Search PubMed⌕ Search

Biomedical subjects

F Avni

Publications and source records attributed to F Avni.

33 records · Page 2Linked to original sources

Twin-twin transfusion syndrome--possible roles for Doppler ultrasound and amniocentesis.

A 29-year-old woman was referred for suspicion of twin-twin transfusion syndrome (TTTS). Several ultrasonographic and neonatal criteria of TTTS were encountered in this twin pregnancy. The peculiar observations in this case were, firstly, the demonstration of superficial anastomosis by Doppler ultrasound and, secondly, that one single therapeutic amniocentesis could have been sufficient to partially correct the progression of the syndrome, as after amniocentesis it was no longer possible to demonstrate the vascular communication. This observation suggests that superficial anastomoses could also have a role in the genesis of TTTS. Their effect could be monitored by Doppler ultrasound and could be more easily corrected by therapeutic amniocentesis.

Adult↗

Experience of a single team of operators in 891 diagnostic funipunctures.

OBJECTIVE: To assess the efficacy and safety of diagnostic funipuncture. METHODS: Between October 1985 and November 1993, fetal circulation was accessed 891 times in 828 pregnancies. The technique was similar to that described in earlier studies. We did not make more than two attempts at the procedure in any session. Each procedure was recorded prospectively in a computerized data base. Data included information about indications, laboratory indices, gestational age, number of successful and failed punctures, duration of fetal bradycardia, duration of bleeding, ultrasonographic findings, follow-up of pregnancies, and perinatal outcome. RESULTS: The most frequent indication was rapid karyotyping (48.9%), followed by risk of congenital infection (38.6%). The success rate of the method was high (98.6%). Most samples (97%) were pure fetal blood, undiluted by amniotic fluid. Transient bleeding was observed from the cord puncture site in 9.8% of the procedures. Sixty-three percent of prolonged bradycardia occurred in growth-retarded or congenitally malformed fetuses. Seven fetal and neonatal deaths (five pregnancies) occurred within 1 week after the funipuncture; the funipuncture indication was rapid karyotyping in four of these cases. CONCLUSION: Funipuncture performed by operators trained in ultrasonic needle guidance is a safe and reliable procedure.

Blood Specimen Collection↗

[Collection of fetal cord blood for karyotyping].

Cordocentesis was performed in 234 pregnancies (241 fetuses) for rapid karyotyping. The indication was in 86% of cases: abnormal ultrasound. The abnormality encountered were IUGR (85 fetuses) or morphologic abnormality of the pregnancy (130 fetuses). The other indications were maternal mosaicism, mosaicism in cultured amniotic cells, maternal age (late booking), fragile X syndrome, confirmation of abnormal karyotype obtained by amniocentesis. The fetal karyotype was established in 97.5% (6 failures), 18 karyotypes were abnormal in the group "abnormal ultrasound" (208 pregnancies, 8.6%; 215 fetuses, 8.3%). No maternal complication were observed, there were 6 fetal losses (2.5%).

Blood Specimen Collection↗

[Cordocentesis: experience in 391 initial samples].

The first diagnostic cordocentesis was performed in our unit in october 1985. Our 4-year experience is reported: 391 cordocentesis were performed in 360 patients during gestational weeks 14 to 42. The first attempt was successful in 90% of the procedures, 4 samplings failed, there were 4 fetal deaths within one week after diagnostic cordocentesis, one of them appears to be directly linked to the punction. A transient fetal bradycardia was observed in 9.9% of the cases, bleeding occurred in 19% of the cases. The indications for cordocentesis were: risk of fetal infection, karyotyping, hemopathy, search for paternity, assessment of fetal acid-base status, biochemical dosage. Our data confirm that cordocentesis is a safe and reliable diagnostic procedure providing guidelines for management of the pregnancy.

Chromosome Aberrations↗

[The value of prenatal chromosomal diagnosis in cases of fetal abnormalities: results obtained in 468 pathological pregnancies].

The authors report the results of 468 foetal karyotypes performed on amniotic fluid or foetal blood samples after ultrasound discovery of foetal anomalies. A total of 46 chromosomal aberrations (10%) were detected. The rates of anomalies vary considerably according to the alarm sign; very high (greater than 30%) in cases of multiple malformations, foetal hydrops or foetal death, low (less than or equal to 2%) in cases of poly- or oligohydramnios and foetal growth retardation without detectable malformation. In addition to these chromosomal diagnoses, further investigations enabled in 9 cases the diagnosis of genetic autosomal recessive disorders. Our results which are comparable with those reported in the literature, demonstrate the importance of prenatal diagnosis in cases of pathological pregnancies, with regard to obstetrical and perinatal management as well as to genetic counseling.

Chromosome Aberrations↗

Diagnostic cordocentesis: two years of experience.

The first diagnostic cordocentesis was performed in our unit in October 1985, our 2-year experience is reported. 144 samplings were performed in 137 patients (139 fetuses - 2 patients had twin pregnancies) during gestational weeks 14 to 42. The first attempt was successful in 80% of the procedures, 4 samplings failed. There were no fetal deaths within 3 days after diagnostic cordocentesis, a transient fetal bradycardia was observed in 12.2% of the cases, bleeding occurred in 13.6% of the cases. The indications for cordocentesis were: risk of fetal infection, karyotyping, hemophilia A, alloimmunisation, search for paternity, assessment of fetal acid-base status. Our data confirm that cordocentesis is a safe and reliable diagnostic procedure providing guidelines for management of the pregnancy.

Blood Specimen Collection↗

[Cervical ectopic thymus].

Two cases of cervical aberrant thymus in infants are reported; it's important to identify such ectopia because thymic tissue involutes spontaneously later on; neither surgery nor other treatment is needed. Ultrasonography is a method of choice for tissue characterization of ectopic thymus and differential diagnosis with other cervical masses.

Diagnosis, Differential↗

The sonographic evaluation of normal thymus in infants and children.

Sonography has been used to evaluate 50 "asymptomatic" infants (aged from birth up to two years) with typical appearing thymus on chest X-ray. The ultrasonic features of the normal gland are described. Moreover, the contribution of ultrasound is illustrated by five cases of partially ectopic thymus and by one case of prominent gland in a teenager. Ultrasound may help in differentiating normal gland from mediastinal masses by defining echogenicity, location and extension.

Choristoma↗

Pathological pregnancies. Results of amniotic fluid studies and fetal outcome.

Late amniocenteses (greater than 20 weeks' gestation) were performed in 114 pregnancies with no a priori genetic risk, but referred because of abnormal clinical and/or ultrasound findings suggesting fetal malformations. Reasons for referral included polyhydramnios (51 cases), oligohydramnios (15 cases), fetal growth retardation (FGR) (16 cases) and abnormal fetal ultrasound findings excluding anencephaly (32 cases). In 42 of these cases, referral was motivated by a combination of the above abnormal findings. When polyhydramnios was the sole anomaly (25 cases), 5 fetuses were malformed (20%), abnormal fetal karyotype and/or elevated amniotic fluid alphafetoprotein (AFP) were demonstrated in 2 cases. Oligohydramnios was the sole anomaly in one case; the infant died of prematurity. Fetal growth retardation was the sole anomaly in 14 cases, 11 otherwise normal newborns were small for date, 2 died at birth and 1 was malformed (1/14, 7%). In this group all fetal karyotypes were normal and in 2 cases amniotic fluid AFP were increased. In the 32 pregnancies without abnormal amniotic fluid volume and/or FGR and with fetal malformation(s) suggested by ultrasound, all malformations except one (ovarian cyst possibly ruptured during birth) were confirmed at birth, amniotic fluid AFP was elevated, and/or karyotype was abnormal in 6 cases. In 42 pregnancies where more than one alarm sign was present, abnormal karyotype and/or elevated amniotic fluid AFP level were recorded in 21 of the 39 cases where amniocentesis was performed, 33 fetuses were malformed (79%) and 13 died in the perinatal period (31%). The high incidence of abnormal results of amniocentesis found in this survey of pathological pregnancies, particularly in those with multiple alarm signs, emphasizes the need for amniocentesis in these situations.

Congenital Abnormalities↗

Cordocentesis for rapid karyotype: 421 consecutive cases.

Between October 1985 and December 1993, 421 patients underwent fetal blood sampling for rapid karyotyping (426 samplings, 5 twin pregnancies). The aim of the study was to evaluate cordocentesis in terms of results, complications and additional information in this specific indication especially in case of abnormal pregnancy sonogram. The fetal loss rate possibly related to fetal blood sampling was 1.9%. Abnormal sonograms represented 91% of rapid karyotype indications. Chromosomal abnormalities were found in 9.5% of abnormal sonograms and in 16.9% of fetal structural anomalies (37 cases). The commonest chromosomal abnormality was trisomy 21 (11 cases). In conclusion, cordocentesis is a safe and reliable method for rapid karyotyping although it is associated with more risks than in other indications (congenital infections). The high rate of chromosomal abnormalities pleaded for ultrasonographic screening in a population usually not investigated by cytogenetic studies.

Adolescent↗