membranes.

OBJECTIVES: Assess the predictive values of bacterial vaginosis (BV) for preterm delivery (PD) and neonatal infection and compare them with standard markers of infection among women with preterm labour (PL). STUDY DESIGN: Prospective blinded study in a tertiary referral centre in Paris. Women hospitalised for PL with intact membranes at a term between 24 and 34 weeks were included. Vaginal fluid, collected at inclusion was Gram-stained, scored, and interpreted according to Nugent's criteria. RESULTS: Out of 354 women tested, 254 had normal flora (72.3%), 76 intermediate (21.7%) and 24 BV (6.8%). A history of spontaneous miscarriage after 14 weeks was the only risk factor significantly associated with BV. BV was not significantly associated with PD<35 weeks or neonatal infection. Very preterm delivery (before 33 weeks) was significantly associated with the flora grade (P=0.02): women with normal, intermediate and abnormal flora, respectively had 27 (10.6%), 14 (18.4%) and 6 (25.0%) births before 33 weeks. Of the markers tested, the highest risk of very preterm delivery was associated with BV (odds ratio 2.95, 95% CI (1.1-0.8.1)) and CRP>20mg/dl (4.23 95% CI (1.8-9.7)). Predictive value of BV for preterm birth before 33 weeks were: sensitivity 12.8%, specificity 95.0%, positive predictive value 35.3%, and negative predictive value 84.3%. CONCLUSIONS: The frequency of BV and its association with PD are probably very variable and must be interpreted differently from one population to another. While we found an association between BV results and delivery before 33 weeks, the predictive value of BV was disappointing. Although these findings reinforce the importance of a useful marker of subclinical infection, the usefulness of testing for BV in women with PL has not been demonstrated.

Abortion, Spontaneous↗

Biochemical markers (without markers of infection) of the risk of preterm delivery. Implications for clinical practice.

BACKGROUND: New biochemical markers for the risk of spontaneous preterm birth (SPB) give a more precise and earlier diagnosis than the usual ones. We reviewed the data about the principal markers. RESULTS: Using studies with good methodology and a large number of subjects, we observe that the predictive value of these new markers is somewhat higher than those of the usual markers. Fetal fibro-nectin (FNf) and cervical ultrasound undeniably improve the identification of patients at risk of preterm birth, both in the general population and in these threatened preterm delivery. However no management has yet been demonstrated efficacious, especially in a general population so any recommendations for their systematic utilisation is premature. Other biochemical markers (salivary estriol, serum CRH, etc.) are still under assessment and should not be used outside research protocols. IMPLICATION FOR PRACTICE: It is appropriate to integrate either FNf or cervical ultrasound into daily clinical practice for patients with signs of preterm labor. These new indicators are of special use when the diagnosis is uncertain with the standard markers (uterine contractions, digital examination). Among these patients, they should reduce the number of hospitalizations and of useless treatments, because of their good negative predictive value. At the same time, for patients poorly 'labeled' by the clinical examination, they should allow the application of intensive management (intravenous tocolysis, corticoids, in utero transfers). CONCLUSION: Future studies should evaluate these tests in everyday practice. The objective is not to predict preterm birth but to prevent either it or its negative consequences. This goal will be met when we have an effective treatment, without associated adverse effects, to offer patients after a positive test result.

Biomarkers↗

Neurological and physical maturation in normal growth singletons from 37 to 41 weeks' gestation.

An evaluator blinded to gestational age (GA) assessed a cohort of 397 singletons born at between 37 and 41 week's gestation, by looking at 11 criteria exploring neurological maturity and 12 criteria exploring physical maturity. The analysis of correlation coefficients shows various degrees of association between GA and each of the criteria examined. A highly significant correlation (p < 0.001) was found for 4 neurological criteria defining passive tone in limbs and sucking reflex. The activity of flexor muscles of the neck and crossed extension reflex were also associated with maturity but weakly (p < 0.01). A highly significant correlation (p < 0.001) was found for 8 of the physical criteria, skin colour and texture, lanugo, ear firmness, genitalia, breast size, nipple formation and plantar skin creases. Oedema, skull firmness and ear form were also associated but weakly. With multivariate analysis combining the neurological and physical criteria, predictive values ranked in the following order: 1) plantar skin, 2) breast size, 3) sucking reflex, 4) scarf sign, 5) skin colour, 6) genitalia, 7) popliteal angle, 8) return to flexion of forearms, 9) dorsiflexion angle. In conclusion, a score based on physical and neurological criteria is associated with duration of pregnancy (r2 = 0.32) between 37 and 41 weeks' gestation. Such an instrument allows us to study fetal maturity as a variable independent of GA, and therefore makes it possible to identify various influences that may modify maturational rate during the last weeks of pregnancy.

Cohort Studies↗

[Clinical importance of fetal pulse oximetry. I. Methodological evaluation. Multicenter study. French Study Group on Oximetry of Fetal Pulse].

OBJECTIVE: To evaluate the feasibility of intrapartum fetal pulse oximetry, the distribution of fetal oxygen saturation values, and the relation with the neonatal outcome in a population with an abnormal fetal heart rate (FHR). STUDY DESIGN: A prospective multicenter observational study, from June 1994 to November 1995. Fetal oxygen saturation was continuously recorded using a Nellcor N-400 fetal pulse oximeter in case of abnormal FHR during labor. Simultaneous readings of fetal oxygen saturation and of fetal blood analysis (FBA) were obtained at inclusion and before birth. Feasibility, adverse effects, distribution of fetal oxygen saturation values and relation with neonatal outcome were assessed. RESULTS: 74 patients were included. From 172 attempted sensor placements, the procedure was impossible in three cases and fetal oxygen saturation values were obtained in 164 cases (95.3%). Physicians considered sensor placement an easier task than FBA attempt (easy in 87.5% vs 78.9% for FBA, p = 0.03). The mean reliable signal time (+/- SD) was 64.7 +/- 32% during the first stage. There were no serious adverse effects in the study population. The mean fetal oxygen saturation during the first stage of labor was 42.2 +/- 8.0% (10th-90th centile range: 30-53%). Fetal oxygen saturation was significantly correlated with scalp pH (r = 0.29; p = 0.01) but not with neonatal umbilical artery pH or gas values. There was a significant association between a low fetal oxygen saturation (< 30%) and a poor neonatal condition. CONCLUSION: The feasibility of fetal pulse oximetry is satisfactory in clinical practice. It is easy to use and provides a fair rate of recorded values, even in a population with suspicion of fetal distress. A low fetal oxygen saturation is significantly associated with an abnormal neonatal outcome.

Adult↗

[Clinical importance of fetal pulse oximetry. II. Comparative predictive values of oximetry and scalp pH. Multicenter study].

OBJECTIVE: To compare the predictive value of intrapartum fetal pulse oximetry to that of fetal blood analysis for an abnormal neonatal outcome in case of abnormal fetal heart rate (FHR). STUDY DESIGN: A prospective multicenter observational study, from June 1994 to November 1995. Fetal oxygen saturation was continuously recorded using a Nellcor N-400 fetal pulse oximeter in case of abnormal FHR during labor. Simultaneous readings of fetal oxygen saturation and fetal blood analysis obtained before birth, i.e. either at full dilatation, or before cesarean section when indicated, were compared with the neonatal status. The criteria for an abnormal neonatal outcome were 1) an umbilical arterial blood pH < or = 7.15 and 2) a combined variable including: 5 min. Apgar score < or = 7, umbilical arterial pH < or = 7.15, secondary respiratory distress, transfer in a neonatal care unit, or neonatal death. RESULTS: At a 7.20 threshold for fetal scalp pH, and 30% for fetal oxygen saturation (i.e. the tenth centile in the study population), the predictive value of fetal pulse oximetry was similar to that of fetal blood analysis for an arterial umbilical pH < or = 7.15, and for an abnormal neonatal outcome (positive predictive value 56% vs 55%, negative predictive value 81% vs 82%, sensitivity 29% vs 35%, and specificity 93% vs 91% respectively). The receiver operating curve showed similar performance of either technique for cut-off values < or = 7.20 for fetal blood pH and < or = 30% for fetal oxygen saturation, whereas fetal pulse oximetry became superior at higher thresholds. CONCLUSION: The predictive value of intrapartum fetal pulse oximetry can be favorably compared with that of fetal blood analysis. Randomized controlled management trials can now be performed to assess potential clinical benefits of this new tool.

Female↗

Multicenter study on the clinical value of fetal pulse oximetry. I. Methodologic evaluation. The French Study Group on Fetal Pulse Oximetry.

OBJECTIVE: Our purpose was to evaluate the feasibility of intrapartum fetal pulse oximetry, the distribution of fetal oxygen saturation values, and the relationship with the neonatal outcome in a population with an abnormal fetal heart rate. STUDY DESIGN: A prospective multicenter observational study was performed from June 1994 to November 1995. Fetal oxygen saturation was continuously recorded with use of a Nellcor N-400 fetal pulse oximeter in case of an abnormal fetal heart rate during labor. Simultaneous readings of fetal oxygen saturation and fetal blood analysis were obtained at inclusion and before birth. Feasibility, adverse effects, distribution of fetal oxygen saturation values, and relationship with neonatal outcome were assessed. RESULTS: One hundred seventy-four patients were included. From 172 attempted sensor placements, the procedure was impossible in three cases and fetal oxygen saturation values were obtained in 164 cases (95.3%). Physicians considered sensor placement an easier task than an attempt at fetal blood analysis (easy in 87.5% vs 78.9% for fetal blood analysis, p = 0.03). The mean reliable signal time (+/- SD) was 64.7% +/- 32% during the first stage. There were no serious adverse effects in the study population. The mean fetal oxygen saturation during the first stage of labor was 42.2% +/- 8.0% (10th to 90th percentile range 30% to 53%). Fetal oxygen saturation was significantly correlated with scalp pH (r = 0.29, p = 0.01) but not with neonatal umbilical artery pH or gas values. There was a significant association between low fetal oxygen saturation (< 30%) and poor neonatal condition. CONCLUSION: The feasibility of fetal pulse oximetry is satisfactory in clinical practice. It is easy to use and provides a fair rate of recorded values, even in a population with suspicion of fetal distress. A low fetal oxygen saturation is significantly associated with an abnormal neonatal outcome.

Adult↗

Multicenter study on the clinical value of fetal pulse oximetry. II. Compared predictive values of pulse oximetry and fetal blood analysis. The French Study Group on Fetal Pulse Oximetry.

OBJECTIVE: Our purpose was to compare the predictive value of intrapartum fetal pulse oximetry with that of fetal blood analysis for an abnormal neonatal outcome in case of an abnormal fetal heart rate. STUDY DESIGN: A prospective multicenter observational study was conducted from June 1994 to November 1995. Fetal oxygen saturation was continuously recorded with a Nellcor N-400 fetal pulse oximeter in case of an abnormal fetal heart rate during labor. Simultaneous readings of fetal oxygen saturation and fetal blood analysis obtained before birth (i.e., either at full dilatation or before cesarean section when indicated) were compared with the neonatal status. The criteria for an abnormal neonatal outcome were (1) an umbilical arterial blood pH < or = 7.15 and (2) a combined variable including 5-minute Apgar score < or = 7, umbilical arterial pH < or = 7.15, secondary respiratory distress, transfer in a neonatal care unit, or neonatal death. RESULTS: At a 7.20 threshold for fetal scalp pH and 30% for fetal oxygen saturation (i.e., the 10th percentile in the study population), the predictive value of fetal pulse oximetry was similar to that of fetal blood analysis for an arterial umbilical pH < or = 7.15 and for an abnormal neonatal outcome (positive predictive value 56% vs 55%, negative predictive value 81% vs 82%, sensitivity 29% vs 35%, and specificity 93% vs 91%, respectively). The receiver-operator characteristic curve showed similar performance of either technique for cutoff values < or = 7.20 for fetal blood pH and < or = 30% for fetal oxygen saturation, whereas fetal pulse oximetry became superior at higher thresholds. CONCLUSION: The predictive value of intrapartum fetal pulse oximetry can be favorably compared with that of fetal blood analysis. Randomized controlled management trials can now be performed to assess potential clinical benefits of this new tool.

Apgar Score↗

[Evaluation of urinary rapid strip-tests for screening of urinary infection in pregnant women].

Repeated screening for asymptomatic bacteriuria using a reagent strip-test was conducted in a population of 859 pregnant women. The women performed 4,125 tests at home, and 2,867 tests were performed by the nursing staff at the antenatal clinics. The tests done by the women at home had a higher predictive value than the tests done in the antenatal clinics (24% versus 10%). The sensitivity was 47%, specificity 90% and negative predictive value 98.8%. The tests performed by the women at home were well accepted and detected.

Ambulatory Care↗

Epidemiologic survey of patients treated with growth hormone in France in the period 1959-1990: preliminary results.

Because the delivery of growth hormone (GH) was centralized from 1977 in France, it has been possible to conduct, during the second half of 1990, a nationwide survey of the health status of patients treated with GH from the year 1959. A questionnaire regarding the 5,546 patients recorded for the period 1959-1990 was sent to the prescribers or the patients. 5,418 more or less completely documented reports were obtained. The mean age of the patients at the onset of GH treatment was 11.0 +/- 4.1 years. 1,937 of them had at this time some important disease associated with GH deficiency. The mean duration of treatment was 3.99 +/- 3.05 years. 3,446 patients were still under follow-up. Very recent information (1990-1991) was given for 82.7% of patients, less recent data (1985-1989) for 13.4%. For 3.9%, no data beyond 1985 were obtained. 77 patients had died, 38 from neoplastic disease (mainly recurrence of a primary malignancy), 10 from accident, 3 by suicide, 7 with neurological disease [only 1 case of Creutzfeldt-Jakob disease (CJD) was reported at the time of the survey], the others from various causes. No abnormal frequency of posttreatment leukemia, lymphoma, malignancies, hip diseases, glucose intolerance or other disease focusing attention, was found in the survey. From the time when this survey was completed (December 1990) to that of this report (May 1992), other cases of CJD have been reported in France: 3 ascertained, 7 clinically resembling but not yet certain. These 10 patients were treated for complete GH deficiency, 6 of congenital or neonatal cause and 4 after neurosurgery.(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗

Combination ultrafiltration and 6 M urea treatment of human growth hormone effectively minimizes risk from potential Creutzfeldt-Jakob disease virus contamination.

Although genetically engineered human growth hormone (hGH) is now commercially available, native pituitary-derived hGH is still used by physicians in many countries for the treatment of hormone deficiency states. We describe a method using ultrafiltration and 6 M urea that reduced infectivity in human pituitary tissue that had been deliberately contaminated with scrapie virus (an animal analogue of human Creutzfeldt-Jakob disease virus) from an initial level of 10(9.7) infectious units to just 5 infectious units. Based on estimates of the frequency of contamination and infectivity levels in batches of human pituitaries, the use of this protocol to prepare GH from cadaveric human glands yields a calculated probability of exposure to a contaminated vial of not greater than 1 in 3.2 million recipients; therefore, native hormone prepared by this method may be considered to be essentially risk-free. The same methodology may be useful in the preparation of other hormones, such as prolactin, for which no synthetic substitutes are currently available, as well as biological products derived from sheep or cattle, that may be infected with scrapie or bovine spongiform encephalopathy.

Animals↗

[Characteristics of human growth hormone produced by genetically engineered mammalian cells].

Saizen is human growth hormone produced by mammalian cells by genetic engineering. It is identical with hypophyseal GH as regards various physical and chemical parameters. A number of tests did not reveal an alien protein at the 1 ppm level, nor the presence of viruses, and the DNA level is below the detection range. According to these results Saizen is a highly purified growth hormone.

Growth Hormone↗

Zopiclone, the third generation hypnotic: a clinical overview.

Effective and safe hypnotics exist especially since the introduction of benzodiazepines (BZD) which appeared to bring major advantages over barbiturates. Ideally a new hypnotic should induce and maintain sleep without producing residual effect during the day and should be devoid of abuse and dependence potential. Zopiclone is a new hypnotic belonging to the cyclopyrrolone chemical class. Its elimination half-life is 5 to 6 h, no accumulation exists upon repeated administration, and its pharmacokinetic profile is not substantially modified in elderly and renal failure patients. Placebo-controlled studies have shown that zopiclone 7.5 mg is an effective hypnotic, and that it can improve all sleep variables in insomniacs. Its effects on sleep stages differ from those observed with BZD hypnotics: REM sleep is substantially unaffected by zopiclone and slow wave sleep is either unaffected or increased. Objective and subjective measurements during the day after bedtime administration of zopiclone, showed lack of residual effects and no residual impairment of cognitive functions. Zopiclone discontinuation is not accompanied by rebound effect and relevant withdrawal symptoms. Specific "craving effect" studies in alcoholics did not show an abuse potential for zopiclone. Side-effects are represented mainly by bitter taste and dry mouth with a minimal incidence of CNS depressant effects. Studies on the effects of zopiclone on respiratory functions failed to show detrimental effects. Efficacy and safety data on zopiclone suggest that this new drug can represent a useful alternative to existing hypnotics.

Azabicyclo Compounds↗