Deep UV laser-induced fluorescence detection of unlabeled drugs and proteins in microchip electrophoresis.

Deep UV fluorescence detection at 266-nm excitation wavelength has been realized for sensitive detection in microchip electrophoresis. For this purpose, an epifluorescence setup was developed enabling the coupling of a deep UV laser into a commercial fluorescence microscope. Deep UV laser excitation utilizing a frequency quadrupled pulsed laser operating at 266 nm shows an impressive performance for native fluorescence detection of various compounds in fused-silica microfluidic devices. Aromatic low molecular weight compounds such as serotonin, propranolol, a diol, and tryptophan could be detected at low-micromolar concentrations. Deep UV fluorescence detection was also successfully employed for the detection of unlabeled basic proteins. For this purpose, fused-silica chips dynamically coated with hydroxypropylmethyl cellulose were employed to suppress analyte adsorption. Utilizing fused-silica chips permanently coated with poly(vinyl alcohol), it was also possible to separate and detect egg white chicken proteins. These data show that deep UV fluorescence detection significantly widens the application range of fluorescence detection in chip-based analysis techniques.

Chymotrypsinogen↗

Separation of fluorescein isothiocyanate-labeled amines by microchip electrophoresis in uncoated and polyvinyl alcohol-coated glass chips using water and dimethyl sulfoxide as solvents of background electrolyte.

On-chip capillary electrophoresis with uncoated and polyvinyl alcohol-coated glass channels in aqueous and nonaqueous dimethyl sulfoxide (DMSO) background electrolyte (BGE) solutions was applied in the separation of five amines derivatized with fluorescein-5-isothiocyanate. In aqueous BGE at pH 9.2, baseline separation of the analytes was not achieved on uncoated glass chips, but the separation was clearly improved when the chip channels were coated with polyvinyl alcohol (PVA). Separation was successful in nonaqueous DMSO electrolyte solution containing ammonium acetate and sodium methoxide, on both uncoated and PVA-coated glass microchips. The differences in the pK(a) values of analytes were probably amplified in DMSO, and all five analytes were at least partly dissociated and were separated. Because the viscosity of DMSO is higher than that of water, the migration times were longer in DMSO.

Amines↗

Subsecond chiral separations on a microchip.

Fast chiral separation of DNS-amino acids could be realized using microchip electrophoresis with fluorescence detection. For this purpose, highly sulfated cyclodextrins (HS-gamma-CD) were used as chiral selectors enabling high selectivity. Even subsecond separation of DNS-tryptophan, DNS-norleucine, DNS-phenylalanine, DNS-methionine, and DNS-aspartic acid could be achieved. Baseline separation could be accomplished within 720 ms, which is the fastest separation of enantiomers reported to date. A more complex mixture consisting of three chiral DNS-amino acids could be separated within 3.3 s utilizing a separation length of only 7 mm and an electrical field strength of 2012 V/cm.

Amino Acids↗

High-speed chiral separations on a microchip with UV detection.

Fast chiral separations of a variety of basic and acidic compounds could be realized on microfluidic quartz chips. A microchip electrophoresis instrument equipped with a linear imaging UV-detector was used. The usually applied but troublesome fluorescence tagging in order to enable fluorescence detection could be omitted. Using sulfated cyclodextrins as chiral selectors baseline separation of 19 compounds could be achieved in less than 1 min with high reproducibility. The relative standard deviation of migration time was below 7%. The fastest separation could be performed in 2.5 s which is to date the fastest separation of enantiomers reported. It was possible to apply microchip electrophoresis (MCE) for the determination of high enantiomeric excess (ee) values, as exemplarily shown for pseudoephedrin where 2% of the minor enantiomer could reliably be determined beside high amount of the other isomer. Successful separation of a mixture of 3 chiral drugs could be performed in a single run in less than 11 s utilizing a separation length of only 12 mm. These results show that MCE has great potential for fast chiral analysis and high-throughput screening.

Buffers↗

Microchip electrophoresis for chiral separations.

Microchip electrophoresis (MCE) is a promising new technique for the separation of enantiomers. This recently introduced technique enables chiral separations to be performed in seconds on tiny micromachined devices. This review is intended to give a brief introduction into the principles of chiral separations with MCE with regard to methodology and instrumentation. Different approaches to realize chiral separations in microfluidic devices are described and discussed. This review gives an overview of original work done in this field with emphasis on approaches to improve detection and resolution in chiral MCE.

Electrophoresis, Capillary↗

Coated microfluidic devices for improved chiral separations in microchip electrophoresis.

Chiral separations of fluorescein isothiocyanate-labeled amines have been performed in poly(vinyl alcohol) (PVA)-coated microfluidic glass chips. Baseline separation of enantiomers could be realized in coated devices while they could not be resolved in uncoated chips. The electroosmotic flow (EOF) in PVA-coated channels is suppressed over a wide pH range which leads to a considerable improved reproducibility of migration times in repetitive analysis. Due to the high resolution obtained in such devices, it was possible to reliable determine the enantiomeric purity with high accuracy. One percent of the minor enantiomer could be determined in the presence of large excess of the other enantiomer. As the EOF was suppressed, the anionic compounds were detected at the anode whereas the dominant EOF in uncoated devices resulted in an effective mobility to the cathode. Applying PVA-coated channels considerable improved precision of migration times was found. The relative standard deviation of migration times was below 1% in PVA-coated devices. Accordingly, excessive rinsing or etching steps in order to stabilize the EOF could be omitted while this was necessary for a reliable operation of uncoated devices.

Electrophoresis, Capillary↗

Surface modification in microchip electrophoresis.

Different approaches and techniques for surface modification of microfluidic devices applied for microchip electrophoresis are reviewed. The main focus is on the improved electrophoretic separation by reducing analyte-wall interactions and manipulation of electroosmosis. Approaches and methods for permanent and dynamic surface modification of microfluidic devices, manufactured from glass, quartz and also different polymeric substrates, are described.

Acrylic Resins↗

Design and performance of a microchip electrophoresis instrument with sensitive variable-wavelength fluorescence detection.

A modular instrument for high-speed microchip electrophoresis (MCE) equipped with a sensitive variable-wavelength fluorescence detection system was developed and evaluated. The experimental setup consists mainly of a lamp-based epifluorescence microscope for variable-wavelength fluorescence detection and imaging and a programmable four-channel bipolar high-voltage source capable of delivering up to +/- 10 kV per channel. The optical unit was equipped with a high-sensitivity photomultiplier tube and an adjustable aperture. The system was applied to MCE separations of flurescein isothiocyanate (FITC)-labelled amines utilizing blue light (450-480 nm) for excitation as well as for the separation of rhodamines utilizing excitation light in the green spectral region (531-560 nm). At optimized conditions baseline separation of four FITC-labelled amines could be obtained in less than 50 s at a detection limit of 460 ppt (1 nM) with a signal-to-noise ratio of 3:1. Three rhodamines could be baseline-separated in less than 6 s at a detection limit of 240 ppt (500 pM). The relative standard deviations of absolute migration times determined in repetitive MCE separations of FITC-labelled amines were below 2.5% (n= 25). By the application of cyclodextrin-modified electrolytes, chiral separation of FITC-labelled amines could be performed in seconds demonstrating the potential of microchip electrophoresis for chiral high-throughput screening.

Cyclodextrins↗

Poly(vinyl alcohol)-coated microfluidic devices for high-performance microchip electrophoresis.

The channels of microfluidic glass chips have been coated with poly(vinyl alcohol) (PVA). Applied for microchip electrophoresis, the coated devices exhibited a suppressed electroosmotic flow and improved separation performance. The superior performance of PVA-coated channels could be demonstrated by electrophoretic separations of labeled amines and by video microscopy. While a distorted sample zone is injected using uncoated channels the application of PVA-coated channels results in an improved shape of the sample zone with less band broadening. Applying PVA-coated microchips for the separation of amines labeled with Alexa Fluor 350 even sub-second separations, utilizing a separation length of only 650 microm, could be obtained, while this was not possible using uncoated devices. By using PVA-coated devices rather than an uncoated chip a threefold increase in separation efficiencies could be observed. As the electroosmotic flow (EOF) was suppressed, the anionic compounds were detected at the anode whereas the dominant EOF in uncoated devices resulted in an effective mobility to the cathode. Besides improved separation performance another important feature of the PVA-coated channels was the suppressed adsorption of fluorescent compounds in repetitive runs which results in an improved robustness and detection sensitivity. Applying PVA-coated channels, rinsing or etching steps could be omitted while this was necessary for a reliable operation of uncoated devices.

Amines↗