Search PubMed⌕ Search

Biomedical subjects

F J Marshall

Publications and source records attributed to F J Marshall.

At least 19 recordsLinked to original sources

A clinical rating scale for Batten disease: reliable and relevant for clinical trials.

BACKGROUND: Batten disease (juvenile neuronal ceroid lipofuscinosis [JNCL]) is an autosomal recessive neurodegenerative disorder characterized by blindness, seizures, and relentless decline in cognitive, motor, and behavioral function. Onset is in the early school years, with progression to death typically by late adolescence. Development of a clinical instrument to quantify severity of illness is a prerequisite to eventual assessment of experimental therapeutic interventions. OBJECTIVE: To develop a clinical rating instrument to assess motor, behavioral, and functional capability in JNCL. METHODS: A clinical rating instrument, the Unified Batten Disease Rating Scale (UBDRS), was developed by the authors to assess motor, behavioral, and functional capability in JNCL. Children with verified JNCL were evaluated independently by three neurologists. Intraclass correlation coefficients (ICCs) were used to estimate the interrater reliability for total scores in each domain. Interrater reliability for scale items was assessed with weighted kappa statistics. RESULTS: Thirty-one children with confirmed JNCL (10 boys, 21 girls) were evaluated. The mean age at symptom onset was 6.1 +/- 1.6 years, and the mean duration of illness was 9.0 +/- 4.4 years. The ICCs for the domains were as follows: motor = 0.83, behavioral = 0.68, and functional capability = 0.85. CONCLUSIONS: The Unified Batten Disease Rating Scale (UBDRS) is a reliable instrument that effectively tests for neurologic function in blind and demented patients. In its current form, the UBDRS is useful for monitoring the diverse clinical findings seen in Batten disease.

Adolescent↗

Effects of nonuniform illumination on implosion asymmetry in direct-drive inertial confinement fusion.

Target areal density (rhoR) asymmetries in OMEGA direct-drive spherical implosions are studied. The rms variation / for low-mode-number structure is approximately proportional to the rms variation of on-target laser intensity / with an amplification factor of approximately 1/2(C(r)-1), where C(r) is the capsule convergence ratio. This result has critical implications for future work on the National Ignition Facility as well as OMEGA.

Journal Article↗

Dependence of shell mix on feedthrough in direct drive inertial confinement fusion.

The mixing of cold, high-density shell plasma with the low-density, hot spot plasma by the Rayleigh-Taylor instability in inertial confinement fusion is experimentally shown to correlate with the calculated perturbation feedthrough from the ablation surface to the inner shell surface. A fourfold decrease in the density of shell material in the mix region of direct drive implosions of gas filled spherical plastic shells having predicted convergence ratios approximately 15 was observed when laser imprint levels were reduced and the initial shell was thicker, corresponding to a reduction in the feedthrough rms level by a factor of 6. Shell mix is also shown to limit the spherical compression of the implosion.

Journal Article↗

Shell mix in the compressed core of spherical implosions.

The Rayleigh-Taylor instability in its highly nonlinear, turbulent stage causes atomic-scale mixing of the shell material with the fuel in the compressed core of inertial-confinement fusion targets. The density of shell material mixed into the outer core of direct-drive plastic-shell spherical-target implosions on the 60-beam, OMEGA laser system is estimated to be 3.4(+/-1.2) g/cm(3) from time-resolved x-ray spectroscopy, charged-particle spectroscopy, and core x-ray images. The estimated fuel density, 3.6(+/-1) g/cm(3), accounts for only approximately 50% of the neutron-burn-averaged electron density, n(e)=2.2(+/-0.4)x10(24) cm(-3).

Journal Article↗

Evolution of shell nonuniformities near peak compression of a spherical implosion.

The evolution of shell modulations near peak compression of direct-drive spherical-target implosions has been measured using the 60-beam, 30-kJ UV OMEGA laser system. The spatial size and amplitude of shell-areal-density modulations decrease during the target compression, then increase during its decompression as expected. The shell uniformity at peak compression has been increased by reducing single-beam, laser-drive nonuniformity.

Journal Article↗

Clinical research in neurology. From observation to experimentation.

Clinical research in neurology may be based on observation or intervention. Basic science and observational clinical studies often address questions of cause and pathogenesis, whereas interventional clinical experiments normally are required to establish the safety, tolerability, and efficacy of therapies. This article outlines various study paradigms and discusses the concepts of intervention, randomization, blinding, and control in the context of clinical trial design. Accurate interpretation of trial results is predicated on the care with which experimental therapeutic studies are designed and conducted.

Bias↗

Effect of variable doses of dexamethasone on posttreatment endodontic pain.

One hundred six patients with pretreatment pain presenting for endodontic treatment participated in a controlled double blind study. After root canal therapy, the patients were given an intraoral intramuscular injection of either a saline placebo or various dosages of dexamethasone. Posttreatment pain incidence and severity were evaluated at 4, 8, 24, 48, and 72 h. Injection of the various dosages of dexamethasone, taken as a group, was shown to significantly reduce the severity of pain at 4 and 8 h, and 0.07 to 0.09 mg/kg dosage alone significantly reduced pain at 8 h. Patients who received dexamethasone took significantly fewer posttreatment pain medications than those who received the placebo. Although there was a trend toward a reduction in the incidence of posttreatment pain for patients who received dexamethasone, the difference was not statistically significant.

Analysis of Variance↗

A 24-week study of the microleakage of four retrofilling materials using a fluid filtration method.

The microleakage after retrofillings of amalgam, amalgam with cavity varnish, silver-containing glass ionomer cement, and intermediate restorative material was compared in vitro. Thirty-six extracted human incisors and canines were instrumented, obturated with gutta-percha without sealer, subjected to apicoectomy, and retrofilled with the materials described above. After removal of the gutta-percha filling, the microleakage from both directions (apically and coronally) was measured quantitatively and longitudinally for 24 wk after filling by a fluid filtration technique. All four retrofilling materials revealed some apical and coronal leakage at all time periods. The amalgam group showed statistically significant (p less than 0.001) apical leakage at 1.5 h. The use of cavity varnish significantly reduced the apical leakage of the amalgam group at 1.5 h. The silver-containing glass ionomer cement and intermediate restorative material groups showed significantly (p less than 0.05) less coronal leakage compared with the amalgam group at 1.5 h. Scanning electron microscopy of selected samples showed marginal defects of approximately 5 microns between the root dentin and the retrofilling material.

Cermet Cements↗

The effects of periodontal ligament injection on pulpal and periodontal tissues.

This study was designed to investigate histologically the effects of the periodontal ligament injection on the pulp of teeth with or without subsequent amalgam restorations, and the effects of the injection on the periodontium. Eighty-eight injections were made on 55 teeth in dogs in intervals from 10-min to 30-day prefixation, while 18 teeth were not injected and evaluated as controls. After perfusion fixation, block sections were decalcified, sectioned longitudinally, stained, and evaluated microscopically by three independent examiners. The pulps were graded for degree of inflammation and the periodontal ligaments were examined for signs of tissue disruption. The results of the pulp study were evaluated statistically and showed no apparent effect on the pulp from the injection. Several periodontal ligaments showed evidence of the injection, ranging from tissue disruption shortly postinjection to areas of active external root resorption in 30-day specimens. It was concluded that this technique does not have long-term deleterious effects on the pulp, but can induce localized external root resorption.

Anesthesia, Dental↗

In vitro quantification of the apical sealing ability of retrograde amalgam fillings.

Retrograde amalgam fillings were placed in 12 extracted human canines. The microleakage from the both directions (coronally and apically) was determined using pressurized fluid filtration at 90 min, 6 h, 1 day, 2 days, and 1,2,4, and 8 wk after amalgam filling. Leakage from either direction decreased markedly in the 90-min to 6-h interval after filling. At intervals between 1 day and 8 wk, only small changes in leakage were noted. After any time period, leakage from the coronal direction was greater than leakage from the apical direction. However, this difference was not statistically significant except at 90 min when the coronal leakage was significantly greater. This experimental system was shown to reliably measure microleakage in retrograde amalgam fillings.

Cuspid↗

Second opinions.

Explore the source record for details and available documents.

Animals↗

A comparison of two post systems under applied compressive-shear loads.

This study compared a new parallel-tapering, threaded, split-shank post with a well-accepted parallel serrated post under applied compressive-shear loads. The posts were placed in paired, contralateral human teeth to attempt to minimize variation in the tooth model. Both initial and ultimate failure modes were observed, and the clinical significance reported. The Flexi-post system compared favorably with the Para-Post system under the conditions of this research.

Crowns↗

Permeability of apical barriers.

The purpose of this work was to measure the permeability (hydraulic conductance) of root canal apical barriers in vitro. In 30 extracted teeth, the pulp tissue was removed and the apical opening standardized and enlarged using endodontic files. One-millimeter thick barriers of either autogenous dentin chips, calcium hydroxide powder, or durapatite particles were placed just inside the apical opening. The prepared teeth were mounted in a special chamber, fluid pressure applied, and the resultant flow measured. The permeability of dentin chip barriers in 10 additional teeth with nonstandardized apical openings was measured also. The standardized canals with the autogenous dentin chip barriers had a mean permeability of 0.0010 microliter/s/psi at 20 psi applied pressure. Teeth with calcium hydroxide barriers averaged 0.0012 microliter/s/psi. The durapatite particle barriers were much more permeable and averaged 0.0220 microliter/s/psi. It was concluded that this technique is useful in evaluating the effectiveness of apical barrier materials. For the materials tested, autogenous dentin chips and calcium hydroxide barriers have significantly lower permeability than durapatite barriers (p = 0.05).

Calcium Hydroxide↗

Effects of distance from the pulp and thickness on the hydraulic conductance of human radicular dentin.

The purposes of this study were: (1) to measure the effect of distance from the pulp on the hydraulic conductance of human radicular dentin; (2) to determine the influence of dentin thickness on the rates of fluid flow; and (3) to attempt to correlate dentinal tubule densities and diameters with root dentin hydraulic conductance. Dentin slabs prepared from extracted, unerupted, human third molar teeth were placed in a split-chamber device to permit quantitation of fluid filtration rate (hydraulic conductance). In the SEM portion of the study, dentinal tubule numbers and diameters were recorded. The results indicated that radicular dentin hydraulic conductance decreased with distance from the pulp and with increasing dentin thickness. Tubule density and diameter correlated well with the measured hydraulic conductances. The relatively low hydraulic conductance of outer root dentin makes it a significant barrier to fluid movement across root structure.

Adult↗