Search PubMed⌕ Search

Biomedical subjects

David J Beebe

Publications and source records attributed to David J Beebe.

At least 19 recordsLinked to original sources

Application of sexed semen technology to in vitro embryo production in cattle.

Use of sexed semen in conjunction with in vitro embryo production is a potentially efficient means of obtaining offspring of predetermined sex. For thousands of years, livestock owners have desired a methodology to predetermine the sex of offspring for their herds. The ability to sort individual sperm cells into viable X- and Y-chromosome-bearing fractions made producers' sex selection dreams reality in the 1990s and now semen can be sexed with greater than 90% accuracy with use of a flow cytometric cell sorter. Several concerns regarding the implementation of sexed semen technology include the apparent lower fertility of sorted sperm, the lower survival of sorted sperm after cryopreservation and the reduced number of sperm that could be separated in a specified time period. These issues are discussed in this review. There are also a number of issues that appear to influence the success rates of using sexed semen to produce bovine embryos in vitro. These issues include reductions in fertilization rates, lower cleavage rates, blastocyst rates and pregnancy rates, partial capacitation of the sperm, dilute sperm samples and sire variation. These subjects are also addressed in this paper. Finally, we will describe a recent field trial in which female Holstein embryos produced using the combined technologies of sex-selected semen and microfluidics were transferred either as single or bilateral twin embryos into beef cattle recipients, demonstrating these technologies' contributions to viable embryo production. The results indicate that large-scale transfer of in vitro produced, Holstein heifer embryos to beef recipients is a feasible production scheme.

Animals↗

Controlled microfluidic interfaces.

The microfabrication technologies of the semiconductor industry have made it possible to integrate increasingly complex electronic and mechanical functions, providing us with ever smaller, cheaper and smarter sensors and devices. These technologies have also spawned microfluidics systems for containing and controlling fluid at the micrometre scale, where the increasing importance of viscosity and surface tension profoundly affects fluid behaviour. It is this confluence of available microscale engineering and scale-dependence of fluid behaviour that has revolutionized our ability to precisely control fluid/fluid interfaces for use in fields ranging from materials processing and analytical chemistry to biology and medicine.

Diffusion↗

Reduction of polyspermic penetration using biomimetic microfluidic technology during in vitro fertilization.

Efforts to improve the in vitro embryo production process in pigs have included modifying culture medium and number of spermatozoa inseminated in order to reduce the incidence of polyspermy. Polyspermy is a pathological condition which results in aberrant embryonic development. The microchannels are designed to more closely mimic the function of the oviduct and create a flow pattern of spermatozoa past the oocytes similar to the pattern in the oviduct. In vitro fertilization of porcine oocytes in the microchannels has produced a higher incidence of monospermic penetration (p<0.05) as compared to the oocytes fertilized in the traditional microdrop system with comparable penetration and male pronucleus formation rates. Additionally, cleavage rates of the embryos as well as development to the blastocyst stage are similar. Here we demonstrate that the biomimetic microchannel in vitro fertilization system can reduce polyspermy and, therefore, increase the number of potentially viable embryos without reducing the overall in vitro production efficiency.

Animals↗

Diffusion dependent cell behavior in microenvironments.

Understanding the interaction between soluble factors and cells in the cellular microenvironment is critical to understanding a wide range of diseases. Microchannel culture systems provide a tool for separating diffusion and convection based transport making possible controlled studies of the effects of soluble factors in the cellular microenvironment. In this paper we compare the proliferation kinetics of cells in traditional culture flasks to those in microfluidic channels, and explore the relationship between microchannel geometry and cell proliferation. PDMS (polydimethylsiloxane) microfluidic channels were fabricated using micromolding methods. Fall armyworm ovarian cells (Sf9) were homogeneously seeded in a series of different sized microchannels and cultured under a no flow condition. The proliferation rates of Sf9 cells in all of the microchannels were slower than in the flask culture over the first 24 h of culture. The proliferation rates in the microchannels then continuously decreased reaching 5% of that in the flasks over the next 48 h and maintained this level for 5 days. This growth inhibition was reversible and influenced only by the cell seeding density and the channel height but not the channel length or width. One possible explanation for the observed dimension-dependent cell proliferation is the accumulation of different functional molecules in the diffusion dominant microchannel environment. This study provides insights into the potential effects of the diffusion of soluble factors and related effects on cell behavior in microenvironments relevant to the emerging use of microchannel culture systems.

Animals↗

Continuous fabrication of biocatalyst immobilized microparticles using photopolymerization and immiscible liquids in microfluidic systems.

We report a novel technique for manufacturing polymeric microparticles containing biocatalysts by the behavior of immiscible liquids in microfluidic systems and in situ photopolymerization. The approach utilizes a UV-polymerizable hydrogel/enzyme solution and an immiscible oil solution. The oil and hydrogel solutions form emulsions in pressure-driven flow in microchannels at high values of the dimensionless capillary number (Ca). The resultant hydrogel droplets are then polymerized in situ via exposure to 365 nm UV light. This technique allows for the generation of monodisperse particles whose size can be controlled by the regulation of flow rates. In addition, both manufacturing microparticles and immobilizing biocatalysts can be performed simultaneously and continuously.

Biosensing Techniques↗

Development of a disposable infusion system for the delivery of protein therapeutics.

This paper describes the development and optimization of a low flow open-loop infusion device for continuous delivery of protein therapeutics. Specifically, a non-electronic polymer device is actuated with responsive hydrogels to infuse at 2 microL/hr for 12 hours. Hydrogel actuators transduce a chemical signal (change in pH of the local environment) into a mechanical response (swelling) generating the pressure to drive the infusion. The hydrogel actuators are separated from the drug reservoir by an elastomeric impermeable membrane. As the hydrogel actuators expand, the expansion deflects the flexible membrane down and reduces the volume of the drug reservoir causing the infusion of drug through the needle that is the only outlet for the reservoir.

Diffusion↗

Magnetically-driven biomimetic micro pumping using vortices.

Planar micropumps utilizing vortices shed by an oscillating ferromagnetic bar are presented. The movement of the bar is induced by magnetic coupling with an external spinning magnet. Thus, energy transfer is achieved without physical contact or need of any on-chip power source. To create vortices inside the chip, the Reynolds number is locally increased with the oscillation of the bar. The utilization of the vortices as a tool for efficient transfer of energy is inspired by the behaviour of swimming animals and flying insects in nature. The pumps operate in two different scales (milli-scale and micro-scale) in order to take advantage of both. Experiments are presented characterizing the pumps and their flow patterns. The range of operation of the pumps is from 3 microl min(-1) to 600 microl min(-1), though smaller flow rates are also possible.

Biomimetics↗

Hydrodynamic microfabrication via"on the fly" photopolymerization of microscale fibers and tubes.

A microfluidic apparatus capable of creating continuous microscale cylindrical polymeric structures has been developed. This system is able to produce microstructures (e.g. fibers, tubes) by employing 3D multiple stream laminar flow and "on the fly"in-situ photopolymerization. The details of the fabrication process and the characterization of the produced microfibers are described. The apparatus is constructed by merging pulled glass pipettes with PDMS molding technology and used to manufacture the fibers and tubes. By controlling the sample and sheath volume flow rates, the dimensions of the microstructures produced can be altered without re-tooling. The fiber properties including elasticity, stimuli responsiveness, and biosensing are characterized. Responsive woven fabric and biosensing fibers are demonstrated. The fabrication process is simple, cost effective and flexible in materials, geometries, and scales.

Acrylates↗

An externally driven magnetic microstirrer.

In this paper, an inexpensive, easy-to-fabricate active magnetic mixer is presented. This mixer functions on top of a common magnetic stir plate and is capable of mixing two streams, each at flow rates up to 5 ml min(-1). A liquid-phase photopolymerization technique is used to fabricate the device. An analysis of mixing efficiency is based on greyscale intensity measurements of two coloured streams passing through the mixer. A brief hypothesis of the mechanism of mixing is also presented.

Complex Mixtures↗

Embryonic development in the mouse is enhanced via microchannel culture.

Microfluidic devices (microchannels) have been fabricated and tested for embryo culture. Three different microfabrication materials (silicon, polydimethylsiloxane (PDMS), and borosilicate) were used to fabricate the microchannels. The objective of this study was to determine if static microchannels permitted culture of mouse embryos to the blastocyst stage. Groups of 10 two-cell ICR x B6SJL/F1 mouse embryos were cultured for 96 hours in 4 different physical culture systems: 1) silicon/borosilicate microchannels, 2) PDMS/borosilicate microchannels, and 3) standard microdrops. Embryos cultured in the silicon/borosilicate and PDMS/borosilicate microchannels exhibited a faster rate of cleavage (P < 0.05), and produced more blastocysts (P < 0.01) than control microdrops. Furthermore, microchannels had a lower percentage of degenerated embryos than control embryos (P < 0.01). The results suggest that the microchannel culture systems may provide a culture environment that more closely mimics the in vivo environment.

Animals↗

Flow control with hydrogels.

With the advent of the genomic revolution and the sequencing of the human genome complete, the majority of pharmaceuticals under development are proteins. Consequently, new techniques to more effectively administer these new protein therapeutics need to be developed. One method that is gaining popularity in the research community involves the use of responsive hydrogel actuators for flow control in drug delivery devices. Responsive hydrogels are materials able to undergo a volume change in response to a stimulus from their local environment. The following paper overviews recent advances made using hydrogel actuators for flow control such as resistance based valves, hydrogel jacket valves, hybrid hydrogel membrane valve, electrically triggered valves, and biomimetic valves. Also reviewed are several hydrogel flow control systems such as a flow sorter and pH-regulation system. The chemistry of the hydrogel actuators can be tweaked to allow physiological variables to trigger the volume expansion of the hydrogel actuators as demonstrated by several glucose sensitive hydrogel valves reviewed below. Therefore, the door to physiological feedback controlling the infusion rate in a drug delivery device is opened and has the potential to revolutionize protein pharmaceutical drug delivery.

Drug Delivery Systems↗

Microenvironment design considerations for cellular scale studies.

In vivo cellular microenvironments are not well-mimicked in present in vitro cell culture systems. Microtechnology, and microfluidics in particular, provides the tools to create in vivo-like cellular microenvironments in vitro. Features of in vitro cellular microenvironments are discussed and compared to macroscale cell culture environments; the concept of an effective culture volume (ECV) is introduced to facilitate the comparison. Current research using microtechnology to investigate in vitro cellular microenvironments is presented and areas where more research is needed in characterizing the in vitro microenvironment are outlined.

Adsorption↗

Microfluidic tectonics platform: A colorimetric, disposable botulinum toxin enzyme-linked immunosorbent assay system.

A fabrication platform for realizing integrated microfluidic devices is discussed. The platform allows for creating specific microsystems for multistep assays in an ad hoc manner as the components that perform the assay steps can be created at any location inside the device via in situ fabrication. The platform was utilized to create a prototype microsystem for detecting botulinum neurotoxin directly from whole blood. Process steps such as sample preparation by filtration, mixing and incubation with reagents was carried out on the device. Various microfluidic components such as channel network, valves and porous filter were fabricated from prepolymer mixture consisting of monomer, cross-linker and a photoinitiator. For detection of the toxoid, biotinylated antibodies were immobilized on streptavidin-functionalized agarose gel beads. The gel beads were introduced into the device and were used as readouts. Enzymatic reaction between alkaline phosphatase (on secondary antibody) and substrate produced an insoluble, colored precipitate that coated the beads thus making the readout visible to the naked eye. Clinically relevant amounts of the toxin can be detected from whole blood using the portable enzyme-linked immunosorbent assay (ELISA) system. Multiple layers can be realized for effective space utilization and creating a three-dimensional (3-D) chaotic mixer. In addition, external materials such as membranes can be incorporated into the device as components. Individual components that were necessary to perform these steps were characterized, and their mutual compatibility is also discussed.

Antibodies↗

Developments in in vitro technologies for swine embryo production.

Several modifications have been made to in vitro production (IVP) systems to allow more efficient production of viable porcine embryos. Although in vitro production of pig embryos has been studied for over 30 years, the overall blastocyst production rate remains low. The low blastocyst rate is due to several factors, including polyspermic oocyte penetration, low rate of male pronucleus formation and less than optimal in vitro culture systems. These conditions are all inherent problems in porcine IVP and many of the mechanisms involved remain unknown. Considerable research has examined culture medium and the techniques used during the various stages of in vitro production. However, changes to the physical culture system used during IVF have remained unchanged until recently. The present paper will summarise selected developments in fertilisation and embryo culture media composition and focus on the development of modified equipment to improve the conditions used during the IVP of porcine oocytes and embryos.

Animals↗

Microfluidic valve with cored glass microneedle for microinjection.

In this paper, a new microinjection device was constructed by fusing a glass microneedle and a PDMS-based microvalve. The microneedle was fabricated via traditional micropipette pulling. The PDMS-based microvalve regulates the fluid flow in the microchannel and microneedle. The 'ON/OFF' operation of the valve was controlled by manually supplied pneumatic pressure. The valve membrane utilized a two level geometry to improve control at low flow rates. The relation between pressure and flow was measured and the results showed that very small volumes of fluid (>1 nl) could be controlled. The valve operation was investigated by monitoring the tip of the needle and pneumatic pressure simultaneously and it demonstrated very stable 'ON/OFF' operation to the pressure change.

Dimethylpolysiloxanes↗